• Title/Summary/Keyword: dynamic factor

Search Result 2,077, Processing Time 0.026 seconds

An Experimental Study on the Dynamic Characteristics of Damping Flexible Coupling( II ) (유체감쇠 커플링의 동특성에 관한 실험적 연구(II))

  • 김종수;제양규;정재현;전효중
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.1
    • /
    • pp.23-31
    • /
    • 1994
  • The present works are the experimental results of the study to develope a damping flexible coupling which has a high performance of control for the torsional vibrations of power shafts in a large machinery. The damping flexible coupling is manufactured and is compared for dynamic characteristics with other type coupling which is the Geislinger coupling. The static coefficient of stiffness and the damping coefficient allows the control of excitation frequency through a cam driver. The experimental results obtained from the two couplings are compared with the theoretically results.

  • PDF

The study on the dynamic characteristics of steel structure system for vibration estimation in hospital building (철골조 고층 병원건물의 진동예측을 위한 동적특성 및 설계인자에 관한 연구)

  • Jang, Kang-Seok;Kim, Young-Chan;Ahn, Sang-Kyung;Na, Woon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.458-461
    • /
    • 2008
  • The primary objective of this study is to provide simple analytical tools to estimate dynamic characteristics of steel framed floor system in hospital building for vibration serviceability due to human activities, bogie, medical equipment. and so on. In order to evaluate the dynamic characteristics and vibration levels according to steel framed floor system, we had executed impact test and measurement on steel structure floor system in various hospital buildings. But perhaps most importantly, how to make the most of deduced design factor for design of hospital building. therefore we presented the access method such as the three-dimensional F.E. numerical analysis on the basis of the design drawing, and the properties of all floors for estimation of vibration level in hospital building.

  • PDF

Static and Dynamic Testing Technique of Inductor Short Turn

  • Piyarat, W.;Tipsuwanporn, V.;Tarasantisuk, C.;Kummool, S.;Im, T.Sum
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1999.10a
    • /
    • pp.281-283
    • /
    • 1999
  • This topic presents an inductor short turn testing. From the rudimentary principles, the quality factor(Q) decreases due to inductor short turn. Frequency response varies because of the variation of circuit inductance and resistance. In general, short turn circuit testing is performed by comparing the ratio of an inductance and resistance of inductor in that particular circuit. An alternative method can be done by considering the response of second order circuit which can give both dynamic and static testing, whereas static testing give an error results not more than 2 turns. For dynamic testing, the result is more accurate, which can test fur the short turn number form 1 turn onward.

  • PDF

Dynamic Analysis of Metal Transfer using VOF Method in GMAW (II) - Short Circuit Transfer Mode - (VOF 방법을 이용한 GMA 용접의 금속 이행에 관한 동적 해석 (II) - 단락 이행 모드의 해석 -)

  • 최상균;고성훈;유중돈;김희진
    • Journal of Welding and Joining
    • /
    • v.15 no.3
    • /
    • pp.47-55
    • /
    • 1997
  • Dynamic characteristics of the short circuit mode are investigated using the Volume of Fluid (VOF) method. When the initial molten drop volume, contact area and wire feed rate are given, rate change of the molten bridge profiles, pressure and velocity distributions are predicted. The electromagnetic force with proper boundary conditions are included in the formulation to consider the effects of welding current. It is found that the molten metal is transferred to the weld pool mainly due to the pressure difference caused by the curvatures in the initial stage, and electromagnetic force becomes dominant factor in the final stage of short circuit transfer. Necking occurs at the contact position between the molten drop and weld pool, and the initial molten drop volume and welding current have significant effects on break-up time.

  • PDF

Setting and Hardening of Portland Cement Mortar Investigated with Wave Reflection Factor (WRF를 이용한 모르터의 응결 및 경화 예측)

  • ;Thomas , Voigt;Surendra P. Shah
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.834-839
    • /
    • 2003
  • Previous research has been conducted on an ultrasonic wave reflection method that utilizes a steel plate embedded in the concrete to measure the reflection loss of shear waves at the steel-concrete interface. The reflection loss has been shown to have a linear relationship to compressive strength at early ages. The presented investigations continue this research by examining the fundamental relationship between the reflection loss, measured with shear waves, and the hydration kinetics of Portland cement mortar, represented by dynamic elastic moduli, compressive strength and degree of hydration. Dynamic elastic moduli are measured by fundamental resonant frequency and degree of hydration is determined by thermogravimetric analysis. The water/cement ratio was varied for the tested mixture compositions. The results presented herein show that compressive strength, dynamic shear modulus and degree of hydration have a linear relationship to the reflection loss for the tested mortars at early ages.

  • PDF

Dynamic analysis of steel frames with semi-rigid connections

  • Zohra, Djouaher Fatma;Nacer, Ihaddoudene Touati Abd
    • Structural Engineering and Mechanics
    • /
    • v.65 no.3
    • /
    • pp.327-334
    • /
    • 2018
  • In the steel structures design, beam-to-column connections are usually considered either rigid or pinned, while their actual behavior lies between these two ideal cases. This consideration has a major influence on the results of the local and the global behavior of steel structures. This influence is noticed in the case of a static analysis, and has an important effect in the case of a dynamic analysis. In fact, pinned and rigid nodes can be considered as two specific cases of a semi-rigid behavior. To study the efficiency of the classification adopted in Eurocode 3, a numerical simulation of semi-rigid nodes has been carried out using the software ANSYS. In the aim to validate this simulation, the numerical results are compared to those of an analytical approach. After that, the validated numerical simulation has been used, to evaluate the efficiency of the classification adopted by the Eurocode 3, regarding semi-rigid connections. Finally, a new method is proposed to define a more accurate evaluation about semi-rigid connections.

ESTIMATION OF VEHICLE STATE AND ROAD BANK ANGLE FOR DRIVER ASSISTANCE SYSTEMS

  • Chung, T.;Yi, S.;Yi, K.
    • International Journal of Automotive Technology
    • /
    • v.8 no.1
    • /
    • pp.111-117
    • /
    • 2007
  • The nonlinear characteristics of a suspension is directly related to the ride quality of a passenger car. In this study, the nonlinear characteristics of a spring and a damper of a passenger car is analyzed by dynamic experiments using the MTS single-axial testing machine. Also, a mathematical nonlinear dynamic model for the suspension is devised to estimate the ride quality using the K factor. And the effect on the variation of the parameters of the suspension is examined. The results showed that the dynamic viscosity of the oil in a damper was the parameter that most influeced the ride quality of a passenger car for the ride quality of a passenger car.

Finite Element Model Building Procedure of an External Mounting Pod for Structural Dynamic Characteristics Analysis of an Aircraft (항공기 구조 동특성 해석을 위한 외부 장착 포드의 유한요소모델 구축 절차)

  • Lee, Jong-Hak;Ryu, Gu-Hyun;Yang, Sung-Chul;Jung, Dae-Yoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2011.10a
    • /
    • pp.72-77
    • /
    • 2011
  • In this study, the natural frequencies and mode shape of an external mounting pod were verified using the modal analysis and modal testing technique for a pod mounted on an aircraft. The procedure associated with the FEM building of an external mounted pod to predict the dynamic behavior of aircraft structures is described. The simplified FEM reflecting the results of the modal testing of a pod is built through the optimization, applied to the structural dynamic model of an Aircraft, used to verified the stability of vibration and flutter of an aircraft.

  • PDF

A Study on the Structural Dynamic Design for Sub-micro Vibration Control in High Class Semiconductor Factor by Semi-Empirical Method (준 경험기법을 이용한 고집적 반도체공장의 미진동 제어를 위한 구조물의 동적설계에 관한 연구)

  • 이홍기;백재호;원영재;박해동;김두훈
    • Journal of KSNVE
    • /
    • v.9 no.6
    • /
    • pp.1227-1233
    • /
    • 1999
  • Modern technology depends on the reliability of extremely high technology equipments. In the production of semiconductor wafer, optical and electron microscopes, ion-beam, laser device must maintain their alignments within a nanometer. This equipment requires a vibration free environment to provide its proper function. Especially, lithography and inspection devices, which have sub-nanometer class high accuracy and resolution, have come to necessity for producing more improved giga and tera class semiconductor wafers. This high technology equipments require very strict environmental vibration standard, vibration criteria, in proportion to the accuracy of the manufacturing, inspecting devices. This paper deals with the structural dynamic design in high class semiconductor factory in order to be satisfied more strict vibration criteria for high sensitive equipment.

  • PDF

Vehicle Dynamic Simulation Using the Neural Network Bushing Model (인공신경망 부싱모델을 사용한 전차량 동역학 시뮬레이션)

  • 손정현;강태호;백운경
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.4
    • /
    • pp.110-118
    • /
    • 2004
  • In this paper, a blackbox approach is carried out to model the nonlinear dynamic bushing model. One-axis durability test is performed to describe the mechanical behavior of typical vehicle elastomeric components. The results of the tests are used to develop an empirical bushing model with an artificial neural network. The back propagation algorithm is used to obtain the weighting factor of the neural network. Since the output for a dynamic system depends on the histories of inputs and outputs, Narendra's algorithm of ‘NARMAX’ form is employed in the neural network bushing module. A numerical example is carried out to verify the developed bushing model.