• 제목/요약/키워드: dynamic failure

검색결과 945건 처리시간 0.027초

Configuration assessment of MR dampers for structural control using performance-based passive control strategies

  • Wani, Zubair R.;Tantray, Manzoor A.;Iqbal, Javed;Farsangi, Ehsan Noroozinejad
    • Structural Monitoring and Maintenance
    • /
    • 제8권4호
    • /
    • pp.329-344
    • /
    • 2021
  • The use of structural control devices to minimize structural response to seismic/dynamic excitations has attracted increased attention in recent years. The use of magnetorheological (MR) dampers as a control device have captured the attention of researchers in this field due to its flexibility, adaptability, easy control, and low power requirement compared to other control devices. However, little attention has been paid to the effect of configuration and number of dampers installed in a structure on responses reduction. This study assesses the control of a five-story structure using one and two MR dampers at different stories to determine the optimal damper positions and configurations based on performance indices. This paper also addresses the fail-safe current value to be applied to the MR damper at each floor in the event of feedback or control failure. The model is mathematically simulated in SIMULINK/MATLAB environment. Linear control strategies for current at 0 A, 0.5 A, 1 A, 1.5 A, 2 A, and 2.5 A are implemented for MR dampers, and the response of the structure to these control strategies for different configurations of dampers is compared with the uncontrolled structure. Based on the performance indices, it was concluded that the dampers should be positioned starting from the ground floor, then the 2nd floor followed by 1st and rest of the floors sequentially. The failsafe value of current for MR dampers located in lower floors (G+1) should be kept at a higher value compared to dampers at top floors for effective passive control of multi-story structures.

The effect of fiber reinforcement on behavior of Concrete-Filled Steel Tube Section (CFST) under transverse impact: Experimentally and numerically

  • Yaman, Zeynep
    • Structural Engineering and Mechanics
    • /
    • 제82권2호
    • /
    • pp.173-189
    • /
    • 2022
  • This study presents an experimental and numerically study about the effects of fiber reinforcement ratio on the behavior of concrete-filled steel tubes (CFST) under dynamic impact loading. In literature have examined the behavior of GFRP and FRP wrapped strengthened CFST elements impact loads. However, since the direction of potential impact force isn't too exact, there is always the probability of not being matched the impact force of the area where the reinforced. Therefore, instead of the fiber textile wrapping method which strengthens only a particular area of CFST element, we used fiber-added concrete-filled elements which allow strengthening the whole element. Thus, the effect of fiber-addition in concrete on the behavior of CFST elements under impact loads was examined. To do so, six simply supported CFST beams were constructed with none fiber, 2% fiber and 10% fiber reinforcement ratio on the concrete part of the CFST beam. CFST beams were examined under two different impact loads (75 kg and 225 kg). The impactors hit the beam from a 2000 mm free fall during the experimental study. Numerical models of the specimens were created using ABAQUS finite element software and validated with experimental data. The obtained results such as; mid-span displacement, acceleration, failure modes and energies from experimental and numerical studies were compared and discussed. Furthermore, the Von Misses stress distribution of the CFST beams with different ratio of fiber reinforcements were investigated numerically. To sum up, there is an optimum amount limit of the fiber reinforcement on CFST beams. Up to this limit, the fiber reinforcement increases the structural performances of the beam, beyond that limit the fiber reinforcement decreases the performances of the CFST beam under transverse impact loadings.

초고성능 강섬유 보강 콘크리트 물성 반영을 위한 소성 기반 콘크리트 CSC 모델 보정기법 (A Calibration Method of the CSC Model for Considering Material Properties of Ultra-high Performance Concrete)

  • 박강규;이민주;김성욱;신현섭;문재흠
    • 한국건설순환자원학회논문집
    • /
    • 제10권4호
    • /
    • pp.402-410
    • /
    • 2022
  • 본 연구에서는 초고성능 강섬유 보강 콘크리트(UHPC)의 재료특성을 고려하기 위해 해석프로그램 LS-DYNA에 있는 CSC모델의 입력상수값 보정기법을 제안하였다. 1축 압축, 3축 압축, 압력-체적 변형률 곡선, 동적증가계수 등 이전 재료단위 실험 연구결과를 기반으로 입력상수값 보정을 수행하였다. 단일요소 해석결과를 실험결과와 비교하여 보정기법의 검증을 수행하였다. 또한, 유한요소모델을 구축하고 충격 및 폭발해석을 수행하여 UHPC 구조물 해석 수행 시 보정된 CSC 모델의 적용 가능성을 확인해보았다.

Seismic behavior of liquid storage tanks with 2D and 3D base isolation systems

  • Kilic, Samet;Akbas, Bulent;Shen, Jay;Paolacci, Fabrizio
    • Structural Engineering and Mechanics
    • /
    • 제83권5호
    • /
    • pp.627-644
    • /
    • 2022
  • In past major earthquakes (1994 Northridge, 1995 Kobe, Chi-Chi 1999, Kocaeli 1999), significant damages occurred in the liquid storage tanks. The basic failure patterns were observed to be the buckling of the tank wall and uplift of the anchorage system. The damages in the industrial facilities and nuclear power plants have caused the spread of toxic substances to the environment and significant fires. Seismic isolation can be used in liquid storage tanks to decouple the structure and decrease the structural demand in the superstructure in case of ground shaking. Previous studies on the use of seismic isolation systems on liquid storage tanks show that an isolation system reduces the impulsive response but might slightly increase the convective one. There is still a lack of understanding of the seismic response of seismically isolated liquid storage tanks considering the fluid-structure interaction. In this study, one broad tank, one medium tank, and one slender tank are selected and designed. Two- and three-dimensional elastomeric bearings are used as seismic isolation systems. The seismic performance of the tanks is then investigated through nonlinear dynamic time-history analyses. The effectiveness of each seismic isolation system on tanks' performance was investigated. Isolator tension forces, modal analysis results, hydrodynamic stresses, strains, sloshing heights and base shear forces of the tanks are compared. The results show that the total base shear is lower in 3D-isolators compared to 2D-isolators. Even though the tank wall stresses, and strains are slightly higher in 3D-isolators, they are more efficient to prevent the tension problem.

Development of dynamics simulation model for 3-point hitch of agricultural tractor during plow tillage

  • Mo A Son;Seung Yun Baek;Seung Min Baek;Hyeon Ho Jeon;Ryu Gap Lim;Yong Joo Kim
    • 농업과학연구
    • /
    • 제49권4호
    • /
    • pp.937-948
    • /
    • 2022
  • Agricultural operations are performed in uneven environments by attaching an implement on the 3-point hitch of a tractor. A high load is thus placed on the 3-point hitch, and fatigue and failure of the hitch may occur during agricultural operations. In this study, a dynamic simulation model was developed to predict the load occurring on the eyebolt of a 3-point hitch, which is the main damaged component. The simulation model was developed and validated using agricultural data as simulation input and validation data. The dynamics model was developed using the specifications of a 78 kW class tractor. A measurement system was constructed to measure the simulation input and validation data. The simulation model was validated using a traction load on an eye bolt, which was measured during plow tillage operation. The measurement results showed that the average traction load on the left and right lower link and the top link were 8,099.97, 4,943.06, and 636.11 N, respectively. The simulation results and the measured traction load on the left eyebolt were respectively 610.30 and 597.15 N. The simulation results and measured traction load on the left eyebolt were respectively 1,179.78, and 1,145.06 N. The error between the simulation and measurement data was roughly 2% on the left eyebolt and 3% on the right eyebolt.

Enhancing Shoulder External Rotator Electromyography Activity During Sitting External Rotation Exercise: The Impact of Biofeedback Training

  • Il-young Yu;Min-joo Ko;Jae-seop Oh
    • 한국전문물리치료학회지
    • /
    • 제30권3호
    • /
    • pp.237-244
    • /
    • 2023
  • Background: The external rotation (ER) exercise in performed at a 90° abduction of the shoulder joint is an effective to strengthen the infraspinatus. However, failure of the humeral head to control axial rotation during exercise can be increased the posterior deltoid over activity. Biofeedback training is an effective method of promoting motor learning and control it could look forward to activate the infraspinatus selectively by controlling the humeral head during exercise. Objects: The aim of this study was investigated that whether biofeedback for axial rotation was effective to activate selectively the infraspinatus during ER exercise. Methods: The 15 healthy males participated, and all subjects performed both ER exercise in a sitting position with shoulder abducted 90° under conditions with and without axial rotation biofeedback. Exercise was performed in a range of 90° ER, divided into three phases: concentric, isometric, and eccentric. The infraspinatus and posterior deltoid muscle activity were observed using surface electromyography. Results: Both infraspinatus activity (p < 0.01) and infraspinatus to posterior deltoid activity ratio (p = 0.01) were significantly higher with biofeedback however, posterior deltoid activity was significantly lower with biofeedback (p = 0.01). The infraspinatus muscle activity and muscle activity ratio were the highest in the isometric contraction type, and there were significant differences for all contraction types (p < 0.05). Whereas, the posterior deltoid activity was the lowest in the isometric contraction type, and showed a significant difference between isometric and other two contraction types (p < 0.05), but no significant different between concentric and eccentric contraction. Conclusion: Our results indicate that the axial rotation biofeedback during sitting ER exercise might be effective method to activating selective infraspinatus muscle and recommended to enhance the dynamic stability of the shoulder joint.

폐타이어 분말을 이용한 혼합경량토의 역학적 특성 연구 (Mechanical Properties of Waste Tire Powder - Added Lightweight Soil)

  • 김윤태;강효섭
    • 대한토목학회논문집
    • /
    • 제28권4C호
    • /
    • pp.247-253
    • /
    • 2008
  • 본 연구에서는 준설토, 폐타이어 분말 및 저회(bottom ash)를 재활용한 폐타이어 분말 혼합경량토의 역학적 특성을 고찰하였다. 본 실험에서 폐타이어 분말의 함량은 건조 준설토 중량대비 0%에서 100%까지 25%간격으로 변화시켜 5개의 공시체를 준비하였다. 혼합된 공시체는 일축압축시험, 탄성파 시험을 수행하여 강도와 지반정수들을 구하였다. 실험결과 폐타이어 함량이 증가함에 따라 일축압축강도와 단위중량은 감소하는 경향을 나타내었다. 그러나 파괴시 축변형률은 증가하는 것으로 나타났다. 또한 폐타이어 분말의 함량이 증가할수록 폐타이어 혼합경량토의 응력-변형률 곡선은 취성적 거동보다는 연성적 거동을 나타내었다. 탄성파 시험에서는 폐타이어 함량이 증가함에 따라 탄성파 속도와 전단탄성계수는 감소하는 성질을 나타내고 있다.

환경하중을 고려한 콘크리트 포장 피로모형의 개발 (Development of Fatigue Model of Concrete Pavement Considering Environmental Loading)

  • 임진선;김연복;정진훈
    • 대한토목학회논문집
    • /
    • 제28권6D호
    • /
    • pp.819-829
    • /
    • 2008
  • 콘크리트 포장에 반복적으로 재하되는 차량의 하중에 의하여 슬래브의 동적강도는 꾸준히 감소하며 장기적으로 피로균열이 발생한다. 온도와 수분의 분포에 의하여 슬래브 내에는 항상 응력이 도입되어 있으므로 이를 고려한 후 차량하중의 영향을 추가해야만 보다 정확하게 콘크리트 포장의 피로수명을 예측할 수 있다. 따라서, 본 연구에서는 기존에 개발된 대표적 피로모형들의 각종 인자들을 평가하고 모형으로부터 데이터를 추출하여 환경하중을 고려하는 새로운 피로모형을 개발하였다. 국내 각 지역의 기상 및 교통조건을 사용하여 국내에서 일반적으로 시공되는 콘크리트 포장에 대한 피로해석을 수행하여 개발된 피로모형의 적용성을 평가하였다. 슬래브 하부에서 발생한 상향의 균열보다는 슬래브 상부의 인장응력에 의한 하향의 균열이 피로파손의 주요한 원인으로 판단되었다. 본 연구결과를 바탕으로 한 후속 연구를 통하여 차량의 속도가 고려된 피로해석도 수행될 수 있을 것으로 기대된다.

Seismic response evaluation of 154 kV transformer porcelain bushing by shaking table tests

  • Chun, Nakhyun;Jeon, Bubgyu;Kim, Sungwan;Chang, Sungjin;Son, Suwon
    • Structural Engineering and Mechanics
    • /
    • 제84권2호
    • /
    • pp.155-165
    • /
    • 2022
  • The use of electricity and communication between electronic devices is increasing daily, which makes the stability of electrical power supply vital. Since the 1990s, large earthquakes have occurred frequently causing considerable direct damage to electrical power facilities as well as secondary damage, such as difficulty in restoring functions due to the interruption of electric power supply. Therefore, it is very important to establish measures to protect electrical power facilities, such as transformers and switchboards, from earthquakes. In this study, a 154 kV transformer whose service life had expired was installed on the base fabricated by simulating the field conditions and conducting the shaking table tests. The dynamic characteristics and seismic behavior of the 154 kV transformer were analyzed through the resonance frequency search test and seismic simulation test that considers the front, rear, left, and right directions. Since the purpose of this study is to analyze the acceleration amplification in the bushing due to the acceleration amplification, the experimental results were analyzed focusing on the acceleration response and the converted acceleration amplification ratio rather than the failure due to the displacement response of the transformer. The seismic force amplification at the transformer bushing was evaluated by simulating the characteristics of electrical power facilities in South Korea, and compared with the IEC TS 61463 acceleration amplification factor. Finally, the amplification factor at zero period acceleration (ZPA) modified for each return period was summarized. The results of this study can be used as data to define the amplification factor at ZPA of the transformer bushing, simulating the characteristics of electrical power facilities in Korea.

Updates on the Immune Cell Basis of Hepatic Ischemia-Reperfusion Injury

  • Mi Jeong Heo;Ji Ho Suh;Kyle L. Poulsen;Cynthia Ju;Kang Ho Kim
    • Molecules and Cells
    • /
    • 제46권9호
    • /
    • pp.527-534
    • /
    • 2023
  • Liver ischemia-reperfusion injury (IRI) is the main cause of organ dysfunction and failure after liver surgeries including organ transplantation. The mechanism of liver IRI is complex and numerous signals are involved but cellular metabolic disturbances, oxidative stress, and inflammation are considered the major contributors to liver IRI. In addition, the activation of inflammatory signals exacerbates liver IRI by recruiting macrophages, dendritic cells, and neutrophils, and activating NK cells, NKT cells, and cytotoxic T cells. Technological advances enable us to understand the role of specific immune cells during liver IRI. Accordingly, therapeutic strategies to prevent or treat liver IRI have been proposed but no definitive and effective therapies exist yet. This review summarizes the current update on the immune cell functions and discusses therapeutic potentials in liver IRI. A better understanding of this complex and highly dynamic process may allow for the development of innovative therapeutic approaches and optimize patient outcomes.