Comparison of Radiation Doses between 64-slice Single Source and 128-slice Dual Source CT Coronary Angiography in patient (64-slice single source CT와 128-slice dual source CT를 이용한 관상동맥 조영 검사 시 환자선량 비교)

  • Kang, Yeong-Han
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.2
    • /
    • pp.129-136
    • /
    • 2012
  • The purpose of this study was to estimate radiation doses from 64-slice single source Computed Tomography(SSCT) coronary angiography(CA) and 128-slice dual source Computed Tomography(DSCT). With SSCT CA, the effective dose averaged approximately 13.86 mSv when two dose modulation was not. The mean effective dose for DSCT CA with retrospectively gated helical(RGH) technique was 11.87 mSv, when prospective ECG gating transverse(PGT) without dose modulation technique was 5.61 mSv. The one with dose modulation in PGT technique and flash mode were 3.04 mSv and flash mode was 0.98 mSv respectively. The lifetime attributable risk(LAR) of cancer incidence from SSCT RGH mode averaged approximately 1 for 1,176, and DSCT averaged 1 for 1,960(RGH mode), 1 for 3,030(PGT without modulation), 1 for 5,882(PGT with modulation). Because of CTCA is associated with non-negligible risk of cancer. Doses can be reduced by application PGT, FLASH than RGH using DSCT.

Investigation of organ dose difference of age phantoms for medical X-ray examinations (X선 촬영 시 연령별 장기선량 차이 연구)

  • Park, Sang-Hyun;Lee, Choon-Sik;Kim, Woo-Ran;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2003
  • Methodology for calculating the organ equivalent doses and the effective doses of pediatric and adult patients undergoing medical X-ray examinations were established. The MIRD-type mathematical phantoms of 4 age groups were constructed with addition of the esophagus to the same phantoms. Two typical examination procedures, chest PA and abdomen AP, were simulated for the pediatric patients as well as the adult as illustrative examples. The results confirmed that patients pick up approximate 0.03 mSv of effective dose from a single chest PA examination, and 0.4 to 1.7 mSv from an abdomen AP examination depending on the ages. For dose calculations where irradiation is made with a limited field, the details of the position, size and shape of the organs and the organ depth from the entrance surface considerably affect the resulting doses. Therefore, it is important to optimize radiation protection by control of X-ray properties and beam examination field. The calculation result, provided in this study, can be used to implement optimization for medical radiation protection.

Characterization of Radiation Field in the Steam Generator Water Chambers and Effective Doses to the Workers (증기발생기 수실의 방사선장 특성 및 작업자 유효선량의 평가)

  • Lee, Choon-Sik;Lee, Jai-Ki
    • Journal of Radiation Protection and Research
    • /
    • v.24 no.4
    • /
    • pp.215-223
    • /
    • 1999
  • Characteristics of radiation field in the steam generator(S/G) water chamber of a PWR were investigated and the anticipated effective dose rates to the worker in the S/G chamber were evaluated by Monte Carlo simulation. The results of crud analysis in the S/G of the Kori nuclear power plant unit 1 were adopted for the source term. The MCNP4A code was used with the MIRD type anthropomorphic sex-specific mathematical phantoms for the calculation of effective doses. The radiation field intensity is dominated by downward rays, from the U-tube region, having approximate cosine distribution with respect to the polar angle. The effective dose rates to adults of nominal body size and of small body size(The phantom for a 15 year-old person was applied for this purpose) appeared to be 36.22 and 37.06 $mSvh^{-1}$) respectively, which implies that the body size effect is negligible. Meanwhile, the equivalent dose rates at three representative positions corresponding to head, chest and lower abdomen of the phantom, calculated using the estimated exposure rates, the energy spectrum and the conversion coefficients given in ICRU47, were 118, 71 and 57 $mSvh^{-1}$, respectively. This implies that the deep dose equivalent or the effective dose obtained from the personal dosimeter reading would be the over-estimate the effective dose by about two times. This justifies, with possible under- or over- response of the dosimeters to radiation of slant incidence, necessity of very careful planning and interpretation for the dosimetry of workers exposed to a non-regular radiation field of high intensity.

  • PDF

Study of Absorbed Dose and Effective Dose for Prostate Cancer Image Guided Radiation Therapy using kV Cone Beam Computed Tomography (kV Cone Beam Computed Tomography (CBCT)를 이용한 전립선암 영상유도방사선치료 시 흡수선량 및 유효선량에 관한 고찰)

  • Na, Jong-Eok;Lee, Do-Geun;Kim, Jin-Soo;Baek, Geum-Mun;Kwon, Kyung-Tae
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.21 no.2
    • /
    • pp.67-74
    • /
    • 2009
  • Purpose: To evaluate the results of absorbed and effective doses using two different modes, standard mode (A-mode) and low-dose mode (B-mode) settings for prostate cancer IGRT from CBCT. Materials and Methods: This experimental study was obtained using Clinac iX integrated with On Board Imager (OBI) System and CBCT. CT images were obtained using a GE Light Speed scanner. Absorbed dose to organs from ICRP recommendations and effective doses to body was performed using A-mode and B-mode CBCT. Measurements were performed using a Anderson rando phantom with TLD-100 (Thermoluminescent dosimeters). TLD-100 were widely used to estimate absorbed dose and effective dose from CBCT with TLD System 4000 HAWSHAW. TLD-100 were calibrated to know sensitivity values using photon beam. The measurements were repeated three times for prostate center. Then, Evaluations of effective dose and absorbed dose were performed among the A-mode and B-mode CBCT. Results: The prostate absorbed dose from A-mode and B mode CBCT were 5.5 cGy 1.1 cGy per scan. Respectively Effective doses to body from A mode and B-mode CBCT were 19.1 mSv, 4.4 mSv per scan. Effective dose from A-mode CBCT were approximately 4 times lower than B-mode CBCT. Conclusion: We have shown that it is possible to reduce the effective dose considerably by low dose mode(B-mode) or lower mAs CBCT settings for prostate cancer IGRT. Therefore, we should try to select B-mode or low condition setting to decrease extra patient dose during the IGRT for prostate cancer as possible.

  • PDF

Risperidone as a Janus in Mood Disorder (기분장애에서 risperidone의 양면성)

  • Yoon, Doh Joon
    • Korean Journal of Biological Psychiatry
    • /
    • v.4 no.2
    • /
    • pp.198-210
    • /
    • 1997
  • To examine the double-faced thymoleptic(antidepressant and antimanic) effects of risperidone in mood disorders, this article reviews the psychotropic-induced mania, thymoleptic effects of antipsychotics, therapeutic effects of risperidone and risperidone(RIS)-induced mania(RIM) in mood disorders, risk factors of RIM, possible neurochemical mechanism of these thymoleptic effects, pathophysiological and clinical significance of thymoleptic effects, and suggestive clinical guideline of RIS in mood disorders. RIS appeared effective for bipolar disorder at a lower dose than that recommended for schizophrenia, especially in the cases of maintenance of mood stabilizers, and gradual titration from low doses. Manic induction/exacerbation can occur by chance during RIS treatment in mood disorders, schizoaffective disorders, and schizophrenias. The possible risk factors for RIM are refractory mood disorder, especially in bipolar I disorder with poor initial response ; refractory schizoaffective disorders, especially in bipolar type with poor initial response ; refractory chronic schizophrenias, especially with initial responses ; psychotic features ; higher initial doses ; rapid titration ; combined therapy with antidepressants in refractory depression ; and RIS monotherapy in mania/hypomania. RIS is a drug that preferentially block 5-HT2 receptors. The effects of low dose are due mainly to the blockade of 5-HT2 receptors. There are more gradual increase in D2 blockade with increasing dose and this D2 blocking properties become apparent at higher doses. This may be related to a modulation of dopaminergic transmission by 5-HT2 antagonism at lower doses with the direct action of RIS on DA receptors coming into play at higher dose. The serotonergic antagonistic effect may be important for its effects on depressive symptoms. This, together with adequate blo-ckade of D2 receptors, may not necessarily lead to destabilization of mood disorder, but rather to more therapeutic effects. Therefore, this dose-receptor affinity relationship with both antidepressant and antimanic effects according to treatment duration can explain a continuum of antidepressant effect, antimanic effect, behavioral stimulation, and manic/hypomanic induction/exacerbation. It was the recognition of a useful psychiatric side effects by a thoughtful observer with fertile minds that led to their ultimate utilization as psychotropic drugs, i.e., phenothiazine, MAOI, TCA, and lithium. And, in vivo pharmacological challenge by novel psychotropics, as a neurochemical probe, with more specific actions is a useful tool to select pharmacologically homogeneous subgroup of the same phenotypical(clinical) condition, to further study the unknown underlying pathogenesis of various mental illnesses. Finally, RIS may be a useful alternative or adjunctive drug for patients with mood disorders without psychotic features or refractory to treatment with standard antipsychotic drugs. The more conservative doses(tirated slowly from 1-3 mg/d) of RIS, and maintenance of mood stabilizer in the cases with risk factors of RIM are recommended in mood disorder.

  • PDF

Effects of Gamma Irradiation on Chemical Composition, Antinutritional Factors, Ruminal Degradation and In vitro Protein Digestibility of Full-fat Soybean

  • Taghinejad, M.;Nikkhah, A.;Sadeghi, A.A.;Raisali, G.;Chamani, M.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.4
    • /
    • pp.534-541
    • /
    • 2009
  • The aim of this study was to evaluate the effects of gamma irradiation (${\gamma}$-irradiation) at doses of 15, 30 and 45 kGy on chemical composition, anti-nutritional factors, ruminal dry matter (DM) and crude protein (CP) degradibility, in vitro CP digestibility and to monitor the fate of true proteins of full-fat soybean (SB) in the rumen. Nylon bags of untreated or ${\gamma}$-irradiated SB were suspended in the rumens of three ruminally-fistulated bulls for up to 48 h and resulting data were fitted to a nonlinear degradation model to calculate degradation parameters of DM and CP. Proteins of untreated and treated SB bag residues were fractionated by sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE). Digestibility of rumen undegraded CP was estimated using the three-step in vitro procedure. The chemical composition of raw and irradiated soybeans was similar. Results showed that phytic acid in ${\gamma}$-irradiated SB at dose of 30 kGy was eliminated completely. The trypsin inhibitor activity of 15, 30 and 45 kGy ${\gamma}$-irradiated SB was decreased (p<0.01) by 18.4, 55.5 and 63.5%, respectively. From in sacco results, ${\gamma}$-irradiation decreased (p<0.05) the washout fractions of DM and CP at doses of 30 and 45 kGy, but increased (p<0.05) the potentially degradable fractions. Gamma irradiation at doses of 15, 30 and 45 kGy decreased (p<0.05) effective degradability of CP at a rumen outflow rate of 0.05 $h^{-1}$ by 4.4, 14.4 and 26.5%, respectively. On the contrary, digestibility of ruminally undegraded CP of irradiated SB at doses of 30 and 45 kGy was improved (p<0.05) by 12 and 28%, respectively. Electrophoretic analysis of untreated soybean proteins incubated in the rumen revealed that ${\beta}$-conglycinin subunits had disappeared at 2 h of incubation time, whereas the subunits of glycinin were more resistant to degradation until 16 h of incubation. From the SDS-PAGE patterns, acidic subunits of 15, 30 and 45 kGy ${\gamma}$-irradiated SB disappeared after 8, 8 and 16 h of incubation, respectively, while the basic subunits of glycinin were not degraded completely until 24, 48 and 48 h of incubation, respectively. It was concluded that ${\gamma}$-irradiated soybean proteins at doses higher than 15 kGy could be effectively protected from ruminal degradation.

EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM PANORAMIC RADIOGRAPHY TO THE CRITICAL ORGANS OF HEAD AND NECK REGION (파노라마 촬영시의 두경부 주요기관의 등가선량, 유효선량 및 위험도)

  • Cho Bong-Hae;Nah Kyung-Soo;Lee Ae-Ryeon
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.437-445
    • /
    • 1995
  • The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. the equivalent and effective dose in adult mode were 837μSv and 20.93μSv, those in child mode were 462μSv and 11.54μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.21μSv in adult mode, 20.14μSv in child mode. From these datas, the probabilities of stochastic effect from adult and child mode were 2.50x10/sup -6/ and 1.47x10/sup -6/. 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million panoramic examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult and child mode from these examinations.

  • PDF

Analysis of Exposure Doses and Determination of Atmospheric Diffusion Coefficients (피폭선량 해석과 대기확산계수 결정)

  • Kim, Byung-Woo;Han, Moon-Hwee;Lee, Young-Bok;Lee, Jeong-Ho
    • Journal of Radiation Protection and Research
    • /
    • v.9 no.1
    • /
    • pp.26-32
    • /
    • 1984
  • The exposure doses by the radioactive gaseous effluents from nuclear power plants are investigated in the two cases of normal operation and hypothetical accident. Gaussian equation is adapted in the normal operation as the diffusion model of effluents for long period, which uses annual average meteorological data. But the real time models have been used in the case of accidents which analyze the changes of wind direction and speed. In this study the annual exposure doses by the normal operation of Kori unit 1 during $1977{\sim}1982$ were calculated on the basis of the atmospheric diffusion factor by the Gaussian straight line model. And the image processing technique was suggested as the effective method through the wind tunnel experiments to get the characteristic value of atmospheric diffusion coefficient required especially in the accidents of nuclear power plants.

  • PDF

Studies on the Preservation of Korean Rice by Gamma-irradiation (III) On disinfection of rice by gamma-ray irradiation (감마선 조사에 의한 쌀 저장에 관한 연구(제 3 보))

  • Kim, Hyong-Soo;Choi, Yong-Rack;Kim, Sung-Kih;Harn, In-Ja
    • Korean Journal of Food Science and Technology
    • /
    • v.2 no.1
    • /
    • pp.113-120
    • /
    • 1970
  • For the purpose of disinfection and efficient storage, Korean Paldal variety rice was hulled into the unpolished and polished ones and packed in the kraft paper bags, irradiated with relatively high doses, 500, 800, and 1,000 krad from the $CO^{60}$ source and stored at room temperature, a variety of changes were observed as follows. 1) With 1,000 krad irradiation, mold was almost sterilized. 2) Fat acidity increased during storage and continued to increase more with increased doses. 3) The content of riboflavin eras severely reduced with higher doses. 4) The results of organoleptic test were featured by a yellow color and a keen irradiation odor appearing in the boiled rice. 5) In the irradiated rice starch with 3,000 krad, hydrolysis with ${\alpha}$-amylase was not effective while accelerated with diastase.

  • PDF