• 제목/요약/키워드: earthquake-resistance design

검색결과 171건 처리시간 0.028초

화강토와 점토지반에 연직으로 타입된 PHC말뚝의 수평지지력에 관한 연구(지반공학) (A Study on Lateral Bearing Capacity of PHC Piles Driven Vertically in Decomposed Granite and Clayey Soil)

  • 문영민;이문수;이대재
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.466-470
    • /
    • 2000
  • Recently, the calculation of horizontal bearing capacity of piles foundation has been considered very important for earthquake or wind resistant design in Korea. This study deals with the lateral resistance of PHC pile instead of vertical capacity for earthquake resistant design as well as wind. As case study, the prediction values were compared with measured ones based on ASTM. During this research, Matlock & Reese, Davisson & Gill, Broms and Chang's methods were selected in calculating prediction of lateral resistance of PHC piles. In decomposed granite and clayey soils, The result showed that prediction values proposed by Matlock & Reese(Davisson & Gill), Chang and Broms were smaller values than real values. four proposed methods by Matlock & Reese(Davisson & Gill) and Chang based on lateral deflection and Broms by ultimate lateral resistance turned out valid in view of engineering practice.

  • PDF

Dynamic shear strength of unreinforced and Hairpin-reinforced cast-in-place anchors using shaking table tests

  • Kim, Dong Hyun;Park, Yong Myung;Kang, Choong Hyun;Lee, Jong Han
    • Structural Engineering and Mechanics
    • /
    • 제58권1호
    • /
    • pp.39-58
    • /
    • 2016
  • Since the publication of ACI 318-02, the concrete capacity design (CCD) method has been used to determine the resistance of unreinforced concrete anchors. The regulation of steel-reinforced anchors was proposed in ACI 318-08. Until ACI 318-08, the shear resistance of concrete breakout for an unreinforced anchor during an earthquake was reduced to 75% of the static shear strength, but this reduction has been eliminated since ACI 318-11. In addition, the resistance of a hairpin-reinforced anchor was calculated using only the strength of the steel, and a regulation on the dynamic strength was not given for reinforced anchors. In this study, shaking table tests were performed to evaluate the dynamic shear strength of unreinforced and hairpin-reinforced cast-in-place (CIP) anchors during earthquakes. The anchors used in this study were 30 mm in diameter, with edge distances of 150 mm and embedment depths of 240 mm. The diameter of the hairpin steel was 10 mm. Shaking table tests were carried out on two specimens using the artificial earthquake, based on the United States Nuclear Regulatory Commission (US NRC)'s Regulatory Guide 1.60, and the Northridge earthquake. The experimental results were compared to the current ACI 318 and ETAG 001 design codes.

외부접합공법의 내진보강효과에 미치는 접합부의 영향 (Influence of Joint on Retrofitting Effect by Exterior Steel Frames of Existing RC Buildings)

  • 안충원;민찬기;노은철;한홍수;김태완
    • 한국지진공학회논문집
    • /
    • 제19권4호
    • /
    • pp.183-194
    • /
    • 2015
  • In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit for seismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shear resistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method, structural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed that depending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore, the strength reduction coefficient of the anchor needs to be considered at the joint design.

연결부분 설계에 의한 일반교량의 내진성능 (Earthquake Resistance Capacity of a Typical Bridge by Connection Design)

  • 국승규
    • 한국전산구조공학회논문집
    • /
    • 제23권5호
    • /
    • pp.543-550
    • /
    • 2010
  • 내진설계는 타 설계의 요구사항, 즉 각 구조부재의 설계강도가 소요강도 이상이어야 한다는 것을 만족해야 하는 동시에 지진발생시 구조물의 항복과정을 규명하여 제시하여야 한다. 이러한 요구사항이 추가되는 이유는 타 하중과는 차별되는 지진하중의 불확실성이다. 이 연구에서는 일반교량을 해석대상교량으로 선정하고 연결부분의 설계를 수행하여 연성파괴메카니즘을 확보하는 과정을 제시하였다. 이와 같은 과정으로부터 구조부재의 강도 증가 또는 지진저감장치 도입 등의 비용증가 없이 타 설계에서 요구되는 구조부재의 강도 이내에서 내진성능을 확보할 수 있다는 것을 확인하였다.

소방배관 형상에 따른 배관 내진해석 (Seismic Analysis of Firefighting Pipe Networks)

  • 최호성;이재오
    • 한국화재소방학회논문지
    • /
    • 제33권5호
    • /
    • pp.149-154
    • /
    • 2019
  • 지진 발생 시 소방배관의 안전성은 무엇보다 중요하다. 국내의 경우 국가화재안전기준(NFSC)에 따라 사양위주의 설계를 하고 있지만 특별한 성능이 요구되는 건물에는 공학적인 성능위주 설계를 적용하고 있다. 소방배관의 경우 트리방식을 적용하여 왔다. 하지만 여러 단점으로 인해 최근에는 그리드방식, 루프방식을 적용하고 있다. 국내 소방 배관 내진설계는 NFPA 13 의 cook book 방식을 적용하고 있지만, 신뢰성을 확보하기 위해서는 공학적인 해석이 필요하다. 국내에서 적용 중인 NFPA 13 기준은 ASCE 와 ASME 의 지침을 준용한 것으로 지진이나 배관의 공학적 해석이 부족한 기술자들이 사용하도록 만들어 놓은 설계방식이다. 국내 내진설계는 버팀대에 대한 검토만 진행되고 있다. 하지만 신뢰성 있는 해석을 위해서는 배관의 내압, 지속 하중에 의한 힘, 지진과 같은 하중 조건에서의 다양한 해석이 요구된다. 공학적 내진해석을 통해 트리방식 배관은 그리드나 루프 방식의 배관에 비해 안전성이 떨어지는 것을 알 수 있었으며, 응력 기반의 내진해석 방식과 변형률 기반의 해석방식을 비교한 결과 변형률 해석이 Over Stress 범위에서는 보수적인 결과 값을 보였다. 배관의 내진해석은 일률적인 계산을 통한 해석보다 공학적 해석을 통해 엔지니어가 본인의 의도에 맞게 해석을 하는 것이 좀 더 합리적이며, 여러 가지 해석조건을 고려하여 분석되어야 한다.

Why Worry about Earthquake in Regins of Moderate Seismicity : A Case-Study of Hong Kong

  • Kuang, Jun-Shang
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.111-119
    • /
    • 1998
  • This paper reports a part of research work on earthquake resistance consideration in regions of moderate seismicity, which is being carried out in the Department of Civil Engineering, Hong Kong University of Science & Technology. The possible seismic hazard in Hong Kong, which is located in a region of moderate seismicity, is described. A case study is presented to compare the wind and earthquake effects on Hong Kong buildings and to assess whether seismic analysis and desing is necessary for building structure. Potential problems of reinforced concrete buildings under earthquake effects in regions of moderate seismicity are discussed.

  • PDF

현행설계법 및 하중저항계수설계법에 의한 완전 조립식 교량 하부구조의 설계결과 비교 (Design Comparison of Totally Prefabricated Bridge Substructure Systems Designed by Present Design and LRFD Methods)

  • 김태훈;김영진;신현목
    • 한국지진공학회논문집
    • /
    • 제15권2호
    • /
    • pp.11-22
    • /
    • 2011
  • 개발된 완전 조립식 교량 하부구조에 대한 설계비교와 비선형 해석을 수행하였다. 조립식 교량 하부구조는 현행설계법과 하중저항계수설계법으로 설계하였다. 설계시에는 현 도로교설계기준에 규정된 DB-24 및 DL-24 설계활하중을 적용하였다. 이 연구는 비선형 유한요소해석을 통해서 완전 조립식 교량 하부구조의 현행 설계법인 KHBD (2005)와 AASHTO-LRFD (2007)를 평가하였다. 사용된 프로그램은 철근콘크리트 구조물의 해석을 위한 RCAHEST이다.

지진에 대한 강구조물의 피로손상도 추정법 (Fatigue Damage Assessment for Steel Structures Subjected to Earthquake)

  • 송종걸;윤정방;이동근
    • 한국강구조학회 논문집
    • /
    • 제9권1호통권30호
    • /
    • pp.95-105
    • /
    • 1997
  • Structures subjected to strong seismic excitation may undergo inelastic deformation cycles. The resulting cumulative fatigue damage process reduces the ability of structures and components to withstand seismic loads. Yet, the present earthquake resistance design methods focus mainly on the maximum displacement ductility, ignoring the effect of the cyclic responses. The damage parameters closely related to the cumulative damage need to be properly reflected on the aseismic design methods. In this study, two cumulative damage assessment methods derived from the plastic fatigue theory are investigated. The one is based on the hysteretic ductility amplitude, and the other is based on the dissipated hysteretic energy. Both methods can consider the maximum ductility and the cyclic behavior of structural response. The validity of two damage methods has been examined for single degree of freedom structures with various natural frequencies against two different earthquake excitations.

  • PDF

감쇠시스템을 적용한 라멘조 아파트의 내진성능평가 (Seismic Performance of the Framed Apartment Building Structure with Damping System)

  • 천영수;이범식;박지영
    • 토지주택연구
    • /
    • 제8권3호
    • /
    • pp.181-187
    • /
    • 2017
  • To proactively respond to internal and external changes such as the recent demographic change and rising demand for diversified housing types, this study investigated the framed-structure free plan public house model proposed by the LH to look at the seismic performance of framed-structure apartment according to damper system use through non-linear analysis. The effectiveness thereof was also examined in terms of performance and economy. As a result, the proposed damper system application method to framed-structure free plan public house model was found to meet the performance requirements of the present earthquake-resistant design (KBC2016) and effective to apply to designs. The max response displacement and max response acceleration were compared based on the nonlinear analysis. As a result, the building with damper system showed better earthquake resistance performance than earthquake-resistant structure thanks to the damper system, although the base shear of earthquake-resistant system was reduced by 20% in design. The damper system is expected to help reduce building damage while ensuring excellent earthquake resistance performance. In addition, the framework quantities of earthquake-resistant structure and structure with damping system were compared. As a result, columns were found to reduce concrete amount by about 3.9% and rebar, by about 7.3%. Walls showed about 12.6% reduction in concrete and about 10.7% in rebar. In terms of cost, framework construction cost including formwork and foundation expenses was expected to drop by about 5~6%.

가스시설물의 등가정적 해석에 의한 내진성능 평가 (The Estimation of earthquake-resistance for gas utility using Equivalent Static Analysis)

  • 고재필;홍성경;김준호;정석영
    • 한국가스학회지
    • /
    • 제6권4호
    • /
    • pp.23-32
    • /
    • 2002
  • 내진설계기준은 시설물의 사회적, 경제적 중요성과 구조적 특성이 잘 반영될 수 있도록 설정되어야 한다. 즉 우선적으로 시설물별로 중요성과 특성에 따른 내진설계의 기본적인 원칙이 설정되고 이에 따라 적절한 해석 및 설계, 시공방법이 결정되어야 한다. 한국가스공사의 평택과 인천 및 통영에 있는 가스생산선비들 중 LNG 저장탱크는 원자력 발전소 기준 내진설계가 적용되어 있다. 가스 생산선비 중 저장탱크 다음으로 중요한 시설로는 중앙조정실을 들 수 있다. 중앙조정실에서는 각종 설비의 조작 및 이상유무를 판단하고 조정하는 장비들이 갖추어져 있으므로 지진에 대한 내진설계가 더욱 중요한 곳이다. 이러한 이유로 평택생산기지 중앙조정실의 내진성능을 점검하였고, 그 방법으로 건축물에 적용되고 있는 등가정적 해석법에 의한 내진성능을 평가하였다.

  • PDF