• Title/Summary/Keyword: earthquake simulation test

Search Result 117, Processing Time 0.025 seconds

Shaking Table Test of a 1/5 Scale 3-Story Nonductile infilled Reinforced Concrete Frame (조적채움벽이 있는 1/5 축소 3층 비연성 철근콘크리트 골조의 진동대 실험)

  • 이한선;우성우
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.541-546
    • /
    • 1998
  • The objective of this research is to observe the actual response of low-rise nonseismic moment-resisting infilled reinforced concrete frame subjected to varied levels of earthquake ground motions. First of all, the reduction scale for the model was determined as 1 : 5 considering the capacity of the shaking table to be used. This model was, then, subjected to the shaking table motions simulating Taft N21E component earthquake ground motions, whose peak ground accelerations(PGA`s) were modified to 0.12g, 0.2g, 0.3g, and 0.4g. The global behavior and failure mode were observed. The lateral accelerations and displacements at each story and local deformations at the critical portions of structure were measured. Before and after each earthquake simulation test, free vibration tests were performed to find the changes in the natural period of the model.

  • PDF

Estimation of Dynamic Properties of Steel Liquid Storage Tank by Shaking Table Test (진동대 실험에 의한 강재 액체저장탱크의 동특성 분석)

  • Choi, Hyoung Suk;Park, Dong Uk;Kim, Sung Wan;Kim, Jae Min;Baek, Eun Rim
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.21 no.4
    • /
    • pp.153-161
    • /
    • 2017
  • Liquid storage tank is one of the major infrastructures and generally used to store gases, drinking and utilizing water, dangerous fluids, fire water and so on. According to the recent reports and experiences, the tank structures are damaged in many earthquakes due to their low energy dissipating capacity. Therefore, many researchers have been tried to know the dynamic properties of the tanks including liquids. However, vary limited experimental studies are carried out using relatively small tank models. In this study, a series of shaking table tests are performed with maximum 2 m cubic rectangular liquid storage tanks made of steel to measure the natural frequency and estimate damping coefficient of impulsive and convective mode of the tanks. Especially, the damping values under different shapes and excitation methods are estimated by logarithmic decrement method and half power band-pass method and compared with current design code and standards such as ASCE 7, Eurocode 8 and NZS. Test results show that the impulsive mode damping is around 2% which is proposed by general standards and codes but the impulsive mode damping is 0.13% average that is slightly lower than the code recommendation.

Performance Analysis of Water Systems under Hazardous Conditions

  • Liu, Gee-Yu
    • 한국방재학회:학술대회논문집
    • /
    • 2010.02a
    • /
    • pp.10-15
    • /
    • 2010
  • The performance analysis of water systems is very important to urban disaster mitigation. It will benefit the task of preparedness and emergency response through a more practical and more quantitative approach. In this research work, an overview of hydraulics of water system has been provided. A methodology for such implementation based on scenario simulation and hydraulic analysis has been developed. The water system of Taipei Water Department was selected as a test bed for case study. Its serviceability following a major earthquake around Taipei metropolitan area has been quantified.

  • PDF

Shaking Table Tests of A 1/5-Scale 3-Story Nonductile Reinforced Concrete Frame (1/5 축소 비연성 3층 철근콘크리트 골조의 진동대 실험)

  • 이한선;우성우;허윤섭;고동우;강귀용;김상대;정하선;송진규
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1997.10a
    • /
    • pp.581-586
    • /
    • 1997
  • The objective of this study is to investigate the behavior of a 1/5-scale 3-story nonductile reinforced concrete frame subjected to earthquake excitation. For this purpose, Taft N21E earthquake accelerogram was simulated by using 3m${\times}$5m shaking table. When the input acceleration is compared to that of output, it can be found that simulation of shaking table is excellent. From the results of test with Taft N21E earthquake accelerogram adjusted to peak ground acceleration(PGA) 0.06g and 0.12g(maximum acceleration in korea seismic code) the model responded in elastic behavior and it is found that the existing building in our country are safe against the levels of PGA 0.06g and 0.12g.

  • PDF

Numerical Simulation on the Shaking Table Test considering Soil Structure Interaction (구조물과 지반의 동적 상호작용을 고려한 진동대 시험에 관한 수치 시뮬레이션)

  • Lee, Sung-Kyung
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.5 s.45
    • /
    • pp.21-28
    • /
    • 2005
  • This paper proposes a shaking table test considering the dynamic soil strcuture interaction (SSI) by using the accelerations measured from superstructure and shaking table. The proposed method based on the substructure method is that only superstructure is used as an experimental model and dynamic soil stiffness is reflected on the controller of shaking table for soil model. At the moment, an experimental superstructure is excited by a shaking table with the motion required to emulate the dynamic behavior of total SSI system. First, the validity of the proposed method is verified by the verification model of numerical simulation, which is derived from the equation of motion of SSI system under consideration. Also, the applicability of the proposed method to shaking table test is numerically verified from the simulation model incorporating the transfer function of shaking table.

Verification of Hybrid Structural Test Technique by Shaking Table Test of a Linear 2-Dimensional Frame Model (소형선형 평면뼈대모형의 진동대실험을 통한 하이브리드실험 기법의 검증)

  • Cho, Sung-Min;Choi, In-Gyu;Jung, Dae-Sung;Kim, Chul-Young
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.14 no.6
    • /
    • pp.33-43
    • /
    • 2010
  • This paper deals with the hybrid structural test technique which has been introduced and studied currently in Korea. In this study, a Mini-MOST system which was developed as a part of NEES research was modified and improved to reduce the total simulation time to half of the original system. Using the proposed system together with the 2 dimensional small steel frame specimen, the validity and efficiency of the hybrid test technique is investigated. Even though the hybrid test has been developed as an alternative to the shaking table test and has been studied and applied for a long time in several countries, no attempt has been made to compare it directly with the shaking table test. Therefore, in this study, the hybrid test results are compared with those of the shaking table test as well as with a numerical simulation for the verification of hybrid test. From the comparison and analysis of the test results, it is concluded that the hybrid test can simulate the actual seismic behavior of structural systems very accurately and it can be a good alternative to the shaking table test.

Earthquake Analysis of Dam Floodgate Using Calibrated Added Mass (보정된 부가질량을 이용한 댐 수문의 지진해석)

  • Bea, Jung-Ju;Kim, Ho-Seung;Kim, Yong-Gon;Lee, Jee-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.13 no.5
    • /
    • pp.31-40
    • /
    • 2009
  • In this paper, a trial-error based method is presented to calibrate added mass models through numerical iterations minimizing the difference between the measured frequency data and its numerical simulation result for a dam floodgate. Earthquake analysis of the real floodgate for which the on-site hammering vibration test is performed show that the classical Westergaard added mass model gives relatively larger values in the maximum earthquake force and the maximum total displacement than the present added mass model, based on the calibration of on-site measurement data.

Evaluation of vibration characteristics according to changes in the fixing conditions of the electrical cabinet in power plants under an earthquake

  • Lee, Sang-Moon;Jeon, Bub-Gyu;Jung, Woo-Young
    • Earthquakes and Structures
    • /
    • v.23 no.3
    • /
    • pp.245-257
    • /
    • 2022
  • This study is a basic study on the seismic reinforcement method of anchors of fixed parts in order to reduce the effect of seismic motion that affects the facilities in the event of an earthquake. By applying the test method of ICC ES AC 156, a seismic simulation experiment was performed on the vibration table with three axes simultaneously using the number of connecting bolts between cabinets and channels as a parameter. In addition, the reliability of the experiment was verified using numerical analysis, and the part about the dynamic characteristics that could not be performed according to the experimental limit was investigated through numerical analysis. As a result of the experiment, it was confirmed that the natural frequency of the main body was increased due to the increase in the number of connecting bolts between the cabinet-channel. Accordingly, it was judged that the rigidity of the lower part of the cabinet was increased due to seismic reinforcement. It was analyzed that the impact delivered to the body was effectively reduced. In the future, if the reinforcement of the connection parts mentioned in this study is added to the existing seismic reinforcement of the electrical cabinets, it is expected that the damage to the electrical cabinets of the power plant equipment caused by an earthquake will be effectively reduced.

Real-Time Hybrid Testing Using a Fixed Iteration Implicit HHT Time Integration Method for a Reinforced Concrete Frame (고정반복법에 의한 암시적 HHT 시간적분법을 이용한 철근콘크리트 골조구조물의 실시간 하이브리드실험)

  • Kang, Dae-Hung;Kim, Sung-Il
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.11-24
    • /
    • 2011
  • A real-time hybrid test of a 3 story-3 bay reinforced concrete frame which is divided into numerical and physical substructure models under uniaxial earthquake excitation was run using a fixed iteration implicit HHT time integration method. The first story inner non-ductile column was selected as the physical substructure model, and uniaxial earthquake excitation was applied to the numerical model until the specimen failed due to severe damage. A finite-element analysis program, Mercury, was newly developed and optimized for a real-time hybrid test. The drift ratio based on the top horizontal displacement of the physical substructure model was compared with the result of a numerical simulation by OpenSees and the result of a shaking table test. The experiment in this paper is one of the most complex real-time hybrid tests, and the description of the hardware, algorithm and models is presented in detail. If there is an improvement in the numerical model, the evaluation of the tangent stiffness matrix of the physical substructure model in the finite element analysis program and better software to reduce the computational time of the element state determination for the force-based beam-column element, then the comparison with the results of the real-time hybrid test and the shaking table test deserves to make a recommendation. In addition, for the goal of a "Numerical simulation of the complex structures under dynamic loading", the real time hybrid test has enough merit as an alternative to dynamic experiments of large and complex structures.

Simulation of Dynamic in-situ Soil Properties for the Centrifuge Test (Hualien Site in Taiwan) (원심 모형 시험을 위한 동적 현장 지반 모사 기법 연구(대만 화련 지반))

  • Ha, Jeong-Gon;Lee, Sei-Hyun;Choo, Yun-Wook;Kim, Se-Hee;Kim, Dong-Soo
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.16 no.4
    • /
    • pp.27-36
    • /
    • 2012
  • The simulation of the field dynamic soil properties for soil modeling in the centrifuge test is important. In this study, the process of soil modeling based on the shear wave velocity profile is developed. From the resonant column test in each confining pressure, the shear wave velocity profile is expected and the modeling condition is determined by comparing it with that in the field. During the dynamic centrifuge test, the bender element test is performed for measuring the in-flight shear wave velocity profile, and the applicability of the proposed method was verified. This modeling method is applied to the centrifuge test of the Hualien Large-Scale Seismic test.