• Title/Summary/Keyword: earthquake energy

Search Result 908, Processing Time 0.024 seconds

Ductility demands of steel frames equipped with self-centring fuses under near-fault earthquake motions considering multiple yielding stages

  • Lu Deng;Min Zhu;Michael C.H. Yam;Ke Ke;Zhongfa Zhou;Zhonghua Liu
    • Structural Engineering and Mechanics
    • /
    • 제86권5호
    • /
    • pp.589-605
    • /
    • 2023
  • This paper investigates the ductility demands of steel frames equipped with self-centring fuses under near-fault earthquake motions considering multiple yielding stages. The study is commenced by verifying a trilinear self-centring hysteretic model accounting for multiple yielding stages of steel frames equipped with self-centring fuses. Then, the seismic response of single-degree-of-freedom (SDOF) systems following the validated trilinear self-centring hysteretic law is examined by a parametric study using a near-fault earthquake ground motion database composed of 200 earthquake records as input excitations. Based on a statistical investigation of more than fifty-two (52) million inelastic spectral analyses, the effect of the post-yield stiffness ratios, energy dissipation coefficient and yielding displacement ratio on the mean ductility demand of the system is examined in detail. The analysis results indicate that the increase of post-yield stiffness ratios, energy dissipation coefficient and yielding displacement ratio reduces the ductility demands of the self-centring oscillators responding in multiple yielding stages. A set of empirical expressions for quantifying the ductility demands of trilinear self-centring hysteretic oscillators are developed using nonlinear regression analysis of the analysis result database. The proposed regression model may offer a practical tool for designers to estimate the ductility demand of a low-to-medium rise self-centring steel frame equipped with self-centring fuses progressing in the ultimate stage under near-fault earthquake motions in design and evaluation.

Estimation of Plastic Energy Dissipation Amount of Multi-bent Spatial structure by Equivalent Linear Analysis

  • 이승재
    • 한국공간구조학회논문집
    • /
    • 제6권2호
    • /
    • pp.131-136
    • /
    • 2006
  • It is important to evaluate energy absorption capacity of frames required during a design earthquake. An inelastic computer analysis based on mathematical modelling of energy absorbing frames and elements makes it possible to evaluate required energy absorption capacity. But such an analysis sometimes consumes much computation time particularly in case of complicated structural system. This paper presents a proposal to predict energy absorption of multi-bent steel frames by simple equivalent linear method.

  • PDF

에너지 흡수효율에 의한 구조물간 내진 성능 비교 (Comparative Seismic Evaluation of Structures by Energy Absorption Efficiency)

  • 김장훈
    • 한국지진공학회논문집
    • /
    • 제5권3호
    • /
    • pp.37-43
    • /
    • 2001
  • 다양한 구조시스템간 반복하중에 대한 거동 성능을 비교하고자 에너지 개념을 확장하였다. 이로부터 에너지 흡수효율이 정의되었는데 이는 구조체의 누적에너지 흡수능력을 기준이 되는 탄성-완전소성시스템의 누적에너지 흠수량으로 나누어 무차원화한 것이다. 이를 위하여 반복하중실험으로부터 구한 실험결과들을 정리하여 에너지곡선의 형태로 표현하여야 한다. 제안된 방법을 이용하여 기하학적으로, 재료적으로 또한 구법이 서로 상이한 구조체간의 내진 성능에 대한 상대적이며 객관적인 비교가 가능해진다. 또한 이 방법의 가장 큰 장점 중의 하나는 구조물의 파괴형태와 관계없이 반복하중에 의한 힘-변위 관계만 주어지면 충분하다는 것이다. 제안된 방법을 두 시험체의 실험결과에 적용하여 그 타당성을 입증하여 보았다.

  • PDF

Seismic performance evaluation of a steel slit damper for retrofit of structures on soft soil

  • Mahammad Seddiq Eskandari Nasab;Jinkoo Kim;Tae-Sang Ahn
    • Steel and Composite Structures
    • /
    • 제51권1호
    • /
    • pp.93-101
    • /
    • 2024
  • This paper presents an experimental and analytical study on a steel slit damper designed as an energy dissipative device for earthquake protection of structures considering soil-structure interaction. The steel slit damper is made of a steel plate with a number of slits cut out of it. The slit damper has an advantage as a seismic energy dissipation device in that the stiffness and the yield force of the damper can be easily controlled by changing the number and size of the vertical strips. Cyclic loading tests of the slit damper are carried out to verify its energy dissipation capability, and an analytical model is developed validated based on the test results. The seismic performance of a case study building is then assessed using nonlinear dynamic analysis with and without soil-structure interaction. The soil-structure system turns out to show larger seismic responses and thus seismic retrofit is required to satisfy a predefined performance limit state. The developed slit dampers are employed as a seismic energy dissipation device for retrofitting the case study structure taking into account the soil-structure interaction. The seismic performance evaluation of the model structure shows that the device works stably and dissipates significant amount of seismic energy during earthquake excitations, and is effective in lowering the seismic response of structures standing on soft soil.

엇격자 유한차분법을 이용한 극지해역 지진파 모델링 (Earthquake Wave Propagation Using Staggered-grid Finite-difference Method in the Model of the Antarctic Region)

  • 오주원;민동주;이호용;박민규
    • 한국지구과학회지
    • /
    • 제32권6호
    • /
    • pp.640-653
    • /
    • 2011
  • 이 연구에서는 기존의 탄성파 모델링 알고리즘에 지진 송신원을 적용하고, 음향-탄성파 결합 매질을 구현하여 남극대륙 주변과 같은 극지해역에서 발생할 수 있는 지진파의 거동을 모사한다. 기존의 변위근사 유한차분법과 달리 속도-응력 식으로 구성되는 엇격자 유한차분법의 경우 다양한 송신원을 구현하는데 적합하므로 변위-속도-응력 식에 기초하여 개발된 3차원 엇격자 유한차분법 알고리즘과 이중 우력(Double Couple Forces)을 이용하여 구현한 지진 송신원을 접목시켜 지진파의 거동을 모사한다. 좌수향 주향이동단층, 정단층, 역단층 형태의 지진 송신원에 대해서 개발된 알고리즘을 검증한 결과 이론적으로 예측되는 P파의 초동을 정확히 모사할 수 있었고, 섭입대 모델에 대한 수치모형실험 결과 섭입대에서 역단층에 의해 발생된 후 대륙지각, 해양지각 및 해양에서 전파되는 지진파의 거동양상이 정확하게 모사되는 것을 확인할 수 있었다.

Seismic Retrofit after 921 Earthquake

  • Tsai, C.S.
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.18-20
    • /
    • 2000
  • At 1:47 a.m, local time on September 21, 1999, a strong earthquake measured 7.3 on the Richter scale struck central Taiwan evoking another two earthquakes a few seconds late to wake up unprepared people of this small island. It caused 2,465 people killed 11,305 injured about 10,000 buildings collapsed and around 41,000 severely damaged, The major concerns after the earthquake are how to have learned from this natural disaster and how to rebuild earthquake-proof buildings without rendering up safety within reasonable costs. Inevitable actions for redrafting the building codes have been taken to re-strengthen the existing and new structures. Structural analysis tools and computer programs adopted by most practicing engineers have been re-examined to take into account the effects of the vertical component of ground shakings on structural responses. Most private structures were repaired by traditional methods without considering upgrading seismic resistibility because of economical reasons. Buildings open to the public are under consideration possibly enforced by making regulations to be upgraded to satisfy revised building codes. In addition new rehabilitation technologies such as structural control have been moving much faster than before and have become accepted by the public due to frequent reports by media and specialists. Building codes related to base isolators and energy absorption systems are still under legislation and expected to be published soon. Most of the new structures under construction designed by the building codes promulgated before the earthquake have been reconsidered to comply with the new codes even though it is not compulsory. Efforts have been made by the government engineering and research communities and universities in an attempt to reduce structural damage for future earthquakes and to construct if possible Taiwan as an earthquake-proof island.

  • PDF

New site classification system and design response spectra in Korean seismic code

  • Kim, Dong-Soo;Manandhar, Satish;Cho, Hyung-Ik
    • Earthquakes and Structures
    • /
    • 제15권1호
    • /
    • pp.1-8
    • /
    • 2018
  • A new site classification system and site coefficients based on local site conditions in Korea were developed and implemented as a part of minimum design load requirements for general seismic design. The new site classification system adopted bedrock depth and average shear wave velocity of soil above the bedrock as parameters for site classification. These code provisions were passed through a public hearing process before it was enacted. The public hearing process recommended to modify the naming of site classes and adjust the amplification factors so that the level of short-period amplification is suitable for economical seismic design. In this paper, the new code provisions were assessed using dynamic centrifuge tests and by comparing the design response spectra (DRS) with records from 2016 Gyeongju earthquake, the largest earthquake in history of instrumental seismic observation in Korea. The dynamic centrifuge tests were performed to simulate the representative Korean site conditions, such as shallow depth to bedrock and short-period amplification characteristics, and the results corroborated with the new DRS. The Gyeongju earthquake records also showed good agreement with the DRS. In summary, the new code provisions are reliable for representing the site amplification characteristic of shallow bedrock condition in Korea.

Temporal and Spatial Variations of the ML 5.8 Gyeongju Earthquake on September 12, 2016

  • Lee, Gyeong Su;Kyung, Jai Bok;Lee, Sang Jun
    • 한국지구과학회지
    • /
    • 제39권4호
    • /
    • pp.342-348
    • /
    • 2018
  • An earthquake of $M_L$ 5.8 hit the Gyeongju area on September 12, 2016. A sequence of foreshock-mainshock-aftershock of 588 events with equal to or greater than magnitude 1.5 occurred for six months in this area. Around ninety-nine percentage (98.8%) of the total energy was released intensively within a day, and about 80% of the total events took place within a month after the Gyeongju earthquake. The epicentral distribution of aftershocks of major events ($M_L$ 5.1, 5.8, 4.5, and 3.5) were elongated in the direction of $N30^{\circ}E$. They correlate well with the focal mechanism solution. These facts support the inference that the Gyeongju earthquakes occurred on a sub-parallel subsidiary fault of the Yangsan fault zone or on the linking damage zones between Deokcheon and Yangsan fault. During the last six years before the Gyeongju earthquake, there were few events within 10-km radius from the epicenter. This seismic gap area was filled with a sequence of the Gyeongju earthquakes. The b value for aftershock of the Gyeongju earthquakes is 1.09.

도시기상 관측을 위한 메타데이터의 표준화 (Standardization of Metadata for Urban Meteorological Observations)

  • 송윤영;채정훈;최민혁;박문수;최영진
    • 한국대기환경학회지
    • /
    • 제30권6호
    • /
    • pp.600-618
    • /
    • 2014
  • The metadata for urban meteorological observation is standardized through comparison with those established at the World Meteorological Organization and the Korea Meteorological Administration to understand the surrounding environment around the sites exactly and maintain the networks and sites efficiently. It categorizes into metadata for an observational network and observational sites. The latter is again divided into the metadata for station general information, local scale information, micro scale information, and visual information in order to explain urban environment in detail. The metadata also contains the static information such as urban structure, surface cover, metabolism, communication, building density, roof type, moisture/heat sources, and traffic as well as the update information on the environment change, maintenance, replacement, and/or calibration of sensors. The standardized metadata for urban meteorological observation is applied to the Weather Information Service Engine (WISE) integrated meteorological sensor network and sites installed at Incheon area. It will be very useful for site manager as well as researchers in fields of urban meteorology, radiation, surface energy balance, anthropogenic heat, turbulence, heat storage, and boundary layer processes.

Local thin jacketing for the retrofitting of reinforced concrete columns

  • Yuce, Serkan Z.;Yuksel, Ercan;Bingol, Yilmaz;Taskin, Kivanc;Karadogan, H. Faruk
    • Structural Engineering and Mechanics
    • /
    • 제27권5호
    • /
    • pp.589-607
    • /
    • 2007
  • Two series of tests were conducted to investigate the behavior of local thin jacketing for the retrofitting of reinforced concrete (RC) columns. In the first series, four full-scale RC columns with a height of 400 cm and a 30 cm square cross-section were tested under constant axial load and reversed cyclic lateral displacements. The heavily damaged columns were retrofitted with local thin jacketing. Self-compacting concrete (SCC) was used in the production of 7.5 cm thick, four-sided jacketing. The height of the jacketing was 100 cm for one specimen and 200 cm for all others. In the second series, the retrofitted columns were retested with the same axial load and displacement history. The effectiveness of local thin jacketing in the retrofitting of RC columns was examined with respect to lateral strength, stiffness, inelastic load-deformation behavior and energy dissipation.