• Title/Summary/Keyword: effective $C/N_0$

Search Result 720, Processing Time 0.034 seconds

Clinical Results According to the Level and Extent of Sympathetic Block in Palmar Hyperhidrosis (수장부다한증에서의 교감 신경절 차단 범위 및 부위에 따른 성격 비교)

  • 오정훈
    • Journal of Chest Surgery
    • /
    • v.33 no.10
    • /
    • pp.817-822
    • /
    • 2000
  • Video assisted thoracic sympathectomy or sympathicotomy is a safe and effective therapy for the treatment of palmar hyperhidrosis with immediate symptomatic imporvement. However the degree of satisfaction may diminish with time due to cmpensatory sweating or excessive hand dryness. Therefore by comparing and assessing the degree of symptomatic improvement or compensatory sweating following sympathectomy or sympathicotomy at various levels we aim to determine the optimal level of sympathetic nerve block which will result in minimal side effects and maximal benefit. Material and Method: Among 194 patients having undergone video assisted thoracic sympathectomy or sympathicotomy between January 1996 and June 1999, 137 patients who responded to either telephone interview or questionnaire were included in the current study. The patients were divided into three groups. Group I(n=61) ; patients having undergone T2,3,4 sympathectomy group II(35) ; patients having undergone T2 sympathicotomy and group III(41) ; patients having undergone limited T2 sympathicotomy which consist of block of interganglionic neuronal fiber on the third rib. The parameters studied comprised of pre- and post-operative palmar temperature change treatment satisfaction the degree of compensatory sweating or discomfort from palmar dryness postoperative complication and changes in plantar sweating Result : There was no difference in age and sex among the groups and the mean postoperative elevation in palmar temperature was 21.59$^{\circ}C$ without any differences among the groups. Patients expressing satisfaction were 65.6%, 62.9% and 90.24% in groups I, II and III, respectively(p<0.05) Moderate to severe compensatory sweating was present in 65.6% 51.4%, and 24.39%, in group I, II, and III, respectively(p<0.05) Slight but comfortable amount of palmar humidness was expressed in decreasing order group III(41.6%) group I(24.6%) and group II(5.7%) (p<0.05) Ineffectiveness or recurrence was present in 5patients in group I(8.2%) 1 patient in group II(2.9%) and none in group III. With regards to plantar sweating decrease in sweating was expressed in 43 patients(31.4%) while similar degree of sweating in 61 patients(44.5%) and increase in sweating in another 33 patinets(24.1%) Conclusion : Limited T2 sympathicotomy resection of the lower interganglionic neuronal fiber of the second sympathetic ganglion on the third rib showed immediate effect in palmar hyperhidrosis and caused lesser compensatory sweating and hand dryness.

  • PDF

Combined Effects of Modified Atmosphere Packaging and Organic Acid Salts (Sodium Acetate and Calcium Lactate) on the Quality and Shelf-life of Hanwoo Ground Beef Patties

  • Muhlisin, Muhlisin;Kang, Sun-Moon;Choi, Won-Hee;Lee, Keun-Taik;Cheong, Sung-Hee;Lee, Sung-Ki
    • Food Science of Animal Resources
    • /
    • v.30 no.4
    • /
    • pp.685-694
    • /
    • 2010
  • The present study investigated the combined effects of modified atmosphere packaging (MAP) and organic acid salts on the quality and shelf-life of Hanwoo ground beef patties. The ground beef containing 500 ppm of ascorbic acid was prepared with air-packaging (Air-P), high oxygen-MAP (70% $O_2$+30% $CO_2$/OxyMAP), and nitrogen-MAP (100% $N_2$/NitroMAP), in combination with organic acid salts (1500 ppm of sodium acetate and 500 ppm of calcium lactate). The samples were stored for 11 d at $5^{\circ}C$. The pH value of ground beef patties decreased during storage in all the treatments. The ground beef patties with organic acid salts showed relatively higher level of pH during storage compared with non-added patties (p<0.05). Lipid oxidation was accelerated in OxyMAP while it was delayed in NitroMAP treated with organic acid salts. Nitro-MAP treated with organic acid salts was effective in stabilizing the color characteristics of lightness (CIE $L^*$) and redness (CIE $a^*$) during storage. Oxygen content in MAP was shown to be a more important factor affecting color stability and lipid oxidation of ground beef than organic acid salts. The aerobic and anaerobic bacterial counts were reduced both in OxyMAP and NitroMAP (p<0.05), and the lactic acid bacteria was inhibited by Oxy-MAP (p<0.05). Coliform bacteria decreased during storage as pH value was decreased in all treatments. According to the sensory evaluation, the ground beef patties in NitroMAP showed the best quality among all treatments during storage. Therefore, Hanwoo ground beef patties added with sodium acetate and calcium lactate and packed with NitroMAP showed better quality characteristics than other treatments. This packaging method is recommended and could be utilized for packaging hanwoo ground beef patties for improving quality and extending shelf-life.

Sensory Information Processing

  • Yoshimoto, Chiyoshi
    • Journal of Biomedical Engineering Research
    • /
    • v.6 no.2
    • /
    • pp.1-8
    • /
    • 1985
  • The wall shear stress in the vicinity of end-to end anastomoses under steady flow conditions was measured using a flush-mounted hot-film anemometer(FMHFA) probe. The experimental measurements were in good agreement with numerical results except in flow with low Reynolds numbers. The wall shear stress increased proximal to the anastomosis in flow from the Penrose tubing (simulating an artery) to the PTFE: graft. In flow from the PTFE graft to the Penrose tubing, low wall shear stress was observed distal to the anastomosis. Abnormal distributions of wall shear stress in the vicinity of the anastomosis, resulting from the compliance mismatch between the graft and the host artery, might be an important factor of ANFH formation and the graft failure. The present study suggests a correlation between regions of the low wall shear stress and the development of anastomotic neointimal fibrous hyperplasia(ANPH) in end-to-end anastomoses. 30523 T00401030523 ^x Air pressure decay(APD) rate and ultrafiltration rate(UFR) tests were performed on new and saline rinsed dialyzers as well as those roused in patients several times. C-DAK 4000 (Cordis Dow) and CF IS-11 (Baxter Travenol) reused dialyzers obtained from the dialysis clinic were used in the present study. The new dialyzers exhibited a relatively flat APD, whereas saline rinsed and reused dialyzers showed considerable amount of decay. C-DAH dialyzers had a larger APD(11.70$\pm$1.32mmHg/min)compared to CF dialyzers(4.32$\pm$0.55mmHg/min)(p<0.05). However, there was no observable difference in the UFR between the two dialyzers. Neither APD nor UFR showed any significant increase with an increasing number of reuses for up to more than 20reuses. A substantial number of failures observed in APD(larger than 20mmHe/min)on the reused dialyzers(2 out of 40 CP and S out 26 C-DAK) were attributed to the Possible damage on the fibers. The CF 15-11 HFDs which failed APD test did not show changes in the UFR compared to normal dialyzers indicating that APD is a more sensitive test than UFR test to evaluate the integrity of the fibers. 30527 T00401030527 ^x For quantitative measurement of reflected light from a clinical diagnostic strip, a prototype old reflectance photometer was designed. The strip loader and cassette were made to obtain more accurate reflectance parameters. The strip was illuminated at 45˚c through optical fiber and the intensity of reflected light was determined at rectanguLat angle using a photodiode. The kubelka-munk coefficient and reflection optical density were determined ar four different wavelengths(500, 550, 570 and 610nm) for blood glucose strip. For higher concentration than 300mg/41 about glucose, a saturation state of abforbance was observed at 500, 550 and 570nm. The correlation between glucose concentration and parameters was the best at 610nm. 30535 T00401030535 ^x Radiation-induced fibrosarcoma tumors were grown on the flanks of C3H mice. The mice were divided into two groups. One group was injected with Photofrin II, intravenously (2.5mg/kg body weight). The other group received no Photofrin II. Mice from both groups were irradialed for approximately 15 minutes at 100, 300, or 500 mW/cm2 with the argon (488nm/514.5 nm), dye(628nm) and gold vapor (pulsed 628 nm) laser light. A photosensitizer behaved as an added absorber. Under our experimental conditions, the presence of Photolfrin II increased surface temperature by at least 40% and the temperature rise due to 300 mW/cm2 irradiation exceeded values for hyperthermia. Light and temperature distributions with depth were estimated by a computer model. The model demonstrated the influence of wavelength on the thermal process and proved to be a valuable tool to investigate internal temperature rise. 30536 T00401030536 ^x We investigated the structural geometry of thirty-eight Korean femurs. The purpose of this study is to identify major geometrical differences between Korean femurs 3nd others that we believe belong to Caucasians so that we would be able to get insights into the femoral component design that fits Asians including Koreans. We utilized computerized tomography (CT) images of femurs extracted from cadavers. The CT images were transformed into bitmap data by using a film scanner, and then analyzed by using a commercially available software called Image v.1.0 and a Macintosh IIci computer.The resulting data were compared with already published data. The major results show that the geometry of the Korean femurs is significantly different from that of Caucasians: (1) the anteversion angle and the canal flare index are greater by the amount of approximately 8˚ and 0.5, respectively, (2) the shape of the isthmus cross section is more round, and (3) the distance between the teaser trochanter and the proximal border of the isthmus is shelter by about 15 mm. The results suggested that the femoral component suitable for Asians should be different from the currently-used components designed and manufactured mostly by European or American companies. 30537 T00401030537 ^x It is well known that nonlinear propagation characteristics of the wave in the tissue may give very useful information for the medical diagnoisis. In this paper, a new method to detect nonlinear propagation characteristics of the internal vibration in the tissue for the low frequency mechanical vibration by using bispectral analysis is proposed. In the method, low frequency vibration of f0( = 100Hz) is applied on the surface of the object, and the waveform of the internal vibration x (t) is measured from Doppler frequency modulation of silmultaneously transmitted probing ultrasonic waves. Then, the bispectra of the signal x (t) at the frequencies (f0, f0) and (f0, 2f0) are calculated to estimate the nonlinear propagation characteristics as their magnitude ratio, w here since bispectrum is free from the gaussian additive noise we can get the value with high S/N. Basic experimental system is constructed by using 3.0 MHz probing ultrasonic waves and the several experiments are carried out for some phantoms. Results show the superiority of the proposed method to the conventional method using power spectrum and also its usefulness for the tissue characterization. 30541 T00401030541 ^x This paper describes the implementation of a computerized radial pulse diagnosis by aids of a clinical expert. On this base, we composed of the radial pulse diagnosis system in korean traditional medicine. The system composed of a radial pulse wave detection system and a radial pulse diagnosis system. With a detection system, we detected Inyoung and Cheongu radial pulse wave and processed it. Then, we have got the characteristic parameters of radial pulse wave and also quantified that according to the method of Inyoung-Cheongu Comparison Radial Pulse Diagnosis. We defined the jugement standard of radial pulse diagnosis system and then we confirmed the possibility for realization of automatic radial pulse diagnosis in korean traditional medicine. 30545 T00401030545 ^x Microspheres are expected to be applied to biomedical areas such as solid-phase immunoassays, drug delivery systems, immunomagnetic cell separation. To synthesize microspheres for biomedical application, "two stage shot growth method" was developed. The uniformity ratio of synthesized microspheres was always smaller than 1.05. And the surface charge density (or the number of ionizable functional groups) of the microspheres synthesized by "two stage shot growth method" was 6~13 times higher than that of the microspheres synthesized by conventional seeded batch copolymerization. As a previous step for biomedical application, adsorption experiments of bovine albumin on microspheres were carried out under various conditions. The maximum adsorbed amount was obtained in the neighborhood of pH 4.5. Isoelectric point of bovine albumin is pH 5.0, so experimental result shows that it shifted to acid area. The adsorption isotherm was obtained, the plateau region was always reached at 2.Og/L (bulk concentration of bovine albumin).The effect of the kind and the amount of surface functional group was also examined. 30575 T00401030575 ^x A medical image workstation was developed using multimedia technique. The system based on PC-486DX was designed to acquire medical images produced by medical imaging instruments and related audio information, that is, doctors' reporting results. Input information was processed and analyzed, then the results were presented in the form of graph and animation. All the informations of the system were hierarchically related with the image as the apex. Processing and analysis algorithms were implemented so that the diagnostic accuracy could be improved. The diagnosed information can be transferred for patient diagnosis through LAN(local area network). 30592 T00401030592 ^x In the conventional infrared imaging system, complex infrared lens systems are usually used for directing collimated narrow infrared beams into the high speed 2-dimensional optic scanner. In this paper, a simple reflective infrared optic system with a 2-dimensional optic scanner is proposed for the realization of medical infrared thermography system. It has been experimentally proven that the intfrared thermography system composed of the proposed optic system has the temperature resolution of 0.1˚c under the spatial resolution of lmrad, the image matrix size of 256 X 240, and tile imaging time of 4 seconds. 30593 T00401030593 ^x In this paper, MIIS (Medical Image Information System) has been designed and implemented using INGRES RDBMS, which is based on a client/server architecture. The implemented system allows users to register and retrieve patient information, medical images and diagnostic reports. It also provides the function to display these information on workstation windows simultaneously by using the designed menu-driven graphic user interface. The medical image compression/decompression techniques are implemented and integrated into the medical image database system for the efficient data storage and the fast access through the network. 30594 T00401030594 ^x In this paper, computerized BEAM was implemented for the space domain analysis of EEG. Trans-formation from temporal summation to two-dimensional mappings is formed by 4 nearest point inter-polaton method. Methods of representation of BEAM are two. One is dot density method which classify brain electrical potential 9 levels by dot density of gray levels and the other is colour method which classify brain electrical 12 levels by red-green colours. In this BEAM, instantaneous change and average energy distribution over any arbitrary time interval of brain electrical activity could be observed and analyzed easily. In the frequency domain, the distribution of energy spectrum of a special band can easily be distinguished normality and abnormality. 30608 T00401030608 ^x Laboratory information system (LIS) is a key tool to manage laboratory data in clinical pathology. Our department has developed an information system for routine hematology using down-sized computer system. We have used an IBM 486 compatible PC with 16MB main memory, 210 MB hard disk drive, 9 RS-232C port and 24 pin dot printer. The operating system and database management system were SCO UNIX and SCO foxbase, respectively. For program development, we used Xbase language provided by SCO foxbase. The C language was used for interface purpose. To make the system use friendly, pull-down menu was used. The system connected to our hospital information system via application program interface (API), so the information related to patient and request details is automatically transmitted to our computer. Our system interfaced with fwd complete blood count analyzers(Sysmex NE-8000 and Coulter STKS) for unidirectional data tansmission from analyzer to computer. The authors suggests that this system based on down-sized computer could provide a progressive approach to total LIS based on local area network, and the implemented system could serve as a model for other hospital's LIS for routine hematology. 30609 T00401030609 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed a composite that is consisted of calcium phosphate and collagen. To use as the structural matrix of the composite, collagen was purified from human umbilical cord. The obtained collagen was treated by pepsin to remove telopeptides, and finally, the immune-free atelocollagen was produced: The cross linked atelocollagen was highly resistant to the collagenase induced collagenolysis. The cross linked collagen demonstrated an improved tensile strength. 30618 T00401030618 ^x This paper is a study on the design of adptive filter for QRS complex detection. We propose a simple adaptive algorithm to increase capability of noise cancelation in QRS complex detection with two stage adaptive filter. At the first stage, background noise is removed and at the next stage, only spectrum of QRS complex components is passed. Two adaptive filters can afford to keep track of the changes of both noise and QRS complex. Each adaptive filter consists of prediction error filter and FIR filter The impulse response of FIR filter uses coefficients of prediction error filter. The detection rates for 105 and 108 of MIT/BIH data base were 99.3% and 97.4% respectively. 30619 T00401030619 ^x To develop an artificial bone substitute that is gradually degraded and replaced by the regenerated natural bone, the authors designed and produced a composite that is consisted of calcium phosphate and collagen. Human umbilical cord origin pepsin treated type I atelocollagen was used as the structural matrix, by which sintered or non-sintered carbonate apatite was encapsulated to form an inorganic-organic composite. With cross linking atelocollagen by UV ray irradiation, the resistance to both compressive and tensile strength was increased. Collagen degradation by the collagenase induced collagenolysis was also decreased. 30620 T00401030620 ^x We have developed a monoleaflet polymer valve as an inexpensive and viable alternative, especially for short-term use in the ventricular assist device or total artificial heart. The frame and leaflet of the polymer valve were made from polyurethane, To evaluate the hemodynamic performance of the polymer valve a comparative study of flow dynamics past a polymer valve and a St. Jude Medical prosthetic valve under physiological pulsatile flow conditions in vitro was made. Comparisons between the valves were made on the transvalvular pressure drop, regurgitation volume and maximum valve opening area. The polymer valve showed smaller regurgitation volume and transvalvular pressure drop compared to the mechanical valve at higher heart rate. The results showed that the functional characteristics of the polymer valve compared favorably with those of the mechanical valve at higher heart rate. 30621 T00401030621 ^x Explosive evaporative removal process of biological tissue by absorption of a CW laser has been simulated by using gelatin and a multimode Nd:YAG laser. Because the point of maximun temperature of laser-irradiated gelatin exists below the surface due to surface cooling, evaporation at the boiling temperature is made explosively from below the surface. The important parameters of this process are the conduction loss to laser power absorption (defined as the conduction-to-laser power parameter, Nk), the convection heat transfer at the surface to conduction loss (defined as Bi), dimensionless extinction coefficient (defined as Br.), and dimensionless irradiation time (defined as Fo). Dependence of Fo on Nk and Bi has been observed by experiment, and the results have been compared with the numerical results obtained by solving a 2-dimensional conduction equation. Fo and explosion depth (from the surface to the point of maximun temperature) are increased when Nk and Bi are increased.To find out the minimum laser power for explosive evaporative removal process, steady state analysis has been also made. The limit of Nk to induce evaporative removal, which is proportional to the inverse of the laser power, has been obtained. 30622 T00401030622 ^x N1 and N2 gross neural action potentials were measured from the round window of the guinea pig cochlea at the onset of the acoustic stimuli. N1-N2 audiograms were made by means of regulating stimulant intensities in order to produce constant N1-N2 potentials as criteria for different input tone pip frequencies. The lowest threshold was measured with an input tone pip I5 dB SPL in intensity and 12 KHz in frequency when the animal was in normal physiological condition. The procedure of experimental measurements is explained in detail. This experimental approach is very useful for the investigation of the Cochlear function. Both noN1inear and active functions of the Cochlea can be monitored by N1-N2 audiograms. 30623 T00401030623 ^x In electrical impedance tomography(EIT), we use boundary current and voltage measurements toprovide the information about the cross-sectional distribution of electrical impedance or resistivity. One of the major problems in EIT has been the inaccessibility of internal voltage or current data in finding the internal impedance values. We propose a new image reconstruction method using internal current density data measured by NMR. We obtained a two-dimensional current density distribution within a phantom by processing the real and imaginary MR images from a 4.77 NMR machine. We implemented a resistivity mage reconstruction algorithm using the finite element method and sensitivity matrix. We presented computer simulation results of the mage reconstruction algorithm and furture direction of the research. 30624 T00401030624 ^x A new method of digital image analysis technique for discrimination of cancer cell was presented in this paper. The object image was the Thyroid eland cells image that was diagnosed as normal and abnormal (two types of abnormal: follicular neoplastic cell, and papillary neoplastic cell), respectively. By using the proposed region segmentation algorithm, the cells were segmented into nucleus. The 16 feature parameters were used to calculate the features of each nucleus. A9 a consequence of using dominant feature parameters method proposed in this paper, discrimination rate of 91.11% was obtained for Thyroid Gland cells. 30625 T00401030625 ^x An electrical stimulator was designed to induce locomotion for paraplegic patients caused by central nervous system injury. Optimal stimulus parameters, which can minimize muscle fatigue and can achieve effective muscle contraction were determined in slow and fast muscles in Sprague-Dawley rats. Stimulus patterns of our stimulator were designed to simulate electromyographic activity monitored during locomotion of normal subjects. Muscle types of the lower extremity were classified according to their mechanical property of contraction, which are slow muscle (msoleus m.) and fast muscle (medial gastrocneminus m., rectus femoris m., vastus lateralis m.). Optimal parameters of electrical stimulation for slow muscles were 20 Hz, 0.2 ms square pulse. For fast muscle, 40 Hz, 0.3 ms square pulse was optimal to produce repeated contraction. Higher stimulus intensity was required when synergistic muscles were stimulated simultaneously than when they were stimulated individually. Electrical stimulation for each muscle was designed to generate bipedal locomotion, so that individual muscles alternate contraction and relaxation to simulate stance and swing phases. Portable electrical stimulator with 16 channels built in microprocessor was constructed and applied to paraplegic patients due to lumbar cord injury. The electrical stimulator restored partially gait function in paraplegic patients. 30626 T00401030626 ^x Two-Dimensional modelling of the Cochlear biomechanics is presented in this paper. The Laplace partial differential equation which represents the fluid mechanics of the Cochlea has been transformed into two-dimensional electrical transmission line. The procedure of this transformation is explained in detail. The comparison between one and two dimensional models is also presented. This electrical modelling of the basilar membrane (BM) is clearly useful for the next approach to the further. Development of active elements which are essential in the producing of the sharp tuning of the BM. This paper shows that two-dimension model is qualitatively better than one-dimensional model both in amplitude and phase responses of the BM displacement. The present model is only for frequency response. However because the model is electrical, the two-dimensional transmission line model can be extended to time response without any difficult. 30627 T00401030627 ^x A method has been proposed for the fully automatic detection of left ventricular endocardial boundary in 2D short axis echocardiogram using geometric model. The procedure has the following three distinct stages. First, the initial center is estimated by the initial center estimation algorithm which is applied to decimated image. Second, the center estimation algorithm is applied to original image and then best-fit elliptic model estimation is processed. Third, best-fit boundary is detected by the cost function which is based on the best-fit elliptic model. The proposed method shows effective result without manual intervention by a human operator. 30628 T00401030628 ^x The intelligent trajectory control method that controls moving direction and average velocity for a prosthetic arm is proposed by pattern recognition and force estimations using EMG signals. Also, we propose the real time trajectory planning method which generates continuous accelleration paths using 3 stage linear filters to minimize the impact to human body induced by arm motions and to reduce the muscle fatigue. We use combination of MLP and fuzzy filter for pattern recognition to estimate the direction of a muscle and Hogan's method for the force estimation. EMG signals are acquired by using a amputation simulator and 2 dimensional joystick motion. The simulation results of proposed prosthetic arm control system using the EMf signals show that the arm is effectively followed the desired trajectory depended on estimated force and direction of muscle movements. 30638 T00401030638 ^x A new neural network architecture for the recognition of patterns from images is proposed, which is partially based on the results of physiological studies. The proposed network is composed of multi-layers and the nerve cells in each layer are connected by spatial filters which approximate receptive fields in optic nerve fields. In the proposed method, patterns recognition for complicated images is carried out using global features as well as local features such as lines and end-points. A new generating method of matched filers representing global features is proposed in this network. 30659 T00401030659 ^x An implementation scheme of the magnetic nerve stimulator using a switching mode power supply is proposed. By using a switching mode power supply rather than a conventional linear power supply for charging high voltage capacitors, the weight and size of the magnetic nerve stimulator can be considerably reduced. Maximum output voltage of the developed magnetic nerve stimulator using the switching mode power supply is 3, 000 volts and switching time is about 100 msec. Experimental results or human nerve stimulations using the developed stimulator are presented. 30768 T00401030768 ^x In this paper, we describe the design methodology and specifications of the developed module-based bedside monitors for patient monitoring. The bedside monitor consists of a main unit and module cases with various parameter modules. The main unit includes a 12.1" TFT color LCD, a main CPU board, and peripherals such as a module controller, Ethernet LAN card, video card, rotate/push button controller, etc. The main unit can connect at maximum three module cases each of which can accommodate up to 7 parameter modules. They include the modules for electrocardiograph, respiration, invasive blood pressure, noninvasive blood pressure, temperature, and SpO2 with Plethysmograph.SpO2 with Plethysmograph.

  • PDF

The Significance of Prophylactic Gastrojejunostomy for Patients with Unresectable Stage IV Gastric Cancer (절제 불가능한 4기 위암에서 예방적 위 공장 우회술의 의의)

  • Kim, Hwan-Soo;Kim, Chong-Suk;Kim, Jong-Han;Mok, Young-Jae;Park, Sung-Soo;Park, Seong-Heum;Jang, You-Jin;Kim, Seung-Joo
    • Journal of Gastric Cancer
    • /
    • v.9 no.4
    • /
    • pp.231-237
    • /
    • 2009
  • Purpose: The aim of this study was to evaluate the significance of palliative gastrojejunostomy for treating patients with unresectable stage IV gastric cancer, and as compared with laparotomy for treating patients with incurable gastric cancer. Materials and Methods: We retrospectively studied 167 patients who could not undergo resection without obstruction at Korea University Hospital from 1984 to 2007. They were classified into two groups, one that underwent palliative gastrojejnostomy (the bypass group, n=62) and one that underwent explo-laparotomy (the O&C group, n=105), and the clinical data and operative outcomes were compared according to the groups. Results: For the clinical characteristics, there were no differences of age, gender and liver metastasis between the bypass group and the explo-laparotomy group, but there was a significant different for the presence of peritoneal metastasis (P=0.001). There was no difference between two groups for the postoperative mortality and morbidity. For the postoperative outcomes, the duration of the hospital stay (29.25 vs 16.67) and the frequency of re-admission were not different, but the median overall survival (4.3 months vs. 3.4 months, respectively) was significantly different. By multivariate analysis, the presence of peritoneal metastasis was identified as the independent prognostic factor for incurable gastric cancer. Conclusion: A prophylactic bypass procedure is not effective for improving the quality of life and prolonging the life expectancy of unresectable stage IV gastric cancer patients without obstruction.

  • PDF

Effects of Rice Straw Particle Size on Chewing Activity, Feed Intake, Rumen Fermentation and Digestion in Goats

  • Zhao, X.G.;Wang, M.;Tan, Z.L.;Tang, S.X.;Sun, Z.H.;Zhou, C.S.;Han, X.F.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.22 no.9
    • /
    • pp.1256-1266
    • /
    • 2009
  • Effects of particle size and physical effective fibre (peNDF) of rice straw in diets on chewing activities, feed intake, flow, site and extent of digestion and rumen fermentation in goats were investigated. A 4${\times}$4 Latin square design was employed using 4 mature Liuyang black goats fitted with permanent ruminal, duodenal, and terminal ileal fistulae. During each of the 4 periods, goats were offered 1 of 4 diets that were similar in nutritional content but varied in particle sizes and peNDF through alteration of the theoretical cut length of rice straw (10, 20, 40, and 80 mm, respectively). Dietary peNDF contents were determined using a sieve for particle separation above 8 mm, and were 17.4, 20.9, 22.5 and 25.4%, respectively. Results showed that increasing the particle size and peNDF significantly (p<0.05) increased the time spent on rumination and chewing activities, duodenal starch digestibility and ruminal pH, and decreased ruminal starch digestibility and $NH_{3}$-N concentration. Intake and total tract digestibility of nutrients (i.e. dry matter, organic matter, and starch) and ruminal fermentation were not affected by the dietary particle size and peNDF. Increased particle size and peNDF did not affect ruminal fibre digestibility, but had a great impact on the intestinal and total tract fibre digestibility. The study suggested that rice straw particle size or dietary peNDF was the important influential factor for chewing activity, intestinal fibre and starch digestibility, and ruminal pH, but had minimal impact on feed intake, duodenal and ileal flow, ruminal and total tract digestibility, and ruminal fermentation.

A Clinical Evaluation of Splanchnic Nerve Block (내장신경차단에 관한 임상적 연구)

  • Kim, Soo-Yeoun;Oh, Hung-Kun;Yoon, Duek-Mi;Shin, Yang-Sik;Lee, Youn-Woo;Kim, Jong-Rae
    • The Korean Journal of Pain
    • /
    • v.1 no.1
    • /
    • pp.34-46
    • /
    • 1988
  • Intractable pain from advanced carcinoma of the upper abdomen is difficult to manage. One method used to control pain associated with these malignancies is to block off the splanchnic nerve. In 1919 Kappis described a technique by which the splanchnic nerve of the upper abdomen could be anesthetized, using a percutaneous injection. This method has been used for the relief of upper abdominal pain due to hematoma and cancer of the pancreas, stomach, gall bladder, bile duct, and colon. During the Period from November 1968 to January 1986, this method was used in 208 cases of malignancy at Severance Hospital and clinically evaluated. Patients were retroactively grouped according to the stage of development of technique used. Twelve patients who received the treatment in the period from November 1968 to March 1977 were designate4i as group 1, 26 patients from April 1977 to April 1979 as group 2, and 170 from May 1979 to January 1986 as group 3. The results are as follows: 1) The number of patients receiving splanchnic nerve block has been increasing since 1977. 2) A total of 208 patients, including 133 males and 75 females, ranging in age from 18 to 84 and averaging 51. 3) The causes of pain were stomach cancer 90, pancreatic cancer 69, and miscellaneous cancer 49 cases respectively. 4) There were 57.7% who had surgery. and 3.7% of whom had chemotherapy before the splanchnic nerve block was done. 5) These blocks were carried out with the patient in the prone position as described by Dr. Moore. For group 2 and 3, C-arm image intensifier was used. In group 1, a 22 gauze loom long needle was inserted at the lower border of the 12th rib on each aide about 7\;cm from the midline. The average distance from the midline was $6.60{\pm}0.61\;cm$ on the left side and $6.60{\pm}0.83\;cm$ on the right side in group 2, and $5.46{\pm}0.76\;cm$ on the left side and $5.49{\pm}0.69\;cm$ on the right side in group 3. The average depth to which the needle was inserted was $8.60{\pm}0.52\;cm$ on the left side and $8.74{\pm}0.60\;cm$ on the right side in group 2, and $8.96{\pm}0.63\;cm$ on the left side and $9.18{\pm}0.57\;cm$ on the right side in group 3. 6) The points of the inserted needles were positioned in the upper quarter anteriorly, 51.8% on the left side and 54.4% n the right side of the L1 vertebra by lateral roentgenogram in group 3. The inserted needle points were located in the upper and anterolateral part, of the L1 vertebra 68.5% on the left side and 60.6won the right side, on the anteroposterior rentgenogram in group 3. The needle tip was not advanced beyond the anterior margin of the vertebral body. 7) In some case of group 3, contrast media was injected before the block was done. It shows, the spread upward along the anterior mal gin of the vertebral body. 8) The concentration and the average amount of drug used in each group was as follows: In group 1, $39.17{\pm}6.69\;ml$ of 0.5% -l% lidocaine or 0.25% bupivacaine were injected for the test block and one to three days after the test block $40.00{\pm}4.26\;ml$ of 50% alcohol was injected for the semipermanent block. In group 2, $13.75{\pm}4.88\;ml$ of 1% lidocaine were used as the test block and followed by $46.17{\pm}4.37\;ml$ of 50% alcohol was injected as the semipermanent block. In group 3, $15.63{\pm}1.19\;ml$ of 1% lidocaine for test block followed by $15.62{\pm}1.20\;ml$ of pure alcohol and $16.05{\pm}2.58\;ml$ of 50% alcohol for semipermanent block were injected. 9) The result of the test block was satisfactory in all cases. However the semipermanent block was 83.3 percent of the patients in group 1 who received relief from pain for at least 2 weeks after the block, 73.1% in group 2, and 91.8% in group 3. In these unsuccessful cases, 2 cases in group 1 were controlled by narcotics but 7 cases in group 2 and 14 cases in group 3 received the same splanchnic nerve block 1 or 2 times again within 2 weeks. But, in some cases it was 3 to i months before the 2nd block and in 1 cases even 7 years. 10) The most common complications of splanchnic nerve block were hypotensino(25.5%) occasional flushing of the face, nausea, vomiting, and chest discomfort. 11) For the patients in group 3, the supplemental block most commonly used was a continuous epidural block; it was used as a diagnostic block and to afford relief from pain before the splanchnic nerve block was done. 12) The interval between the receiving of the alcohol block and discharge was from 5 to 8 days in 61 cases(31.1%) and from 1 to 2 days in 48 cases(24.5%). From the above results, it can be concluded that the splanchnic nerve block done in the prone position with pure and 50% alcohol immediately after an effective test block with 1% lidocaine under C-arm fluoroscopic control is satisfactory and reliable. How to minimize the repeat block is still a problem to be solved.

  • PDF

The effect of Sargassum confusum on reduction of body fat in obese women (알쏭이모자반 (Sargassum confusum) 주정추출물이 성인여성 체지방 감소에 미치는 영향)

  • Min, Ki Sung;Han, Daeseok;Kwon, Sang-Oh;Yeo, Kyung-Mok;Kim, Bok-Nam;Ly, Sun Yung
    • Journal of Nutrition and Health
    • /
    • v.47 no.1
    • /
    • pp.23-32
    • /
    • 2014
  • Purpose: This study was conducted in order to investigate the effect of Sargassum confusum extracts on the reduction of body fat for eight weeks in overweight women ($BMI{\geq_-}23kg/m^2$). Methods: Subjects were classified by double-blind randomized trial as the control group (C group, n = 14) and the Sargassum confusum extract supplementation group (SC group, n = 16), which consumed 12 tablets per day. Questionnaires related to their health status were assessed twice (week 0 and week 8). Their dietary intake status was evaluated by 24-recall method and body compositions were measured using a bioelectrical impedance analyzer. In addition, we assessed the anti-obesity effect and the occurrence possibility of health risk factors during the supplementation periods by hematological and clinical analysis of blood. Results: Waist circumference and body fat (%) were significantly decreased in the SC group. Serum leptin level was also significantly decreased in the SC group. Defecation frequency was significantly increased in the SC group. The above results indicate that Sargassum confusum extract supplementation improves overweight on visceral fat and blood leptin level by increasing bowel movement. These results imply a decrease of health risk factors in overweight women. Seven subjects withdrew from the study due to adverse events; however, no differences regarding adverse events were observed between the control and treatment group. Conclusion: Therefore, Sargassum confusum extract is a plausible effective agent for body fat reduction in humans.

Copolymerization of Ethylene and Norbornene via Polymethylene Bridged Dinuclear Constrained Geometry Catalysts

  • Zhu, Yin-Bang;Jeong, Eung-Yeong;Lee, Bae-Wook;Kim, Bong-Shik;Noh, Seok-Kyun;Lyoo, Won-Seok;Lee, Dong-Ho;Kim, Yong-Man
    • Macromolecular Research
    • /
    • v.15 no.5
    • /
    • pp.430-436
    • /
    • 2007
  • The dinuclear half-sandwich CGCs (constrained geometry catalyst) with a polymethylene bridge, $[Ti({\eta}^5 : {\eta}^1-indenyl)SiMe_2NCMe_3]_2(CH_2)_n]$[n = 6 (1) and 12 (2)], have been employed in the copolymerization of ethylene and norbornene (NBE). To compare the mononuclear metallocene catalysts; $Ti({\eta}^5 : {\eta}^1-2-hexylindenyl)SiMe_2NCMe_3$ (3), $(Cp^* SiMe_2NCMe_3)$Ti (Dow CGC) (4) and ansa-$Et(Ind)_2ZrCI_2$ (5), were also studied for the copolymerization of ethylene and NBE. It was found that the activity increased in the order: 1 < 2 < 3 < 5 < 4, indicating that the presence of the bridge between two the CGC units contributed to depressing the polymerization activity of the CGCs. This result strongly suggests that the implication of steric disturbance due to the presence of the bridge may playa significant role in slowing the activity. Dinuclear CGCs have been found to be very efficient for the incorporation of NBE onto the polyethylene backbone. The NBE contents in the copolymers formed ranged from 10 to 42%, depending on the polymerization conditions. Strong chemical shifts were observed at ${\delta}$42.0 and 47.8 of the isotactic alternating NBE sequences, NENEN, in the copolymers with high NBE contents. In addition, a resonance at 47.1 ppm for the sequences of the isolated NBE, EENEE, was observed in the $^{13}C-NMR$ spectra of the copolymers with low NBE contents. The absence of signals for isotactic dyad at 48.1 and 49.1 ppm illustrated there were no isotactic or microblock (NBE-NBE) sequences in the copolymers. This result indicated that the dinuclear CGCs were effective for making randomly distributed ethylene-NBE copolymers.

Effects of Mud Flat Bacteria Origin Protease Supplementation on Egg Quality, Nutrient Digestibility and Total Protein Concentration of Serum in Laying Hens (산란계에 갯벌 미생물 유래 단백질 분해 효소제의 급여가 계란 품질, 영양소 소화율 및 혈청내 총 단백질 함량에 미치는 영향)

  • Kim, H.J.;Cho, J.H.;Chen, Y.J.;Yoo, J.S.;Min, B.J.;Park, B.C.;Kim, I.H.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.4
    • /
    • pp.303-308
    • /
    • 2006
  • This study was conducted to investigate the effects of mud flat bacteria origin pretense supplementation on e99 qualify, nutrient digestibility and total protein concentration of serum in laying hens. A total of two hundred fifty two laying hens were randomly allocated into three treatments with seven replications for eight weeks. Dietary treatments included 1) CON (basal diet), 2) PRO1 (basal diet + 0.05% pretense) and 3) PRO2 (basal diet + 0.1% pretense). During the entire experimental peripd, hen-day egg production was not affected by treatments (P>0.05). Difference of yolk height was increased in PRO1 treatment compared with CON treatment (P<0.05). Difference of egg weight was increased in PRO2 treatment compared with CON and PRO1 treatments (P<0.05). Shell quality, yolk color unit, haugh unit and egg yolk index were not affected by treatments (P>0.05). DM digestibility was improved in CON and PRO2 treatments compared with PRO1 treatment (P<0.05). N digestibility was improved in PRO2 treatment compared with CON treatment (P<0.05). Total protein concentration in serum were not affected by treatments (P>0.05). In conclusion, mud flat bacteria origin pretense was effective for improving egg weight, yolk height and nutrient digestibility in laying hens.

A STUDY OF THE MECHANISM OF IMPROVING ACID RESISTANCE OF BOVINE TOOTH ENAMEL AFTER PULSED Nd-YAG LASER IRRADIATION (펄스형 Nd-YAG 레이저 조사에 의한 법랑질 내산성 증가 기전에 관한 연구)

  • Lee, Young-Soon;Shon, Heung-Kyu
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.23 no.3
    • /
    • pp.640-658
    • /
    • 1996
  • The purpose of this study was to examine the mechanism of improving acid resistance of Nd-YAG laser irradiated tooth enamel and determine the most effective energy density for improving acid resistance. The bovine tooth enamel were lased with a pulsed Nd-YAG laser. The energy densities of exposed laser beam were varied from 10 to $70\;J/cm^2$. To investigate the degree of improving acid resistance by irradiation, all the samples were submerged to demineralize in 0.5 N $HClO_4$ solution for 1 minute. After 1 minute, 0.05 % $LaCl_3$ was added to the solution for interrupting the demineralization reaction. The amounts of dissolved calcium and phosphate in the solution were measured by using an atomic absorption spectrophotometer and the UV/VIS spectrophotometer, respectively. To examine the mechanism of improving acid resistance, X-ray diffraction analysis, infrared spectroscopy, and scanning electron microscopy were taken. The X-ray diffraction pattern of the samples were obtained in the $10^{\circ}{\sim}80^{\circ}2{\theta}$ range with $Cu-K{\alpha}$ radiation using M18HF(Mac Science Co.) with X-ray diffractometer operating at 40 KV and 300 mA. The infra-red spectra of the ground samples in 300 mg KBr pellets 10 mm diameter were obtained in the $4000cm^{-1}\;to\;400cm^{-1}$ range using JASCO 300E spectrophotometer. The scanning electron microscopy was carried out using JSM6400(JEOL Co.) with $500{\sim}2000$ times magnification. The results were as follow 1. The concentration of calcium dissolved from laser irradiated enamel with $50J/cm^2$ was significantly lesser than that of unlased control group (p<0.05) 2. From the result of the X-ray diffraction analysis, $\beta$-TCP, which increases acid solubility, was identified in lased enamel but the diffraction peaks of (002) and (004) became sharp with increasing energy density of laser irradiation. This means that the crystals in lased samples were grown through the c-axis and subsequently, the acid solubility of enamel decreased. 3. The a-axis parameter was slightly increased by laser irradiation, whereas the c-axis parameter was almost constant except for a little decrease at $50J/cm^2$. 4. In the infra-red spectra of lased enamels, phosphate bands ($600{\sim}500cm^{-1}$), B-carbonate bands (870, $1415{\sim}1455cm^{-1}$), and A-carbonate band ($1545cm^{-1}$) were observed. The amounts of phosphate bands and the B-carbonate bands were reduced, on the other hand, the amount of the A-carbonate band was increased by increase the energy density. 5. The SEM experiments reveal that the surface melting and recrystallization were appeared at $30J/cm^2$ and the cracks were observed at $70J/cm^2$. From above results, It may be suggested that the most effective energy density for improving acid resistance of tooth enamel with the irradiation of Nd-YAG laser was $50J/cm^2$. The mechanism of improving acid resistance were reduction of permeability due to surface melting and recrystallization of lased enamel and reduction of acid solubility of enamel due to decrease of carbonate content and growth of crystal.

  • PDF