• Title/Summary/Keyword: eQUEST

Search Result 37, Processing Time 0.032 seconds

A Comparative Study on Heating Energy Consumption of Multi-Family Apartment using EnergyPlus and eQUEST (EnergyPlus와 eQUEST를 이용한 공동주택의 난방에너지소비량 비교분석에 관한 연구)

  • Park, Doo-Yong;Yoon, Kap-Chun;Kim, Kang-So
    • Journal of the Korean Solar Energy Society
    • /
    • v.33 no.1
    • /
    • pp.48-56
    • /
    • 2013
  • Energy consumption analysis of multi-family apartment is an important area of research for the design of energy-saving housing. In this study, we selected a universal type of Flat-type apartments and analyzed the heating energy consumption of variables such as U-value, G-value, infiltration rate, heating setpoint and boiler efficiency with EnergyPlus and eQUEST. With these results, we identify the characteristics of EnergyPlus and eQUEST and provided base data for the design of energy-saving housing. The results indicate that infiltration rate is the most important factors to consider. And eQUEST heating energy consumption is approximately 10% higher compared to the EnergyPlus under same condition.

Exploring Pseudonymous based Schemes for Safegaurding Location Privacy in Vehicular Adhoc Network (VANET)

  • Arslan Akhtar Joyo;Fizza Abbas Alvi;Rafia Naz Memon;Irfana Memon;Sajida Parveen
    • International Journal of Computer Science & Network Security
    • /
    • v.23 no.2
    • /
    • pp.101-110
    • /
    • 2023
  • Vehicular Ad Hoc Network (VANET) is considered to be a subclass of Mobile Ad Hoc Networks (MANET). It has some challenges and issues of privacy which require to be solved before practical implementation of the system i.e., location preservation privacy. Many schemes have been proposed. The most prominent is pseudonym change based location preservation scheme. Safety message can be compromised when it sends via a wireless medium, consequently, an adversary can eavesdrop the communication to analyze and track targeted vehicle. The issue can be counter by use of pseudo identity instead of real and their change while communication proves to be a sufficient solution for such problems. In this context, a large amount of literature on pseudonym change strategies has been proposed to solve such problems in VANET. In this paper, we have given details on strategies proposed last two decades on pseudonym change based location preservation along with issues that they focus to resolve and try to give full understanding to readers.

Toward residential building energy conservation through the Trombe wall and ammonia ground source heat pump retrofit options, applying eQuest model

  • Ataei, Abtin;Dehghani, Mohammad Javad
    • Advances in Energy Research
    • /
    • v.4 no.2
    • /
    • pp.107-120
    • /
    • 2016
  • The aim of this research is to apply the eQuest model to investigate the energy conservation in a multifamily building located in Dayton, Ohio by using a Trombe wall and an ammonia ground source heat pump (R-717 GSHP). Integration of the Trombe wall into the building is the first retrofitting measure in this study. Trombe wall as a passive solar system, has a simple structure which may reduce the heating demand of buildings significantly. Utilization of ground source heat pump is an effective approach where conventional air source heat pump doesn't have an efficient performance, especially in cold climates. Furthermore, the type of refrigerant in the heat pumps has a substantial effect on energy efficiency. Natural refrigerant, ammonia (R-717), which has a high performance and no negative impacts on the environment, could be the best choice for using in heat pumps. After implementing the eQUEST model in the said multifamily building, the total annual energy consumption with a conventional R-717 air-source-heat-pump (ASHP) system was estimated as the baseline model. The baseline model results were compared to those of the following scenarios: using R-717 GSHP, R410a GSHP and integration of the Trombe wall into the building. The Results specified that, compared to the baseline model, applying the R-717 GSHP and Trombe wall, led to 20% and 9% of energy conservation in the building, respectively. In addition, it was noticed that by using R-410a instead of R-717 in the GSHP, the energy demand increased by 14%.

AN EVALUATION OF ENERGY PERFORMANCE IN SUPER HIGH-RISE APARTMENT HOUSING WITH EXTERIOR WINDOW TYPES

  • Sang-Ho Lee;Yong-Ho Park;Jong-Chan Lee
    • International conference on construction engineering and project management
    • /
    • 2009.05a
    • /
    • pp.1637-1642
    • /
    • 2009
  • This study evaluates the energy performance of super high-rise residential buildings with e-QUEST simulation and calculates the annual cooling and heating load. The result of this study have concluded that the most influential factor is the characteristics of the window and also suggest the most efficient window system from the result of calculation of different glasses' cooling and heating load. The result of this study shows that The most efficient method to enhance the energy performance is to use low reflective 3 pairs Low-E glass and Low-E coating(inside of outer glass) pair glass.

  • PDF

Energy and Economic Analysis of Heat Recovery Cogeneration Loop Integrated with Heat Pump System by Detailed Building Energy Simulation (건물 에너지 상세 해석을 통한 소형 열병합 발전 및 히트펌프 복합 시스템의 경제성 분석)

  • Seo, Dong-Hyun;Koh, Jae-Yoon;Park, Yool
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.21 no.2
    • /
    • pp.71-78
    • /
    • 2009
  • Up until recently, the energy and the economic analysis of a cogeneration system have been implemented by a manual calculation that is based on monthly thermal loads of buildings. In this study, a cogeneration system modeling validation with a detail building energy simulation, eQUEST, for a building energy and cost prediction has been implemented. By analyzing the hourly building electricity and thermal loads, it enables users to decide proper cogeneration system capacity and to estimate more accurate building energy consumption. eQUEST also verified the energy analysis when the heat pump system is integrated with the cogeneration system. The mechanical system configuration benefits from the high efficiency heat pump system while avoiding the building electricity demand increase. Economic analysis such as LCC (Life Cycle Cost) method is carried out to verify economical benefits of the system by applying actual utility rates of KEPCO(Korea Electricity Power COmpany) and KOGAS(KOrea GAS company).

Design Science in e-business Research

  • Park, Jin-Soo
    • Proceedings of the CALSEC Conference
    • /
    • 2004.02a
    • /
    • pp.15-20
    • /
    • 2004
  • Positivism ▣Quantitative research ▣Descriptive, predictive, explanatory ▣Quest for university laws ▣Concerned with the empirical testability of theories (·Causal models (if it's not about cause-and-effect, it's not Science)) ▣Assumptions:(·Existence of a priori fixed relationship within phenomena ·Regular patterns of causation ·Independent from human mind(objective, factual)(omitted)

  • PDF

Study of Design Strategy to Reduce Energy Consumption in a Standard Office Building (사무용 건물의 에너지 절감을 위한 요소별 성능 분석 및 디자인 전략에 관한 연구)

  • Yang, Ja-Kang;Kim, Chul-Ho;Kim, Kang-Soo
    • KIEAE Journal
    • /
    • v.16 no.2
    • /
    • pp.23-31
    • /
    • 2016
  • Purpose: Recently energy consumption is rapidly increasing due to continuous development of social evolution in various field. In this situation, there is a lot of effort to reduce this energy consumption in many ways, especially in building energy. Preceding studies already started to analyze the housing area such as zero energy house and passive house by researching annual building energy consumption, but to apply the results of housing to office building is insufficient since it has different consumption tendency. Method: In this study, eQuest program was used for simulation and the base model is selected among standard office building in ASHRAE 90.1. Variables are divided into passive and active factors for comparison. Result: In passive factors, glazing system showed the highest energy saving rate by 21.3% with triple low-e glass and enhancing wall u-value showed the lowest energy saving rate by 3.6% with 0.15 m2/K. In active factors, VAV system showed 30.9% energy saving rate when compared to CAV system, and heat exchanger showed 10.2% energy saving rate. For regeneration energy part, photovoltaic panel generated 10.4% of base annual energy usage.

A Review of Machine Learning Algorithms for Fraud Detection in Credit Card Transaction

  • Lim, Kha Shing;Lee, Lam Hong;Sim, Yee-Wai
    • International Journal of Computer Science & Network Security
    • /
    • v.21 no.9
    • /
    • pp.31-40
    • /
    • 2021
  • The increasing number of credit card fraud cases has become a considerable problem since the past decades. This phenomenon is due to the expansion of new technologies, including the increased popularity and volume of online banking transactions and e-commerce. In order to address the problem of credit card fraud detection, a rule-based approach has been widely utilized to detect and guard against fraudulent activities. However, it requires huge computational power and high complexity in defining and building the rule base for pattern matching, in order to precisely identifying the fraud patterns. In addition, it does not come with intelligence and ability in predicting or analysing transaction data in looking for new fraud patterns and strategies. As such, Data Mining and Machine Learning algorithms are proposed to overcome the shortcomings in this paper. The aim of this paper is to highlight the important techniques and methodologies that are employed in fraud detection, while at the same time focusing on the existing literature. Methods such as Artificial Neural Networks (ANNs), Support Vector Machines (SVMs), naïve Bayesian, k-Nearest Neighbour (k-NN), Decision Tree and Frequent Pattern Mining algorithms are reviewed and evaluated for their performance in detecting fraudulent transaction.

A Study of Optical Follow-up Pipeline for Gravitational-Wave transients using QUEST data

  • Kim, Yong Bum;Lee, Hyung Mok
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.38 no.1
    • /
    • pp.69.2-69.2
    • /
    • 2013
  • The direct detection of gravitational wave has a very important meaning as a basis for verification of the theory of relativity. Several laser interferometer detectors have attempted to detect GW directly (e.g. LIGO, VIRGO), but positional accuracy of GW detector is too wide (about 10~100sq deg) to find which objects emit GW. One of the main sources of GW is gamma-ray burst which can be detected even in electromagnetic wave. Then to verify Gamma-ray burst object as a GW source, we proceed EM follow-up observation with wide field of view. A first program initiating EM follow-ups to possible transients GW events has been developed and exercised by LIGO and VIRGO community in association with several partners. Using QUEST optical data, we tested the method of cross-convolution recommended by EM follow-up community. We will describe the results of that test.

  • PDF

HARQ Switching Metric of MIMO-OFDM Systems using Joint Tx/Rx Antenna Scheduling (송.수신 안테나 스케줄링에 기반한 MIMO-OFDM 시스템의 HARQ 스위칭 기법)

  • Kim, Kyoo-Hyun;Knag, Seoung-Won;Chang, Kyung-Hi;Jeong, Byung-Jang;Chung, Hyun-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.32 no.6A
    • /
    • pp.519-536
    • /
    • 2007
  • In this paper, we combine the Hybrid-Automatic Repeat reQuest (HARQ) algorithm with joint Tx and Rx antenna selection based on the reliability of the individual antennas links. The cyclic redundancy check (CRC) is applied on the data before being encoded using the Turbo encoder. In the receiver the CRC is used to detect errors of each antenna stream and to decide whether a retransmission is required or not. The receiver feeds back the transmitter with the Tx antennas ordering and the acknowledgement of each antenna (ACK or NACK). If the number of ACK antennas is higher than the NACK antennas, then the retransmission takes place from the ACK antennas using the Chase Combining (CC). If the number of the NACK antennas is higher than the ACK antennas then the ACK antennas are used to retransmit the data streams using the CC algorithm and additional NACK antennas are used to retransmit the remaining streams using Incremental Redundancy (IR, i.e. the encoder rate is reduced). Furthermore, the HARQ is used with the I-BLAST (Iterative-BLAST) which grantees a high transmission rate.