• Title/Summary/Keyword: e-rater

Search Result 21, Processing Time 0.028 seconds

Perception of Korean Prosody by Native Speakers of English and Native Speakers of Korean (영어 원어민과 한국어 원어민의 한국어운율 인식)

  • Yi, So-Pae
    • MALSORI
    • /
    • no.65
    • /
    • pp.1-11
    • /
    • 2008
  • This study explored the perception of transplanted Korean prosody by NE (Native speakers of English) and NK (Native speakers of Korean) listeners. The Korean utterances of various sentence types produced by NE and NK were employed to transplant the original Korean prosody contours to the Korean utterances read by NE. Then, other NE and NK were instructed to rate the transplanted prosodic components. Results showed that the interactions between the two rater groups with the three factors (e.g., transplantation types & rater groups, sentence types & rater groups, sentence length & rater groups) turned out to be meaningful. Both rater groups preferred the combined effect of transplanted prosodic components (e.g. DP, DPI) to that of individual transplantation (e.g. I, D, P). Compared to NK, NE were more sensitive to duration change than pitch change whereas NK showed equal preference to the both. In sentence types such as De, Ex, Im, and Ta, NE perceived higher similarity than NK.

  • PDF

Intra- and Inter-rater Reliability of BioRescue (BioRescue의 측정자내와 측정자간 신뢰도)

  • Kim, Jin-hong;Choi, Bo-ram
    • The Journal of the Korea Contents Association
    • /
    • v.18 no.11
    • /
    • pp.348-352
    • /
    • 2018
  • BioRescue ($RMIng{\acute{e}}nierie$, Marseille, France) is able to assess dynamic and static balance when a test subject stands or sits over the platform. Although previous studies have examined the reliability of other balance measurement methods, little research has been conducted on the reliability of equipment such as BioRescue. This study examined the intra-rater and inter-rater reliability of BioRescue during balance assessment. Thirty-four healthy adults participated as subjects and two physical therapists participated as examiners to determine intra- and inter-rater reliability. BioRescue was used to conduct measurements during footprint (area and pressure), Romberg, and limit of stability tests. The footprint area and limit of stability tests yielded intra- and inter-rater reliability ICC values above 0.60 in all directions. However, the footprint pressure and Romberg tests yielded values below 0.60 in all directions. BioRescue showed good inter-rater and intra-rater reliability in measurements during footprint area and limit of stability tests. However, because the values of limits of stability show the difference between experienced and unskilled, skill is required for the accuracy of the equipment.

Reliability of the Visual Discrimination Scale on Oral Mucosa Pressure Ulcer for Healthcare Providers (의료인을 위한 구강점막욕창 시각적 감별도구의 신뢰도)

  • Uhm, Ju-Yeon;Kim, Myoung Soo
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.11
    • /
    • pp.443-450
    • /
    • 2020
  • The purpose of this study was to examine the inter-rater and intra-rater reliability of the oral mucosa pressure ulcer classification system based on the photographs. The study consisted of two stages; development and evaluation. In the developmental stage, 9 photographs of 82 were selected. In the evaluation stage, a total of 49 participants were invited web-based survey by e-mail. Cohen's weighted kappa and Krippendorff's alpha were used to define the inter-rater reliability. Nine photographs consisted of two, three, three, and one in normal, stage 1, stage 2, and stomatitis, respectively. The inter-rater reliabilities of wound care nurse specialist, intensive care nurse specialist, and dentist groups were 0.75, 0.70, and 0.78, respectively. The intra-rater reliability was 0.73. The inter-rater and intra-rater reliabilities of the oral mucosa pressure ulcer classification system showed substantially good agreement.

An Analysis of the Reliability and Validity of a Korean Version of the Mobility and Gait Assessment Tools for Patients with Stroke

  • Jang, Ho Young;Lee, Jeong-Hoon;Oh, Jung Lim;Lee, Hyun Soo;Lee, Suk Min
    • The Journal of Korean Physical Therapy
    • /
    • v.30 no.1
    • /
    • pp.29-34
    • /
    • 2018
  • Purpose: This study aimed to systematically analyze the reliability and validity of Korean versions of mobility and gait assessment tools for patients with stroke. Methods: Two reviewers conducted an independent literature search and systematically reviewed the literature. Literature published until June of 2017 was searched using search engines for electronic databases. The 2 reviewers reviewed the title and abstract of each article. Among the articles examined, we read the full text of those judged to be suitable for our study. We classified the selected data into research methods and results. The determination was made through mutual agreement. Results: The reviewers selected 5 articles related to the purpose of this study. The DGI was found to be moderately associated with BBS, 10MWT, and TUG in intra-rater reliability (ICC=0.92), inter-rater reliability (ICC=0.88), and concurrent validity tests. The FGA demonstrated a high level of reliability with intra-rater (ICC=0.92-0.95) and inter-rater reliability (ICC=0.91, 0.95). The intra-rater reliability of the RMI was high at ICC=0.98. Its concurrent validity showed a high association with STREAM and BI. The intra-rater reliability of the MAS was ICC=0.75-0.99. Its inter-rater reliability was very high, exceeding 0.99. The inter-rater reliability of the Tinetti-gait Scale was ICC=0.91, and its concurrent validity was moderately associated with the DGI, 10WMT, OLST, FM-L/E, and STS. Conclusion: The results of this study revealed that the reliability and validity of the Korean versions of the mobility and gait assessment tools were high.

Inter-Rater Reliability of the Modified Ashworth Scale of Spasticity (경련성 (spasticity) 평가를 위한 Modified Ashworth Scale의 측정자간 신뢰도)

  • Yi, Chung-Hwi;Current, Marion E.
    • Physical Therapy Korea
    • /
    • v.1 no.1
    • /
    • pp.1-9
    • /
    • 1994
  • This study was performed to determine the inter-rater reliability of manual tests of elbow, knee flexor, and ankle dorsiflexor muscle spasticity graded on the Modified Ashworth Scale. Two raters each independently graded the spasticity of 32 patients with intracranial lesions after moving the paretic limb passively through the available range of motion. The patients were asked to simultaneously squeeze therapeutic putty with their non-paretic hand for reinforcement. The ratings were compared by the Wilcoxon matched pairs signed-rank test and by the Kendall's coefficient of rank(tau) correlation. There was singificant correlation between two raters for spasticity at the elbow, knee flexor, and ankle dorsiflexor. The correlations of the two raters ranged from .6746 to .9308. The highest correlation was for the elbow with reinforcement and the lowest was for the knee without reinforcement. Poorer correlation was evident in the knee joint. The positive results of this study encourage the continued use of manual tests of muscle spasticity, using the Modified Ashworth Scale.

  • PDF

Investigating Learners' Perception on Their Engagement in Rating Procedures

  • Lee, Ho
    • English Language & Literature Teaching
    • /
    • v.13 no.2
    • /
    • pp.91-108
    • /
    • 2007
  • This study investigates learners' perception on their engagement in rating activities in the EFL essay-writing context. The current study aims to address the answers to the following research questions: 1) What attitude do students show about their participation in the rating tasks? and 2) which of three aspects (e.g. the degree of rating experience, the exposure to English composition instruction and learning, and proficiency level) significantly influences learners' rating activities? 104 EFL learners participated in the rater training session. After participants finished rater training session, they rated three sample essays and peer essays using the given scoring guide. Based on the analysis of survey responses that students made, students showed positive attitude toward their engagement in rating tasks. For research question 2, only L2 writing proficiency seriously affected students' perception on the rating tasks. Advanced level of subjects did not feel stressed by a grade of peers as low level of subjects did. They were also critical about the benefits of self- and peer-assessment, suggesting that a peer's feedback on their own essay was not so useful and that a self-rating does not fully help learners identify their writing proficiency.

  • PDF

The Relative·Absolute Reliability and Validity of Step Test in Patients with Chronic Stroke (만성 뇌졸중 환자들의 Step Test의 상대적·절대적 신뢰도와 타당도)

  • Lee, Byoungkwon;Choi, Hyunsoo;An, Seungheon
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.5 no.1
    • /
    • pp.43-53
    • /
    • 2017
  • Purpose : To examine the relative absolute reliability and validity of step test (ST) scores in subjects with chronic stroke. Method : A total of 27 stroke patients, participated in the study. A relative reliability index (intraclass correlation coefficient, ICC) was used to examine the level of agreement of inter-rater test-retest reliability for ST score. Absolute reliability indices, including the standard error of measurement(SEM) and the minimal detectable change (MDC), and limits of agreement by Bland and Altman analysis. The validity was demonstrated by spearman correlation of ST score with 10 m Walk Test (10mWT), Fugl-Meyer Assessment-Lower/Extremity (FMA-L/E)-total score, Berg Balance Scale (BBS)-total score. Result : An excellent inter-rater reliability in ST scores was found (paretic, ICC=0.993~0.996; nonparetic, ICC=0.982~0.991). In addition, excellent test-retest reliability was found (paretic, ICC=0.992; nonparetic, ICC=0.967). It all showed acceptable SEM of the ST score as paretic and nonparetic were 0.22 and 0.46 respectively (average score <10 %), and the MDC of the paretic and nonparetic were 0.61 and 1.27 respectively (possible highest score <20 %). indicating that measures had a small and acceptable measurement error. The ST score of paretic and nonparetic were also found to be significantly associated with 10MWT (r=0.77~0.79), FMA-LE scores (r=0.73~0.81) and BBS scores (r=0.72~0.76). Conclusion : The ST showed highly sufficient Inter-rater test-retest agreement and validity and acceptable measurement errors caused by due to chance variation in measurement. It also can be used by clinicians and researchers to assess the balance and mobility performance and monitor functional change in chronic stroke patients.

Perception of Transplanted English Prosody by American and Korean Listeners

  • Yi, So-Pae
    • Speech Sciences
    • /
    • v.14 no.1
    • /
    • pp.73-89
    • /
    • 2007
  • This study explored the perception of transplanted English prosody by thirty American and Korean, male and female listeners. The English utterances of various sentence types produced by Korean and American male speakers were employed to transplant the American prosody contours to Korean English utterances. Then, the thirty subjects were instructed to rate the transplanted prosodic components. Results showed that the interactions between the three factors (e.g., rater groups & transplantation types; transplantation types & sentence types; rater groups & transplantation types & sentence types) turned out to be meaningful. Both Americans and Koreans perceived the effectiveness of the combined effect of transplanted duration and pitch or duration and pitch and intensity. However, when perceiving individual prosodic components, Americans and Koreans showed different perceptual ratings. As for the overall prosody change, Americans perceived the change of intensity in a significant way but Koreans did not because intensity is not a crucial semantic factor in Korean. Americans rated the transplantation of duration alone as ineffective while Koreans rated otherwise. This was explained by the difference between English and Korean. The difference of perspective was also significant with different sentence types, especially with the three sentence types that had speech rates slower than other sentence types. A slower speech rate intensified the mismatch between the transplanted duration and the original pitch causing a negative impression on American listeners whereas this did not affect Korean listeners. Pedagogical implications of the findings are discussed.

  • PDF

Reliability of the scapular dyskinesis test yes-no classification in asymptomatic individuals between students and expert physical therapists

  • Lawrence S. Ramiscal;Lori A. Bolgla;Chad E. Cook;John S. Magel;Stephen A. Parada;Raymond Chong
    • Clinics in Shoulder and Elbow
    • /
    • v.25 no.4
    • /
    • pp.321-327
    • /
    • 2022
  • Background: Scapular dyskinesis is considered a risk factor for the shoulder pain that may warrant screening for prevention. Clinicians of all experience screen scapular dyskinesis using the scapular dyskinesis test yes-no classification (Y-N), yet its reliability in asymptomatic individuals is unknown. We aimed to establish Y-N's intra- and inter-reliability between students and expert physical therapists. Methods: We utilized a cross-sectional design using consecutive asymptomatic subjects. Six students and two experts rated 100 subjects using the Y-N. Cohen's kappa (κ) and Krippendorff's alpha (K-α) were calculated to determine intra- and inter-rater reliability. Results: Intra- and inter-rater values for experts were κ=0.92 (95% confidence interval [CI], 0.91-0.93) and 0.85 (95% CI, 0.84-0.87) respectively; students were κ=0.77 (95% CI, 0.75-0.78) and K-α=0.63 (95% CI, 0.58-0.67). Conclusions: The Y-N is reliable in detecting scapular dyskinesis in asymptomatic individuals regardless of experience.

Vitellogenin Induction by Rainbow trout (Oncorhynchus mykiss) Hepatocytes in Primary Culture (무지개송어의 간세포 초대배양에 의한 Vitellogeinin 합성 유도)

  • 여인규
    • Journal of Aquaculture
    • /
    • v.11 no.4
    • /
    • pp.557-564
    • /
    • 1998
  • Vitellogenin (VTG) induction in response estradiol-17${\beta}$ ($E_2$) were electrophoretically examined in primary hepatocyte cultures in rainbow trout. The hepatocytes were maintained as monolayers on positively charged dishes for up to 7 days. The viability of hepatocytes on Day 7 in cultures decreased about 20.7% and 23.6% with and without $E_2$, respecitively. The amount of DNA per dish also decreased to 13.7% and 14.0% with and without $E_2$, respectively. There were no differences in viability and DNA content between the control and $E_2$-treated culture. Moreover, the rate of VTG to total protein concentrations reached the maxium level at the addition of $10^{-6}$ M E2, to the incubation medium. However, the higher concentration of $10^{-5}$ M $E_2$ rater depressed the level.

  • PDF