• 제목/요약/키워드: effective dose

검색결과 2,494건 처리시간 0.025초

EFFECTIVE DOSE MEASUREMENT FOR CONE BEAM COMPUTED TOMOGRAPHY USING GLASS DOSIMETER

  • Moon, Young Min;Kim, Hyo-Jin;Kwak, Dong Won;Kang, Yeong-Rok;Lee, Man Woo;Ro, Tae-Ik;Kim, Jeung Kee;Jeong, Dong Hyeok
    • Nuclear Engineering and Technology
    • /
    • 제46권2호
    • /
    • pp.255-262
    • /
    • 2014
  • During image-guided radiation therapy, the patient is exposed to unwanted radiation from imaging devices built into the medical LINAC. In the present study, the effective dose delivered to a patient from a cone beam computed tomography (CBCT) machine was measured. Absorbed doses in specific organs listed in ICRP Publication 103 were measured with glass dosimeters calibrated with kilovolt (kV) X-rays using a whole body physical phantom for typical radiotherapy sites, including the head and neck, chest, and pelvis. The effective dose per scan for the head and neck, chest, and pelvis were $3.37{\pm}0.29$, $7.36{\pm}0.33$, and $4.09{\pm}0.29$ mSv, respectively. The results highlight the importance of the compensation of treatment dose by managing imaging dose.

파노라마 촬영시의 두경부 주요기관의 등가선량, 유효선량 및 위험도 (EQUIVALENT DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM PANORAMIC RADIOGRAPHY TO THE CRITICAL ORGANS OF HEAD AND NECK REGION)

  • 조봉혜;나경수;이애련
    • 치과방사선
    • /
    • 제25권2호
    • /
    • pp.437-445
    • /
    • 1995
  • The purpose of this study was to evaluate the equivalent and effective dose, and estimate radiation risk to the critical organs of head and neck region from the use of adult and child mode in panoramic radiography. The results were as follows. 1. The salivary glands showed the highest equivalent and effective dose in adult and child mode. the equivalent and effective dose in adult mode were 837μSv and 20.93μSv, those in child mode were 462μSv and 11.54μSv, respectively. 2. Total effective doses to the critical head and neck organs were estimated 34.21μSv in adult mode, 20.14μSv in child mode. From these datas, the probabilities of stochastic effect from adult and child mode were 2.50x10/sup -6/ and 1.47x10/sup -6/. 3. The other remainder showed the greatest risk of fatal cancer. The risk estimate were 4.5 and 2.7 fatal malignancies in adult and child mode from million panoramic examinations. The bone marrow and thyroid gland showed about 0.1 fatal cancer in adult and child mode from these examinations.

  • PDF

Derivation of a new dose constraint applicable to radioactive discharges from Korean nuclear power plants through retrospective dose assessment

  • Kim, Soyun;Cheong, Jae Hak
    • Nuclear Engineering and Technology
    • /
    • 제54권10호
    • /
    • pp.3660-3671
    • /
    • 2022
  • A new methodology to derive a dose constraint for radioactive effluent from a unit of nuclear power plant (NPP) through retrospective assessment was developed to reflect operational flexibility in line with international standards. The new dose constraint can retain the safety margin between the offsite dose and the past dose constraints. As case studies, the new approach was applied to 24 Korean NPPs to address the limitations of the existing seven dose constraints that do not fully comply with current international radiation protection standards. Therefore, an effective dose constraint for Korean NPPs was proposed as no less than 0.15 mSv/y, which is comparable to the international practices and previous studies (0.05-0.3 mSv/y). Although the lower bound of the equivalent dose constraint was calculated as 0.17 mSv/y, it is not proposed in this study since the compliance with the derived effective dose constraint can prevent accompanied equivalent doses to any organs from exceeding equivalent dose limits. The new framework and the case studies are expected to contribute toward and support the revision of existing dose constraints for radioactive effluent from NPPs, ensuring better compliance with the current international safety standards as well as reflect the operational flexibility in practice.

Glass dosimeter와 PCXMC Program을 이용한 소아피폭선량 측정 및 분석 (Measurement and Analysis of Pediatric Patient Exposure Dose Using Glass dosimeter and a PC-Based Monte Carlo Program)

  • 김영은;이정화;홍선숙;이관섭
    • 대한디지털의료영상학회논문지
    • /
    • 제14권2호
    • /
    • pp.9-14
    • /
    • 2012
  • Exposed dose of young child should be managed necessarily. Young child is more sensitive than adult of a Radioactivity, especially, and lives longer than adult. Must reduce exposed dose which follows The ALARA(As Low As Reasonably Achievable)rule is recommended by ICRP(International Commission on Radiological Protection)within diagnostic useful range. Therefore, We have to prepare Pediatric DRL(Diagnostic Reference Level) in Korea as soon as possible. Consequently, in this study, wish to estimate organ dose and effective dose using PCXMC Program(a PC-Based Monte Carlo Program), and measure ESD(Entrance surface dose)and organ dose using Glass dosimeter, and then compare with DRL which follows EC(European Commission)and NRPB(National Radiological Protection Board). Using glass dosimeter and PCXMC programs conforming to the International Committee for Radioactivity Prevention(ICRP)-103 tissue weighting factor based on the item before the organs contained in the Chest, Skull, Pelvis, Abdomen in the organ doses and effective dose and dose measurements were evaluated convenience. In a straightforward way to RANDO phantom inserted glass dosimeter(GD352M)by using the hospital pediatric protocol, and in a indirect way was PCXMC the program through a virtual simulation of organ doses and effective dose were calculated. The ESD in Chest PA is 0.076mGy which is slightly higher than the DRL of NRPB(UK) is 0.07mGy, and is lower than the DRL of EC(Europe) which is 0.1mGy. The ESD in Chest Lateral is 0.130mGy which is lower than the DRL of EC(Europe) is 0.2mGy. The ESD in Skull PA is 0.423mGy which is 40 percent lower than the DRL of NRPB(UK) is 1.1mGy and is 28 percent lower than the DRL of EC(Europe) is 1.5mGy. The ESD in Skull Lateral is 0.478mGy which is half than the DRL of NRPB(UK) is 0.8mGy, is 40 percent lower than the DRL of EC(Europe) is 1mGy. The ESD in Pelvis AP is 0.293mGy which is half than the DRL of NRPB(UK) is 0.60mGy, is 30 percent lower than the DRL of EC(Europe)is 0.9mGy. Finally, the ESD in Abdomen AP is 0.223mGy which is half than the DRL of NRPB(UK) is 0.5mGy, and is 20 percent lower than the DRL of EC is 1.0mGy. The six kind of diagnostic radiological examination is generally lower than the DRL of NRPB(UK)and EC(Europe) except for Chest PA. Shouldn't overlook the age, body, other factors. Radiological technician must realize organ dose, effective dose, ESD when examining young child in hospital. That's why young child is more sensitive than adult of a Radioactivity.

  • PDF

Multi-layers grid environment modeling for nuclear facilities: A virtual simulation-based exploration of dose assessment and dose optimization

  • Jia, Ming;Li, Mengkun;Mao, Ting;Yang, Ming
    • Nuclear Engineering and Technology
    • /
    • 제52권5호
    • /
    • pp.956-963
    • /
    • 2020
  • Dose optimization for Radioactive Occupational Personal (ROP) is an important subject in nuclear and radiation safety field. The geometric environment of a nuclear facility is complex and the work area is radioactive, so traditional navigation model and radioactive data field cannot form an effective environment model for dose assessment and dose optimization. The environment model directly affects dose assessment and indirectly affects dose optimization, this is an urgent problem needed to be solved. Therefore, this paper focuses on an environment model used for Dose Assessment and Dose Optimization (DA&DO). We designed a multi-layer radiation field coupling modeling method, and then explored the influence of the environment model to DA&DO by virtual simulation. Then, a simulation test is done, the multi-layer radiation field coupling model for nuclear facilities is demonstrated to be effective for dose assessment and dose optimization through the experiments and analysis.

두경부 전산화 단층촬영시의 주요 장기선량, 유효선량 및 위험도 (ORGAN DOSE, EFFECTIVE DOSE AND RISK ASSESSMENT FROM COMPUTED TOMOGRAPHY TO HEAD AND NECK REGION)

  • 김애지;조봉혜;나경수
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.27-38
    • /
    • 1995
  • The organ or tissue doses were determined with head and neck phantom measurement for multiple axial scans (36 slices), multiple coronal scans (13 slices), 3 types of single axial scans(orbit, maxillary sinus and mandibular canal) and single coronal scan (maxillary sinus). For each scan sequence 30 TLDs were placed in selected sites(16 internal sites and 14 external sites) in a tissue-equivalent phantom. The exposure was made at 120kVp, 500mAs with 5 mm slice width. The results were as follows : 1. In multiple axial scans, the greatest effective dose recorded was that delivered to the thyroid glands(2.77 mSv) and the least was that received by the skin(0.05 mSv). From these data, stochastic effects were 202.2x10/sup -6/ and 3.7×10/sup -6/, respectively. 2. In multiple coronal scans, the greatest effective dose recorded was that delivered to the salivary glands(0.58 mSv) and the least was that received by the skin(0.01 mSv). From these data, stochastic effects were 42.2×10/sup -6/ and 0.7×10/sup -6/, repectively. 3. Among single axial scans, the greatest effective dose recorded was that delivered to the salivary gland(0.38 mSv) in maxillary sinus scan. From this data, stochastic effect was 27.7×10/sup -6/. 4. In single coronal scan, the greatest effective dose recorded was that delivered to the salivary gland(0.01 mSv). From this data, stochastic effect was 1.0×10/sup -6/. 5. The equivalent dose measured that delivered to the lens of the eyes was 69.64 mSv in multiple axial scan, 39.32 mSv in multiple coronal scan and 36.77 mSv in single axial scan(orbit).

  • PDF

모나자이트 취급공정에서의 라돈 및 토론 노출 특성 (Characteristics of Internal and External Exposure of Radon and Thoron in Process Handling Monazite)

  • 정은교
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.167-175
    • /
    • 2019
  • Objectives: The purpose of this study was to evaluate airborne radon and thoron levels and estimate the effective doses of workers who made household goods and mattresses using monazite. Methods: Airborne radon and thoron concentrations were measured using continuous monitors (Rad7, Durridge Company Inc., USA). Radon and thoron concentrations in the air were converted to radon doses using the dose conversion factor recommended by the Nuclear Safety and Security Commission in Korea. External exposure to gamma rays was measured at the chest height of a worker from the source using real-time radiation instruments, a survey meter (RadiagemTM 2000, Canberra Industries, Inc., USA), and an ion chamber (OD-01 Hx, STEP Co., Germany). Results: When using monazite, the average concentration range of radon was $13.1-97.8Bq/m^3$ and thoron was $210.1-841.4Bq/m^3$. When monazite was not used, the average concentration range of radon was $2.6-10.8Bq/m^3$ and the maximum was $1.7-66.2Bq/m^3$. Since monazite has a higher content of thorium than uranium, the effects of thoron should be considered. The effective doses of radon and thoron as calculated by the dose conversion factor based on ICRP 115 were 0.26 mSv/yr and 0.76 mSv/yr, respectively, at their maximum values. The external radiation dose rate was $6.7{\mu}Sv/hr$ at chest height and the effective dose was 4.3 mSv/yr at the maximum. Conclusions: Regardless of the use of monazite, the total annual effective doses due to internal and external exposure were 0.03-4.42 mSv/yr. Exposures to levels higher than this value are indicated if dose conversion factors based on the recently published ICRP 137 are applied.

PCXMC 소프트웨어를 이용한 소아에서의 CBCT 환자선량 평가 (Dose estimation of cone-beam computed tomography in children using personal computer-based Monte Carlo software)

  • 김은경
    • 대한치과의사협회지
    • /
    • 제58권7호
    • /
    • pp.388-397
    • /
    • 2020
  • Objective: The purpose of the study was to calculate the effective and absorbed organ doses of cone-beam computed tomography (CBCT) in pediatric patient using personal computer-based Monte Carlo (PCXMC) software and to compare them with those measured using thermoluminescent dosimeters (TLDs) and anthropomorphic phantom. Materials and Methods: Alphard VEGA CBCT scanner was used for this study. A large field of view (FOV) (20.0 cm × 17.9 cm) was selected because it is a commonly used FOV for orthodontic analyses in pediatric patients. Ionization chamber of dose-area product (DAP) meter was located at the tube side of CBCT scanner. With the clinical exposure settings for a 10-year-old patient, DAP value was measured at the scout and main projection of CBCT. Effective and absorbed organ doses of CBCT at scout and main projection were calculated using PCXMC and PCXMCRotation software respectively. Effective dose and absorbed organ doses were compared with those obtained by TLDs and a 10-year-old child anthropomorphic phantom at the same exposure settings. Results: The effective dose of CBCT calculated by PCXMC software was 292.6 μSv, and that measured using TLD and anthropomorphic phantom was 292.5 μSv. The absorbed doses at the organs largely contributing to effective dose showed the small differences between two methods within the range from -18% to 20%. Conclusion: PCXMC software might be used as an alternative to the TLD measurement method for the effective and absorbed organ dose estimation in CBCT of large FOV in pediatric patients.

  • PDF

국내 흉부 X-선 검사에 따른 유효선량 계산 (Calculation of Effective Dose on Domestic Chest PA X-ray Examinations)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제12권7호
    • /
    • pp.827-832
    • /
    • 2018
  • 대규모 데이터에 기반한 실제 사용 조건의 장기유효선량 분석 연구는 부족하다. 본 연구에서는 국내 324개 의료기관에서 사용하는 흉부 X건 검사의 노출조건에 대해 전산모사를 이용한 장기선량을 계산하고 평가하였다. 실험결과, 저에너지 파라미터 대역에서 유효선량은 0.024 mSv이고 비장, 부신, 폐 순으로 높았다. 고에너지 노출파라미터 대역에서 유효선량은 0.123 mSv이고 신장, 비장, 부신 순으로 높게 나왔다. Park의 연구에서 제안한 화질과 피폭을 고려한 최적의 조건을 사용했을 때 유효선량은 0.017 mSv 로 나타났다. 사용 에너지가 높아질수록 장기 전체의 유효선량이 높아지고 그 중 신장이 가장 크게 증가하였다. 연구결과는 흉부X선 검사 시 참고자료가 되고 환자 피폭저감에 도움을 줄 것이다.

Digital Chest Tomosynthesis에서 부가필터에 따른 화질 및 유효선량 (Comparison of Image Quality and Effective Dose by Additional Filtration on Digital Chest Tomosynthesis)

  • 김계선;김성철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제38권4호
    • /
    • pp.347-353
    • /
    • 2015
  • 디지털 흉부단층합성법 검사에서 부가필터 사용에 따른 환자의 선량과 화질의 특성을 비교해보고자 하였다. 부가필터의 종류는 구리, 알루미늄, 니켈을 사용하였으며, 이 때 각 각의 부가필터에 따른 유효선량, 면적선량을 측정해 보았고, 화질의 물리적 평가방법으로 signal to noise ratio (SNR)과 contrast to noise ratio (CNR)을, 시각적 평가방법으로 contrast detail (CD) phantom을 이용한 CD 곡선을 비교하였다. 그 결과 부가필터별 조사선량이 비슷한 두께는 0.3 mmCu, 3 mmAl, 0.3 mmNi 였으며 부가필터를 사용하지 않았을 때 보다 조사선량 값이 평균 33.1% 감소하였다. 각 필터 별 dose area product (DAP) 선량값을 측정한 결과 Ni를 사용하였을 때 선량이 72.9% 감소하여 가장 낮았으며, 필터별 DAP 값은 통계적으로 유의한 차이를 보였다(p<0.01). 유효선량은 Ni를 사용하였을 때 가장 낮은 선량 값을 보였고, 필터를 사용하지 않았을 때 0.102 mSv에 비해 48.0% 감소하였다. CD phantom에 의한 시각적 화질평가에서는 각 필터별로 비슷한 양상을 나타냈으며, 3가지 부가필터를 사용 하였을 때 S NR과 CNR은 평균 19.07, 1 8.17% 감소함을 보였다. 결론적으로 디지털 흉부 단층합성법 검사에서 부가필터로 Ni을 사용할 경우 유효선량 및 DAP 선량 감소, 화질에서 가장 적절함을 알 수 있었다.