• 제목/요약/키워드: earthquake effect

검색결과 1,216건 처리시간 0.025초

능동제에 구조물의 지진에너지 응답 (Earthquake Energy Response of Actively-controlled Structures)

  • 민경원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.399-408
    • /
    • 2000
  • IN analyzing earthquake response of structures important focus is on their diaplacements and shear forces. However seismic technology of passive energy dissipation makes focus on the seismic energy distribution of structures. The passive dampers enhance the capability of energy dissipation by their hysteretic behavior thus preventing the structural plastic deformation. In this paper the building structure with an active controller is analyzed with the view of earthquake energy distribution under elastic and plastic behaviors. The active control makes an effect of increasing damping capability which absorbs most of the earthquake input energy. Finally the different active gains resulting from the plastic deformation are applied to the active analysis and control forces and earthquake energy response are compared.

  • PDF

Why Worry about Earthquake in Regins of Moderate Seismicity : A Case-Study of Hong Kong

  • Kuang, Jun-Shang
    • 한국지진공학회논문집
    • /
    • 제2권3호
    • /
    • pp.111-119
    • /
    • 1998
  • This paper reports a part of research work on earthquake resistance consideration in regions of moderate seismicity, which is being carried out in the Department of Civil Engineering, Hong Kong University of Science & Technology. The possible seismic hazard in Hong Kong, which is located in a region of moderate seismicity, is described. A case study is presented to compare the wind and earthquake effects on Hong Kong buildings and to assess whether seismic analysis and desing is necessary for building structure. Potential problems of reinforced concrete buildings under earthquake effects in regions of moderate seismicity are discussed.

  • PDF

지진전조현상 파악을 위한 전기장 효과에 의한 동물 이상 행동 실험 (Experiment on the Anomalous Animal Behaviors by Electric Field Effects for detecting Earthquake Precursors)

  • 경재복;윤장근
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2001
    • /
    • pp.57-64
    • /
    • 2001
  • There are some previous reports that some animals such as rats and birds move in a large group and act abnormally to avoid the large earthquake. This study is to experimentally testify what relations exist between the anomalous animal behavior and electric field effect, which is reported due to the piezoelectric effects in a basement rock before earthquake occurrences. When electric field is applied to the whole bottom of the cage, they show nervous behaviors such as grooming, washing their faces, standing on legs or running around in panic to avoid the electric field. When more strong electric field is applied, they jump with shrieking and mount on the electric line. The rat shows more sensitive anomalous behavior than the bird. Even though the current to the experimental birds and rats is just a few $\mu$A, they react in various ways. The anomalous animal behaviors under the small ground electric field may have some relations to the actual phenomena before great earthquake. This kind of study is quite worthy for the understanding of earthquake precursors.

  • PDF

Practical coherency model suitable for near- and far-field earthquakes based on the effect of source-to-site distance on spatial variations in ground motions

  • Yu, Rui-Fang;Abduwaris, Abduwahit;Yu, Yan-Xiang
    • Structural Engineering and Mechanics
    • /
    • 제73권6호
    • /
    • pp.651-666
    • /
    • 2020
  • In this study, the spatial variation mechanisms of large far-field earthquakes at engineering scales are first investigated with data from the 2008 Ms 8.0 Wenchuan earthquake. And a novel 'coherency cut-off frequency' is proposed to distinguish the spatial variations in ground motions in the low-frequency and high-frequency ranges. Then, a practical piecewise coherency model is developed to estimate and characterize the spatial variation in earthquake ground motions, including the effects of source-to-site distances, site conditions and neighboring topography on these variations. Four particular earthquake records from dense seismograph arrays are used to investigate values of the coherency cut-off frequency for different source-to-site distances. On the basis of this analysis, the model is established to simulate the spatial variations, whose parameters are suitable for both near- and far-field earthquake conditions. Simulations are conducted to validate the proposed model and method. The results show that compared to the existing models, the proposed model provides an effective method for simulating the spatial correlations of ground motions at local sites with known source-to-site distances.

지진하중을 받는 철근콘크리트 장주의 P-$\Delta$ 효과 (Seismic P-$\Delta$ Effects of Slender RC Columns in Earthquake Analysis)

  • 곽효경;김진국
    • 한국전산구조공학회논문집
    • /
    • 제19권4호
    • /
    • pp.375-387
    • /
    • 2006
  • 기존의 연구에서 가정된 모멘트-곡률 관계를 토대로 고정된 안정계수를 갖는 응답스펙트럼을 구성하여 동적 P-$\Delta$ 효과를 분석한 것과는 달리, 이 논문에서는 안정계수의 증가, 즉, 축력의 증가에 따른 하중-변위관계의 변화를 고려할 수 있도록하는 적층단면법을 토대로 실용범위의 세장비와 안정계수를 변화시켜가며, 해석을 수행하여 철근콘크리트 장주의 동적 P-$\Delta$ 효과를 분석하였다. 다양한 지진에 대한 보편화된 결과를 얻기 위해 각기 다른 60개의 입력지진을 사용하였다. 또한, 수평지진과 수직지진을 동시에 작용하여 해석을 수행해 수직지진에 따른 P-$\Delta$ 효과를 살펴보았다. 해석결과, 철근콘크리트 장주의 최대변형은 축력, P-$\Delta$ 효과 및 수직지진의 영향을 거의 받지 않는 반면, 부재 내력은 축력에 의한 강성과 항복강도의 증가에 의해 증가하기 때문에, 철근콘크리트 장주의 내진설계시 축력효과를 고려하여 설계할 경우 P-$\Delta$ 효과 또는 수직지진에 대한 추가적인 영향은 고려하지 않아도 될 것으로 판단된다.

Effect of higher modes and multi-directional seismic excitations on power plant liquid storage pools

  • Eswaran, M.;Reddy, G.R.;Singh, R.K.
    • Earthquakes and Structures
    • /
    • 제8권3호
    • /
    • pp.779-799
    • /
    • 2015
  • The slosh height and the possibility of water spill from rectangular Spent Fuel Storage Bays (SFSB) and Tray Loading Bays (TLB) of Nuclear power plant (NPP) are studied during 0.2 g, Safe Shutdown Earthquake (SSE) level of earthquake. The slosh height obtained through Computational Fluid dynamics (CFD) is compared the values given by TID-7024 (Housner 1963) and American concrete institute (ACI) seismic codes. An equivalent amplitude method is used to compute the slosh height through CFD. Numerically computed slosh height for first mode of vibration is found to be in agreement the codal values. The combined effect in longitudinal and lateral directions are studied separately, and found that the slosh height is increased by 24.3% and 38.9% along length and width directions respectively. There is no liquid spillage under SSE level of earthquake data in SFSB and TLB at convective level and at free surface acceleration data. Since seismic design codes do not have guidelines for combined excitations and effect of higher modes for irregular geometries, this CFD procedure can be opted for any geometries to study effect of higher modes and combined three directional excitations.

Investigation of short column effect of RC buildings: failure and prevention

  • Cagatay, Ismail H.;Beklen, Caner;Mosalam, Khalid M.
    • Computers and Concrete
    • /
    • 제7권6호
    • /
    • pp.523-532
    • /
    • 2010
  • If an infill wall in a reinforced concrete frame is shorter than the column height and there is no initial gap between the column and the infill wall, the short column effect can occur during an earthquake shaking. This form of damage is frequently observed in many earthquake-damaged buildings all around the world and especially in Turkey. In this study, an effective method, which consists of placing additional infill wall segments surrounding the short column, to prevent this type of failure is examined. The influence of adding infill wall in the reduction of the shear force in the short column is also investigated. A parametric study is carried out for one-storey infilled frames with one to five bays using the percentage of the additional infill wall surrounding the short column and the number of spans as the parameters. Then the investigation is extended to a case of a multistorey building damaged due to short column effect during the 1998 Adana-Ceyhan earthquake in Turkey. The results show that the addition of the infill walls around the potential short columns is an effective way to significantly reduce the shear force.

Dynamic Analysis of Sand-Clay Layered Ground Considering Viscous Effect of Clay

  • Kim, Yong-Seong
    • 한국농공학회논문집
    • /
    • 제48권7호
    • /
    • pp.45-52
    • /
    • 2006
  • A cyclic viscoelastic-viscoplastic constitutive model for clay is incorporated into an effective stress based seismic response analysis to describe viscous effect of clay layer to sand layer during earthquake. The seismic response against main shock of 1995 Hyogoken Nambu Earthquake is analyzed in the present study. Acceleration responses in both clay layer and just upper liquefiable sand layer are damped due to viscous effect of clay. A cyclic viscoelastic-viscoplastic constitutive model for clay was implemented into a FEM code, and $Newmark{\beta}$ method was employed for the time discretization in the finite element formulation. Seismic responses were simulated by numerical method with recorded data at Port Island, Kobe, Japan. As results of this study, it was found that a cyclic viscoelastic-viscoplastic constitutive model can give good description of dynamic behavior characteristics including viscoelastic effect.

교량의 내진설계에 있어서 점성감쇠기능받침의 감쇠계수 영향평가 (Effect of Damping Coefficients in Earthquakes Resistant Design with Viscous Dampers for Bridges)

  • 정상모
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.399-406
    • /
    • 2000
  • Viscous dampers have been utilized as bearings and STU`s (Shock Transmission Unit) in earthquake resistant designs for bridges. Some viscous dampers are used as energy dissipators on one hand, but some dampers such as STU`s are used as fixing devices during an earthquake on the other hand. This paper discusses the effect of viscous dampers on the response of bridge with respect to the magnitude of damping coefficients. For this purpose, a typical bridge was taken as an example, and time-history dynamic analysis have been carried out. The input seismic data used in the analyses are relevant to the response spectra in the Koreans design code. The results show that there is an optimum value of coefficient considered most effective in the design. A STU with a large value of coefficient seems to make its support fixed. The response of the bridge is not much sensitive to the variation of the damping coefficients.

  • PDF

Effect of shear wall location in rigid frame on earthquake response of roof structure

  • Ishikawa, Koichiro;Kawasaki, Yoshizo;Tagawa, Kengo
    • Structural Engineering and Mechanics
    • /
    • 제11권6호
    • /
    • pp.605-616
    • /
    • 2001
  • The purpose of this study is to investigate the effect of the shear wall location in rigid frames on the dynamic behavior of a roof structure due to vertical and horizontal earthquake motions. The study deals with a gabled long span beam supported by two story rigid frames with shear walls. The earthquake response analysis is carried out to study the responses of the roof: vibration mode, natural period, bending moment and horizontal shear force of the bearings. The study results in the following conclusions: First, a large horizontal stiffness difference between the side frames is caused by the shear wall location, which results in a large vertical vibration of the roof and a large shear force at the side bearings. Second, in this case, the seismic design method for ordinary buildings is not useful in determining the distribution of the static equivalent loads for the seismic design of this kind of long span structures.