• 제목/요약/키워드: eccentric mass

검색결과 86건 처리시간 0.029초

첨단 질량을 갖는 선형 원뿔대의 자유진동 (On the Free Vibration of Immersed Linearly Tapered Beam with a Tip Mass)

  • Shin, Young-Jae;Sung, Kyung-Yun;Yun, Jong-Hak
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 추계학술대회논문초록집
    • /
    • pp.402.1-402
    • /
    • 2002
  • A linearly tapered beam immersed partially in other material is considered and is modelled as a linearly tapered Bernoulli-Euler beam fixed at the bottom with a concentrated mass at the top. Its governing equations is derived and its free vibration analysis is performed for various boundary conditions. And the rotatory inertia of the eccentric lumped tip mass is considered. (omitted)

  • PDF

비틀림 강성을 가지는 동조질량감쇠기를 이용한 편심건물의 제어 (Control of the Eccentric Building Using a TMD with Torsional Rigidity)

  • 박용구;김현수;이동근
    • 한국공간구조학회논문집
    • /
    • 제12권2호
    • /
    • pp.65-72
    • /
    • 2012
  • 본 연구에서는 비틀림 거동을 일으키는 편심구조물의 효율적인 제어를 위한 비틀림 강성을 가지는 동조질량감쇠기의 제어성능을 검토하고자 한다. 이를 위하여 지진하중을 받는 편심구조물에 동조질량감쇠기의 설치위치와 비틀림강성에 따른 제어성능을 평가한다. 반복되는 시간이력해석시 소요되는 해석시간을 줄이기 위하여 등가해석 모델을 사용하였고 비비례감쇠시스템인 동조질량감쇠가 설치된 구조물의 해석을 효율적으로 수행할 수 있었다. 본 연구를 통하여 일반적인 동조질량감쇠기에서 무시되어온 동조질량감쇠기의 비틀림 속성이 비틀림 거동이 발생하는 편심구조물에서는 효과적일 수 있음을 검증하였다. 그리고 편심구조물의 경우에는 동조질량감쇠기의 최적 설치 위치가 구조물 평면의 중심이 아닐 수 있음을 확인하였다.

철근콘크리트조 4층 골조건물의 강제진동실험 (Forced Vibration Testing of a Four-Story Reinforced Concrete Frame Building)

  • 유은종
    • 한국지진공학회논문집
    • /
    • 제11권2호
    • /
    • pp.27-38
    • /
    • 2007
  • 노스리지 지진에 의해 손상을 받은4층 철근콘크리트조 골조건물을 대상으로 선형가진기 및 대용량의 편심가진기를 이용한 강제진동실험과 상시미진동 측정을 실시하였다. 미진동 가속도데이터 및 선형가진기에 의한 백색잡음 실험시의 가속도데이터로부터 구조물식별을 수행하여 7차모드까지의 고유진동수 및 모드감쇠비를 얻었다. 두대의 대용량 편심가진기를 사용하여 얻은 큰 진폭의 조화 진동하에서는 가속도데이터를 사용하여 각 방향 1차모드를 식별하였으며 변위계와 변형게이지를 이용하여 층간변위각, 기둥과 슬래브와 같은 구조부재의 곡률분포를 측정하였다. 각 경우 고유진동수는 진동의 크기가 클수록 낮아졌다. 즉, 편심가진기가력시 고유진동수는 상시미진동시에 비해 $70{\sim}75%$, 선형가진시가력시에 비해 $92{\sim}93%$ 정도로 낮게 나타났다. 이러한 진동수의 감소폭은 지진에 의해 큰 손상을 받았던 건물의 남북방향에서 크게 나타났다.

Ratio of Torsion (ROT): An index for assessing the global induced torsion in plan irregular buildings

  • Stathi, Chrysanthi G.;Bakas, Nikolaos P.;Lagaros, Nikos D.;Papadrakakis, Manolis
    • Earthquakes and Structures
    • /
    • 제9권1호
    • /
    • pp.145-171
    • /
    • 2015
  • Due to earthquakes, many structures suffered extensive damages that were attributed to the torsional effect caused by mass, stiffness or strength eccentricity. Due to this type of asymmetry torsional moments are generated that are imposed by means of additional shear forces developed at the vertical resisting structural elements of the buildings. Although the torsional effect on the response of reinforced concrete buildings was the subject of extensive research over the last decades, a quantitative index measuring the amplification of the shear forces developed at the vertical resisting elements due to lateral-torsional coupling valid for both elastic and elastoplastic response states is still missing. In this study a reliable index capable of assessing the torsional effect is proposed. The performance of the proposed index is evaluated and its correlation with structural response quantities like displacements, interstorey drift, base torque, shear forces and upper diaphragm's rotation is presented. Torsionally stiff, mass eccentric single-story and multistory structures, subjected to bidirectional excitation, are considered and nonlinear dynamic analyses are performed using natural records selected for three hazard levels. It was found that the proposed index provides reliable prediction of the magnitude of torsional effect for all test examples considered.

Exact vibration of Timoshenko beam combined with multiple mass spring sub-systems

  • El-Sayed, Tamer A.;Farghaly, Said H.
    • Structural Engineering and Mechanics
    • /
    • 제57권6호
    • /
    • pp.989-1014
    • /
    • 2016
  • This paper deals with the analysis of the natural frequencies, mode shapes of an axially loaded beam system carrying ends consisting of non-concentrated tip masses and three spring-two mass sub-systems. The influence of system design and sub-system parameters on the combined system characteristics is the major part of this investigation. The effect of material properties, rotary inertia and shear deformation of the beam system is included. The end masses are elastically supported against rotation and translation at an offset point from the point of attachment. Sub-systems are attached to center of gravity eccentric points out of the beam span. The boundary conditions of the ordinary differential equation governing the lateral deflections and slope due to bending of the beam system including developed shear force frequency dependent terms, due to the sub.system suspension, have been formulated. Exact formulae for the modal frequencies and the modal shapes have been derived. Based on these formulae, detailed parametric studies are carried out. The geometrical and mechanical parameters of the system under study have been presented in non-dimensional analysis. The applied mathematical model is presented to cover wide range of mechanical, naval and structural engineering applications.

분동교환기를 이용한 고체밀도기준물의 질량측정 (Mass measuremeant of soilid density standard using weight exchanger)

  • 이용재;장경호;오재윤;정상덕
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1659-1662
    • /
    • 2003
  • The mass measurement of solid density standards using weight exchanger is described. KRISS(Korea Research Institute od Standards and Science) has several solid density standards. Their mass have been measured manually only using a mass comparator(Mettler, 1kg - 0.01mg). However, the uncertaity of the manual mass measurement is up to 300 microgarm much more than 32 microgram of advanced NMIS(National Metrology Institutes) for 1 kg silicon sphere which is primary density standards due to an eccentric error and buoyancy correction error. The new system with a weight exchanger is designed and built to improve the measurement accuracy. It comprises a weight exchager, a mass comparator, air density instruments, and application program for automatic measurement. It is evaluated by measuring several elements in an air tight chamber to verify the performance of it.

  • PDF

The Characteristics of Electrocardiography Findings in Left Ventricular Remodeling Patterns of Hypertensive Patients

  • Choi, Sun Young
    • 대한의생명과학회지
    • /
    • 제21권4호
    • /
    • pp.208-217
    • /
    • 2015
  • The exact diagnosis of left ventricular hypertrophy (LVH) is very important in the treatment of hypertension. The purpose of our study is to determine the relationship between left ventricular remodeling patterns and electrocardiography (ECG) findings in hypertensive patients. We divided 137 patients into four groups according to left ventricular mass index (LVMI) and the relative wall thickness: normal, concentric remodeling, concentric hypertrophy, eccentric hypertrophy. LVH on the ECG was defined by three ECG criteria: Sokolow-Lyon voltage criteria, Cornell voltage criteria and Romhilt-Estes point score. LVH on the echocardiography was defined by LVMI. The prevalence of ECG LVH was increased in concentric hypertrophy and eccentric hypertrophy group. The QRS voltages by Sokolow-Lyon voltage criteria (r = 0.494, P = 0.002) and Cornell voltage criteria (r = 0.628, P < 0.001), and Romhilt-Estes point score (r = 0.689, P < 0.001) were positively correlated with LVMI. Also, the QRS voltages and point scores were significantly increased in the concentric hypertrophy and eccentric hypertrophy group with increased LVMI. The QRS voltage and Romhilt-Estes point scores were positively correlated with LVMI. The QRS voltages and Romhilt-Estes point scores were also increased in the left ventricular remodeling groups with increased LVMI.

Seismic analysis of frame-strap footing-nonlinear soil system to study column forces

  • Garg, Vivek;Hora, Manjeet S.
    • Structural Engineering and Mechanics
    • /
    • 제46권5호
    • /
    • pp.645-672
    • /
    • 2013
  • The differential settlements and rotations among footings cannot be avoided when the frame-footing-soil system is subjected to seismic/dynamic loading. Also, there may be a situation where column(s) of a building are located near adjoining property line causes eccentric loading on foundation system. The strap beams may be provided to control the rotation of the footings within permissible limits caused due to such eccentric loading. In the present work, the seismic interaction analysis of a three-bay three-storey, space frame-footing-strap beam-soil system is carried out to investigate the interaction behavior using finite element software (ANSYS). The RCC structure and their foundation are assumed to behave in linear manner while the supporting soil mass is treated as nonlinear elastic material. The seismic interaction analyses of space frame-isolated footing-soil and space frame-strap footing-soil systems are carried out to evaluate the forces in the columns. The results indicate that the bending moments of very high magnitude are induced at column bases resting on eccentric footing of frame-isolated footing-soil interaction system. However, use of strap beams controls these moments quite effectively. The soil-structure interaction effect causes significant redistribution of column forces compared to non-interaction analysis. The axial forces in the columns are distributed more uniformly when the interaction effects are considered in the analysis.

상단 집중질량을 갖는 근입 말뚝의 진동 특성 (Vibration Characteristics of Embedded Piles Carrying a Tip Mass)

  • 최동찬;변요셉;오상진;천병식
    • 한국소음진동공학회논문집
    • /
    • 제20권4호
    • /
    • pp.405-413
    • /
    • 2010
  • The vibration characteristics of fully and partially embedded piles with flexibly supported end carrying an eccentric tip mass are investigated. The pile model is based on the Bernoulli-Euler theory and the soil is idealized as a Winkler model for mathematical simplicity. The governing differential equations for the free vibrations of such members are solved numerically using the corresponding boundary conditions. The lowest three natural frequencies and corresponding mode shapes are calculated over a wide range of non-dimensional system parameters: the rotational spring parameter, the relative stiffness, the embedded ratio, the mass ratio, the dimensionless mass moment of inertia, and the tip mass eccentricity.