• 제목/요약/키워드: effective dose equivalent

검색결과 99건 처리시간 0.037초

안티몬 차폐시트의 감마선 차폐 성능평가 (Performance Evaluation of Gamma ray Shielding of Antimony Shielding Sheet)

  • 한상현
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제41권2호
    • /
    • pp.135-140
    • /
    • 2018
  • In this study, the dose of antimony shielding sheet was measured and the shielding rates according to the distance between the radioisotopes and the detector was analyzed according to the type of $^{99m}Tc$, $^{18}F$, $^{201}Tl$, $^{131}I$, $^{123}I$ using the antimony shielding sheet. The detector was used with an inspector. Six sheets of 0.25 mmPb were prepared with 20 cm width and length. Measurement results using $^{99m}Tc$, $^{201}Tl$, and $^{123}I$ showed that as the thickness of the sheet became thicker, the farther the distance from the source to the sheet was, the smaller the transmitted dose amount was measured. It was analyzed that a thickness of 1.50 mm or more was required to obtain a shielding rates of 90% or more. In the experiments of $^{18}F$ and $^{131}I$, the dose value was highest when 0.25 mm sheet was used, and the shielding rates was negative, unlike the results of other radioisotopes. Since $^{201}Tl$ are used when using antimony sheet and $^{18}F$ and $^{131}I$ have no shielding effect, it is thought that it is effective to reduce dose by repeating training and simulation training so that work can be done in a short time.

라돈 환경계통의 제어 매개변수 모델링 (Modeling a Radon Environment System with Dose Sensitivity to the Controllable Parameters)

  • 주운표;김건중;장시영
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.753-756
    • /
    • 1991
  • This paper aimed to analyse dose sensitivity to the controllable parameters of in-door radon $(^{222}Rn)$ and its decay products(Rn-D) by applying the input-output linear system theory. Physical behaviors of $^{222}Rn$ & Rn-D were analyzed in terms of $^{222}Rn$ gas generation, -migation and - infiltration to indoor environments, and the performance output-function(i.e. mean dose equivalent to Tracho-Bronchial(TB) lung region was assessed to the following ranges of the controllable parameters; a) the ventilation rate constant $({\lambda}_v)$ : $0{\sun}500[h^{-1}]$. b) the attachment rate constant$({\lambda}_a)$ : 0-500 $[h^{-1}]$. c) deposition rate constant $({\lambda}{_{d}^{u}})$: 0-50$[h^{-1}]$. A linear input-output model was reconstructed from the original models in literatures, as follows, which was modified into the matrices consisting of 111 nodal equations. a) indoor ${222}Rn$ & Rn-D Behaviour: jacobi- Porstendorfer- Bruno model. b) lung dosimerty : Jacobi-Eisfeld model. Some of the major findings, which identify the effectiveness of this model, were as follows. a) ${\lambda}_v$ is most effective, dominant controllable parameters in dose reduction, if mechanical ventilation is applied. b) ${\lambda}_v$, depending on the air particle-concentration, reduces the dose somewhat within ${\lambda}_v$<1 $h^{-1}R range. However, the dose increases conversely, ${\lambda}_v$>1 $h^{-1}R range range. c) ${\lambda}{_{d}^{4}}$ reduces the dose linearly as ${\lambda}_v$ dose. Such dose(z-axis) sentivities are shown with three-dimensional plots whoes x,y-axes are combined 2out the 3 parameter${\lambda}_v{\lambda}_s,\;{\lambda}_d^s$.

  • PDF

Natural radioactivity level in fly ash samples and radiological hazard at the landfill area of the coal-fired power plant complex, Vietnam

  • Loan, Truong Thi Hong;Ba, Vu Ngoc;Thien, Bui Ngoc
    • Nuclear Engineering and Technology
    • /
    • 제54권4호
    • /
    • pp.1431-1438
    • /
    • 2022
  • In this study, natural radioactivity concentrations and dosimetric values of fly ash samples were evaluated for the landfill area of the coal-fired power plant (CFPP) complex at Binh Thuan, Vietnam. The average activity concentrations of 238U, 226Ra, 232Th and 40K were 93, 77, 92 and 938 Bq kg-1, respectively. The average results for radon dose, indoor external, internal, and total effective dose equivalent (TEDE) were 5.27, 1.22, 0.16, and 6.65 mSv y-1, respectively. The average emanation fraction for fly ash were 0.028. The excess lifetime cancer risks (ELCR) were recorded as 20.30×10-3, 4.26×10-3, 0.62×10-3, and 25.61×10-3 for radon, indoor, outdoor exposures, and total ELCR, respectively. The results indicated that the cover of shielding materials above the landfill area significantly decreased the gamma radiation from the ash and slag in the ascending order: Zeolite < PVC < Soil < Concrete. Total dose of all radionuclides in the landfill site reached its peak at 19.8 years. The obtained data are useful for evaluation of radiation safety when fly ash is used for building material as well as the radiation risk and the overload of the landfill area from operation of these plants for population and workers.

CT 영상을 이용한 불균질 조직의 선량보정 평가 (Evaluation of Corrected Dose with Inhomogeneous Tissue by using CT Image)

  • 김가중
    • 대한방사선치료학회지
    • /
    • 제18권2호
    • /
    • pp.75-80
    • /
    • 2006
  • 목 적: 방사선치료에 있어 종양조직이나 정상조직의 정확한 선량계산은 치료의 성패를 좌우하는 가장 큰 요인이다. 이로 인해 방사선치료계획은 컴퓨터 단층 영상의 재구성을 통한 불균질 조직에 선흡수계수를 밀도로 변환하여 CT 번호에 의한 선량 보정이 유효하게 이루어지고 있다. 대상 및 방법: 이에 본 연구는 불균질 조직등가 팬톰을 제작하여 현재 사용 중인 방사선 치료 계획시스템을 이용한 CT 번호의 측정과 질량밀도를 계산하여 물을 기준으로 상대값을 구하였다. 또한 실제 방사선 조사 시 측정된 선량(nC)과 CT영상을 이용한 치료계획 시 선량(PDD)을 상대적으로 비교함으로써 실제 CT 번호를 이용한 불균질 조직의 보정에 대한 유용성과 정확성을 평가하고자 한다. 결 과: 측정결과 CT 번호를 이용하여 계산된 조직등가물질의 질량밀도와 실제 질량밀도는 $0.005{\sim}0.069g/cm^3$의 차이를 보였으며, 방사선 치료계획 시 심부선량(PDD)과 방사선 치료 장치로 조사하여 측정된 선량의 상대오차는 $-2.8{\sim}+1.06%$로 3% 이내의 유효범위이내의 결과를 얻었다. 결 론: 본 실험은 CT 영상을 이용한 불균질 조직의 보정에 대한 유용성을 확인할 수 있었고, 방사선 치료 계획 장치의 정도 관리(Quality Assurance; QA)의 기본 틀을 제공할 수 있을 것으로 사료된다.

  • PDF

Assessment of occupational radiation exposure of NORM scales residues from oil and gas production

  • EL Hadji Mamadou Fall;Abderrazak Nechaf;Modou Niang;Nadia Rabia;Fatou Ndoye;Ndeye Arame Boye Faye
    • Nuclear Engineering and Technology
    • /
    • 제55권5호
    • /
    • pp.1757-1762
    • /
    • 2023
  • Radiological hazards from external exposure of naturally occurring radioactive materials (NORM) scales residues, generated during the extraction process of oil and gas production in southern Algeria, are evaluated. The activity concentrations of 226Ra, 232Th, and 40K were measured using high-purity gamma-ray spectrometry (GeHP). Mean activity concentration of 226Ra, 232Th and 40K, found in scale samples are 4082 ± 41, 1060 ± 38 and 568 ± 36 Bq kg-1, respectively. Radiological hazard parameters, such as radium equivalent (Raeq), external and internal hazard indices (Hex, Hin), and gamma index (Iγ) are also evaluated. All hazard parameter values were greater than the permissible and recommended limits and the average annual effective dose value exceeded the dose constraint (0.3 mSv y-1). However, for occasionally exposed workers, the dose rate of 0.65 ± 0.02 mSv y-1 is lower than recommended limit of 1 mSv y-1 for public.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.

6MV X-선에 의한 폐조직의 심부선량변화와 임상응용 (Dose Calculation of Heterogeneous Lung Tissue on 6MV X-ray Therapy)

  • 이경자;장승희;추성실
    • 한국의학물리학회지:의학물리
    • /
    • 제9권4호
    • /
    • pp.247-257
    • /
    • 1998
  • 방사선치료에서 악성종양과 주위건강조직에 대한 정확한 선량분포를 파악하기 위하여는 신체내 불균질 조직에 의한 선량변화의 측정이 중요하며 그중에서도 밀도가 낮고 체적이 비교적 큰 폐조직에 대한 선량분포의 변화는 방사선 치료에서 간과할 수 없는 중요한 요인의 하나이다. 저자들은 6메가볼트의 엑스선으로 흉곽내에 위치한 종양에 정확한 선량을 투여하기 위하여 조직등가팬텀을 제작하고 열형광 선량계와 필름선량측정 방법으로 흉곽내의 방사선 분포변화를 실측 하였으며 컴퓨터화하기 위한 수학적 실험식올 유도하고 이를 이론식과 비교 검토한 결과 거의 일치함을 보였다. 실험을 통하여 일문조사면 또는 다문조사면에서 폐조직은 연조직에 비하여 1cm 당 약4%의 선량 증가를 보였으며 식도부위의 회전조사에서는 균질 연조직의 등량곡선보다 15% 미만의 선량 격차가 나타났고 폐부위의 회전조사에서는 회전각도에 따라 20% 내외의 큰오차를 나타내었다. 폐암등 흉부내 종양치료에서는 폐조직 밀도에 의한 방사선 투과 및 산란으로 선량과 선량분포의 오차가 5%-20%에 이르므로 반드시 선량을 보상하여야 하며 선량분포도를 작성 평가함으로서 방사선 임상치료에 큰효과를 얻을 수 있었다.

  • PDF

유효검출양자효율과 선량을 이용한 소아 흉부 X-선 영상의 기술적인 인자에 관한 조사 (Survey of Technical Parameters for Pediatric Chest X-ray Imaging by Using Effective DQE and Dose)

  • 박혜숙;김예슬;김상태;박옥섭;전창우;김희중
    • 한국의학물리학회지:의학물리
    • /
    • 제22권4호
    • /
    • pp.163-171
    • /
    • 2011
  • 본 연구에서는 피사체에 의한 산란, 초점에 의한 흐림, 기하학적 확대도 그리고 검출기의 특성이 반영된 유효검출양자효율(effective detective quantum efficiency, eDQE)과 유효선량을 평가하여 소아 흉부 X선 촬영 시 선량의 최적화를 위한 조사조건의 영향을 평가하였다. 100, 110, 120, 150, 180 cm의 FDD (focus-to-detector distance)일 때 관전압을 40 kVp에서 90 kVp까지 10 kVp씩 증가시켜가며 동일한 유효선량일 때 eDQE를 평가하였다. 그 결과 eDQE는 다른 관전압과 비교 시60 kVp에서 가장 높은 값을 보였다. 특히, 동일한 유효선량일 때 그리드가 없을 경우 상대적으로 매우 높은 eDQE를 나타냈다. 이는 그리드에 의한 산란선의 감소가 그리드에서 흡수된 유효 광자의 손실을 보상하지 못하기 때문이다. 그리드 가 없을 경우 FDD가 증가할수록 향상된 유효변조전달함수(effective modulation transfer function, eMTF)로 인하여 eDQE는 증가하였다. 국내 대형병원들의 대부분은 15개월 소아의 흉부 X선 촬영 시 그리드와 함께 100 cm의 짧은 FDD를 사용하고 있다. 그 결과 대부분의 경우는 국내 환자선량권고량(diagnostic reference level, DRL) $100{\mu}Gy$을 초과하였다. 이는 5세 소아 흉부 X선 촬영 시 150 cm에서 180 cm 사이의 긴 FDD를 사용하지만, 15개월을 모사하고 있는 표준 소아팬텀의 흉부 X선 촬영의 경우 100 cm의 짧은 FDD를 사용했기 때문이다. 따라서, 나이에 따른 소아의 흉부 X선 촬영을 시행하기 위한 적절한 조사조건이 확립되어야 한다. 본 연구 결과는 나이에 따른 소아 선량의 권고량을 설립하는데 기초자료로 활용될 수 있을 것이다.

전 척추 전.후 방향 검사 시 AEC Mode와 Fix Mode에서 PC-Based Monte Carlo Program을 이용한 장기선량 및 유효선량 평가 (Evaluation of Organ and Effective Dose using A PC-Based Monte Carlo Program in AEC Mode and Fix Mode for the whole spine antero-posterior radiography)

  • 김정진;장성원;박장흠;이관섭;하동윤
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.23-31
    • /
    • 2012
  • There are AEC mode and fix mode to exposure when the whole spine antero-posterior radiography is done by using DR equipment. This study compared the utility of fix mode to AEC mode, by evaluating organ dose and effective dose and by examining the quality of radiographic image. GE DEFINIUM 8000 and ART-200X Rando Phantom manufactured by Flukebiometical were used for this study. The Rando phantom was set in front of wall detector of X-rays equipment. AEC mode was set at 80kVp and Fix mode was set at 80kVp, 25mAs, 32mAs, 40mAs, and 50mAs. Whole spine AP image were aquired by combining C, T-L and L-S spine images obtained through 3 exposures. When obtaining C, T-L and L-S spine images, were checked for Air kerma (mGy) value calculated by UNFORS Xi meter attached at the phantom surface of center of radiation field. The effective and organ doses were compared by PCXMC program (PC-Based Monte Carlo Program). The quality of obtained radiographic image was evaluated visually by 3 radiologists using resolution chart. When the effective doses was calculated based on tissue weighting factor of ICRP-103, 1.278mSv was measured by AEC mode, and Fix mode measured 0.405mSv at 25mAs, 0.518mSv at 32mAs, 0.649mSv at 40mAs, and 0.810mSv at 50mAS. In addition, the organ dose measured with esposure at 25mAs by Fix mode was almost equivalent to the organ dose by AEC mode, at the esophagus, thyroid, oral mucosa, salivaly glands located at the cervical spine part, while the organ dose by Fix mode was in general lower than the organ dose by AEC mode at the other organs. When Fix mode at 32mAs, 40mAs, and 50mAs was compared to AEC mode for organ dose in 26 organs, AEC mode had higher measurement in 21 organs but not for than brain, trachea, thyroid, oral mucosa, and salivaly glands which are located at the cervical spine part. The image quality evaluated by resolution test chart was much higher with AEC mode than the quality with Fix mode at all exposure conditions. However, while the image quality of cervical spine exposured at 50mAs by Fix mode was lower than the quality of AEC mode, thoraco-lumbar spine and lumbo-sacral spine were calculated and the quality was similar to AEC mode. Scoliosis occurs mainly at thoraco-lumbar and lumbo-sacral spine, not at cervical spine. Compared to AEC mode, Using the appropriate protocol (80kVp, 50mAs) of fix mode for whole spine AP radiography was thought to be useful because the image quality of the thoraco-lumar and lumbo-sacral spine was similar on AEC mode, Also organ and effective doses can be decreased with Fix mode. Therefore, It is considered that fix mode can be used properly with AEC mode for whole spine AP radiography when considering patient's body posture.

  • PDF

Feasibility Assessment of Physical Factors of Rectal Cancer Short-Course Chemoradiotherapy with Delayed Surgery

  • Koo, Jihye;Chung, Mijoo;Chung, Weon Kuu;Jin, Sunsik;Kim, Dong Wook
    • 한국의학물리학회지:의학물리
    • /
    • 제29권4호
    • /
    • pp.143-149
    • /
    • 2018
  • To verify the correlations between the clinical outcomes and physical factors of short-course chemoradiotherapy (SCRT) and long-course chemoradiotherapy (LCRT) with delayed surgery in patients with rectal cancer. Seventy-two patients with rectal cancer were enrolled in this study. Nineteen patients were treated with SCRT (25 Gy, 5 fractions) by intensity-modulated radiation therapy (IMRT), and 53 patients were treated with LCRT (50.4 Gy, 28 fractions) by three-dimensional conformal radiation therapy (3DCRT). Various physical factors for the target and organs at risk (OARs) were calculated to compare the clinical outcomes. The organ equivalent dose (OED) and lifetime attributable risk (LAR) of bowels and bladders were similar between the SCRT and LCRT groups, whereas the values of femurs were higher in the LCRT group. The equivalent uniform dose and normal tissue complication probability were higher in the LCRT than the SCRT group for most organs. Treatment complications, including anastomotic leakage, bowel adhesion, and hematologic toxicity, were not significantly different between SCRT and LCRT groups. CIs were $0.84{\pm}0.2$ and $0.61{\pm}0.1$ for SCRT and LCRT, respectively. The CVIs were $1.07{\pm}0.0$ and $1.10{\pm}0.1$, and the HIs were $0.09{\pm}0.0$ and $0.11{\pm}0.1$ for SCRT and LCRT, respectively. The sphincter-saving rates were 89.5% and 94.3% for SCRT and LCRT, respectively. The complete pathologic remission rates were 21.1% and 13.2%, and the down-staging rates were 47.4% and 26.4% for SCRT and LCRT, respectively. SCRT with IMRT is comparable to conventional LCRT in both physical indexes and clinical outcome. The preoperative SCRT, compensated by IMRT, is an effective and safe modality.