Abstract
Energy consumption analysis of multi-family apartment is an important area of research for the design of energy-saving housing. In this study, we selected a universal type of Flat-type apartments and analyzed the heating energy consumption of variables such as U-value, G-value, infiltration rate, heating setpoint and boiler efficiency with EnergyPlus and eQUEST. With these results, we identify the characteristics of EnergyPlus and eQUEST and provided base data for the design of energy-saving housing. The results indicate that infiltration rate is the most important factors to consider. And eQUEST heating energy consumption is approximately 10% higher compared to the EnergyPlus under same condition.
Keywords
Multi-family Apartment; Heating energy consumption; EnergyPlus; eQUEST;
Citations & Related Records
Times Cited By KSCI : 1  (Citation Analysis)
연도 인용수 순위
1 Yun KC, Kim KS, An Evaluation of Energy Performancein an office with Venetian Blinds in Summer, Architectural Institute of Korea, Vol.28, No.1, pp.285-292, 2012.1
2 C.K. Cheung, R.J. Fuller, M.B. Luther, Energy-efficient envelope design for high-rise apartments, Energy and Building, 2005
3 Yusuf Yıldız, Zeynep Durmus Arsan, Identification of the building parameters that influence heating and cooling energy loads for apartment buildings in hot-humid climates, Energy, 2011
4 United Satates Department of Energy, Energy Plus Manual Engineering Reference, Version3.0
5 United Satates Department of Energy, DOE-2 Engineers Manual, version 2.1A