• 제목/요약/키워드: ear protection

검색결과 55건 처리시간 0.019초

군대 청력 보호구(귀마개) 사용 및 착용 안전효과 실태조사 (The Research of Safety Effects by using a Hearing Protection(Ear Plug) in the Military)

  • 황성호;주묘경;박재범
    • 한국안전학회지
    • /
    • 제28권4호
    • /
    • pp.103-106
    • /
    • 2013
  • During a military service, noise has unusual characteristics, and constitutes a serious hazard to hearing of military servicemen. The purpose of this study is to understand the use of hearing protection and to assess the safety effects of hearing protection by using a ear plug in military. A total of 208(the army : 101, an air force : 107) serviceman were studied utilizing a questionnaire to know how many serviceman use the hearing protection and a total of 202(the army : 110, an air force : 92) serviceman were also studied using a ear fit validation device to assess the safety effects of hearing protection by using a ear plug. The results showed that the army have low used of hearing protection than an air force because of the low frequency of the noise exposure in the army. Personal attenuation rate was increased with 8 dB after fitting education. Therefore, it is recommended that use of proper hearing protection and fitting education was more suitable for military servicemen who were being exposed of the noise in domestic military.

Feedback Active Noise Control Based Voice Enhancing Ear-Protection System

  • Moon, Seong-Pil;Chang, Tae-Gyu
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1627-1633
    • /
    • 2017
  • This paper proposes a voice enhancing ear-protection system which is based on feedback active noise control(FBANC). The proposed system selectively suppresses the background noise and preserves the talking voice by controlling the adaptive algorithm with the voice activity period detection module. The noise reduction performance of the proposed noise canceling algorithm is analytically derived for the two key performance affecting parameters, i.e., electro-acoustic coupling distance and noise bandwidth. The proposed system is also implemented with a floating-point DSP system and its performance is experimentally tested to compare with the analytically derived results. The achieved levels of noise reduction for the three different noise bandwidths cases, i.e., 10Hz, 50Hz, and 90Hz, are high to show 17.05dB, 10.54dB and 8.99dB, respectively. The feasibility of the proposed system is also shown by the peak noise reduction achieved more than 25dB while preserving the voice component in the frequency range between 200-800Hz.

청력보호구 종류와 소음 방향에 따른 골전도 민감도의 영향 (Effects of Hearing Protection Methods and Noise Directions on Bone-Conduction Sensitivity)

  • 한우재;유재형
    • 한국음향학회지
    • /
    • 제32권5호
    • /
    • pp.423-429
    • /
    • 2013
  • 본 논문은 소음 속에서 다양한 청력보호구 착용 시 청자의 두개골 위에 골진동체 자극을 이용하여 가장 민감한 어음인지 부위를 찾고자 하였다. 20명의 정상청력의 남성과 여성(각 10명)에게 강강격의 이음절어를 사용하여 네 종류의 청력보호구 (이어폼, 이어플러그, 이어머프, 이어폼과 머프 동시 착용)와 다섯 군데의 골진동체 위치 (하악골각, 관절구, 관자놀이, 유양돌기, 정수리)를 네가지의 소음 방향(0, 90, 180, 270도)에 따라 어음인지역치검사를 시행하였다. 연구 결과는 다음과 같다. 1) 골진동체의 위치 중 관절구가 가장 역치가 낮았으며, 2) 청력보호구 종류는 이어폼과 머프를 동시에 착용(이중 보호) 하였을 때 가장 역치가 낮았다. 3) 소음 방향에 따라서는 90도에서 소음이 제시되었을 때 가장 낮은 역치를 나타냈으나, 4) 실험 대상자의 성별에 따라서는 유의미한 차이가 없었다. 따라서 소음성난청을 예방하며 소음 속에서 원활한 의사소통을 위해서는 이중보호 청력보호구 착용 하에서 관절구를 통한 언어전달이 가장 효율적이다.

Genetic diversity analysis in Chinese miniature pigs using swine leukocyte antigen complex microsatellites

  • Wu, Jinhua;Liu, Ronghui;Li, Hua;Yu, Hui;Yang, Yalan
    • Animal Bioscience
    • /
    • 제34권11호
    • /
    • pp.1757-1765
    • /
    • 2021
  • Objective: The swine leukocyte antigen (SLA) gene group, which is closely linked and highly polymorphic, has important biomedical significance in the protection and utilization of germplasm resources. However, genetic polymorphism analyses of SLA microsatellite markers in Chinese miniature pigs are limited. Methods: Eighteen pairs of microsatellite primers were used to amplify the SLA regions of seven miniature pig breeds and three wild boar breeds (n = 346) from different regions of China. The indexes of genetic polymorphism, including expected heterozygosity (He), polymorphic information content (PIC), and haplotype, were analyzed. The genetic differentiation coefficient (Fst) and neighbor-joining methods were used for cluster analysis of the breeds. Results: In miniature pigs, the SLA I region had the highest numbers of polymorphisms, followed by the SLA II and SLA III regions; the region near the centromere had the lowest number of polymorphisms. Among the seven miniature pig breeds, Diannan small-ear pigs had the highest genetic diversity (PIC value = 0.6396), whereas the genetic diversity of the Hebao pig was the lowest (PIC value = 0.4330). The Fst values in the Mingguang small-ear, Diannan small-ear, and Yunnan wild boars were less than 0.05. According to phylogenetic cluster analysis, the South-China-type miniature pigs clustered into one group, among which Mingguang small-ear pigs clustered with Diannan small-ear pigs. Haplotype analysis revealed that the SLA I, II, and III regions could be constructed into 13, 7, and 11 common haplotypes, respectively. Conclusion: This study validates the high genetic diversity of the Chinese miniature pig. Mingguang small-ear pigs have close kinship with Diannan small-ear pigs, implying that they may have similar genetic backgrounds and originate from the same population. This study also provides a foundation for genetic breeding, genetic resource protection, and classification of Chinese miniature pigs.

ITE 타입의 소음 차폐기용 소형 음향 필터의 설계 (Design of Small Acoustic Filter for ITE Type Noise Protector)

  • 이윤정;김필운;장용민;이상흔;조진호;김명남
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.479-487
    • /
    • 2004
  • The prevention of noise induced hearing loss is very important, because there is no treatment for it. There are some kinds of devices for hearing protection, and those are effective in preventing a noise induced hearing loss. However, people often resist the use of hearing protection devices because it is difficult to have a conversation. Therefore, a hearing protection device is must effective not only in hearing protection but also in preserving communication ability. In this paper, we proposed a small acoustic filter for ITE type noise protector to solving the problem about the difficulties of conversation. That is applied a principle of acoustic filters that have been used for a muffler of automobiles, guns, and etc. To find out the sound transmission characteristic at the eardrum, we regarded an acoustic filter and external ear canal as a coupled system. So, we simulated the coupled system with OrCad, and experimented with a designed acoustic filter and a 2 cc coupler which has the same transmission characteristic as the external ear canal has. We confirmed that it is possible to adjustment acoustic transmission characteristics through simulation of electrical model for acoustic filter and external ear and experiments using designed small acoustic filters.

황기(黃芪) 투여시기가 Cyclophosphamide 유발 흰쥐의 백혈구감소증에 미치는 영향 (The Effects of Astragali Radix on Cyclophosphamide-induced Leucopenia)

  • 장재민;고성규;신용철
    • 대한예방한의학회지
    • /
    • 제10권1호
    • /
    • pp.13-32
    • /
    • 2006
  • In order to indentify the effect of Astragali Radix(A.R) on cyclophosphamide(C.Y) induced leukopenia, A.R. extracts(EAR) were treated to mice orally, and blood sampling was done by periods. For the in vivo experiments, mice were divided into 4 groups, which treated EAR before, or after C.Y injection, or both, or none. Rapid normalization in the peripheral blood count of WBC, neutrophils, lymphocytes, RBC, and platelets observed in every EAR treated group regardless of the treatment periods of EAR. These studies suggest that, A.R. premedication can be effective in protection of bone marrow suppression during anticancer therapy.

  • PDF

귀 모형을 이용한 치과 핸드피스에 대한 소음 저감 장치의 효과 분석 (Effect of Noise Cancelling Devices on Dental Handpieces Using Ear Model)

  • 모승한;강준구;김익환;최형준;송제선;신유석
    • 대한소아치과학회지
    • /
    • 제47권1호
    • /
    • pp.62-69
    • /
    • 2020
  • 이 연구는 치과 핸드피스의 소음 수준과 소음 저감 장치의 효과를 평가하기 위한 것이다. 귀 모형은 치과용 핸드피스 작동 중에 내이에 전달되는 소음의 수준을 측정할 수 있도록 설계되었다. 소음의 크기는 귀 모형과 휴대용 소음 측정기를 사용하여 다양한 조건에서 측정되었다. 시판되는 4종의 소음 저감 장치를 귀 모형에 적용한 후 같은 조건에서 소음 수준을 측정한 뒤 비교하였다. 치과 핸드피스의 소음 수준은 조건에 따라 약 82.5 - 84.4 dB이었다. 4종의 소음 저감 장치를 적용했을 때 소음은 67.4 - 73.8 dB로 감소했다. 4종의 장치 모두 핸드피스의 소음을 줄이는데 유의한 효과가 있었다. 강도와 노출 시간을 고려할 때, 치과 소음은 치과 의료진에게 청력 손상을 일으킬 수 있다. 직업적 청력 손상 위험을 예방하기 위해 소음 저감 장치 사용을 고려할 수 있다.

옥수수 성 결정 메커니즘: 세포 사멸, 세포 방어, 세포주기 멈춤 (The Sex Determination Mechanisms in Maize: Cell Death, Cell Protection and Cell Cycle Arrest)

  • 김종철;이균오
    • 생명과학회지
    • /
    • 제16권4호
    • /
    • pp.699-703
    • /
    • 2006
  • 옥수수(Zea mays)는 단성화 식물로서 암꽃과 수꽃이 한 식물체내에 분리되어서 존재하며 수정시 이질성을 높이는 방향으로 진화되었다. 암꽃과 수꽃 각각은 단성화 상태로 분화하기 전에 한 개의 암술과 세 개의 수술 원시세포가 동일하게 형성된다. 옥수수가수꽃으로 분화할 때는 암술 원시세포에서 세포사멸 현상이 일어나는데 이것은 TASSELSEED 유전자들에 의해 매개된다. 이와 대조적으로 암꽃의 암술에서는 TASSELSEED 유전자들에 의한 세포사멸이 억제되는데 여기에는 SILKLESS1 유전자가 관여한다. 한편, 암꽃의 수술에서는 세포주기 멈춤 현상이 오랜 시간 지속되다가 결국에는 수술이 죽게 된다. 이때 세포주기를 조절하는 유전자인 CYCLIN B 와 WEE1 유전자가 이 과정에 참여한다. 이와 더불어, 지베렐린 생합성의 시간적 공간적 조절이 수술의 세포주기 멈춤의 원인이 된다. 본 총설에서는 옥수수의 성 결정 과정 중에 일어나는 세포사멸, 세포 방어, 세포주기 멈춤에 대하여 분자세포 발생 생물학 및 유전학적인 견지에서 고찰하였다.

일 소음작업장 근로자들의 소음에 대한 인식 및 태도, 예방행위에 관한 연구 (A Study on the Knowledge, Attitude and the Preventive Behavior of Noise of Workers Exposed to the Harmful Noise)

  • 김은희;김태경;정희영;권수자
    • 지역사회간호학회지
    • /
    • 제16권1호
    • /
    • pp.59-67
    • /
    • 2005
  • This study was to investigate knowledge, attitude and the preventive behaviour of noise of workers exposed to harmful noise and to provide primary data for noise-exposed workers' hearing conservation and the prevention of noise induced hearing loss. Method: The subjects were 104 workers who participated voluntarily in the questionnaire. The instrument used in this study was knowledge, attitude and practice on noise-induced hearing loss tool by Rhee & Yi (1996). The data were collected from August to September, 2002 with a self-administered questionnaire. Data were analyzed by SPSS 10.0 win program for finding frequency, percentage, mean, standard deviation, t-test, and ANOVA. Results: The average age of workers was 35.9 and the current average year of working at the noise place was $5{\sim}$10 years. In the group of previous noise-exposed workers, they showed significant difference in preventive behaviors (t=4.087, p=.048). In the group of current noise-exposed workers, they showed significant difference in recognition and attitude of noise(F=4.707, p=.004). Also, the duration of wearing ear protection equipment(t=2.383, p=.019), the feeling of wearing ear protection equipment(F=3.602, p=.031) and comfortable sense of wearing ear protection (F=3.919, p=.023) was significant in the preventive behaviour of noise. Conclusion: Considering the results above, we can recognize that there are close relations among the knowledge, attitude and the preventive behaviour of noise. Therefore, it is necessary to develop education - programs for noise-exposed workers' better understanding of noise and preventive behaviors

  • PDF

Individual Fit Testing of Hearing Protection Devices Based on Microphone in Real Ear

  • Biabani, Azam;Aliabadi, Mohsen;Golmohammadi, Rostam;Farhadian, Maryam
    • Safety and Health at Work
    • /
    • 제8권4호
    • /
    • pp.364-370
    • /
    • 2017
  • Background: Labeled noise reduction (NR) data presented by manufacturers are considered one of the main challenging issues for occupational experts in employing hearing protection devices (HPDs). This study aimed to determine the actual NR data of typical HPDs using the objective fit testing method with a microphone in real ear (MIRE) method. Methods: Five available commercially earmuff protectors were investigated in 30 workers exposed to reference noise source according to the standard method, ISO 11904-1. Personal attenuation rating (PAR) of the earmuffs was measured based on the MIRE method using a noise dosimeter (SVANTEK, model SV102). Results: The results showed that means of PAR of the earmuffs are from 49% to 86% of the nominal NR rating. The PAR values of earmuffs when a typical eyewear was worn differed statistically (p < 0.05). It is revealed that a typical safety eyewear can reduce the mean of the PAR value by approximately 2.5 dB. The results also showed that measurements based on the MIRE method resulted in low variability. The variability in NR values between individuals, within individuals, and within earmuffs was not the statistically significant (p > 0.05). Conclusion: This study could provide local individual fit data. Ergonomic aspects of the earmuffs and different levels of users experience and awareness can be considered the main factors affecting individual fitting compared with the laboratory condition for acquiring the labeled NR data. Based on the obtained fit testing results, the field application of MIRE can be employed for complementary studies in real workstations while workers perform their regular work duties.