• 제목/요약/키워드: earthquake damage potential

검색결과 104건 처리시간 0.02초

Study on response of a new double story isolated structure under earthquakes

  • Hang Shan;Dewen Liu;Zhiang Li;Fusong Peng;Tiange Zhao;Yiran Huo;Kai Liu;Min Lei
    • Earthquakes and Structures
    • /
    • 제27권1호
    • /
    • pp.17-29
    • /
    • 2024
  • The traditional double story isolated structure is a derivative of the base isolated and inter-story isolated structures, while the new double story isolated structure represents a novel variation derived from the traditional double story isolated structure. In order to investigate the seismic response of the new double story isolated structure, a comprehensive structural model was developed. Concurrently, models for the basic fixed, base isolated, inter-story isolated, and traditional double story isolated structures were also established for comparative analysis. The nonlinear dynamic time-history response of the new double story isolated structure under rare earthquake excitations was analyzed. The findings of the study reveal that, in comparison to the basic fixed structure, the new double story isolated structure exhibits superior performance across all evaluated aspects. Furthermore, when compared to the base isolated and inter-story isolated structures, the new double story isolated structure demonstrates significant reductions in inter-story shear force, top acceleration, and inter-frame displacement. The horizontal displacement of the new double story isolated structure is primarily localized within the two isolation layers, effectively dissipating the majority of input seismic energy. In contrast to the traditional double story isolated structure, the new design minimizes displacements within the inter-isolation layer situated in the central part of the frame, as well as mitigates the overturning forces acting on the lower frame column. Consequently, this design ensures the structural integrity of the core tube, thereby preventing potential collapse and structural damage.

Semi-active storey isolation system employing MRE isolator with parameter identification based on NSGA-II with DCD

  • Gu, Xiaoyu;Yu, Yang;Li, Jianchun;Li, Yancheng;Alamdari, Mehrisadat Makki
    • Earthquakes and Structures
    • /
    • 제11권6호
    • /
    • pp.1101-1121
    • /
    • 2016
  • Base isolation, one of the popular seismic protection approaches proven to be effective in practical applications, has been widely applied worldwide during the past few decades. As the techniques mature, it has been recognised that, the biggest issue faced in base isolation technique is the challenge of great base displacement demand, which leads to the potential of overturning of the structure, instability and permanent damage of the isolators. Meanwhile, drain, ventilation and regular maintenance at the base isolation level are quite difficult and rather time- and fund- consuming, especially in the highly populated areas. To address these challenges, a number of efforts have been dedicated to propose new isolation systems, including segmental building, additional storey isolation (ASI) and mid-storey isolation system, etc. However, such techniques have their own flaws, among which whipping effect is the most obvious one. Moreover, due to their inherent passive nature, all these techniques, including traditional base isolation system, show incapability to cope with the unpredictable and diverse nature of earthquakes. The solution for the aforementioned challenge is to develop an innovative vibration isolation system to realise variable structural stiffness to maximise the adaptability and controllability of the system. Recently, advances on the development of an adaptive magneto-rheological elastomer (MRE) vibration isolator has enlightened the development of adaptive base isolation systems due to its ability to alter stiffness by changing applied electrical current. In this study, an innovative semi-active storey isolation system inserting such novel MRE isolators between each floor is proposed. The stiffness of each level in the proposed isolation system can thus be changed according to characteristics of the MRE isolators. Non-dominated sorting genetic algorithm type II (NSGA-II) with dynamic crowding distance (DCD) is utilised for the optimisation of the parameters at isolation level in the system. Extensive comparative simulation studies have been conducted using 5-storey benchmark model to evaluate the performance of the proposed isolation system under different earthquake excitations. Simulation results compare the seismic responses of bare building, building with passive controlled MRE base isolation system, building with passive-controlled MRE storey isolation system and building with optimised storey isolation system.

600MPa급(SM 570 TMC) 고성능강 기둥-보 용접접합부의 탄소성 거동에 관한 연구 (A Study on Elasto-Plastic Behavior of Column-to-Beam Welded Connection with 600MPa Class High Performance Steel)

  • 김종락;오영석;백기열;장성연
    • 한국강구조학회 논문집
    • /
    • 제20권6호
    • /
    • pp.783-792
    • /
    • 2008
  • 최근 초고층 건축물의 수요에 대응하여 고성능 고강도 강재에 대한 수요가 급증하고 있으며 고층건축물에 대한 지진 피해에 대한 인식이 확산되면서 건축구조용강에 대한 요구 성능이 점차 증가하는 추세이다. 이러한 수요에 의해 600MPa 급 강재가 출현 되었으며 현재 강교량 및 초고층 건축물에 적용하려고 많은 연구가 이루어지고 있다. 새로운 강재를 적용한 골조의 수평력에 대한 거동은 자료가 부족한 실정이다. 특히 인성에 관해서는 일반구조용 강재를 적용한 기둥 보 접합부의 소성변형율과 비교하여 고강도강을 적용한 기둥보 접합부의 소성변형율 관련 설계자료가 절실히 필요하다. 따라서 본 연구에서는 600MPa급(SM570 TMC) 강재를 적용한 기둥-보 접합부의 초기연구로서 논스캘럽과 추천형스 캘럽 상세의 실구조물 규모의 기둥-보 용접접합부 실험체를 제작, 내진성능실험을 통해 구조성능을 평가하였다. 기존의 일반구조용 SM490 강재를 적용한 기존의 연구와 비교 분석하여 초고층 건축물에 적용을 위한 내진설계자료 및 제작상의 주의사항을 제시하였다.

가상시나리오에 따른 남해안 지진해일 특성 연구 (Analysis of Tsunami Characteristics of Korea Southern Coast Using a Hypothetical Scenario)

  • 신범식;김동석;김동환;이상엽;조시범
    • 한국해안·해양공학회논문집
    • /
    • 제36권2호
    • /
    • pp.80-86
    • /
    • 2024
  • 전 세계적으로 대규모 지진이 다발적으로 발생하고 있다. 특히, 2011년 동일본 대지진으로 인해 동아시아 일대의 지각이 긴장상태에 있으며, 향후 발생할 수 있는 지진 활동에 대한 우려와 불확실성이 더욱 가중되고 있다. 동해안 지진해일에 대한 대책으로 국립재난안전연구원에서는 동해안을 대상으로 지진해일 수치모의를 통해 지진해일의 범람 특성 분석 및 침수예상도 작성에 관한 연구를 수행한 바 있다. 그러나 남해안의 경우 동해안에 비해 지진해일에 관한 연구가 매우 부족한 실정이다. 남해안의 경우 조차가 1~4 m로 조석의 영향을 무시할 수 없을 정도이기 때문에 조석의 영향이 지진해일 전파특성에 미치는 영향을 분석할 필요성이 있다. 남해안에 영향을 미칠 수 있는 지진해일 발생지는 해저의 단층운동이 활발한 유구열도(Ryukyu lsland)와 난카이트러프 단층대이다. 과거 남해안은 지진해일의 직접적인 피해가 없었으나, 지진해일 발생 가능성은 항시 존재하기 때문에 사전에 대비할 수 있는 연구가 필요하다. 따라서 본 연구에서는 남해안에 영향을 미칠 수 있는 지진해일 가상시나리오에 대한 지진해일 수치모의를 하였다. 아울러 조석과 지진해일의 상호작용으로 연안에서 나타나는 해일 전파특성을 분석하고자 한다. 이는 남해안 지진해일 위험성 평가를 통해 남해안에서 발생할 수 있는 지진해일 대비에 활용될 것으로 판단된다.