• Title/Summary/Keyword: eccentric

Search Result 903, Processing Time 0.027 seconds

An Experimental study on the behavior of gap N-joints in Cold-formed Square Hollow Sections with connection plate for a tension member (인장용 연결 플레이트를 갖는 각형강관 갭 N형 접합부의 거동에 관한 실험적 연구)

  • Park, Keum Sung;Bae, Kyu Woong;Moon, Tae Sup
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.6 s.73
    • /
    • pp.769-780
    • /
    • 2004
  • This paper's objective is to evaluate the experimental behavior of gap N-joints made of cold-formed, square, hollow steel sections, with a connection plate as a tension member. The principal parameters for testing included the ratio of chord width to thickness, the ratio of brace width to chord width, eccentric ratio, the shape of the compression member, the branch angle, and the stiffening plate of the chord flange. The strength and failure mode were examined through the test for the gap N-joint, consisting of several parameters. Based on the results of the test, the gap N-joints were determined according to the capacity preceding the displacement of the tension, regardless of the width ratio, and the split failure mode-connected surface for a chord in joints. The strength of the gap N-joints increased proportionally as the $2\gamma$(B/T) ratio decreased, and as the width ratio(${\beta}$) of branch to chord increased. Particularly, $2\gamma$(B/T) decreased as the capacity of gap N-joint increased. The results of the test were summarized for the capacity, initial stiffness, ductility, and change of the failure mode of each gap N-joint.

Verification of 2-Parameters Site Classification System and Site Coefficients (II) - Earthquake Records in Korea (2-매개변수 지반분류 방법 및 지반 증폭계수의 검증 (II) - 국내 실지진 기록을 통한 검증)

  • Lee, Sei-Hyun;Park, Dong-Hee;Ha, Jeong-Gon;Kim, Dong-Soo
    • Journal of the Korean Geotechnical Society
    • /
    • v.28 no.3
    • /
    • pp.35-43
    • /
    • 2012
  • Following the companion paper (I. Comparisons with Well-known Seismic Code and Site Response Characteristics), several acceleration data recorded during recent earthquake events in Korea were analyzed to verify the suitability of the proposed two-parameters site classification system and the corresponding site coefficients. For all of rock-soil site pairs less than 30 km distant, response spectrums and corresponding site coefficients, $F_a$ and $F_v$, were determined. Unfortunately, some of data have an eccentric error, where the spectral acceleration of rock site is more amplified than that of soil site. The $F_a$ and $F_v$ for all of pairs except the pairs of error were compared with those in the current code and the proposed system. The $F_a$ and $F_v$ from the recorded motions show definitely different trend from that of the current code. In addition, the site coefficients from recorded motions at four 765 kV substation sites, which are several hundred meters distant, have a remarkably similar trend and absolute values to those in proposed two-parameters site classification system. Based on earthquake motions recorded in domestic areas including data from the four 765 kV substation sites, the two-parameters site classification and site coefficients are superior to the results obtained from the current Korean seismic code.

Connection Resistance of Mechanical Joint using Connection plate for Improvement of Connectivity between PHC piles (PHC파일간 연결 시공성 개선 이음판형 기계적 연결부의 연결저항)

  • Ahn, Jin-Hee;Moon, Hong-duk;Ha, Min-Gyun;Cho, Kwang-Il
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.25-32
    • /
    • 2019
  • Welded joints and mechanical joints using bolt connection have been used as a pile-to-pile connecting method for PHC piles. These PHC pile joint methods may have difficulty in securing connecting quality and connecting performance in PHC pile joining process. Therefore, this study proposes a non-welded connection plate type mechanical PHC pile joint to improve the disadvantages of existing PHC pile connection methods and to secure the connection performance of PHC pile joint. Its connection performance was evaluated from nonlinear FE analysis and loading tests for actual PHC piles with suggested pile joints. From nonlinear FE analysis for the proposed PHC pile joint, it was evaluated to have sufficient connection performance under flexural, compressive, tensile, shear, and eccentric compressive load condition. PHC piles connected by the suggested connection plate type mechanical PHC pile joint show that they show stable linear behaviors for the crack moment and the flexural moment level of the PHC pile. Therefore, the proposed a non-welded connection plate type mechanical PHC pile joint can secure sufficient connection performance in PHC pile.

Recurrent Extraventricular Neurocytoma with Malignant Glial Differentiation - Case Report - (악성신경교 분화를 보이는 재발성 뇌실외 신경세포종 - 증례보고-)

  • Chang, In-Bok;Park, Se-Hyuck;Hwang, Hyung-Sik;Kim, Duck-Hwan;Nam, Eun Sook;Cho, Byung-Moon;Shin, Dong-Ik;Oh, Sae-Moon
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.4
    • /
    • pp.522-527
    • /
    • 2001
  • We present a case of recurrent extraventricular neurocytoma with malignant glial differentiation in left temporoparietal area. A 37-year-old man with presentation of generalized seizure had undergone biopsy of brain tumor in left parietal area in 1987, which revealed extraventricular neurocytoma and radiotherapy was followed. Postoperative course was uneventful until eleven years after biopsy, when he became gradually aphasic and right hemiplegic. Brain CT and MRI revealed enlargement of tumor with peritumoral edema and calcifications. He underwent subtotal tumor removal in 1998. Microscopic examination of second biopsy specimen revealed presence of large areas composed of anaplastic glial cells with frequent mitosis, nuclear pleomorphism, large eosinophilic cytoplasm and eccentric nuclei, resembling gemistocytes, which were strongly immunoreactive to glial fibrillary acidic protein(GFAP) but not to synaptophysin(SNP). Also focal areas of neuronal cells were found, which were immunoreactive to SNP but not to GFAP. These histologic findings imply that this recurred tumor was a high grade, mixed tumor with divergent differentiation of neuronal and astrocyte lineage. We report a rare case of extraventricular cerebral neurocytoma with malignant glial differentiation with review of the literature.

  • PDF

A Shape Control of Welded Joints to Improve Fatigue Strength (피로강도 향상을 위한 용접이음부의 형상제어에 관한 연구)

  • Kang, Chang Ib;Kook, Seung Kyu;Lee, Dong Uk
    • Journal of Korean Society of Steel Construction
    • /
    • v.16 no.4 s.71
    • /
    • pp.479-492
    • /
    • 2004
  • When U-ribs of steel deck plates are connected at the field, overhead welding should be done with backing strips. Misalignments may occur and lead to eccentric moments as well as high stress concentrations at welded joints. In this study, stress analyses and fatigue tests were carried out. Stress analyses for U-ribs' welded joints with backing strips were performed with different misalignments, root shapes, root gaps, and backing strip sizes. From the stress analyses, the stress concentration factors increased with increasing misalignments and root gaps. With the fixed misalignments and root gaps, the stress concentration factors obtained in the case of the semi-circle root shape were lower than those in the case of the right-angle root shape. It was verified that backing strip sizes have little influence on stress concentration factors. The fatigue tests for U-ribs' welded joints with backing strips indicated that increased misalignments shorten fatigue life drastically and cracks usually initiate at the root of the base metal and are propagated to the weld bead surface. Based on the results of the stress analyses, root-shape control methods were developed to mitigate stress concentration by changing welding condition control, radius curvature, and flank angle.

A Study on Repair/ Retrofit for Deteriorations of Steel Bridge -Behavior Characteristics of Welded Joint Part of Flange and Repair/Retrofit of Fatigue Crack in Railway Steel Bridge- (강철도교 열화현상에 관한 보수/보강 연구 -강철도교의 플랜지 용접이음부의 거동 특성 및 피로균열 보수보강-)

  • Kyung, Kab Soo;Lee, Sung Jin;Park, Jin Eun;Cha, Cheol Jun
    • Journal of Korean Society of Steel Construction
    • /
    • v.24 no.6
    • /
    • pp.613-625
    • /
    • 2012
  • Since railway bridge frequently have a chance of passing train load close to design load, it is necessary to reflect sufficiently fatigue property in early design phase for many structural details. Nevertheless fatigue cracks are reported partly in deck plate girder of railway steel bridge because of the weight and arrangement of axial load acting on railway bridge, the application of improper structural details for fatigue problem etc.. One of main cause for fatigue crack at the welded part of upper flange and web is caused by the eccentricity action of train load due to the difference of center to center spacing between the main girder supporting sleeper and the rail acting train load. For the existing deck plate girder of railway steel bridge, in this study, field survey, field measurement and a series of structural analysis were performed. In addition, the characteristics of structural behavior, the causes and repair/ retrofit of fatigue crack were examined in the target bridge.

A Study of the Chewing Patterns in Patients with Temporomandibular Disorders by Electrognathography (Electrognathography를 이용한 측두하악장애환자의 저작양태에 관한 연구)

  • Moon-Gyu Kim;Kyung-Soo Han
    • Journal of Oral Medicine and Pain
    • /
    • v.20 no.2
    • /
    • pp.291-306
    • /
    • 1995
  • Mandibular movement is composed of border movement and functional movement. Border movement such as maximal mouth opening, hinge opening ad lateral eccentric movement has good reproducibility, but functional movement such as chewing, swallowing and speech has also reproducibility. Especially for chewing movement, individual reproducibility has been confirmed by many studies. Study of chewing pattern is still in controversy. In new approach for raising the diagnostic value, numeric parameters and morphologic characteristics could be used for evaluation of chewing pattern. This study was performed to investigate the differences between chewing pattern in controls and in patients with temporomandibular disorders. Sixty-three patients with temporomandibular disorders participated in this study, and they were divided into unilaterally affected subjects or bilaterally affected subjects. Then unilaterally affected subjects were classified into closed lock group, disk displacement with reduction group, and degenerative joint disease group. For recording of chewing pattern, subjects were asked to chew one piece of presoftened chewing gum on both sides, and the chewing movement was recorded with the Electrognatho- Graphy(Bio-Research Associates Inc., U.S.A.). Tooth contact pattern for occlusal stability (Total left-right statistics )was also recorded with T-Scan(Tekscan Co., U.S.A.). The dta related to chewing pattern and total left-right statistics were statistically analyzed by SAS/stat program. The obtained results were as follows : 1. In patient group, mean value of A-P distance and the ratio of A-P distance to vertical distance were larger than control group, but the value of lateral distance in affected side and the closing velocity in unaffected side were smaller than that of control group, respectively. 2. In case of unilateral affected patients, chewing pattern of other side had tendency to restricted movement and slow velocity in closed lock group or degenerative joint disease group than control group or disk displacement with reduction group. 3. In bilateral degenerative joint disease patients, contralateral side had tendency to large range of motion and slow chewing velocity than preferred chewing side. 4. The patients with restricted mouth opening below than 35mm had higher value of total left-right statistics than patient group mouth opening above 35mm. Also closed lock group had higher total left-right statistics than disk displacement with reduction group, degenerative joint disease group and control group. 5. There was some difference in morphologic characteristics of chewing pattern between in control group and in affected side of unilateral patient group, but no difference between control group and unaffected side of unilateral patient group. 6. There were positive correlations between vertical distance and A-P distance, between vertical distance and chewing velocity, between A-P distance and chewing velocity, and between opening velocity and closing velocity in unilateral affected patients.

  • PDF

A Development of Stem Analysis Program and its Comparison with other Method for Increment Calculation (수간석해(樹幹析解) 전산(電算)프로그램 개발(開發) 및 생장량(生長量) 계산방법(計算方法)의 비교(比較)에 관(關)한 연구(硏究))

  • Byun, Woo Hyuk;Lee, Woo Kyun;Yun, Kwang Bae
    • Journal of Korean Society of Forest Science
    • /
    • v.79 no.1
    • /
    • pp.1-15
    • /
    • 1990
  • In this study the stem analysis program, which can be operated with personal computer was developed to reduce time and cost of calculation, and to increase accuracy of analysis. The stem analysis method used in this program was compared with other methods. The results obtained were as follows : The value, 1/100mm measured from the latest annual ring measurement machine (Jahrringme${\beta}$geraete Johan Type II) was automatically inputed to the computer and saved into given file name. Turbo Pascal program was written to do this. The measured data was analyzed by stem analysis calculation program written by Fortran-77. Volume and height increments were approximated by spline function, and diameter of the stem disk was calculated by quadratic mean method. The increment values calculated by the programs were printed annually and in every five-year. Stem analysis diagram and several increment graphs were also easily printed. The result compared between those analysis methods showed that quadratic mean could reduce the error caused from eccentric pith. When the stem taper curve method, approximated by spline function, was used in the calculation of tree height and volume, increments would be more exactly calculated.

  • PDF

Strength Parameters and Shear Behaviors of North-Cheju Basalt Rubble Using Large-scale Triaxial Test (대형삼축압축시험을 이용한 북제주현무암 사석재의 강도정수 및 전단거동)

  • 정철민;김종수;채영수
    • Journal of the Korean Geotechnical Society
    • /
    • v.18 no.2
    • /
    • pp.147-160
    • /
    • 2002
  • According to the Korean Design Code for port and harbor facilities, bearing capacity of rubble mound under eccentric and inclined load is calculated by the simplified Bishop method, and strength parameters are recommended to be c=0.2kg/$cm^2$ and \phi=35^P\circ}$ fur standard rubble if the compressive strength of parent rock is greater than 300kg/$cm^2$, according to research results by Junichi Mizukami(1991). But this facts have never been verified in Korea because there was no large-scale triaxial test apparatus until 2000 in Korea. For the first time in Korea, the large-scale triaxial test(sample diameter 30cm ; height 60cm) on the rubble originated from porous basalt rock in North-Cheju was accomplished. Then strength parameters for basalt rubble produced in North-Cheju are recommended to be c:0.3kg/$cm^2\; and \phi=36^{\circ}$ if the compressive strength of parent rock is greater than 400kg/$cm^2$. And the shear behavior characteristics of rubble, represented as particle breakage and dilatancy, are investigated.

Lateral Behavior of Group Pile in Sand (사질토 지반에서 군말뚝의 수평거동에 관한 연구)

  • 김영수;김병탁
    • Journal of the Korean Geotechnical Society
    • /
    • v.16 no.1
    • /
    • pp.117-129
    • /
    • 2000
  • This paper discusses the lateral behavior of group pile in homogeneous and non- homogeneous (two layered) soil. In the group pile, the model tests were to investigate the effects on spacing-to-diameter ratio of pile, pile array, ratio of pile spacing, constraint condition of pile tip, eccentric load and ground condition. The group efficiency and lateral deflection induced in active piles were found to be highly dependent on the spacing-to-diameter ratio of pile, number of pile. Lateral bearing capacities in the group piles of fixed tip, in the case of 6D spacing and $3\times3$ array, were 40-100% higher than those in the group pile of free tip. Based on the results obtained, a spacing-to-diameter of 6.0 seems to be large enough to eliminate the group effect for the case of relative density of 61.8% and 32.8%, and then each pile in such a case behaves essentially the same as a single pile. However, in the case of dense sand, it can be estimated that a spacing-to-diameter of 8.0 seems to be large enough to eliminate the group effect. In this study the group efficiency is illustrated in experimental function with spacing-to-diameter, S/D, relative density and number of pile. The distribution of shear force in lead row piles, in the case of 3$\times$3 array group pile, was 41.6-52.4% for 3D spacing and 34-40% for 6D spacing, respectively. The shadowing effect for the parallel direction of lateral loading appears to be more significant than the one for the perpendicular direction of lateral loading.

  • PDF