• 제목/요약/키워드: e-Health System

검색결과 945건 처리시간 0.031초

미생물 간이 검사법 실시에 따른 학교급식소의 위생 및 건강관리 개선 효과 (Effects of Microbe Inspections in School Food Service Systems)

  • 한명숙;윤성태;임준;임정수
    • 보건교육건강증진학회지
    • /
    • 제23권3호
    • /
    • pp.53-63
    • /
    • 2006
  • Objectives: The purpose of this study was to analyze the effects of microbe inspections on the hygienic improvement of school food service systems. Methods: Thirty-three school food service systems in Incheon metropolitan city participated in the study from Sep. 2004 to Apr. 2005. Major items of microbe inspections were cutting boards, knives, kitchen towels, and kitchen staff's hands. The Rodac plate and hand plate were used to measure the surface contamination level of germs such as Staphylococcus aureus, Vibrio species, Salmonella species and E. coli. Results: This study compared the results of the inspections in Sep. 2004 and Apr. 2005. The surface contamination level of Staphylococcus aureus and Vibrio species on the knives and kitchen towels had significantly improved. However, the surface contamination level of E. coli on the hands of the kitchen staff had worsened. Conclusions: This study showed that microbe inspections could control the hygienic level of the school food service systems. In the future, microbe inspections should be actively used to improve sanitary conditions in the school lunch system.

Comparison of the Efficiency of Propylene Glycol and Distilled Water as Vehicles for Intracanal Medicaments.

  • Kota, K.;Cruz, E.V.;Iwaku, M.;Hoshino, E.
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2001년도 추계학술대회(제116회) 및 13회 Workshop 제3회 한ㆍ일 치과보존학회 공동학술대회 초록집
    • /
    • pp.565.1-565
    • /
    • 2001
  • This study aimed to compare the efficiency of propylene glycol (PG) and distilled water (DW) as vehicles that would allow diffusion of dye through the root canal system. Human maxillary central incisors were chosen and de-crowned. After enlarging the upper part of the root canal with a Peeso reamer, cementum covering the upper third of the root was removed. The roots were ultrasonically irrigated with 5% NaOCI to remove smear layer.(omitted)

  • PDF

GIS를 이용한 대기질 관리 정보 지원시스템(e-AIR) 구현( I ) (Development of Air Pollution Information System Using GIS (e-AIR))

  • 박기학;오승교
    • 환경위생공학
    • /
    • 제18권2호
    • /
    • pp.42-51
    • /
    • 2003
  • Public awareness of air pollution problem has increased the need for real time air pollution information system about changes in air pollution level. The purpose of this study is to construct e-AIR, a user-friendly air pollution information system for urban air quality using GIS(geographic information system) technology for windows. GIS was ideally suited featuring a geographical characteristics(e.g., road, traffics, buildings) and very effectively used in mapping and symbolization for the distribution of the spatial/periodic pollution status(e.g., pie or column chart, graduated symbols) which can be effectively applied to a information system on the web-site. And a user interface, GUI(graphic user interface) was designed very diversely and simply enabled the users connect with e-AIR and obtain a useful information of air quality. A interpretive technique, air pollution health index(e.g., PSI, AEI) was used also which transforms complex data on measured atmospheric pollutant concentrations into a single number or set of numbers in order to make the data more understandable. Eventually the final-step of this study was to construct e-AIR based on Web GIS could be assessed anywhere if internet is available and offer a very useful information services of the air pollution to the public like a weather news.

Comparison of Biochemical Profiles with Biogroups for the Identification of Cronobacter spp. (Enterobacter sakazakii)

  • Kim, Jung-Beom;Park, Yong-Bae;Kim, Woon-Ho;Kim, Ki-Cheol;Jeong, Hong-Rae;Kim, Dae-Hwan;Kang, Suk-Ho;Yong, Kum-Chan;Yoon, Mi-Hye;Park, Yong-Chul
    • 한국식품위생안전성학회지
    • /
    • 제24권4호
    • /
    • pp.307-311
    • /
    • 2009
  • The objectives of this study were to compare the biochemical profiles with biogroups for the identification of Cronobacter spp. (formally known as Enterobacter sakazakii) isolates using biochemical identification kits. A total of 38 Cronobacter spp. contained 5 clinical, 31 food, and 2 environmental isolates were used. All isolates were identified as Cronobacter spp. with the Vitek II system and ID 32E kit. The API 20E kit identified all isolates as Cronobacter spp. but the percentage identification was 51.1% for 16 of 38 isolates. These strains were contained to Biogroup 2, 9, 10, and 11. The utilization of inositol is a factor determining the percentage identification of Cronobacter spp. with the API 20E kit.

복부 근전도 분석을 통한 복부 비만 측정 시스템 (Measurement System of Abdominal Obesity based on Analysis of Abdominal Electromyogram)

  • 권장우;최흥호;이동훈;윤동업;홍준의
    • 재활복지공학회논문지
    • /
    • 제1권1호
    • /
    • pp.45-52
    • /
    • 2007
  • 최근 각종 질환의 원인이 되고 있는 비만은 심각한 사회문제로 대두되고 있으며, 이를 해결하기 위해 비만 관리를 위한 측정 시스템의 필요성이 증가하고 있다. 본 논문은 비만관리를 위해 복부의 근전도 신호를 분석해서 언제 어디서든 본인의 건강상태를 체크하여 적절한 의료 서비스를 받을 수 있는 측정 시스템에 관한 연구이다. 복부 근전도 선호 분석을 위해서 에너지 검출, 신호 특징 추출, 상태 분류 및 인식 등을 위한 알고리즘을 제안한다. 이 신호 분석 알고리즘을 측정 시스템에 적용하여 복부의 비만도 및 복부의 근력을 평가하여 건강상태에 대한 적절한 평가를 제공하는 시스템을 제안한다.

  • PDF

Review and Evaluation of Hand-Arm Coordinate Systems for Measuring Vibration Exposure, Biodynamic Responses, and Hand Forces

  • Dong, Ren G.;Sinsel, Erik W.;Welcome, Daniel E.;Warren, Christopher;Xu, Xueyan S.;McDowell, Thomas W.;Wu, John Z.
    • Safety and Health at Work
    • /
    • 제6권3호
    • /
    • pp.159-173
    • /
    • 2015
  • The hand coordinate systems for measuring vibration exposures and biodynamic responses have been standardized, but they are not actually used in many studies. This contradicts the purpose of the standardization. The objectives of this study were to identify the major sources of this problem, and to help define or identify better coordinate systems for the standardization. This study systematically reviewed the principles and definition methods, and evaluated typical hand coordinate systems. This study confirms that, as accelerometers remain the major technology for vibration measurement, it is reasonable to standardize two types of coordinate systems: a tool-based basicentric (BC) system and an anatomically based biodynamic (BD) system. However, these coordinate systems are not well defined in the current standard. Definition of the standard BC system is confusing, and it can be interpreted differently; as a result, it has been inconsistently applied in various standards and studies. The standard hand BD system is defined using the orientation of the third metacarpal bone. It is neither convenient nor defined based on important biological or biodynamic features. This explains why it is rarely used in practice. To resolve these inconsistencies and deficiencies, we proposed a revised method for defining the realistic handle BC system and an alternative method for defining the hand BD system. A fingertip-based BD system for measuring the principal grip force is also proposed based on an important feature of the grip force confirmed in this study.

전북지역 양돈장에서의 돼지 부종병 항체 및 톡신 양성률 조사 (Prevalence of antibody and toxin against edema disease from pig farms in Jeonbuk province)

  • 조선영;유정희;유영주;이한준;허진
    • 한국동물위생학회지
    • /
    • 제46권4호
    • /
    • pp.325-334
    • /
    • 2023
  • Edema disease (ED) in pigs is enterotoxemia caused by Shiga toxin type 2e (Stx2e)-producing Escherichia coli (STEC) and frequently occurs in young piglets. Therefore, ED causes enormous economic losses in pig farms. In this study, a modified Stx2e (mStx2e) antigen was expressed and purified using commercial E. coli expression system. Monoclonal antibody was serviced by Ynto Ab Inc., using Phage Display Technique. Anti-Stx2e antibodies in piglets were measured by indirect ELISA using mStx2e antigens. Naive Stx2e in piglets were detected by Sandwich ELISA using Stx2e-monoclonal antibodies and commercial Stx2e-polyclonal antibodies. Among 3,480 piglets, anti-Stx2e antibodies were observed in 2,573 piglets. The 49.4% among 830 piglet serum samples possessed 0.625 ㎍/mL or more of Stx2e proteins. The 18.3% of 830 sera had 0.313 ㎍/mL of Stx2e proteins. The 32.3% of 830 samples held 0.156 ㎍/mL or less of Stx2e proteins. These results show that indirect ELISA using mStx2e antigen and Sandwich ELISA using Stx2e-monoclonal and polyclonal antibodies can be useful to detect ED in piglets.

식이 Vitamin E가 Streptozotocin 유발 당뇨쥐 신장조직에서의 Microsomal Mixed Function Oxidase System에 미치는 영향 (Effects of Vitamin E on the Microsomal Mixed Function Oxidase System of Kidney in Streptozotocin-induced Diabetic Rats)

  • 신주영
    • Journal of Nutrition and Health
    • /
    • 제33권6호
    • /
    • pp.619-624
    • /
    • 2000
  • The purpose of this study was to investigate the effects of vitamin E on microsomal mixed function oxidase system of kidney in streptozotocin(STZ) induced diabetic rats. Sprague-Dawley male rats weighing 140$\pm$10g were randomly assigned to one control and three STZ-diabetic groups which were subdivided into vitamin E free diet(DM-0E group) 40mg vitamin E per kg diet(DM-40E group) and 400mg vitamin E per kg diet(DM-400E group). Vitamin E level of normal group was 40 mg per kg diet. Diabetes was experimentally induced by intravenous administration of 55 mg/kg B.W of STZ in citrate buffer(pH4.3) after 4 weeks feeding of experimental diets. Animals were sacrificed at the 6th day of diabetic state. The contents of cytochrome P450 in kidney were increased by 82, 54, 41% in DM-0E, DM-40E and DM-400E groups respectively when compared with normal group. The contents of cytochrome b5 in kidney were increased by 28% in DM-0E when compared with normal group but those of DM-40E and DM-400E groups were similar to that of normal group. The activities of NADPH-cytochrome P450 reductase in kidney that were increased by 35% in DM-0E group. Levels of TBARS(thiobarbituric acid reactive substance) in kidney were increased by 207, 129% and 72% in DM-0E and DM-400E groups respectively when compared with normal group but those of DM-40E and DM-400E groups were 26,44% lower than that of DM-0E groups. It is know that the activities of MFO system and lipid peroxidation were inhibited in kidney of STZ-induced diabetic rat by administeration of high doses of vitamin E.(Korean J Nutrition 33(6) : 619~624, 2000)

  • PDF

공정안전향상을 위한 Safety Integrity Level의 적용 방향 (Towards the Application of Safety Integrity Level for Improving Process Safety)

  • 권혁면;박희철;천영우;박진형
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.