• Title/Summary/Keyword: earthquake-resistance

Search Result 381, Processing Time 0.022 seconds

Effects of Material Nonlinearity on Seismic Responses of Multistoried Buildings with Shear Walls and Bracing Systems

  • Islam, Md. Rajibul;Chakraborty, Sudipta;Kim, Dookie
    • Architectural research
    • /
    • v.24 no.3
    • /
    • pp.75-84
    • /
    • 2022
  • Scads of earthquake-resistant systems are being invented around the globe to ensure structural resistance against the lateral forces induced by earthquake loadings considering structural safety, efficiency, and economic aspects. Shear wall and Bracing systems are proved to be two of the most viable solutions for seismic strengthening of structures. In the present study, three numerical models of a G+10 storied building are developed in commercial building analysis software considering shear wall and bracing systems for earthquake resistance. Material nonlinearity is introduced by using plastic hinges. Analyses are performed utilizing two dynamic methods: Response Spectrum analysis and nonlinear Time-history analysis using Kobe and Loma Prieta earthquake data and results are compared to observe the nonlinear behavior of structures. The outcomes exposed that a significant increase in the seismic responses occurs due to the nonlinearity in the building systems. It was also found that building with shear wall exhibits maximum resistance and minimum nonlinearity when subjected to dynamic loadings.

Seismic performance of RC frames retrofitted with haunch technique

  • Akbar, Junaid;Ahmad, Naveed;Alam, Bashir;Ashraf, Muhammad
    • Structural Engineering and Mechanics
    • /
    • v.67 no.1
    • /
    • pp.1-8
    • /
    • 2018
  • Shake table tests performed on five 1:3 reduced scale two story RC moment resisting frames having construction defects, have shown severe joint damageability in deficient RC frames, resulting in joint panels' cover spalling and core concrete crushing. Haunch retrofitting technique was adopted herein to upgrade the seismic resistance of the deficient RC frames. Additional four deficient RC frames were built and retrofitted with steel haunch; both axially stiffer and deformable with energy dissipation, fixed to the beam-column connections to reduce shear demand on joint panels. The as-built and retrofitted frames' seismic response parameters are calculated and compared to evaluate the viability of haunch retrofitting technique. The haunch retrofitting technique increased the lateral stiffness and strength of the structure, resulting in the increase of structure's overstrength. The retrofitting increased response modification factor R by 60% to 100%. Further, the input excitation PGA was correlated with the lateral roof displacement to derive structure response curve that have shown significant resistance of retrofitted models against input excitations. The technique can significantly enhance the seismic performance of deficient RC frames, particularly against the frequent and rare earthquake events, hence, promising for seismic risk mitigation.

A New Assessment of Liquefaction Potential Based on the Dynamic Test (진동시험에 기초한 액상화 상세예측법 개발)

  • Kim, Soo-Il;Choi, Jae-Soon;Kang, Han-Soo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.245-252
    • /
    • 2004
  • When some enormous earthquake hazards broke out in the neighboring Japan and Taiwan, many Korean earthquake engineers thought that seismic guidelines must be adjusted safely and economically to consider the moderate earthquake characteristics. In the present aseismic guideline for liquefaction potential assessment, a simplified method using SPT-N value and a detail method based on the dynamic lab-tests were introduced. However, it is said that these methods based on the equivalent stress concept to simplify an irregular earthquake are not reliable to simulate the kaleidoscopical characteristics of earthquake loading correctly. Especially, even though various data from the dynamic lab-test can be obtained, only two data, a maximum cyclic load and a number of cycle at an initial liquefaction are used to determine the soil resistance strength in the detailed method. In this study, a new assessment of liquefaction potential is proposed and verified. In the proposed assessment, various data from dynamic lab-tests are used to determine the unique soil resistance characteristic and a site specific analysis is introduced to analyze the irregular earthquake time history itself. Also, it is found that the proposed assessment is reasonable because it is devised to reflect the changeable soil behavior under dynamic loadings resulted from the generation and development of excess pore water pressure.

  • PDF

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.

A study on the characteristics of friction pendulum isolation bearings (마찰진자형 면진베어링의 특성 연구)

  • 김영중
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 2000.10a
    • /
    • pp.407-414
    • /
    • 2000
  • The friction pendulum type seismic isolation system (FPS) has been developed to provide a simple and effective way to achieve earthquake resistance for buildings . The major advantages are: the isolation frequency can be easily achieved by designing a curvature of the surface and does not depend on the supported weight of a structure. The function of carrying vertical load is separated to the function of providing horizontal stiffness. Next the friction provides sufficient energy dissipation to protect the structure from earthquake response and resistance to the weak external disturbances such as wind load and ground vibrations due to traffic. In this paper, the friction coefficients are evaluated from number of experiments on the FPS test specimens. The relations between friction coefficient and the test waveform, velocity, and pressure are reviewed and further works are discussed.

  • PDF

An Experimental Study on the Liquefaction Behavior under Various Loading Conditions (다양한 입력하중에서의 액상화 발생 특성 비교 연구)

  • Kim, Soo-Il;Hwang, Seon-Ju;Park, Keun-Bo;Choi, Jae-Soon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.320-327
    • /
    • 2005
  • Liquefaction characteristics of saturated sand under various dynamic loadings such as sinusoidal, wedge, increasing wedge and real earthquake loading are investigated focusing on the excess pore water pressure build up instead of liquefaction resistance strength in this paper. There are large differences between two types of earthquake loading - impact and vibration in liquefaction characteristics. The angle of phase change line of sinusoidal loading is very close to the vibration type, whereas the cumulative deviator stress and cumulative plastic strain are larger than two types of real earthquake loadings. On the other hand, the liquefaction characteristics of increasing wedge loadings are located in the range between vibration and impact earthquake loadings. It is concluded that the sinusoidal loading overestimates the resistance of soil under real earthquake loading. Based on results obtained, the increasing wedge loading can reflect the liquefaction behavior under real earthquake loadings more efficiently than sinusoidal loading based on equivalent uniform stress concept.

  • PDF

The Estimation of earthquake-resistance for gas utility using Equivalent Static Analysis (가스시설물의 등가정적 해석에 의한 내진성능 평가)

  • Koh J. P.;Hong S. K.;Kim J. H.;Jeong S. Y.
    • Journal of the Korean Institute of Gas
    • /
    • v.6 no.4 s.18
    • /
    • pp.23-32
    • /
    • 2002
  • The purpose of the present study is to analyze the response of Gas Utility subjected to Earthquake and to discuss the failure prediction of Kogas Storage Tank. Initially here, characteristics of Earthquake are reviewed and then earthquake-resistance Design is investigated based on previous earthquake hazard cases. Next, considering the distribution of the transverse permanent ground displacement and equivalent spring constant effect, formulae obtained by a beam theory are established to analyze PeungTak Center Control Room. This analysis was performed without consideration of axial effects. So the finite element analysis was used in order to consider the axial stiffness of Structure.

  • PDF

Fragility Curve of Steel Box Bridge Using RFPB Bearing (RFPB 받침을 사용한 Steel Box 교량의 손상도 곡선)

  • Lee, Jongheon;Seo, Sangmok;Kim, Woonhak
    • Journal of the Society of Disaster Information
    • /
    • v.7 no.3
    • /
    • pp.171-180
    • /
    • 2011
  • As a great earthquake hit east Japan recently, the interests for the necessity of earthquake resistant design and earthquake resistance ability of existent structures are much increased. The damage or collapse of a bridge, as a social overhead capital structure affects socially and economically. Thus the evaluation of earthquake resistance ability of these structures is very important. The reviewing methods for earthquake resistance ability are mostly deterministic. Although the deterministic methods are fit for the evaluation of safety of each member, they are not practical for the whole structure. For the evaluation of structural safety for earthquake, the method for the evaluation of fragility or damage is needed for some stages of damage. In this paper, fragility curves of steel box bridge using RFPB bearing for PGA, PGV, SA, SV, SI are constructed, and these are compared with the cases of FPB.

Influence of Joint on Retrofitting Effect by Exterior Steel Frames of Existing RC Buildings (외부접합공법의 내진보강효과에 미치는 접합부의 영향)

  • Ahn, Choong Weon;Min, Chan Gi;Noh, Eun Choul;Han, Hong Soo;Kim, Tae Wan
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.19 no.4
    • /
    • pp.183-194
    • /
    • 2015
  • In this paper, Nonlinear Static Pushover analysis method(NSP) is proposed which apply to RC buildings reinforced by external retrofit for seismic performance. Based on previous analysis and research, NSP is more developed by connection nonlinearity according to shear resistance mechanism such as dowel and adhesive resistance as major shear resistance elements. According to the proposed method, structural analysis for example buildings was carried out to evaluate seismic performance of buildings. And, it was confirmed that depending on shear strain and characteristics of joint resistant of external retrofitting are different from internal retrofitting. Furthermore, the strength reduction coefficient of the anchor needs to be considered at the joint design.

Dynamic Resistance of Anchor using Blasting Test and Numerical analysis for Earthquake (발파실험과 내진해석을 통한 Anchor의 동적 저항성에 관한 연구)

  • Choi, Kyung-Jip;Cho, Kook-Hwan
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.4
    • /
    • pp.500-511
    • /
    • 2017
  • Recently, as earthquakes have occurred in Gyeongju, interest in the stability of structures against vibration from earthquakes has increased. In Korea, the capacity of load resistance is mainly considered in the design of anchors. However, the vibration resistance characteristics of anchors have not been fully elucidated. The traditional type of anchor, which is a frictional resistance anchor, is often reported to fail due to vibration in construction procedures, such as blasting. The expansion type of anchor, on the other hand, could have more resistance to vibration but its capability of demonstrating vibratory resistance has to be investigated. In order to verify the vibratory resistance characteristics of expansion anchors against blasting and earthquake vibration, field tests and numerical analyses for seismic wave were performed. Field blasting test results show that the expansion anchor has better capability against vibratory load than does the frictional type anchor. Numerical analysis to earthquake also show that the expansion type anchor provides more resistance than does the frictional type anchor.