• Title/Summary/Keyword: effective dose equivalent

Search Result 99, Processing Time 0.027 seconds

A study on AC over-current breaker using thyristor (Thyristor를 이용한 교류과전류 차단에 관한 연구)

  • 박민호;심재명
    • 전기의세계
    • /
    • v.28 no.7
    • /
    • pp.49-55
    • /
    • 1979
  • This paper describes the mechanisms which breaks A.C. over-current protection in low voltage load. For the high speed over-current protection, it consists of thyristor switching circuit by forced commutation, IC logic gate controlled circuit and over-current detector with reed switch. Under various duty conditions, breacker was carried out several experiments and discussions. The results are as follows; (1) over-current cut off is possible within a quarter cycle (4ms at 60Hz) and clear is at least ten times faster than its electromechanical equivalent. (2) as the forced commutation thyristor circuit breaker has capability of high speed break, equivalent surgy current capacity of switching thyristor is increased more than twenty times of its rated current. (3) breaker using solid state dose not produce any harmful arc during switching period. Therefore the breaker above described may be considered an effective over-current protector for soli state power devices in industrial applications.

  • PDF

Epidural Morphine for Pain Control in Patients with Terminal Cancer in Hospice Ward (호스피스 병동의 암환자에서 경막외 모르핀 주입을 이용한 통증 조절)

  • Lee, Jang-Eun;Hur, Ki-Hoon;Kang, Yoo-Jin;Jeon, Yon-Soo;Lee, Ok-Kyung;Shim, Byoung-Yong;Kim, Hoon-Kyo
    • Journal of Hospice and Palliative Care
    • /
    • v.11 no.3
    • /
    • pp.136-139
    • /
    • 2008
  • Purpose: Epidural morphine infusion has been used to control pain in cancer patients whose cancer pain can not be controlled high dose intravenous morphine injection. To study the effectiveness and side effects of epidural morphine for the treatment of cancer pain in terminal patients at Hospice Ward, we evaluated the change in morphine equivalent daily dose for effectiveness and complications of epidural morphine infusion. Methods: We retrospectively analyzed 24 terminal cancer patients who were treated with continuous epidural morphine between 2001 and 2004 at Hospice Ward of St. Vincent's Hospital. Results: The median of baseline morphine equivalent daily dose was 615 mg, whereas the median dose of initial epidural morphine was 16 mg. The median of morphine daily equivalent daily dose dropped from 615 mg to 274 mg in one week after epidural morphine infusion therapy (P-value=0.000). The median survival from the time of the first catheter insertion was 35 days. In 6 patients, the catheter was removed due to complications, however the catheter was reinserted in 3 patients. Conclusion: Cancer pain management by epidural morphine infusion is very effective method with low rate of severe complication.

  • PDF

Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor (범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발)

  • Jong-kyu Cheon;Sunghwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.367-373
    • /
    • 2023
  • Aircrews and passengers are exposed to radiation from cosmic rays and secondary scattered rays generated by reactions with air or aircraft. For aircrews, radiation safety management is based on the exposure dose calculated using a space-weather environment simulation. However, the exposure dose varies depending on solar activity, altitude, flight path, etc., so measuring by route is more suggestive than the calculation. In this study, we developed an instrument to measure the cosmic radiation dose using a general-purpose Si sensor and a multichannel analyzer. The dose calculation applied the algorithm of CRaTER (Cosmic Ray Telescope for the Effects of Radiation), a space radiation measuring device of NASA. Energy and dose calibration was performed with Cs-137 662 keV gamma rays at a standard calibration facility, and good dose rate dependence was confirmed in the experimental range. Using the instrument, the dose was directly measured on the international line between Dubai and Incheon in May 2023, and it was similar to the result calculated by KREAM (Korean Radiation Exposure Assessment Model for Aviation Route Dose) within 12%. It was confirmed that the dose increased as the altitude and latitude increased, consistent with the calculation results by KREAM. Some limitations require more verification experiments. However, we confirmed it has sufficient utilization potential as a cost-effective measuring instrument for monitoring exposure dose inside or on personal aircraft.

Estimation of radiostrontium, radiocesium and radiobarium transfer from arid soil to plant: A case study from Kuwait

  • Aba, Abdulaziz;Ismaeel, Anfal;Al-Boloushi, Omar
    • Nuclear Engineering and Technology
    • /
    • v.53 no.3
    • /
    • pp.960-966
    • /
    • 2021
  • A technical approach to design and carry out an experiment to determine the uptake of selected radionuclides in site-specific conditions in Kuwait was developed and successfully executed for developing a radioecological decision support system. The radionuclides from soil-to-plant transfer factors have been obtained for leafy and non-leafy vegetables, and root crops cultivated in Kuwait. Two types of vegetated soils were selected and spiked with high concentrations of three relatively short-lived selected radionuclides (85Sr, 134Cs, and 133Ba). The highest strontium and barium transfer factors were found in the order: leafy vegetables > root crops > non-leafy vegetables. The approximate range of radiocesium transfer factor was found to be low in all plant groups and was comparable to those reported elsewhere in different soil types of temperate and tropical environments. A strong negative correlation between the obtained transfer factors and the distribution coefficient of the radionuclide in soil was found. It is recommended to adopt the newly derived parameters for the sensitive areas in Kuwait and other Gulf countries instead of using the generic parameters, whenever dose calculation codes are used. This will help to more accurately assess and predict the end results of the committed effective dose equivalent through ingestion pathway.

Implantation of an Intrathecal Drug Administration System -A report of two cases- (척수강 내 약물 주입기의 이식 -증례보고-)

  • Lee, Sang Jin;Nam, Sang Kun;Kim, Jang Hyun;Kim, Hyun Joo;Lee, Sang Chul;Kim, Yong Chul
    • The Korean Journal of Pain
    • /
    • v.22 no.1
    • /
    • pp.68-73
    • /
    • 2009
  • Opioids profoundly inhibit evoked discharges of spinal nociceptive neurons, thereby inhibiting the transmission of pain. Intrathecal administration of opioids using implantable continuous infusion systems is an effective method of pain relief when other treatments have failed, as well as for patients with adequate analgesia on high dose therapy that produces unacceptable side effects. We report two cases of intrathecal pump implantation performed in patients suffering from intractable chronic pain. A test dose of 3 mg morphine was injected into the epidural space. No side effects were noted and patients experienced considerable pain relief. Implantation was performed one day after the test. The initial intrathecal morphine delivery dose was half of the equivalent dose of daily oral intake opioids and the infusion rate was increased gradually under close observation for opioid side effects. Two days post-implantation, both patients were discharged without any complications.

Analysis on the Calculated Dose in the Lung Radiation Surgery Planning Using TomoTherpay (토모테라피를 이용한 폐종양 방사선수술 계획 시 선량 분석)

  • Song, Ju-Young;Jung, Jae-Uk;Yoon, Mee-Sun;Ahn, Sung-Ja;Chung, Woong-Ki;Nah, Byung-Sik;Nam, Taek-Keun
    • Progress in Medical Physics
    • /
    • v.22 no.4
    • /
    • pp.178-183
    • /
    • 2011
  • The applicability and feasibility of TomoTherapy in the lung radiation surgery was analyzed by comparison of the calculated dose distribution in TomoTherapy planning with the results of conventional IMRS (intensity modulated radiation surgery) using LINAC (linear accelerator). The acquired CT (computed tomograph) images of total 10 patients whose tumors' motion were less than 5 mm were used in the radiation surgery planning and the same prescribed dose and the same dose constraints were used between TomoTherapy and LINAC. The results of TomoTherapy planning fulfilled the dose requirement in GTV (gross tumor volume) and OAR (organ at risk) in the same with the conventional IMRS using LINAC. TomoTherapy was superior in the view point of low dose in the normal lung tissue and conventional LINAC was superior in the dose homogeneity in GTV. The calculated time for treatment beam delivery was long more than two times in TomoTherapy compared with the conventional LINAC. Based on the results in this study, TomoTherapy can be evaluated as an effective way of lung radiation surgery for the patients whose tumor motion is little when the optimal planning is produced considering patient's condition and suitability of dose distribution.

Bolus Effect to Reduce Skin Dose of the Contralateral Breast During Breast Cancer Radiation Therapy (유방암 방사선치료 시 반대편 유방의 피부선량 감소를 위한 볼루스 효과)

  • Won, Young Jin;Kim, Jong Won;Kim, Jung Hoon
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.289-295
    • /
    • 2017
  • The aim of this study was to evaluate the dose comparison using Radon phantom with 5 mm and 10 mm tissue equivalent materials, FIF, Wedge(15, 30 angle) and IMRT, to reduce the skin dose of the contralateral breast during breast cancer radiation therapy(Total dose: 50.4Gy). The dose was measured for each treatment plan by attaching to the 8 point of the contralateral breast of the treated region using a optical-stimulated luminance dosimeter(OSLD) as a comparative dose evaluation method. Of the OSLD used in the study, 10 were used with reproducibility within 3%. As a result, the average reduction rates of 5 mm and 10 mm in the FIF treatment plan were 37.23 cGy and 41.77 cGy, respectively, and the average reduction rates in the treatment plan using Wedge $15^{\circ}$ were 70.69 cGy and 87.57 cGy, respectively. The IMRT showed a reduction of 67.37 cGy and 83.17 cGy, respectively. The results of using bolus showed that as the thickness of the bolus increased in all treatments, the dose reduction increased. We concluded that mastectomy as well as general radiotherapy for breast cancer would be very effective for patients who are more likely to be exposed to scattered radiation due to a more demanding or complex treatment plan.

Evaluation of an Education Program for Patients with Asthma who use Inhalers (천식 환자를 위한 흡입기 교육 프로그램의 효과)

  • Lee, Jong-Kyung;Yang, Young-Hee
    • Journal of Korean Academy of Nursing
    • /
    • v.40 no.2
    • /
    • pp.202-212
    • /
    • 2010
  • Purpose: This study was done to evaluate the effectiveness of an education program for patients with asthma who use inhalers. Methods: The research design for this study was a non-equivalent control group quasi-experimental study. Participants in this study were 36 patients for the control group, and 43 patients for the experimental group. The experimental group participated in the education program. The control group received the usual care. Data were collected before and 1 month and 2 months after the program finished and were analyzed using the SPSS 12.0 program. Results: The experimental group had significantly higher scores of knowledge of inhalers, and inhalation technique compared to the control group. However, no significant differences were found between two groups for PEFR, asthma instability, and satisfaction with inhalers. Conclusion: According to the results, the education program was effective in improving knowledge of inhalers, and inhalation technique. Therefore, it is recommended that this education program be used in clinical practice as an effective nursing intervention for patients with asthma on inhalers.

BRCA1 and TP53 Gene-Mutations: Family Predisposition and Radioecological Risk of Developing Breast Cancer

  • Apsalikov, Bakytbek;Manambaeva, Zukhra;Ospanov, Erlan;Massabayeva, Meruyert;Zhabagin, Kuantkan;Zhagiparova, Zhanar;Maximov, Vladymir;Voropaeva, Elena;Apsalikov, Kazbek;Belikhina, Tatiana;Abdrahmanov, Ramil;Cherepkova, Elena;Tanatarov, Sayat;Massadykov, Adilzhan;Urazalina, Naylia
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.17 no.8
    • /
    • pp.4059-4062
    • /
    • 2016
  • Frequencies of polymorphisms of genes BRCA1 and ТР53 in breast cancer (BC) patients with a BC family history and radiation history were assessed and compared in the Semey region of Kazakhstan. The study included 60 women directly irradiated by the activities of the Semipalatinsk test site with a calculated effective equivalent dose of 500 mSv and their first generation descendants (group BC+Her+Exp); 65 women with family BC and absence of radiological history - the effective equivalent dose due to anthropogenic sources not exceeding 50 mSv (group BC+Her-Exp). The comparison group consisted of 65 women patients with breast cancer without family and radiological history (BC-Her-Exp). The control group comprised 60 women without breast cancer and without family and radiological history (nonBC). We carried out the genotyping of the polymorphisms c.2311T>C, c.4308T>C and 5382insC of the BRCA1 gene and rs1042522 of the ТР53 gene. The frequency of the polymorphism c.2311T>C was significantly higher in patients of the group BC+Her+Exp than in healthy women, and of the polymorphism 5382insC in BC+Her+Exp compared to all other groups. The frequency of the rs1042522 polymorphism of ТР53 was significantly higher in all groups of patients with breast cancer compared with the control group. Differences between groups of women with breast cancer were significant only in BC+Her+Exp vs. BC+Her-Exp. Combinations of polymorphisms of the genes BRCA1 and TP53 predominated in women with a family and radiological history.

Internal Dose Assessment of Worker by Radioactive Aerosol Generated During Mechanical Cutting of Radioactive Concrete (원전 방사성 콘크리트 기계적 절단의 방사성 에어로졸에 대한 작업자 내부피폭선량 평가)

  • Park, Jihye;Yang, Wonseok;Chae, Nakkyu;Lee, Minho;Choi, Sungyeol
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.157-167
    • /
    • 2020
  • Removing radioactive concrete is crucial in the decommissioning of nuclear power plants. However, this process generates radioactive aerosols, exposing workers to radiation. Although large amounts of radioactive concrete are generated during decommissioning, studies on the internal exposure of workers to radioactive aerosols generated from the cutting of radioactive concrete are very limited. In this study, therefore, we calculate the internal radiation doses of workers exposed to radioactive aerosols during activities such as drilling and cutting of radioactive concrete, using previous research data. The electrical-mobility-equivalent diameter measured in a previous study was converted to aerodynamic diameter using the Newton-Raphson method. Furthermore, the specific activity of each nuclide in radioactive concrete 10 years after nuclear power plants are shut down was calculated using the ORIGEN code. Eventually, we calculated the committed effective dose for each nuclide using the IMBA software. The maximum effective dose of 152Eu constituted 83.09% of the total dose; moreover, the five highest-ranked elements (152Eu, 154Eu, 60Co, 239Pu, 55Fe) constituted 99.63%. Therefore, we postulate that these major elements could be measured first for rapid radiation exposure management of workers involved in decommissioning of nuclear power plants, even if all radioactive elements in concrete are not considered.