• Title/Summary/Keyword: earthquake-resistance design

검색결과 176건 처리시간 0.034초

실물 철근콘크리트 교각의 유사동적 실험에 의한 내진성능 평가 (Pseudo-Dynamic Test for Seismic Performance Evaluation of RC Bridge Piers)

  • 박창규;박진영;정영수;조대연
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2002년도 춘계 학술발표회 논문집
    • /
    • pp.250-257
    • /
    • 2002
  • Pseudo dynamic test is an on-line computer control method to achieve the realism of shaking table test with the economy and versatility of the conventional quasi-static approach Pseudo dynamic tests of six full-size RC bridge piers have been carried out to investigate their seismic performance. For the purpose of precise evaluation, the experimental investigation was conducted to study the seismic performance of the real size specimen, which is constructed for highway bridge piers in Korean peninsula. Since it is believed that Korea belongs to the moderate seismicity region, five test specimens were designed in accordance with limited ductility design concept. Another one test specimen was nonseismically designed according to a conventional code. Important test parameters were transverse reinforcement and lap splicing. Lap splicing was frequently used in the plastic hinge region of many bridge columns. Furthermore, the seismic design code is not present about lap splice in Korean Roadway Bridge Design Code. The results show that specimens designed according to the limited ductility design concept exhibit higher seismic resistance. Specimens with longitudinal steel lap splice in the plastic hinge region appeared to significantly fail at low ductility level.

  • PDF

Vibration reduction design of the Hangzhou Bay cable-stayed bridges

  • Liu, Weiqing;Xu, Xiuli;Wang, Rengui;Wang, Zijun;Wu, Xiaolan
    • Structural Engineering and Mechanics
    • /
    • 제24권3호
    • /
    • pp.339-354
    • /
    • 2006
  • Hangzhou Bay Bridge spans the Hangzhou Bay and is located at Zhejiang province in the southeast seacoast of China. The total length of the bridge is 36 km. The bridge is composed of bridge approaches made up of multi-span prestressed concrete box girders and two cable-stayed bridges over the north and south navigable spans respectively. The seismic response analysis of the bridge model shows that if the navigable spans are designed as the routine earthquake-resistance system, the displacements and internal forces in pylons, piers and deckes are too large to satisfy the anti-seismic requirement of the structure. Therefore, the seismic reduction design was carried out by using viscous dampers to dissipate the kinetic energy of the structure both longitudinally and transversely. Using the vibration reduction system and aiming at the reasonable optimal goal, the purpose to reduce the seismic responses in south and north navigable spans has been achieved.

Estimation of elastic seismic demands in TU structures using interactive relations between shear and torsion

  • Abegaz, Ruth A.;Lee, Han Seon
    • Earthquakes and Structures
    • /
    • 제19권1호
    • /
    • pp.59-77
    • /
    • 2020
  • The code static eccentricity model for elastic torsional design of structures has two critical shortcomings: (1) the negation of the inertial torsional moment at the center of mass (CM), particularly for torsionally-unbalanced (TU) building structures, and (2) the confusion caused by the discrepancy in the definition of the design eccentricity in codes and the resistance eccentricity commonly used by engineers such as in FEMA454. To overcome these shortcomings, using the resistance eccentricity model that can accommodate the inertial torsional moment at the CM, interactive relations between shear and torsion are proposed as follows: (1) elastic responses of structures at instants of peak edge-frame drifts are given as functions of resistance eccentricity, and (2) elastic hysteretic relationships between shear and torsion in forces and deformations are bounded by ellipsoids constructed using two adjacent dominant modes. Comparison of demands estimated using these two interactive relations with those from shake-table tests of two TU building structures (a 1:5-scale five-story reinforced concrete (RC) building model and a 1:12-scale 17-story RC building model) under the service level earthquake (SLE) show that these relations match experimental results of models reasonably well. Concepts proposed in this study enable engineers to not only visualize the overall picture of torsional behavior including the relationship between shear and torsion with the range of forces and deformations, but also pinpoint easily the information about critical responses of structures such as the maximum edge-frame drifts and the corresponding shear force and torsion moment with the eccentricity.

The new criterion on performance-based design and application to recent earthquake codes

  • Azer A. Kasimzade;Emin Nematli;Mehmet Kuruoglu
    • Earthquakes and Structures
    • /
    • 제24권1호
    • /
    • pp.11-20
    • /
    • 2023
  • "Performance-based design (PBD)" is based on designing a structure with choosing a performance target under design criteria to increase the structure's resistance against earthquake effect. The plastic hinge formation is determined as one of the fundamental data in finite elements nonlinear analysis to distinguish the condition of the structure where more significant potential damage could occur. If the number of plastic hinges in the structure is increased, the total horizontal load capability of the structure is increased, also. Theoretically, when the number of plastic hinges of the plane frame structure reaches "the degree of hyperstaticity plus one", the structure will reach the capability of the largest ultimate horizontal load. As the number of plastic hinges to be formed in the structure increases towards the theoretical plastic hinge number (TPHN), the total horizontal load capability of the structure increases, proportionally. In the previous studies of the authors, the features of examining the new performance criteria were revealed and it was formulated as follows "Increase the total number of plastic hinges to be formed in the structure to the number of theoretical plastic hinges as much as possible and keep the structure below its targeted performance with related codes". With this new performance criterion, it has been shown that the total lateral load capability of the building is higher than the total lateral load capability obtained with the traditional PBD method by the FEMA 440 and FEMA 356 design guides. In this study, PBD analysis results of structures with frame carrier systems are presented in the light of the Turkey Building Earthquake Code 2019. As a result of this study, it has been shown that the load capability of the structure in the examples of structures with frame carrier system increases by using this new performance criterion presented, compared to the results of the examination with the traditional PBD method in TBEC 2019.

벽체 단부의 횡보강근 양에 따른 변형능력의 평가 (Effect of Edge Confinement on Deformation Capacity in the Isolated RC Structural Walls)

  • 한상환;오영훈;이리형
    • 콘크리트학회논문집
    • /
    • 제11권6호
    • /
    • pp.101-112
    • /
    • 1999
  • Structural walls have been mostly used for the design of reinforced concrete buildings in seismic areas because they play a role as an efficient bracing system and offer great potential for lateral load resistance and drift control. The lateral resistance system for the earthquake load should be designed to have enough ductility and stable hysteretic response in the critical regions where plastic deformation occurred beyond yielding. The behavior of the reinforced concrete element to experience large deformation in the critical areas by a major earthquake is affected by the performance of the confined core concrete. Thus, the confinement of concrete by suitable arrangements of transverse reinforcement results in a significant increase in both the strength and ductility of compressed concrete. This paper reports the experimental results of reinforced concrete structural walls for wall-type apartment structure under axial loads and cyclic reversal of lateral loads with different confinement of the boundary elements. The results show that confinement of the boundary element by open 'U'-bar and cross tie is effective. The shear strength capacity is not increased by the confinement but deformation capacity is improve.

Structural robustness of RC frame buildings under threat-independent damage scenarios

  • Ventura, Antonio;De Biagi, Valerio;Chiaia, Bernardino
    • Structural Engineering and Mechanics
    • /
    • 제65권6호
    • /
    • pp.689-698
    • /
    • 2018
  • This study focuses on a novel procedure for the robustness assessment of reinforced concrete (RC) framed structures under threat-independent damage scenarios. The procedure is derived from coupled dynamic and non-linear static analyses. Two robustness indicators are defined and the method is applied to two RC frame buildings. The first building was designed for gravity load and earthquake resistance in accordance with Eurocode 8. The second was designed according to the tie force (TF) method, one of the design quantitative procedures for enhancing resistance to progressive collapse. In addition, in order to demonstrate the suitability and applicability of the TF method, the structural robustness and resistance to progressive collapse of the two designs is compared.

필로티형 저층 내력벽주택의 내진설계 고려사항 (Considerations for Seismic Design of Low-Rise Residential Bearing Wall Buildings with Pilotis)

  • 이승제;엄태성
    • 한국지진공학회논문집
    • /
    • 제23권1호
    • /
    • pp.31-42
    • /
    • 2019
  • In this study, the results of an analytical investigation on the seismic behavior of two residential 4-story bearing wall buildings with pilotis, each of which has symmetric or unsymmetric wall arrangement at their piloti level, are presented. The dynamic characteristics and lateral resistance of the piloti buildings were investigated through linear elastic and nonlinear static analyses. According to the results, the analytical natural period of vibration of the piloti buildings were significantly shorter than the fundamental period calculated in accordance with KBC 2016. In the initial elastic behavior, the walls resisting in-plane shear contributed to the lateral stiffness and strength, while the contribution of columns resisting flexural moments in double curvature was limited. However, after the shear cracking and yielding of the walls occurred, the columns significantly contributed to the residual strength and ductility. Based on those investigations, design recommendations of low-rise bearing wall buildings with piloti configuration are given.

콘크리트 중력식 댐의 내진 안전성 평가 (Evaluation of the Seismic Safely of Concrete Gravity Dams)

  • 소진호;정영수;김용곤
    • 한국지진공학회논문집
    • /
    • 제6권1호
    • /
    • pp.33-41
    • /
    • 2002
  • 최근 1995년 일본의 고베 및 1999년도에 터키와 대만 등지에서 일어난 강진으로 많은 사상자와 피해가 발생되었고 일본 및 대만의 경우 일부 댐의 피해가 발생되었다. 댐의 경우 지진 발생시 국부적인 구조물의 손상뿐만 아니라 주변 주거지역에 많은 인명피해를 유발하기 때문에 국내에서도 내진설계기준 강화 이전의 콘크리트 중력식 댐에 대한 내진 안전성 평가의 필요성을 인식하게 되었다. 본 연구에서는 미국, 일본 및 캐나다의 내진설계기준 및 안전성 평가기법을 분석하여 국내 실정에 적합한 내진 안전성 평가 지침을 마련하였다. 평가단계는 제3단계로 구성하였다. 제1단계는 기초 문헌자료를 이용한 내진 안전성 평가 필요여부를 구분하는 예비평가단계이며 제2단계 평가는 진도법을 적용한 유사정적해석을 수행하여 성능기준 만족여부를 판단한다. 제3단계 평가는 제2단계를 만족하지 못하였을 경우 대상구조물에 동적해석을 적용하여 정밀한 평가를 수행한 후 성능기준을 평가한다. 본 연구에서는 현재 국내에서 운영중인 콘크리트 중력식 댐을 선정하여 본 평가 방법을 적용하였다.

간편법을 이용한 액상화 평가 기준에 대한 고찰 (Overview on Standards for Liquefaction Triggering Evaluation using the Simplified Method)

  • 김연준;고길완;;김병민;김동수
    • 한국지진공학회논문집
    • /
    • 제24권5호
    • /
    • pp.197-209
    • /
    • 2020
  • Evidence of liquefaction during the 2017 Pohang earthquake has highlighted the urgent need to evaluate the current seismic design standard for liquefaction in Korea, particularly the liquefaction triggering standard. With the simplified method, which is the most popular method for evaluating liquefaction triggering, the factor of safety for liquefaction triggering is calculated via the cyclic stress ratio (CSR) and the cyclic resistance ratio (CRR). The parameters in the CSR and CRR have undergone changes over time based on new research findings and lessons learned from liquefaction case-histories. Hence, the current design standard for liquefaction triggering evaluation in Korea should also reflect these changes to achieve seismic safety during future earthquakes. In this study, liquefaction susceptibility criteria were discussed initially and this was followed by a review of the current liquefaction triggering codes/guidelines in other countries and Korea. Next, the parameters associated with the CSR such as the maximum ground acceleration, stress reduction factor, magnitude scaling factor, and overburden correction factor were discussed in detail. Then, the evaluation of the CRR using the SPT N-value and CPT qc-value was elaborated along with overburden and clean-sand correction factors. Based on this review of liquefaction triggering evaluation standards, recommendations are made for improving the current seismic design standard related to liquefaction triggering in Korea.

중공 단면을 갖는 취수탑의 내진 안전성 평가 (Seismic Safety Analysis of Intake Tower with Hollow Inside Section)

  • 배정주;김용곤;이지호;한상훈
    • 한국안전학회지
    • /
    • 제24권2호
    • /
    • pp.55-61
    • /
    • 2009
  • Seismic Safety Analysis of Intake Tower is very important because failure of intake tower may incur huge chaos on the modem society. Recently, there has been growing much concern about earthquake resistance of existing structures. This research demonstrates the dynamic fluid pressure calculation using added mass simulation. The actual safety evaluation has been conducted through not only the static analysis but also the dynamic analysis. According to the analysis results, the vibration incurred by earthquake may induce considerable damage to the hydraulic structure. Therefore, the appropriate design process out of exact calculation is quite necessary.