• Title/Summary/Keyword: ecological elements

Search Result 412, Processing Time 0.024 seconds

Ecological Linkage Assessment of Urban Park by Using Connection Components in Establishment Green Network (도시녹지네트워크 구축에서 연결요소를 활용한 도시공원의 생태적 연결 가능성 평가)

  • Kim, Mi-Ri;Sung, Hyun-Chan
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.17 no.6
    • /
    • pp.61-72
    • /
    • 2014
  • We implemented ecological linkage assessment, through the connection components of the urban forests, rivers and parks, for the ecological connection of the urban parks which are standing out as the core of the urban green networks, so as to suggest basic data to compare, evaluate and improve urban green networks, as a basic study for the evaluation of the ecological connectabilities between the cities. For the ecological linkage assessment, we analyzed to see if the urban parks of Goyang, Ansan and Yongin, which are the subject cities, are actually ecologically connected with forests and rivers, using distance and roads, which are physical connection elements, in consideration of the mobility of the wild animals, and greening ratios and impervious pavement ratios, which are ecological connectabilities in consideration of the ecological values. The overall result of the ecological linkage assessment the physical connection elements and the ecological connection elements shows that the ecological green network ratio through direct connection states is 36.62% in Goyang, 42.55% in Ansan and 64.00% in Yongin, respectively, giving the ecological connectability ratio of less than half, with the average urban ecological green network ration of 47.72%. The comparison result of the ecological connectabilities between the object cities employing the connection elements indicates that when you set up green networks, you should consider together the physical connection elements, such as the roads, which will lower the ecological connectabilities - rather than do it simply based on areas and distances - while the ecological connection elements with the forests and the streams should be reinforced, so that the ecological connectabilities of the urban parks may be enhanced.

Analysis of Ecological Elements in the Nursery Rhymes, Stories, and Plays of the Guide for Educational Activities and Materials for Kindergarten (『유치원 활동 지도 자료집』에 수록된 동시·동화·동극의 생태적 요소 분석)

  • Shin, Se Ni;Seo, Young Hee;Kim, Eun Ju;Han, Mi Ra;Lim, Boo Yeun;Jo, Hea Soog
    • Korean Journal of Child Studies
    • /
    • v.28 no.3
    • /
    • pp.163-173
    • /
    • 2007
  • This study analyzed ecological elements of 140 nursery rhymes, stories, and plays in the $6^{th}$ edition of the Guide for Educational Activities and Materials for Kindergarten. The results show that 24 works(17.1%) have ecological elements. Content analysis of ecological elements in these works show works that deal with the side effects of environmental development(3 nursery stories), the cult of nature(1 nursery rhyme), recognition of the eco-cycle(2 nursery rhymes, 4 stories, 2 plays), dignity of life and recovery of human nature(12 nursery stories). On the basis of the results, children's literature containing ecological elements were suggested.

  • PDF

Survey of actual status of ecological environment elements of certification schools of environment friendly architecture (친환경건축물인증학교의 생태환경요소에 대한 실태조사)

  • Song, Byung-joon;Cho, Jin-il
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.7 no.1
    • /
    • pp.39-55
    • /
    • 2008
  • The purpose of this study is to suggest improvement of certification standards of environment friendly architecture in ecological environment field by surveying and analyzing actual status of actual certification schools of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As contents of the study, first, certification as an examination on certification system of environment friendly architecture, summary of certification system of environment friendly architecture, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual status of ecological environment elements per school grade, region, and population increase by collecting actual data of certification schools of environment friendly architecture. Third, using analysis data of ecological environment elements, ecological area ratio of certification schools of environment friendly architecture per weighted values of space types was calculated and the results were analyzed as the follows. (1) In case of preliminary certification out of total objects of investigation schools was average 34.06% but in this case of certification, it was reduced to 33.07%. However, it is difficult to make judgment as actual evidence data since ecological area ratio of actual preliminary certification is data based on drawing planes. Therefore, in case of this certification, elementary schools was investigated at average 33.11%, middle schools 34.81%, and high schools 31.28% and middle school showed the highest relatively. (2) Besides, average composition ratio of ecological area ratio was 63.04% in case of this certification regardless of school grade and region and it was analyzed that about 70% of ecological area ratio is composed of the natural based green area including pure natural based green land and 6.89% of ecological learning institute.

  • PDF

A Study on the Actual Condition and Environment-Friendly Architecture Certification System of the School Facilities -Focused on Ecological Environment- (친환경학교시설의 인증제도와 실태에 관한 연구 -생태환경을 중심으로-)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.11 no.1
    • /
    • pp.17-24
    • /
    • 2009
  • The purpose of this study is to clarify the actual condition of real certification schools of environment-friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of this study, firstly, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment-friendly architecture and eco-school pilot model project, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Secondly, actual condition of ecological environment elements per school grade by collecting actual data of certification schools environment-friendly architecture were analyzed. As a result, total 35 environment-friendly school facilities are clarified that the average composition ratio of ecological area ratio is 23.0% in case of this certification regardless of school grade and region.

  • PDF

A Case Study on the Actual Conditions of Ecological Environment of the High School Facilities in Gyeongnam Area (경남지역 고등학교시설의 생태환경 실태에 관한 사례 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.1
    • /
    • pp.57-64
    • /
    • 2010
  • This study is to clarify the actual conditions of high school of environment friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of the study, First, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment friendly architecture and certification high school, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual condition of ecological environment elements per non-certification high school by collecting actual data of certification schools environment friendly architecture were analyzed and the results are as the follows. The average of ecological area ratio was 17.8 percent in case of non-certification school facilities it was analyzed that the natural based green area ratio was 17.5 percent, continuous green axis length ratio was 19.0 percent and roof green garden area ratio was 0 percent.

A Case Study on the Composition Method of Environment-Friendly Architecture of the Educational Facilities -Focused on Ecological Environment Elements- (교육시설의 친환경건축 조성기법에 대한 사례 연구 -생태환경요소를 중심으로-)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.13 no.1
    • /
    • pp.55-62
    • /
    • 2011
  • The purpose of this study is to clarify the actual condition of real certification schools of environment-friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of this study, firstly, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment-friendly architecture and eco-school pilot model project, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Secondly, actual condition of ecological environment elements per school grade by collecting actual data of certification schools environment-friendly architecture were analyzed. The average of ecological area ratio was 24.5 percent in case of this certification regardless of school grade and region and it was analyzed that the natural based green area ratio was 22.9 percent, bio-tope area ratio was 0.60 percent and ecological learning places area ratio was 0.39 percent.

A Study on the Planning Elements for Ecological Restoration of Urban Stream through Present Condition Analysis - focused on the Yeocheon and the Mugeo stream - (현황분석을 통한 도시 소하천의 생태하천 계획요소에 관한 연구 -울산광역시 무거.여천천을 중심으로-)

  • Kim, Seong Cheol;Lee, Cheol Yeong
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.747-757
    • /
    • 2004
  • The objectives of this study were to investigate the physical, chemical, and structural characteristics of the stream, especially Mugeo and Yeochon which are being changed to ecological stream by Ulsan city, and to acquire the considerations such as the planning element and plan criteria of the streams for making ecological stream system. Water quality, water quantity, vegetation, in stream structures and facilities, and land usage of the streams were investigated and the build up capabilities of ecological stream for the two streams were also analyzed. Planning elements for restoration to ecological stream included physical and biological purification methods in water quality, short term water acquire alternatives in water quantity, and vegetation recovery plan and improvement of habitation environment in ecological system, respectively. Planing elements in physical structures and facilities also included recovery of concrete levee and removal and recovery of covered channel.

A Case Study on the Actual Condition and Composition Method of Environment-Friendly Architecture of the School Facilities -Focused on Ecological Environment- (학교시설의 친환경건축 조성기법과 실태에 관한 사례 연구 -생태환경부분을 중심으로-)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.11 no.4
    • /
    • pp.9-16
    • /
    • 2009
  • The purpose of this study is to clarify the actual condition of certification schools of environment-friendly architecture and general school per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment-friendly architecture. As the method of the study, first, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment-friendly architecture and eco-school pilot model project in japan, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Second, actual condition of ecological environment elements per school grade(middle school of environment-friendly architecture and general middle school) by collecting actual data of certification schools environment friendly architecture were analyzed and the results are as the follows. The average of ecological area ratio was 28.3 percent in case of this certification regardless of school grade and region and it was analyzed that the natural based green area ratio was 26.5 percent, bio-tope area ratio was 0.4 percent and ecological learning places area ratio was 0.45 percent.

  • PDF

A Study on the Actual condition and Composition Method of Environment-Friendly Architecture of the Elementary School Facilities -Focused on Ecological Environment- (초등학교시설의 친환경건축 조성기법과 실태 연구 -생태환경을 중심으로-)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.12 no.4
    • /
    • pp.69-76
    • /
    • 2010
  • The purpose of this study is to clarify the actual condition of real certification schools of environment-friendly architecture per ecological environment elements through extracting ecological environment elements which is possible to analyze in quantity certification standards of environment friendly architecture. As the method of this study, firstly, certification as an examination on certification system of environment-friendly architecture, summary of certification system of environment-friendly architecture and eco-school pilot model project, ecological environment elements which is possible for quantitative analysis of ecological environment certification standards were extracted. Secondly, actual condition of ecological environment elements per school grade by collecting actual data of certification schools environment-friendly architecture were analyzed. The average of ecological area ratio was 23.3 percent in case of this certification regardless of school grade and region and it was analyzed that the natural based green area ratio was 20.6 percent, bio-tope area ratio was 0.73 percent and ecological learning places area ratio was 0.43 percent.

The Connection System through Environmental Analysing Factor-Plan Element-Control Element-Valuation Index to Improve the Sustainability in Ecological Housing Estate (생태주거단지의 지속가능성제고를 위한 계획요소-제어요소-평가지표 연계시스템 (에너지 계획분야를 중심으로))

  • Seo, Dong-Koo;Oh, Deog-Seong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.11 no.2
    • /
    • pp.49-58
    • /
    • 2008
  • This study aims to identify the structure and system to make close relationship among planning elements, legal regulation and evaluation index toward sustainable development in the ecological housing estate. Through these close relationships the ecological housing estate could get more sustainability. With this consideration, this study consists of following three parts. First, we review the key issues of sustainability in ecological housing which are focused on the energy-efficient planning. Second, we extract the planning elements, legal regulation and evaluation index using the qualitative system dynamics that is found out all phenomenons from viewpoint of closed loop thinking and circular feedback system. Third, we analyse the correlationship among them in terms of energy efficient planning in the ecological housing estate. Finally, we summarize the findings toward sustainability in ecological housing estate through these analysis.

  • PDF