• 제목/요약/키워드: eco-friendly insulation

검색결과 77건 처리시간 0.037초

친환경 고압배전반 개발을 위한 dry air의 압력별 절연내력특성 분석에 관한 연구 (Analysis on the Dielectric Characteristics of Dry Air According to Pressures for Developing an Eco-friendly High Voltage Switchgear)

  • 남석호;강형구
    • 전기학회논문지
    • /
    • 제60권8호
    • /
    • pp.1560-1565
    • /
    • 2011
  • The environmental pollution caused by green-house gases such as $CO_2$ and $SF_6$ has been becoming the main issue of industrial society. Many developed countries are making efforts to minimize the amount of $CO_2$ emission come from the operation of high voltage electrical apparatuses. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions. Nowadays, the study on the development of dry air insulated switchgear (DAIS) which is known as an eco-friendly electrical apparatus is in progress. A DAIS is advantageous for minimizing the effect of impurities and enhancing the dielectric characteristics over an air insulated switchgear (AIS) by applying constant pressure to an enclosed cubicle. Therefore, a study on the electrical insulation performance of dry air as a gaseous insulation medium is conducted in this paper to substitute a gas insulated switchgear (GIS) for DAIS. As results, it is verified that the AC dielectric characteristics of dry air are similar to those of air and the lightning impulse dielectric characteristics of dry air are superior to those of air at 1bar pressure condition. However, dry air is of inferior dielectric characteristics to $SF_6$ at 4bar pressure condition. Finally, it is suggested that the internal pressure of DAIS should be over 4bar pressure to develop a high voltage switchgear which has similar electrical performance to a conventional GIS. Also, the empirical formulae on calculating the maximum electric field intensity at sparkover of dry air are deduced by experiments according to pressures. It is expected that these results are helpful to design and develop a high voltage electrical apparatus.

방송사 건물의 친환경 설계 적용 요소에 대한 에너지 소비 분석 연구 (The Energy Consumption Analysis for the Eco-friendly Design Application Factors of a Broadcasting Building)

  • 김배영;윤혜경
    • 대한건축학회논문집:계획계
    • /
    • 제34권2호
    • /
    • pp.41-48
    • /
    • 2018
  • This study is expected to provide some basic data on how to apply more economical and efficient eco-friendly factors to reduce the carbon emissions. It has been scrutinized and analyzed the environmental factors of passive eco-friendly elements along with active eco-friendly elements as more efficient factors for energy conservation based on the case of a newly constructed broadcasting building with the green building certification in Sangam-dong DMC area. The first analysis was the energy consumption trends in Korea and the necessity of energy saving. Secondly, it was examined the energy consumption in the current status of the broadcasting building. Thirdly, it was looked into the correlation between the eco-friendly design application factors applied to the broadcasting building and the energy consumption types. As a result of the analysis, the application of fan and feed pump inverter along with ventilation system of waste heat recovery ventilation system were more meaningful in accordance with the economic feasibility of broadcasting buildings rather than economical effect of passive elements such as rooftop garden, reinforcement of building insulation. Also, the application of lighting control had the economical feasibility. Therefore, when it is intended to change the green building certification energy related evaluation items of the similar broadcasting building types, it is necessary to change the direction of adding weight to the more economical active element items in the future.

친환경 섬유소재에 대한 대학생들의 인식도 연구 (University Students' Awareness of Eco-friendly Textile Fiber)

  • 이선영;이승구;김정화;이정순
    • 한국생활과학회지
    • /
    • 제21권4호
    • /
    • pp.781-790
    • /
    • 2012
  • In midst of growing interest and awareness towards sustainability and being "green", there has been increased demand for sustainable clothing. In the purpose of boosting eco-friendly textiles industry, this research was conducted by investigating environmentally-conscious clothing behavior of university students and assessing their views on eco-friendliness of fibers. Thus, their awareness on recycled polyester fiber was evaluated. The research was conducted by surveying 257 university students residing in Daejeon. The data were analyzed with descriptive statistics, factor analysis, and reliability analysis, using SPSS 19.0. The results were as follows. 1) The majority of the subjects answered "Disposing clothing in the clothing recycling container" to reduce environmental impact. 2) Six factors of eco-friendliness of fiber were extracted as reutilization, unfinishedness, economics, environment preservation, natural materials, and slow fashion by using factor analysis. 3) Subjects scored organic cotton as most eco-friendly among various fibers. Recycled polyester fiber was graded less sustainable than natural fiber, but more eco-friendly than artificial one. 4) In assessment of subject's awareness of recycled polyester fiber, they highly valued on resource-reutilization and economics, but less valued on its hygiene, thermal insulation and health-functionality.

서고동저형 경사지 주거 밀집지역의 단열성능 개선 효과분석 (An Analysis of Effects through Improved Insulation Performance for High-Density Residential Area on West High East Low Type)

  • 이성화;윤성환
    • 대한건축학회논문집:구조계
    • /
    • 제34권1호
    • /
    • pp.69-78
    • /
    • 2018
  • The purpose of this study is propose eco-friendly remodeling while protecting the living environment of existing residents and preserving the living in pleasant by considering the characteristic of high density sloped residential area. And then, the optimum insulation condition is analyzed based on the energy efficiency, economic analysis and environmental effect. It will be possible as the basic information for remodeling of each housing in sloped area. The energy demanding, cost and the carbon emission reduction is analyzed with the residential area in Seo-gu, Busan by eco-remodelling.

25.8kV 고체절연스위치기어 개발 (Development of 25.8kV class solid insulated switchgear)

  • 이종혁;마지훈;유련;이재걸;원성연;이석원;김영근;길경석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.226-228
    • /
    • 2008
  • In recent years, the companies of electric power equipment for MV and HV classes trend to develop the eco-friendly insulated(solid, eco-gas, air etc.) switchgear which replaces existent SF6 gas insulated switchgear due to environmental problems such as global warming and so on. This paper makes reference to the newly developed Solid Insulated Switchgear (SIS) which uses the eco-friendly material such as epoxy for insulation. The insulation of the solid insulated switchgear (SIS) is composed of an epoxy, vacuum and air. The solid insulated switchgear (SIS) is a slate of the art product. The advantages of SIS are advanced reliability, economical efficiency, safety, maintenance free, reduction of installation area and the protection of environment. The solid insulated switchgear (SIS) is FE Analyzed such as electromagnetic, mechanical, thermal and fluid in order to find the optimal design. Thens SIS has been verified by international standard test. (IEC 62271 - 100 and so on.) As a result of this, the solid insulated switchgear (SIS) has been estimated as an alternative for eco-friendly MV class switchgear.

  • PDF

초진공 단열재의 열 물성 특성에 관한 연구 (Thermal Property Characteristics of Super insulation Vacuum Panel)

  • 전현석;최현중;최경석;강재식;이승언
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.599-602
    • /
    • 2009
  • Recently, some major environmental problems are the increase of fossil fuel price and $CO_2$ emission. To solve these problems, it is imperative to develop eco-friendly techniques and to reduce energy consumption in apartment complexes. Therefore, an effective system for insulation needs to be developed to reduce energy consumption. This study compares thermal characteristics between general insulation and super insulation Vacuum Panel, which is thinner and has more insulation efficiency.

  • PDF

복합절연물내 기체의 압력 및 고체의 두께변화가 AC 절연파괴에 미치는 영향 분석 (AC Breakdown Analysis of Composite-Insulation by the Thickness of epoxy and the Variation of Pressure)

  • 정해은;김병철;윤재훈;강성화;임기조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.194-195
    • /
    • 2007
  • $SF_6$ gas used widely as insulating component in electric power industry has excellent in insulation and arc extinguishing performance in gas-insulated switchgear. However, the concern about eco-friendly alternative gas is currently rising because $SF_6$ gas is one of the main greenhouse gases. In this paper, dry-air and composite-insulation (dry-air+epoxy) as the alternative technology for $SF_6$ gas insulation is studied. Under the gas pressure ranged from 0.1 to 0.6MPa, the breakdown voltage of dry-air were measured in AC electric field. The data of composite-insulation were acquired by changing the thickness of epoxy used in each composite-insulation under the same condition.

  • PDF

친환경 고전압 전력기기 개발을 위한 GN2의 절연특성 분석 (Analysis on the Dielectric Characteristics of Gaseous Nitrogen for Developing Eco-friendly High Voltage Apparatuses)

  • 방승민;이온유;김준일;강종오;이홍석;고태국;강형구
    • 전기학회논문지P
    • /
    • 제63권4호
    • /
    • pp.356-360
    • /
    • 2014
  • The environmental pollution caused by green-house gases such as $SF_2$ has been becoming the main issue of industrial society. As a part of these efforts, 180 countries signed the Kyoto Protocol in 1997 to cut back on their green-house gas emissions [1]. Therefore, a study on the dielectric characteristics of the $GN_2$ is important for designing a eco-friendly high voltage apparatuses. In this paper, to develop an electrically reliable, stable, and eco-friendly high voltage apparatus, the breakdown voltage and partial discharge inception voltage characteristics in $GN_2$ considering utilization factors are studied for the establishment of insulation design criteria of an high voltage apparatus. Dielectric experiments are performed by using several kinds of sphere-plane electrode systems made of stainless steel. Also, the dielectric characteristics of the $GN_2$ are analyzed by using a Finite Elements Method (FEM) according to various field utilization factors. The results are expected to be applicable to designing the high voltage apparatuses using $GN_2$ as an insulation gas.

불평등전계에서의 건조공기/에폭시 복합절연물의 에폭시 두께에 따른 AC 파괴전압 분석 (Analysis of AC Breakdown Voltage accoding to epoxy thickness of Composite Insulation for Dry-Air/Epoxy under non-uniform electric field)

  • 허준;이승수;임기조;정해은;강성화
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.113-114
    • /
    • 2008
  • The purpose of this paper is to analyze AC Breakdown of solid/air composite insulation depending on the thickness and the pressure of dry air for eco-friendly insulation. SF6 gas has been widely used in electric equipment as gas insulation because of high dielectric strength and arc extinguishing performance. However, because SF6 gas is one of the green house effect gases, alternative insulation such as SF6 mixture, extremely low temperature gas, vacuum, liquid and solid insulating are being investigated.

  • PDF

Development of eco-friendly and lightweight insulation panels for offshore plant

  • Jung, Jae-Deok;Hong, Suk-Yoon;Song, Jee-Hun;Kwon, Hyun-Wung;Joo, Won-Ho;Kim, Sung-Hoon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제8권6호
    • /
    • pp.554-562
    • /
    • 2016
  • Recently, regulations pertaining to the noise and vibration environment of offshore plants have been strengthened. For example, the NORSOK standards have been applied, which are very strict regulations that are comparable to those applied to passenger ships. Furthermore, the use of porous materials, such as those used in most of the current insulating panels, has been forbidden. Therefore, honeycomb-backed Micro-Perforated Plates (MPPs) are now regarded as next-generation absorber materials. This paper reports the results of parametric studies that were performed using numerical methods to determine the effect of the thickness on the performance of a honeycomb panel and the effect of the perforation ratio on the MPP performance. The numerical results were verified through experiments. Finally, we propose a combined honeycomb/MPP panel where the MPP is placed between upper and lower honeycomb panels and one end surface is also replaced with an MPP.