• Title/Summary/Keyword: edge effect

Search Result 1,506, Processing Time 0.031 seconds

A Study on the Ancient Architecture in view of the Stone Remains (focused on the 3 Kingdom Period and Unificated Shilla Period) (석조유구(石造遺構)를 통한 한국(韓國) 고대건축(古代建築)에 관한 연구(硏究) -삼국시대와 통일신라시대를 중심으로-)

  • Cheon, Deuk-Youm;Park, Ji-Min
    • Journal of architectural history
    • /
    • v.8 no.3 s.20
    • /
    • pp.23-38
    • /
    • 1999
  • The purpose of this study is to analogize the appearance of Korean Ancient Architecture in view of the Stone Remains from 3 Kingdom Period to Unificated Shilla Period. But in these period, there is no building remains but some stupas and fine arts. Especially, there are many architectural appearance and revealing signature in these Historical Stone remains. Architectural elements which are analogized by stone remains what has value as historical materials by preservation of original form from 3 Kingdom Preiod to Unificated Shilla Period are as follows : 1) Platform, the representative characteristic of Korean traditional architecture, was frame structure and accumulate structure. And circular or square footing stood a same shape column on it is put on the platform. 2) In the case of column, there used entasis column and inclined column and circular chamfer technique was applied on the top side of it. Upper side of column, capital and head pentrating tie that small bearing block was put on the center of it was joined. And longitu야nal rest(長舌) supported a cross beam. Capital and small bearing block had no bottom heel, and heel side was curved and straight. Centered bracket structure was often used, and multi bracket structure is not used yet. Inward incline technique was used. 3) Inward opening pair door which had lintel, threshold, doorjamb was usually used, Fixing stone was used for structural safety, and circular handle and lock was used for decoration. Handrail was used on the edge of wooden floor for decorative effect and safety. 4) Square rafter and circular rafter were used in the same period and so did flying rafter. Double eaves and single eave were used in the same period but, single eave was usually used. In this period, square rafter was usually used. This would be studied more by comparing with Japanese wooden architecture. 5) Hipped roof was used and half-hipped roof was not used yet. In front of th hip, there are small sculpture called Jap-Sang(雜像), and windbell was hang on the end of the hip rafter. Concave roof tile, convex roof tile, round eaver tile, decorative tile at end of roof ridge were used. Lotus style was well used on the face of roof tile for decoration. From the results of this study, wooden architecture of Unificated Shilla period was simple compare to Koryo dynasty and Chosun dynasty but, it had some brilliant character. It was hard work that analogized the form of non-existent wood architecture of Ancient Korean period by restricted stone remains. But, in addition to the results of this study and research of old documentations, more study should be go on.

  • PDF

A STUDY ON THE FRACTURE STRENGTH OF ALL-CERAMIC CROWNS (수종 전부도재관의 파절강도에 관한 비교연구)

  • Paek, Seung-Jin;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.4
    • /
    • pp.611-633
    • /
    • 1995
  • The pupose of this study was to compare the fracture strength of five kinds of all-ceramic crowns(Vintage, Dicor Empress-staining, Empress-layering, In-Ceram) luted with glass ionomer cerment and composite resin cement and to evaluate the effect of cements on the fracture stregth of all ceramic crowns. Five groups of twelve uniform sized all-ceramic crown specimens were fabricated. Six specimens of each group were cemented with glass ionomer cement(Fuji G.I. Cement) and the remaining six specimens of each group were etched, silane-treated, and cemented with composite resin cement(Bistite resin cement). The crowns were stored in water$(37^{\circ}C)$ for 1 day prior to loading in an Instron, using a steel ball(diameter 4mm) at a crosshead speed of 0.5mm/min. The crowns were angled $30^{\circ}$, so the steel ball contacted with the crowns 2mm lingual from the mid-incisal edge. The results obtained were summarized as follows ; 1. With G.I. cement, mean fracture load(Kg) Were : Intage : $18.33{\pm}1.47$ ; Empress-staining : $23.92{\pm}6.67$ ; Dicor : $24.0{\pm}5.81$ ; Empress-layering : $26.92{\pm}2.80$ ; In-Ceram : $51.58{\pm}6.87$ ; ANOVA revealed a significant difference existed(p<0.05) between the group A(Vintage, Dicor, Empress-staining, Empress-layering) and group B(In-Ceram). 2. With Resin cement, mean fracture load(Kg) were : Intage : $22.75{\pm}4.97$ ; Dicor : $42.75{\pm}7.07$ ; Empress-staining : $44.08{\pm}7.99$ ; Empresslayering : $50.42{\pm}5.43$ ; In-Ceram : $52.58{\pm}6.51$ ; ANOVA revealed a significatnt difference existed(p<0.05) between the group A(Vintage) and B(Dicor, Empress-staining Empress-alyering, In-Ceram). 3. Resin cement significantly increased the fracture strength of the all-ceramic crowns for Dicor(156%), Empress-staining(185%), Empress-alyering(187%)(p<0.05); but did not increase the fracture strength of Vintage(128%) and In-Ceram(101%)(p>0.05). 4. Majority of the all-ceramic crowns show a wedge fracture extending through proximal surfaces to an apex, usually apical third(with G.I. cement) or middle third(with Resin cement) of the facial surface.

  • PDF

상부 Au 전극 면적 Size에 따른 PbI2 필름의 전기적 특성 평가

  • Myeong, Ju-Yeon;Park, Jeong-Eun;Kim, Dae-Guk;Kim, Gyo-Tae;Jo, Gyu-Seok;O, Gyeong-Min;Nam, Sang-Hui
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.374-374
    • /
    • 2014
  • 의료용 X-ray는 과거 analog 방식과, 연구가 진행 중이며 현재 많이 사용되고 있는 digital 방식으로 나누어진다. 최근, 광도전체와 형광체 기반의 flat panel X-ray detector의 발전에 따른 상용화가 이루어지고 있으며, 많은 발전 가능성이 제기되고 있다. flat panel X-ray detector 검출방식은 direct method (직접 방식)와 indirect method (간접 방식)로 나누어진다. 본 연구는 일반적으로 상용화 되어있는 amorphous seleinum (비정질 셀레늄)의 큰 일함수에 의한 저 해상력이라는 단점을 보완하기 위해, 작은 일함수를 가지는 물질을 사용하여, 영상을 얻을 시에 높은 해상력으로 표현할 수 있도록 하고, 원자번호가 높은 물질을 사용하여 X-ray 흡수율을 높일 수 있도록 기존 direct method에 많이 사용되고 있는 amorphous seleinum 기반 digital X-ray detector가 아닌, 이러한 장점을 충족시킬 수 있는 PbI2 물질 층을 사용하여 시편을 제작 하였다. PbI2를 같은 두께로 올린 후, 물질 층 상부에 Au 전극 면적을 다른 size로 제작한 시편으로 X-ray에 노출 시켰다. 이는 상부 전극 size 차이에 따른 신호 차이를 측정하여 전기적 특성을 평가하기 위한 것이다. 전도성을 띠고 있는 ITO (Indium - Tin - Oxide) glass를 이용하여 screen printing 방법으로 제작하였다. PbI2층을 약 160~180 um두께, $3cm{\times}3cm$ size로 5개 제작하였으며, 상부 전극으로는 Au를 진공 증착 시켰다. 상부 전극 size는 각각 시편 5개에 $0.5cm{\times}0.5cm$, $1cm{\times}1cm$, $1.5cm{\times}1.5cm$, $2cm{\times}2cm$, $2.5cm{\times}2.5cm$로 PbI2 물질 층 중앙에 증착 시켰다. 이러한 설정으로 X-ray 노출 시 관찰할 수 있는 PbI2의 전기적인 특성을 평가할 수 있었다. 관전압을 40 kVp, 60 kVp, 80 kVp, 100 kVp, 120 kVp, 140 kVp로 설정하고, 관전류는 100 mA로 설정하였으며, Dark current, Sensitivity를 측정하였다. Dark current와 Sensitivity를 측정한 뒤, 그 값을 이용하여 SNR (신호 대 잡음 비)값을 구해보았다.실험 결과 단위면적당 signal과 SNR을 분석할 수 있었다. 80 kVp로 기준을 잡고 결과 값을 보면 $0.5cm{\times}0.5cm$ 시편에서 2.92 nC/cm2, $2.5cm{\times}2.5cm$ 시편에서 0.84 nC/cm2로 상부 전극 크기가 작을수록 더 좋은 신호를 측정할 수 있었다. 똑같은 기준에서 SNR을 계산 해 보았을 때, $0.5cm{\times}0.5cm$ 시편에서 6.46, $2.5cm{\times}2.5cm$ 시편에서 1.91로 SNR역시 상부 전극 크기가 작을수록 더 큰 값을 확인할 수 있었다. 이러한 결과는 edge-effect의 영향으로 인해 나온 결과라고 할 수 있다. 이러한 실험 결과, detector 제작 시, 같은 물질을 사용하여 더 높은 효율을 내기 위해서는 큰 size의 상부 전극 보다는 작은 size의 상부 전극을 증착 시키는 것이 전기적 특성을 더욱 효율적으로 평가할 수 있을 것이라고 사료된다.

  • PDF

The riparian vegetation community models according to hydrologic and soil environments - Case of Daecheongho lake reservoirs - (수문 및 토양환경을 고려한 수변식생군락 조성 모델 - 대청호 저수지를 사례로 -)

  • Park, Miok
    • Journal of Wetlands Research
    • /
    • v.19 no.1
    • /
    • pp.144-154
    • /
    • 2017
  • The riparian vegetation is one of corridor type ecosystems, an ecotone and able to improve the ecological soundness by structural and functional link. And they act as habitats, sources and sinks of species, conduits, filters and barriers. This study was carried out to develop the vegetation model for the fluctuation areas of lake reservoirs consider of hydrologic and soil environments according to the vegetation structure of the reference ecosystem. To develop the case study, 2 sites within 10degree slope of the Daecheong Lake were selected. The riparian vegetation models were built by the results of GIS analysis, remote satellite analysis, field survey results, consider of water level, flooded frequency, soil and topographic index, land cover or land use etc. 1) study area varied from FWL to -5m of NFWL, 2) slope 10% below, 3) vegetations flooded below 100days yearly are Salix koreensis, Salix chaenomeloides, Salix gracilistyla, 4)land cover type classified wildlife grassland, abandoned paddy field, cropland according to landuse (or landcover), 5)finally model was constructed as ecological landscape forest. The model designs were suggested by 2 types in Daecheong lake reservoir. The model for the riparian vegetation corridors could be the basic and useful data to improve the ecological and landscape properties.

A study of the photoluminescence of undoped ZnO and Al doped ZnO single crystal films on sapphire substrate grown by RF magnetron sputtering (RF 스퍼터링법으로 사파이어 기판 위에 성장한 ZnO와 ZnO : A1 박막의 질소 및 수소 후열처리에 따른 Photoluminescence 특성)

  • Cho, Jung;Yoon, Ki-Hyun;Jung, Hyung-Jin;Choi, Won-Kook
    • Korean Journal of Materials Research
    • /
    • v.11 no.10
    • /
    • pp.889-894
    • /
    • 2001
  • 2wt% $Al_2O_3-doped$ ZnO (AZO) thin films were deposited on sapphire (0001) single crystal substrate by parellel type rf magnetron sputtering at 55$0^{\circ}C$. The as-grown AZO thin films was polycrystalline and showed only broad deep defect-level photoluminescence (PL). In order to examine the change of PL property, AZO thin films were annealed in $N_2$ (N-AZO) and $H_2$ (H-AZO) at the temperature of $600^{\circ}C$~$1000^{\circ}C$ through rapid thermal annealing. After annealed at $800^{\circ}C$, N-AZO shows near band edge emission (NBE) with very small deep-level emission, and then N-AZO annealed at $900^{\circ}C$ shows only sharp NBE with 219 meV FWHM. In Comparison with N-AZO, H-AZO exhibits very interesting PL features. After $600^{\circ}C$ annealing, deep defect-level emission was quire quenched and NBE around 382 nm (3.2 eV) was observed, which can be explained by the $H_2$passivation effect. At elevated temperature, two interesting peaks corresponding to violet (406 nm, 3.05 eV) and blue (436 nm, 2.84 eV) emission was firstly observed in AZO thin films. Moreover, peculiar PL peak around 694 nm (1.78 eV) is also firstly observed in all the H-AZO thin films and this is believed good evidence of hydrogenation of AZO. Based on defect-level scheme calculated by using the full potential linear muffin-tin orbital (FP-LMTO), the emission 3.2 eV, 3.05 eV, 3.84 eV and 1.78 eV of H-AZO are substantially deginated as exciton emission, transition from conduction band maximum to $V_{ Zn},$ from $Zn_i$, to valence band maximum $(V_{BM})$ and from $V_{o} to V_BM}$, respectively.

  • PDF

A Study on Design for Reliability for the PBA of Warship based on Reliability Physics Analysis (신뢰성 물리학 분석 기반 함정탑재 PBA 신뢰성 설계에 대한 연구)

  • Cha, Jong-Han;Park, Kyoung-Deok;Lee, Ki-Won;Bak, Byeong-Ho;Kim, Hee-Earn;Kwon, Hyeong-Ahn
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.12
    • /
    • pp.535-545
    • /
    • 2019
  • The PBA of ship weapon system should be installed and operated under harsh environmental conditions and so it should be highly reliable to endure the mission profiles during its entire lifetime. In the case of PBA failure during operation, rapid maintenance is highly likely to be difficult due to problems such as supply of parts, which can have a devastating effect on the mission. In order to validate the reliability of PBA, a series of tests are performed with PBA samples, but they require time, testing facilities, samples, expenses and failure analysis if failed. The reliability of PBA is predicted on the basis of specifications such as MIL-HDBK-217F, but this specification does not take into account failure mechanisms for specific design details, environment and usage, interconnects and its characteristics that drive many failures of PBA in the field. Therefore, this study predicts the reliability of PBA using an RPA tool and proposes the RPA methodology as a validation process at the design stage. With RPA, it is now possible to achieve design validation including inherent failure mechanism, identification of weakest link, alternative design options, and test plan development.

THE EFFECTS OF SURFACE CONTAMINATION ON THE SHEAR BOND STRENGTH OF COMPOMER

  • Heo, Jeong-Moo;Lee, Su-Jong;Im, Mi-Kyung
    • Proceedings of the KACD Conference
    • /
    • 2001.11a
    • /
    • pp.577-577
    • /
    • 2001
  • The lastest concepts in bonding are "total etch", in which both enamel and dentin are etched with an acid to remove the smear layers, and "wet dentin" in which the dentin is not blown dry but left moist before application of the bonding primer. Ideally, the application of a bonding agent to tooth structure should be insensitive to minor contamination from oral fluids. Clinically contaminations such as saliva, gingival fluid, blood and handpiece lubricant are often encountered by dentists during preparation of a restoration. The aim of this study was to evaluate the effect of contamination by hem-ostatic agents on shear bond strength of compomer restorations. One hundred and ten extracted human maxillary and mandibular molar teeth were collected. The teeth were cleaned from soft tissue remnant and debris and stored in physiologic solution until they were used. Small flat area on dentin of the buccal surface were wet ground serially with 400, 800 and 1200 abrasive paper on automatic polishing machine. The teeth were randomly divided into 11 groups. Each group was conditioned as follows: Group 1 : Dentin surface was not etched and not contaminated by hemostatic agents. Group2 : Dentin surface was not etched but was contaminated by Astringedent (Ultradent product Inc., Utah, U.S.A.). Group3 : Dentin surface was not etched but was contaminated by Bosmin (Jeil Phann, Korea.). Group4 : Dentin surface was not etched but was contaminated by Epri-dent (Epr Industries, NJ, U.S.A.). Group5: Dentin surface was etched and not contaminated by hemostatic agents. Group 6 : Dentin surface was etched and contaminated by Astringedent. Group7 : Dentin surface was etched and contaminated by Bosmin. Group8 : Dentin surface was etched and contaminated by Epri-dent. Group9 : Dentin surface was contaminated by Astringedent. The contaminated surface was rinsed by water and dried by compressed air. Group10 : Dentin surface was contaminated by Bosmin. The contaminated surface was rinsed by water aud dried by compresfed air. Group 11 : Dentin surface was contaminated by Epri-dent. The contaminated surface was rinsed by water and dried by compresfed air. After surface conditioning, F2000 was applicated on the conditoned dentin surface. The teeth were thermocycled in distilled water at $5^{\circ}C\;and\;55^{\circ}C$ for 1000 cycles. The samples were placed on the binder with the bonded compomer-dentin interface parallel to the lmife-edge shearing rod of the Universal testing machine(Zwick 020, Germany) running at a cross head speed of 1.0mmimin. There were no significant differences in shear bond strength between groups 1 and group 3 and 4, but group 2 showed significant decrease in shear bond strength compared with group 1. There were no significant differences in shear bond strength between group 5 and group 7 and 8, but group 6 showed significant decrease in shear bond strength compared with group 5. There were no significant differences in shear bond strength between group 5 and group 9, 10 and 11.

  • PDF

EFFECT OF RESIN MATRIX ON DEGREE OF CONVERSION AND FRACTURE TOUGHNESS OF DENIAL COMPOSITES (기질레진의 조성에 따른 복합레진의 물리적 성질에 관한 연구)

  • Lee, Yun-Shin;Choi, Kyoung-Kyu;Park, Sang-Jin
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.1
    • /
    • pp.77-86
    • /
    • 2002
  • Current composites are made with dimethacrylate monomers and silane-treated silica microfillers, either alone or with silane treated glass fillers The main reasons for clinical failure of dental composites are secondary caries, wear and fracture. Most of practitioner want to get a composite which is more tougher under occlusal stress, less polymerization contraction, and better handling properties in application clinically. The aim of this study was to investigate the influence of resin matrix with various flows on the physical proper-ties such as fracture toughness and degree of conversion of the experimental resins. It was hypothesized that flexible or tough resin composites can be designed by judicious choice of monomer composition Various flow resin matrices containing Bis-GMA, UDMA, and TEG-DMA were made by altering the pro-portion of the monomers. After the unfilled resins were light-cured for different light intensity, the fracture toughness(K$_{1c}$) was measured according to ASTM standard using the single edge notched geometry, and degree of conversion(DC) was measured by FTIR. And experimental composites were formulated with variations in the proportion of silanated quartz and strontium glass fillers as 60, 75, and 77wt%. Also, the physical properties of composites with various filer contents were evaluated as same manner. All resulting data were compared by ANOVA/Tukeys test at 0.05 level. The results were as follows; 1. The degree of conversion of high flow resin containing less Bis-GMA was higher than that of low flow unfilled resin 2. While the degree of conversion of unfilled resin was increased according to light intensity for polymerization, there was no significant increase with moderate and high light intensity. Also, the fracture toughness was not increased by high light intensity. 3. The fracture toughness was high in the low flow unfilled resin containing higher contents of Bis-GMA. 4. There was a significant increase for fracture toughness and a tendency for degree of conversion to be reduced when the content of fillers was increased. 5. In the experimental composites, the flow of resin matrix did not affected on the fracture toughness, even, which was decreased as increase of viscosity. These results showed that the physical properties of a dental composite could be attributed to the flow of resin matrix with relative content of monomers. Specific combination of resin monomers should be designed to fulfil the needs of specific indication for use.

Research on Re-creational Experiment and Technique of Gold Powder Painting for Goryeo Gold-painted Porcelain (고려시대 금채자기의 채색기법 재현실험 연구)

  • Hwang, Hyun-Sung;Lee, Da-Hae
    • Journal of Conservation Science
    • /
    • v.27 no.4
    • /
    • pp.403-414
    • /
    • 2011
  • This study is re-creational experiment of Goryeo gold-painted decoration based on the research of the gold remaining and gold painting technique on the two pieces of Goryeo gold-painted celadon and the three pieces of Chinese gold-painted porcelain on North Song period which ones have been owned by National Museum of Korea since 2007. For the observation of glue state and color developing ability, four kinds of agglutinative agent and gold powder were mixed over the porcelain sherds, then gradually fired from $100^{\circ}C$ to $1200^{\circ}C$. Visual effect and ideal temperature were measured. Among of them, oil and glue showed the best results in glue state and color developing ability. Through those results, the entire Goryeo engraved celadon were reproduced in modern facilities. Oil and glue were gold-painted over the glaze then it was fired at the ideal temperature 700 to $800^{\circ}C$. For observation the binding condition, the gold-painting cross section was looked by the scanning electron microscope (SEM). As the result, oil and glue did not make much difference in Agglutinative agent, but gold was good, the color developing ability, however, in the case of oil, the edge of gold is curled because of its interfacial tension, and it is not dried well at room temperature so the working property is not as good as the glue. Glue more effective in terms of work efficiency, but color developing ability to fall slightly in this experiment were able to see through.

A Study on the Effect of Upstream Parking to Traffic at the 4-Leg Intersection (교차로 상류부 주차가 교통에 미치는 영향에 관한 연구)

  • Ko, Jin;Oh, Seung Hwoon;Rhee, Jongho
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.2D
    • /
    • pp.121-127
    • /
    • 2012
  • One of the traffic problems has been caused by the illegal parking because of the lack of parking space. Especially, the illegal occupancy of the road near an intersection makes an serious reduction of road capacity. The current illegal parking and stop-prohibited areas have been designated for less than 5 meters from the edge or the corner of the 4-leg intersection. However, in reality, the cars parked at the place over 5 meters have had a significant impact on the intersection traffic. In addition, many variables such as intersection type, size, and service levels should be considered as factors which influence on the traffic condition at the intersection. It was assumed that through and right-turn traffic rate have a significant impact on the 4-leg intersection with the illegal parking or stop near it. This study tried to verify the impact through the simulation implementation with MOE and LOS. It shows a guideline to designate the parking or stop-prohibited area near the 4-leg intersection under various traffic conditions.