• 제목/요약/키워드: dynamic membrane

검색결과 299건 처리시간 0.023초

Fatigue Analysis of LNG Cargo Containment System Connections in Membrane LNG Carrier

  • Park, Jun-Bum
    • Journal of Advanced Research in Ocean Engineering
    • /
    • 제3권3호
    • /
    • pp.112-124
    • /
    • 2017
  • As an LNG carrier preserves and transports liquefied natural gas under minus $163^{\circ}C$, the cargo tank has to have sufficient hull strength against not only the wave loads but also against loads caused by loading and unloading and thermal expansion to keep the LNG safely. The main insulation types for a CCS are No.96 and Mark III from GTT for the membrane LNG carrier. Particularly, the invar membrane plate in No.96 is very thin and its connections could experience high local stresses owing to such dynamic loads. Therefore, it should be verified whether those connections have sufficient fatigue lives for the purpose of operation and maintenance. This research aims at performing fatigue analysis with 0.1 fatigue damage criteria for 40 years of design life to support new membrane CCS development using proper S-N curves and the associated finite element modeling technique for each connection and then propose a reasonable design methodology.

이온교환막 연료전지용 막 가습기의 운전 조건에 따른 성능 실험 (Performance Test of Proton Exchange Membrane Fuel Cell with the Variation of Operation Condition)

  • 배호준;김용모;이영덕;유상석
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.6-9
    • /
    • 2008
  • The efficiency and life time of the proton exchange membrane (PEM) fuel cell system is critically changed with its humidity which should be maintained properly during dynamic operation. Membrane humidifier is required to regulate proper humidity level for the design point of the PEMFC system. In this study, we presented the performance of the cylindrical membrane humidifier which is operated as water-to-gas. Dry air pressure, liquid water flow temperature, and air flow rate were chosen as the operating parameters. Humidity level is expressed with dew point.

  • PDF

SOLUTION CHARACTERISTICS AND MEMBRANE FORMATION OF PARTIALLY IMIDIZED POLY (AMIC ACID)

  • Lee, Hyuck-Jai;Won, Jong-Ok;Park, Hyun-Chae;Lee, Hoo-Sung;Kang, Yong-Soo
    • 한국막학회:학술대회논문집
    • /
    • 한국막학회 1999년도 The 7th Summer Workshop of the Membrane Society of Korea
    • /
    • pp.83-86
    • /
    • 1999
  • The imidization effect of a poly (amic acid) dope solution on membrane formation has been investigated. Poly (amic acid) solution in S-methyl-2-pyrrolidione hs been thermally imidized at $120^{\circ}C$ with different curing time and its degree of imidization was determined by infrared spectroscopy. The solution properties have been studied as a function of concentration and curing time by dynamic light scattering. The quality of a solvent was changed from good to poor with increasing imidization of poly(amic acid).The reduced polymer-solvent interaction diminishes the membrane formation time. The morphology of a membrane was able to be controlled by the characteristics of dope solution.

  • PDF

Pontoon and Membrane Breakwater

  • 기성태
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.185-191
    • /
    • 2003
  • A numerical study on the hydrodynamic properties of a floating flexible breakwater consisting of triple vertical porous membrane structures attached to a floating rigid pontoon restrained by moorings is carried out in the context of two-dimensional linear wave-flexible body interaction theory. The tensions in the triple membranes are achieved by hanging a clump weight from its lower ends. The clump weight is also restrained properly by moorings. The dynamic behavior of the breakwater was described through an appropriate Green function, and the fluid multi-domains are incorporated into the boundary integral equation. Numerical results are presented which illustrate the effects of the various wave and structural parameters on the efficiency of the breakwater as a barrier to wave action. It is found that the wave reflection and transmission properties of the structures depends strongly on the membrane length taking major fraction of water column, the magnitude of tensions on membrane achieving by the clump weight, proper mooring types and stiffness, the permeability on the membrane dissipating wave energy.

  • PDF

Effects of EPS on membrane fouling in a hybrid membrane bioreactor for municipal wastewater treatment

  • Zhang, Aining;Liu, Zhe;Chen, Yiping;Kuschk, Peter;Liu, Yongjun
    • Membrane and Water Treatment
    • /
    • 제5권1호
    • /
    • pp.1-14
    • /
    • 2014
  • A pilot-scale hybrid membrane bioreactor (HMBR) for real municipal wastewater treatment was developed by adding biofilm carriers into a conventional membrane bioreactor, distribution and dynamic changes of the extracellular polymeric substances (EPS) and their roles in membrane fouling were investigated. The results showed that the concentrations of loosely bond EPS (LB-EPS) and tightly bond EPS (TB-EPS) in activated sludge, carrier biofilm and sludge cake layer have been increased significantly with the running time of HMBR, during operation of the HMBR, EPS demonstrated positive correlations with membrane fouling. Compared to TB-EPS, LB-EPS showed more significant correlations with sludge physical properties and specific resistance to filtration (SRF) in HMBR, and thus demonstrated that LP-EPS have a stronger potential of fouling than TB-EPS. It was also found that a lower organic loading in HMBR could result a significant increase in EPS concentration, which would in turn influence membrane fouling in HMBR. This critical investigation would contribute towards a better understanding of the behavior, composition and fouling potential of EPS in HMBR operation.

Resonance and Response of the Submerged Dual Buoy/Porous-Membrane Breakwaters in Oblique Seas

  • Kee, S.T.
    • 한국해양공학회지
    • /
    • 제15권2호
    • /
    • pp.22-32
    • /
    • 2001
  • The numerical investigation of obliquely incident wave interactions with fully submerged dual buoy/porous-membrane floating breakwaters placed in parallel with spacing is studied based on linear potential theory and Darcy's law. The numerical solutions are obtained by using a discrete-membrane dynamic model and second-kind modified Bessel function distribution over the entire boundaries of fluid regions. First, numerical solutions for an idealized dual submerged system without buoys are obtained. Second, a more practical dual submerged system with membrane tension provided by buoys at its tops is investigated by the multi-domain boundary element method particularly devised for dual buoy/porous-membrane problems with gaps. The velocity potentials of wave motion are coupled with porous-membrane deformation, and solved simultaneously since the boundary condition on porous-membrane is not known in advance. The effects of varying permeability on membranes and wave characteristics are discussed for the optimum design parameters of systems previously studied. The inclusion of permeability on membrane eliminates the resonances that aggravate the breakwater performance. The system is highly efficient when waves generated by the buoys and membranes were mutually canceled and its energy at resonance frequency dissipates through fine pores on membranes.

  • PDF

Experimental determination of liquid entry pressure (LEP) in vacuum membrane distillation for oily wastewaters

  • Racz, Gabor;Kerker, Steffen;Schmitz, Oliver;Schnabel, Benjamin;Kovacs, Zoltan;Vatai, Gyula;Ebrahimi, Mehrdad;Czermak, Peter
    • Membrane and Water Treatment
    • /
    • 제6권3호
    • /
    • pp.237-249
    • /
    • 2015
  • In this study we investigate a laboratory scale vacuum membrane distillation system to produce pure water from model oil in water emulsion. Experimental determination of liquid entry pressure (LEP) of a commercial Durapore$^{TM}$ GVPH flat sheet membrane using model emulsions in various oil concentrations has been carried out. Two different methods of liquid entry pressure determination - a frequently used, so-called static and a novel dynamic method - have been investigated. In case of static method, LEP value was found to be 2.3 bar. No significant effect of oil content on LEP was detected up to 3200 ppm. In contrast, LEP values determined with dynamic method showed strong dependence on the oil concentration of the feed and decreased from 2.0 bar to a spontaneous wetting at 0.2 bar in the range 0-250 ppm, respectively. Vacuum membrane distillation tests were also performed. The separation performance is evaluated in terms of flux behavior, total organic carbon removal and droplet size distribution of the feed and final retentate. No significant effect of oil content on the flux was found ($5.05{\pm}0.31kgm^{-2}h^{-1}$) up to 250 ppm, where a spontaneous wetting occurred. High separation performance was achieved along with the increasing oil concentration between 93.4-97.0%.

멤브레인형 LNG선 화물창 단열시스템의 수면낙하 내충격 응답해석 -I : 검증을 통한 수치해석 기법 개발- (Wet Drop Impact Response Analysis of CCS in Membrane Type LNG Carriers -I : Development of Numerical Simulation Analysis Technique through Validation-)

  • 이상갑;황정오;김화수
    • 대한조선학회논문집
    • /
    • 제45권6호
    • /
    • pp.726-734
    • /
    • 2008
  • While the structural safety assessment of Cargo Containment System(CCS) in membrane type LNG carriers has to be carried out in consideration of sloshing impact pressure, it is very difficult to figure out its dynamic response behaviors due to its very complex structural arrangements/materials and complicated phenomena of sloshing impact loading. For the development of its original technique, it is necessary to understand the characteristics of dynamic response behavior of CCS structure under sloshing impact pressure. In this study, for the exact understanding of dynamic response behavior of CCS structure in membrane Mark III type LNG carriers under sloshing impact pressure, its wet drop impact response analyses were carried out by using Fluid-Structure Interaction(FSI) analysis technique of LS-DYNA code, and were also validated through a series of wet drop experiments for the enhancement of more accurate shock response analysis technique. It might be thought that the structural response behaviors of impact response analysis, such as impact pressure impulses and resulted strain time histories, generally showed very good agreement with experimental ones with very appropriate use of FSI analysis technique of LS-DYNA code, finite element modeling and material properties of CCS structure, finite element modeling and equation of state(EOS) of fluid domain.

동적 상분리법을 이용한 이방성 도토리형상 입자 제조 (Anisotropic Acorn-like Particle Fabrication Via a Dynamic Phase Separation Method)

  • 박철호;백일현
    • 멤브레인
    • /
    • 제29권1호
    • /
    • pp.61-65
    • /
    • 2019
  • 이방성 입자는 독특한 물리적 특성 때문에 다양한 분야에서 발표되고 있다. 여기서, 이방성 도토리구조 나노 입자를 제조하기 위해 새로운 동적 상분리 방법이 도입된다. 동적 상분리 방법은 용제 증발 및 무용제에 의한 침전으로 구성된다. 하부층은 비용매 희석제로서 물을 공급함으로써 제어되며, 상부층의 상분리는 휘발성 용매의 확산 및 증발에 의존한다. 이 상태에서, 도토리 형 입자가 제조되었다. 물이 채워진 밀폐된 상자(자발적 상분리)하에서, 단분산 폴리스틸렌 입자가 합성되었다. 동적 상분리와 자발적 상분리가 공존할 때, 캡과 입자의 크기가 변경되었다. 또한, 폴리스틸렌 용액의 부피는 입자 형상에 영향을 미친다. 독특한 구조가 다양한 응용 분야에 활용될 수 있기 때문에 멤브레인 기반의 제어된 물 공급과 같은 첨단 기술이 개발되면 단분산의 도토리와 같은 입자가 제조될 수 있을 것이다.

단백질 흡착성을 갖는 막 크로마토그래피용 재생 셀룰로오스 기반 음이온 교환 다공성 분리막의 제조 (Preparation of Protein Adsorptive Anion Exchange Membrane Based on Porous Regenerated Cellulose Support for Membrane Chromatography Application)

  • 서정현;이홍태;김태경;조영훈;오택근;박호식
    • 멤브레인
    • /
    • 제32권5호
    • /
    • pp.348-356
    • /
    • 2022
  • 바이오산업의 발전으로 의약품, 식품 등의 생산 과정의 분리/정제 공정에 사용되어 왔던 기존의 컬럼 크로마토그래피를 대체하여 더 높은 처리효율을 갖는 막 크로마토그래피가 부상하고 있다. 본 연구에서는 서로 다른 기공 크기의 두 가지 상용 셀룰로오스 아세테이트(Cellulose acetate, CA) 분리막을 탈아세틸화 과정을 통해, 리간드의 개질이 용이한 다공성 재생 셀룰로오스 지지체를(Regenerated cellulose, RC) 제조하였다. 음이온 교환능을 부여하고자 grafting을 수행하였으며, 구체적으로는 UV 중합법을 통해 4차 암모늄을 포함하는 음이온 교환 리간드(MAPTAC)를 부착하여 음이온 교환용 흡착막을 제조하였다. 단백질 흡착 용량은 정적 흡착 용량(Static binding capacity, SBC)시험을 통해 총 단백질 흡착 용량을 측정했고, 동적 흡착 용량(Dynamic binding capacity, DBC)을 측정하여 상용막과 비교 평가하였다. 성능 평가 결과 단백질 흡착량은 넓은 표면적에 의해 리간드 밀도가 높은, 기공 크기가 작은 순서로 높게 측정되었고, 상용 CA분리막을 탈아세틸화하고 리간드를 부착시킨 분리막(RC 0.8 + MAPTAC 43.69 mg/ml, RC 3.0 + MAPTAC 36.33 mg/ml)이 상용 막 크로마토그래피 제품(28.38 mg/ml) 대비 높은 흡착 용량을 보였다.