Browse > Article

A Study on Elasto-Plastic Behavior of Column-to-Beam Welded Connection with 600MPa Class High Performance Steel  

Kim, Jong Rak (숭실대학교 건축공학과)
Oh, Young Suk (대전대학교 건축공학과)
Baek, Ki Youl (CS구조엔지니어링)
Chang, Sung Yun (동부제철(주) 건재사업부)
Publication Information
Journal of Korean Society of Steel Construction / v.20, no.6, 2008 , pp. 783-792 More about this Journal
Abstract
While the recent high demand for mega-tall buildings has led to the development of high-performance and high-strength steels, the requirements for architectural-structure-performance steel have been raised as engineers recognize the potential damage that an earthquake can wreak on a tall building. A 600MPa-class steel has emerged to meet such need, and many studies are currently exploring its practical applications on civil engineering works and mega-tall buildings. The available data on the horizontal-force behaviors of structures built with such new steel, however, are still insufficient. There is an urgent need to look into its design data, especially its toughness, and to compare the plastic strain ratios of column-to-beam connections using high-strength steel and regular steel. One of the first studies on the behavior of a column-to-beam connection using 600MPa-class steel (SM570 TMC), this thesis analyzes such steel's structural performance by conducting a structural test on seismic resistance on a full-scale column-to-beam welded connection with non-scallop and recommended-scallop details. Compared with the previous studies on SM490, this thesis evaluates the weldability of SM570 TMC and presents the latter's seismic design data for use in testing its practical application.
Keywords
High-performance.high-Strength Steels; TMC steels; Column-to-beam; Toughness; Plastic strain ratio; seismic design;
Citations & Related Records
연도 인용수 순위
  • Reference
1 김종락, 임성우, 김성배, 박양희, 이상익(2002) 패널존 강성에 따른 고강도강 기둥-보 접합부의 인성에 관한 연구, 한국강구조학회 학술발표대회논문집, pp.533-538
2 이철호, 전상우, 김진호(2002) RBS 철골모멘트접합부의 내진 거동평가를 위한 반복재하 실물대 실험, 한국강구조학회논문집, Vol.14 No.4, pp.557-566
3 대한건축학회(2006) 건축구조설계기준 및 해설
4 金鍾洛 外 3人(1984) '柱はり溶接接合部の力學的性狀および破斷に及ぼす影響について一厚板鋼板を用いた柱はり溶接接合部の破斷性狀に關する實驗的硏究 その2一', 日本建築學會論, 文昭和59年12月10日
5 日本建築學會(2001) 鋼構造接合設計指針
6 Edoardo M. Marino, Masayoshi Nakashima, Khalid M. Mosalam(2005) Comparison of European and Japanese seismic design of steel building struct ures, Engineering Structures, pp.827-840
7 김종락, 김성배, 채승윤, 황미선(2000) 고강도강 기둥과 보접합부의 소성변형능력에 관한 연구-보단부 스캘럽 상세의 영향, 한국강구조학회 학술발표대회논문집, pp.222-227
8 SAC Joint Venture(2000) Recommended Seismic Design Criteria for New Steel Moment-Frame Buildings, FEMA-350
9 日本建築學會(1998) 鋼構造限界狀態設計指針.同解說
10 김종락, 김성배(2003) 고강도강(570N/$mm^{2}$) 기둥-보 접합부의 용접형식과 접합부상세가 인성에 미치는 영향에 관한 연구, 대한건축학회논문집 구조계 19권 3호, pp.33-40
11 Eurocode 8(2003) Final Draft of Eurocode 8: Design of Structures for Earthquake Resistance-Part 1: European Committee for Standardization
12 AISC(2005) Specification for Structural Steel Buildings
13 SAC Joint Venture(1997) Protocol for Fabrication, Inspection, Testing, and Documentation of Beam-Column Connection Tests and other Experimental Specimens Report No. SAC/BD-97/02 Version 1.1
14 한국강구조학회(2006) 강구조설계
15 AISC(2005) Seismic Provisions for Structural Steel Buildings incl. Supp. No. 1 s
16 이철호, 박종원(1998) 반복재하 실물대 실험에 의한 컬럼-트리형식 철골모멘트 접합부의 내진거동 연구, 한국강구조학회 논문집, Vol.10 No.4, pp.629-639
17 SAC Joint Venture(1999) Interim Guidelines, FEMA-267
18 이종관, 김기석, 최종교, 조재영, 윤태양(2006) 고성능 건설 신재료 개발현황, 대한건축학회지, Vol.50 No.12, pp. 34-42