• 제목/요약/키워드: dynamic seismic analysis

검색결과 1,388건 처리시간 0.027초

원거리와 근거리 지진파의 특성을 고려한 항만 컨테이너 크레인의 지진취약도 분석 (Seismic Fragility Analysis of Container Crane Considering Far-Fault and Near-Fault Ground Motion Characteristics)

  • 박주현;민지영;이종한
    • 한국지진공학회논문집
    • /
    • 제27권2호
    • /
    • pp.83-90
    • /
    • 2023
  • The recent increase in earthquake activities has highlighted the importance of seismic performance evaluation for civil infrastructures. In particular, the container crane essential to maintaining the national logistics system with port operation requires an exact evaluation of its seismic response. Thus, this study aims to assess the seismic vulnerability of container cranes considering their seismic characteristics. The seismic response of the container crane should account for the structural members' yielding and buckling, as well as the crane wheel's uplifting derailment in operation. The crane's yielding and buckling limit states were defined using the stress of crane members based on the load and displacement curve obtained from nonlinear static analysis. The derailment limit state was based on the height of the rail, and nonlinear dynamic analysis was performed to obtain the seismic fragility curves considering defined limit states and seismic characteristics. The yield and derailment probabilities of the crane in the near-fault ground motion were approximately 1.5 to 4.7 and 2.8 to 6.8 times higher, respectively, than those in the far-fault ground motion.

Response of non-structural components mounted on irregular RC buildings: comparison between FE and EC8 predictions

  • Aldeka, Ayad B.;Chan, Andrew H.C.;Dirar, Samir
    • Earthquakes and Structures
    • /
    • 제6권4호
    • /
    • pp.351-373
    • /
    • 2014
  • This paper investigates the seismic response of lightweight acceleration-sensitive non-structural components (NSCs) mounted on irregular reinforced concrete (RC) primary structures (P-structures) using non-linear dynamic finite element (FE) analysis. The aim of this paper is to study the influence of NSC to P-structure vibration period ratio, peak ground acceleration, NSC to P-structure height ratio, and P-structure torsional behaviour on the seismic response of the NSCs. Representative constitutive models were used to simulate the behaviour of the RC P-structures. The NSCs were modelled as vertical cantilevers fixed at their bases with masses on the free ends and varying lengths so as to match the frequencies of the P-structures. Full dynamic interaction is considered between the NSCs and P-structures. A set of 21 natural and artificial earthquake records were used to evaluate the seismic response of the NSCs. The numerical results indicate that the behaviour of the NSCs is significantly influenced by the investigated parameters. Comparison between the FE results and Eurocode (EC8) predictions suggests that EC8 underestimates the response of NSCs mounted on the flexible sides of irregular RC P-structures when the fundamental periods and heights of the NSCs match those of the P-structures. The perceived cause of this discrepancy is that EC8 does not take into account the amplification in the dynamic response of NSCs induced by the torsional behaviour of RC P-structures.

Investigation of dynamic P-Δ effect on ductility factor

  • Han, Sang Whan;Kwon, Oh-Sung;Lee, Li-Hyung
    • Structural Engineering and Mechanics
    • /
    • 제12권3호
    • /
    • pp.249-266
    • /
    • 2001
  • Current seismic design provisions allow structures to deform into inelastic range during design level earthquakes since the chance to meet such event is quite rare. For this purpose, design base shear is defined in current seismic design provisions as the value of elastic seismic shear force divided by strength reduction factor, R (${\geq}1$). Strength reduction factor generally consists of four different factors, which can account for ductility capacity, overstrength, damping, and redundancy inherent in structures respectively. In this study, R factor is assumed to account for only the ductility rather than overstrength, damping, and redundancy. The R factor considering ductility is called "ductility factor" ($R_{\mu}$). This study proposes ductility factor with correction factor, C, which can account for dynamic P-${\Delta}$ effect. Correction factor, C is established as the functional form since it requires computational efforts and time for calculating this factor. From the statistical study using the results of nonlinear dynamic analysis for 40 earthquake ground motions (EQGM) it is shown that the dependence of C factor on structural period is weak, whereas C factor is strongly dependant on the change of ductility ratio and stability coefficient. To propose the functional form of C factor statistical study is carried out using 79,920 nonlinear dynamic analysis results for different combination of parameters and 40 EQGM.

Seismic response of smart nanocomposite cylindrical shell conveying fluid flow using HDQ-Newmark methods

  • Zamani, Abbas;Kolahchi, Reza;Bidgoli, Mahmood Rabani
    • Computers and Concrete
    • /
    • 제20권6호
    • /
    • pp.671-682
    • /
    • 2017
  • In this research, seismic response of pipes is examined by applying nanotechnology and piezoelectric materials. For this purpose, a pipe is considered which is reinforced by carbon nanotubes (CNTs) and covered with a piezoelectric layer. The structure is subjected to the dynamic loads caused by earthquake and the governing equations of the system are derived using mathematical model via cylindrical shell element and Mindlin theory. Navier-Stokes equation is employed to calculate the force due to the fluid in the pipe. Mori-Tanaka approach is used to estimate the equivalent material properties of the nanocomposite and to consider the effect of the CNTs agglomeration on the scismic response of the structure. Moreover, the dynamic displacement of the structure is extracted using harmonic differential quadrature method (HDQM) and Newmark method. The main goal of this research is the analysis of the seismic response using piezoelectric layer and nanotechnology. The results indicate that reinforcing the pipeline by CNTs leads to a reduction in the displacement of the structure during an earthquake. Also the negative voltage applied to the piezoelectric layer reduces the dynamic displacement.

Seismic response analysis of reinforced concrete frames including soil flexibility

  • Jayalekshmi, B.R.;Poojary, V.G. Deepthi;Venkataramana, Katta;Shivashankar, R.
    • Structural Engineering and Mechanics
    • /
    • 제48권1호
    • /
    • pp.1-16
    • /
    • 2013
  • The seismic response of RC space frame structures with isolated footing resting on a shallow soil stratum on rock is presented in this paper. Homogeneous soil stratum of different stiffness in the very soft to stiff range is considered. Soil, footing and super structure are considered to be the parts of an integral system. A finite element model of the integrated system is developed and subjected to scaled acceleration time histories recorded during two different real earthquakes. Dynamic analysis is performed using mode superposition method of transient analysis. A parametric study is conducted to investigate the effect of flexibility of soil in the dynamic behaviour of low-rise building frames. The time histories and Fourier spectra of roof displacement, base shear and structural response quantities of the space frame on compliant base are presented and compared with the fixed base condition. Results indicate that the incorporation of soil flexibility is required for the realistic estimate of structural seismic response especially for single storey structures resting on very soft soil.

지진파 탁월주기를 고려한 비구조요소의 수평설계지진력 평가 (A Study on Evaluation of Horizontal Force of Non-structural Components Considering Predominant Periods of Seismic Waves)

  • 오상훈;김주찬
    • 한국지진공학회논문집
    • /
    • 제24권6호
    • /
    • pp.267-275
    • /
    • 2020
  • In the event of an earthquake, non-structural components require seismic performance to ensure evacuation routes and to protect lives from falling non-structural components. Accordingly, the seismic design code proposes horizontal force for the design and evaluation of non-structural components. Ground motion observed on each floor is affected by a building's eigen vibration mode. Therefore, the earthquake damage of non-structural components is determined by the characteristics of the non-structural component system and the vibration characteristics of the building. Floor response spectra in the seismic design code are estimated through time history analysis using seismic waves. However, it is difficult to use floor response spectra as a design criterion because of user-specific uncertainties of time history analysis. In addition, considering the response characteristics of high-rise buildings to long-period ground motions, the safety factor of the proposed horizontal force may be low. Therefore, this study carried out the horizontal force review proposed in the seismic design code through dynamic analysis and evaluated the floor response of seismic waves considering buildings and predominant periods of seismic waves.

지진에 대한 지반-구조물 상호작용의 확률론적 연구 (A Probabilistic Analysis of Soil- Structure Interaction Subjected to Seismic Loading)

  • 이인모;김용진;이정학
    • 한국지반공학회지:지반
    • /
    • 제6권2호
    • /
    • pp.5-20
    • /
    • 1990
  • 지반-구조물의 동적 상호작용 해석에 있어서, 흙의 특성치들 뿐만 아니라 입력지진 자체도 무척 Random하다. 본 논문에서는 이 Randomness를 고려하기 위하여 확률론적 방법을 적용하여 상호작용 해석에 미치는 영향을 연구하였다. 이 확률론적 적용을 위해 Elastic Half Space 이론에 의해 얻어진 Complex Response 방법, Random Vibration Theory와 Rosenblueth의 Two Point Estimate 방법을 사용하여 해석을 수행하여 다음과 같은 결론을 얻었다. 1) 흙의 동적 특성치 뿐만 아니라 Kanai-Tajimi에 의하여 제안된 입력지진의 PSD Function 의 불확정성도 상당히 큼을 알 수 있었다. 이때의 Parameter의 변동계수는 0.4에서 0.6의 범위를 갖는다. 2) 흙의 동적 특성치의 불확정성의 영향이 입력지진의 그것보다는 구조물에 미치는 영향이 큼 을 알 수 있었다. 3) 입력지진과 흙의 동적 특성치 사이의 상관계수에 의한 영향은 무척 작음을 알 수 있었다.

  • PDF

역량스펙트럼 및 에너지분석을 이용한 RC교각의 내진성능평가에 관한 연구 (Seismic Performance Evaluation of RC Bridge Piers using Capacity Spectrum and Energy Analysis)

  • 정영수;박종협
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2001년도 춘계학술대회 논문집
    • /
    • pp.361-367
    • /
    • 2001
  • This research aims at evaluating the seismic performance of the R/C bridge piers, which were seismically designed in accordance with the seismic provision of limited ductile behavior of Eurocode 8. Pseudo dynamic test for six(6) circular RC bridge piers has been carried out so at to investigate their seismic performance subjected to experted artificial earthquake motions. The objective of this experimental study is to investigate the hysteretic behavior of reinforced concrete bridge piers. Important test parameters are confinement steel ratio, input ground motion, etc. The seismic behavior of circular concrete piers under artificial ground motions has been evaluated through displacement ductility, energy analysis, capacity spectrum. It can be concluded that RC bridge piers designed in the seismic code of limited ductile behavior of Eurocode 8 have been determined to show good seismic performance even under expected artificial earthquakes in moderate seismicity region.

  • PDF

4-클립 체결방식을 갖는 모듈러 하우스의 내진성능평가 (Seismic performance evaluations of modular house having 4-clip fastening method)

  • 임현진;조창근;신정강;이선주
    • 한국공간구조학회논문집
    • /
    • 제22권3호
    • /
    • pp.41-48
    • /
    • 2022
  • The purpose of this study is to evaluate seismic performances of a modular house system developed by a simple 4-clip fastening method and double metal assembly made of lightweight metals. In order to evaluate structural and non-structural seismic performances of the system. Shaking table test was carried out with full-scale modular units, and a nonlinear pushover analysis was performed to obtain suitable seismic responses for story drifts, displacements, force resistances and dynamic properties of the system. Through 3D analysis and shaking table test, the current method of lightweight modular metal unit assembly and systems with seismic performance of a 4-clip fastening type modular house were demonstrated safe and effective to seismic design.

IEEE Std 693-1997을 적용한 전력용 변압기 내진 해석 (Seismic Qualification Analysis for the Power Transformer with IEEE Std 693-1997)

  • 양재철;노효철;김호영;박균수
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제54권12호
    • /
    • pp.527-531
    • /
    • 2005
  • Because of increasing demand for safety of the power transformer, the seismic qualification process in accordance with the standard of IEEE Std 693-1997 is essentially required by customer. Dynamic analysis method and static analysis method were used to qualify the seismic withstanding of the power transformer at high seismic level. Maximum stress was detected at the connection between the main structure and appendages, and maximum displacement was detected at the point of appendage's end tip. Load path and substructure system can be considered as important elements to prevent over stress and over displacement.