• 제목/요약/키워드: dynamic field test

검색결과 558건 처리시간 0.037초

현장 불평형 응답을 이용한 로터-베어링 시스템의 매개변수 규명연구 (A Study on Identifying Dynamic Characteristic Parameters of Rotor Bearing Systems Using Field Measurement Data of Unbalance Responses)

  • 이동환;김영일;박노길
    • 연구논문집
    • /
    • 통권29호
    • /
    • pp.101-109
    • /
    • 1999
  • Presented in this paper is a new method of identifying the critical speed of rotor-bearing systems without actually reaching at the critical speed itself. Using the method, it is not only possible to calculate the critical speed by measuring a series of rotor responses at much lower rotating speeds away from and without reaching at the critical speeds but also the damping ratio and eccentricity of the system can be identified at the same time. Two types of test rotors were tested on the Rotor Dynamics Test Facility at the Rotordyn-amics Lab, KIMM, and the theory has been confirmed experimentally. The method can be adopted to monitor changes of the dynamic characteristics of critical rotating machinery before and after overhauls, repairs, exchanges of various parts, or to detect trends of direction of subtle changes in the dynamic characteristic parameters over a long periods of time.

  • PDF

현장 불평형 응답을 이용한 로터-베어링 시스템의 매개변수 규명 연구 (A Study on Identifying Dynamic Characteristic Parameters of Rotor Bearing Systems Using Field Measurement Data of Unbalance Responses)

  • 이동환;김영일;박노길
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.605-611
    • /
    • 2000
  • Presented in this paper is a new method of identifying the critical speed of rotor-bearing systems without actually reaching at the critical speed itself. Using the method, it is not only possible to calculate the critical speed by measuring a series of rotor responses at much lower rotating speeds away from and without reaching at the critical speeds but also the damping ratio and eccentricity of the system can be identified at the same time. Two types of test rotors were tested on the Rotor Dynamics Test Facility at the Rotordynamics Lab., KIMM, and the theory has been confirmed experimentally. The method can be adopted to monitor changes of the dynamic characteristics of critical rotating machinery before and after overhauls, repairs, exchanges of various parts, or to detect trends of direction of subtle changes in the dynamic characteristic parameters over a long periods of time.

  • PDF

도시형자기부상열차 주행하중에 의한 단경간 PSC-Box 거더교의 동적 거동 (Dynamic Behavior of Simple Span PSC-BOX Girder Bridge under the Passage of the Urban Maglev Transit)

  • 양태석;정원용;이기열
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.864-869
    • /
    • 2008
  • Magnetic Levitated(Maglev) Vehicle, which utilizes electromagnetic forces between dual-pole electromagnets and a steel rail, generally runs on guideway structures. A prototype of an Urban Maglev Vehicle has been developed and tested in Korea, This study was conducted as a cooperation research subject of the 3-1 subject, performance improvement of maglev track structures, of the Center for Urban Maglev Program, statred in 2006. As the Maglev load is distributed rather than concentrated, a field test was conducted on Simple Span PSC-BOX Girder Bridge(L=25.0m) of the Expo-Maglev test track in Daejeon to examine the dynamic effect of the Maglev load on the bridge. Numerical analyses were also performed up to the maximum passing speed of 110 km/h by 10 km/h increments of Maglev Vehicle using Finite Element model of bridge, and girder deflections, accelerations and Dynamic Amplification Factor (DAF) are analysed.

  • PDF

Structural evaluation of an existing steel natatorium by FEM and dynamic measurement

  • Liu, Wei;Gao, Wei-Cheng;Sun, Yi;Yu, Yan-Lei
    • Structural Engineering and Mechanics
    • /
    • 제31권5호
    • /
    • pp.507-526
    • /
    • 2009
  • Based on numerical and experimental methods, a systematic structural evaluation of a steel natatorium in service was carried out in detail in this paper. Planning of inspection tasks was proposed firstly according to some national codes in China in order to obtain the economic and reliable results. The field visual inspections and static computation were conducted in turn under in-service environmental conditions. Further a three-dimensional finite element model was developed according to its factual geometry properties obtained from the field inspection. An analytical modal analysis was performed to provide the analytical modal properties. The field vibration tests on the natatorium were conducted and then two different system identification methods were used to obtain the dynamic characteristics of the natatorium. A good correlation was achieved in results obtained from the two system identification methods and the finite element method (FEM). The numerical and experimental results demonstrated that the main structure of the natatorium in its present status is safe and it still satisfies the demand of the national codes in China. But the roof system such as purlines and skeletons must be removed and rebuilt completely. Moreover the system identification results showed that field vibration test is sufficient to identify the reliable dynamic properties of the natatorium. The constructive suggestion on structural evaluation of the natatorium is that periodic assessment work must be maintained to ensure the natatorium's safety in the future.

지능형 공정제어 시스템 적용을 위한 ER 작동기의 진동제어 특성에 관한 연구 (Study on the Vibration Control Characteristics of ER Actuator for Application in Intelligence Process Control Systems(PLC))

  • 장성철
    • 한국기계가공학회지
    • /
    • 제4권1호
    • /
    • pp.49-55
    • /
    • 2005
  • This paper presents experiments on the evaluation of characteristics of ER fluids used for vibration control of application in intelligence type process control systems. Dynamic characteristics of the actuator(beam) embedded with the ER fluid can be controlled by changing the strength of the electric field applied on the ER fluids, thus provides a mean to avoid the resonance. In case electric field is supplied to the smart structure with ER fluids, vibration energy is dissipated more than the beam without electric field, because particles in ER fluid form a chain structure in the presence of electric field. The damping and stiffness of the beam with ER fluid are increased when the applied electric field increases. The characteristics of damping and stiffness of the ER fluid with various electric field strength were investigated by conducting a vibration test of the beam with ER fluid. If it applies characteristics of the ER fluids, it will be able to apply in the PLC control system for the vibration which occurs from process system.

  • PDF

소형동적콘관입시험을 이용한 전단강도 산정 및 N-Nc 상관관계 연구 (Study on Shear Strength Using a Portable Dynamic Cone Penetration Test and Relationship between N-Nc)

  • 김혁호;임희대
    • 자원환경지질
    • /
    • 제50권2호
    • /
    • pp.145-157
    • /
    • 2017
  • 최근 집중강우로 인하여 전국적으로 산사태 및 사면붕괴 현상이 빈번히 발생하고 있다. 이러한 산지 및 비탈면에서 발생하는 자연재해에 대한 대책안 마련 및 설계 입력자료로서 지반의 강도정수(전단강도)를 도출해야만 한다. 그러나 현재 산지 및 비탈면에 접근하여 지반조사를 하기 위해서는 과다한 산림훼손과 많은 경제적인 비용 등이 요구되어진다. 따라서 본 연구에서는 현장에서 인력운반이 가능한 경량화된 소형동적콘관입시험기를 제작하여 다수의 지역에 대한 지반의 특성 및 강도정수를 산출하였다. 그리고 국내 및 외국의 소형동적콘관입시험 방법에 대해서 연구 분석하여 국내에 적합한 콘 재료와 시험방법을 제안하였으며, 대표적인 지역을 대상으로 현장에서 콘관입시험 Nc값과 표준관입시험 N값과 비교 분석하였다. 이와 더불어 직접전단시험 및 공내전단시험을 실시하여 토층심도별, 기반암별, 흙의 분류별 그리고 #200번체 통과량별로 Nc값과 전단강도와의 상관관계를 분석하였다. 특히 본 연구에서는 산지조건에서 가장 많이 분포하는 사질토를 대상으로 Nc값에 대응하는 전단강도(점착력 및 내부마찰각)와의 상관식을 제안하여 산지 토층에 대한 효율적인 지반강도정수를 산출하도록 하였다.

검증된 고속철도 차량의 20량편성 정밀모형에 의한 철도교량의 동적응답 분석 (Verified 20-car Model of High-speed Train for Dynamic Response Analysis of Railway Bridges)

  • 김상효;김병석;허진영;최성락
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.485-492
    • /
    • 2001
  • The dynamic analysis model is developed with the high-speed train (KTX) and a 2-span continuous prestressed concrete box girder bridge with a double track. The analytical results are compared with the dynamic field test results and found to be valid to yield quite accurate dynamic responses. The various trainset models with different number of cars are developed and compared with the results of the regular 20-car trainset model. It is concluded that the reduced trainset models, such as 7-car and 10-car models, cannot exactly produce the dynamic responses of bridges, especially when the train speed is high. Under the coincidence condition of two trains traveling with resonance velocity in the opposite directions, it is found that the impact factor under two-way coincidence is three times larger than that under one-way traffic. Consequently, for the bridge with a double-track it is necessary to check not only the dynamic responses of the bridge with one-way traffic but those with two-way coincidence.

  • PDF

Evaluating damage scale model of concrete materials using test data

  • Mohammed, Tesfaye A.;Parvin, Azadeh
    • Advances in concrete construction
    • /
    • 제1권4호
    • /
    • pp.289-304
    • /
    • 2013
  • A reliable concrete constitutive material model is critical for an accurate numerical analysis simulation of reinforced concrete structures under extreme dynamic loadings including impact or blast. However, the formulation of concrete material model is challenging and entails numerous input parameters that must be obtained through experimentation. This paper presents a damage scale analytical model to characterize concrete material for its pre- and post-peak behavior. To formulate the damage scale model, statistical regression and finite element analysis models were developed leveraging twenty existing experimental data sets on concrete compressive strength. Subsequently, the proposed damage scale analytical model was implemented in the finite element analysis simulation of a reinforced concrete pier subjected to vehicle impact loading and the response were compared to available field test data to validate its accuracy. Field test and FEA results were in good agreement. The proposed analytical model was able to reliably predict the concrete behavior including its post-peak softening in the descending branch of the stress-strain curve. The proposed model also resulted in drastic reduction of number of input parameters required for LS-DYNA concrete material models.

철도교량 구조형식별 감쇠비 하한값 산정을 위한 시험적 연구 (Experimental Evaluation for Damping Ratio Limit of Railway Bridge according to Structure Types)

  • 민낙기;성덕룡;박용걸
    • 한국철도학회논문집
    • /
    • 제15권2호
    • /
    • pp.154-161
    • /
    • 2012
  • 철도교량 동적 설계 및 동적 안전성을 해석적으로 평가하기 위해서는 교량의 감쇠비를 산정하는 것이 매우 중요하다. 본 연구에서는 국내 고속 및 일반철도에서 일반적으로 사용되고 있는 소수주형강합성교, PSC Box, Steel Box, PSC, IPC, Precom, Preflex에 대하여 실내 모형실험 및 운행 중 현장계측을 하였다. 이러한 고속 및 일반철도의 대표적 교량형식에 대한 실내외 시험을 통해 대수감소율을 적용하여 감쇠비를 분석하였다. 따라서 철도교량의 감쇠비는 하중크기, 가진주파수, 진폭에 영향을 받지 않는 것으로 분석되었다. 또한, 기존 철도설계기준에 제시된 감쇠비 하한치와 비교하여 PSC구조 및 강합성구조 철도교량의 경우 감쇠비 하한값을 1.0%로 적용하는 것이 합리적이라 판단되었다.

트랙터-트레일러형 차량 시스템의 주행 충격진동 특성에 관한 연구 (A study on the shock & vibration characteristics of a tractor-trailer type vehicle system running on the road)

  • 김종길
    • 한국군사과학기술학회지
    • /
    • 제4권1호
    • /
    • pp.13-19
    • /
    • 2001
  • It is known that displacements, velocities and accelerations of the tractor- trailer type vehicle system in shock & vibration analysis by the flexible-multi-body dynamics including the flexibility of structure are bigger and more repetitive than them by the rigid-multi-body dynamics, and it is necessary to prove above results by the experimental field test. Therefore, in this paper, theoretical analysis by the flexible-multi-body dynamics and experimental field test for a tractor-trailer type vehicle system are conducted and their results are compared with each other. Because of unexpected metal contact and impact in the air coupler part in the field test, some accelerations measured from the experimental field test are bigger than them analyzed from the theoretical analysis, but most accelerations are well coincide with each other in the amplitudes and trends. Thus more refined dynamic analytical models for some special type vehicle systems will be possible in the future.

  • PDF