• Title/Summary/Keyword: dusts

Search Result 300, Processing Time 0.028 seconds

Combustion Chracteristics of Biomass and Refuse Derived Fuel (바이오매스와 폐기물 고형연료의 연소특성)

  • Gu, Jae-Hoi;Oh, Sea Cheon
    • Applied Chemistry for Engineering
    • /
    • v.23 no.5
    • /
    • pp.456-461
    • /
    • 2012
  • To verify the utilization of biomass as energy, the combustion characteristic has been studied by an experimental combustion furnace under an isothermal and non-isothermal combustion. The wood pellet, rice straw and rice husk were used as biomass samples in this work. The characteristics of emission gases, dusts and residues from biomass combustion have been analyzed and compared with those of reuse derived fuel (RDF). From isothermal combustion experiments, it was found that the incomplete combustion of rice straw was greater that that of rice husk, wood pellet and RDF. This is due to the fact that the combustion reaction rate of the rice straw was faster than that of other samples, and the oxygen concentration in rice straw combustion was rapidly decreasing. It was also found that $NO_{X}$ concentration of emission gas from wood pellet combustion was the lowest. From non-isothermal combustion experiments, it was found that all samples were burned before $900^{\circ}C$. Also, the temperature range of $NO_{X}$ emission was similar to that of CO emission, on the other hand, $SO_{2}$ was emitted at a higher temperature than that of CO emission.

Monitoring of Internal Harmful Factors According to Environmental Factors in Pig Farm (양돈장 내의 환경 요인에 따른 내부 유해인자의 변동 모니터링)

  • Lee, Seong-Won;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.62 no.1
    • /
    • pp.105-115
    • /
    • 2020
  • With the decrease of the agricultural population in Korea, the workers who is vulnerable to labor are increasing in agricultural industry because of aging, feminization of population. They are exposed in poor working environment with higher temperature and concentrations of dust, gas. Higher concentration of harmful gas and dust can cause chronic and acute disease to workers depending on exposure intensity and frequency. In order to improve the working environment in the livestock facilities, It is important to secure monitoring data of the thermal environment and the concentration of harmful gases and fine dust. Multi-point measurement was performed to analyze the regional environmental conditions in the pig rooms. When analyzing the working environment, video monitoring was conducted to analyze the concentration changes of ammonia, hydrogen sulfide and fine dust according to worker movement and work type. Ammonia and hydrogen sulfide monitoring result showed 1.5~2 times higher concentrations than other work when working in the pigs living zone, and 2~4 times higher than other work when working to increase the activity of pigs. In the case of fine dust, the result was 1.3 times higher than the worker's exposure standard in a specific work. The concentrations of gases and dusts from pig farms are not of concern for acute poisoning in normal work, but there is a risk of chronic respiratory disease if they are continuously exposed. Accordingly, there is a need for development of work environment monitoring device tailored to workers and preparation of alternatives.

A Study on the Enhance of Air tightness Performance of a New Type Silding Window with horizontally Rolling Wheels (수평 구름 바퀴가 적용된 신 유형 미서기 창문의 기밀성능 개선에 관한 연구)

  • Jang, Hyok-Soo;Kim, Young-Il;Chuung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.63-70
    • /
    • 2015
  • Crevices between window and window frame cause not only heat losses but also serve path to sound transmission and infiltration of fine dusts that are harmful to humans. There were many efforts in the past to eliminate these crevices but because of the windows' indispensable function of opening and closing, it was an unsolvable problem. In this study, a new type sliding window is developed by applying horizontally rolling wheels to implement a surface sealing which is excellent for enhancing air tightness. To evaluate the feasibility of the newly developed window, forces for opening and closing, durability and air tightness were testet according to Korean Testing Standards. Force for opening a 2000 N window is 30 N. It endured 100,000 cycles of opening and closing. Infiltration was $0.00m^3/(m^2h)$ for a pressure difference of 10 Pa. Since this window has few moving parts, it has favorable features of low cost and few breakdown.

The Characteristics of the Families with Pneumoconiosis Patients (진폐환자 가족의 특성)

  • Park, Young Mi;Lee, Sung Eun
    • Korean Journal of Occupational Health Nursing
    • /
    • v.8 no.1
    • /
    • pp.84-91
    • /
    • 1999
  • Pneumoconiosis is a pathological change which is caused by coal dusts. It is a chronic disease that is not cured thoroughly but need treatment and nursing care through all lifetime of the patient. The family of the patient will be suffered from the physical and mental difficulties in the consequence of pneumoconiosis. The study is to find out the characteristics of the families with pneumoconiosis patients. The subjects of the study were 300 families with pneumoconiosis patients who were under medical treatment in Taeback, Donghae, Jeongsun Occupational Medical Center. The period of the study was from the 8th to the 31st of August, 1998. The data were collected by the structured questionnaires included the family intensity measurement which was translated by "Oh". The general properties of the subjects were calculated by frequency and percentage with SAS program. The followings are the summaries of the study. 1) The mean age of the pneumoconiosis patients was 62.3 years. The mean duration of diseases was 11 years and 7 months and the mean duration of hospital stay was 6 years and 4 months. 2) The mean age of the primary care giver was 55.7 years. The proportion of highschool education was 9.6% and it was quite low level compared to other primary care giver groups. 3) The average number of family members were 1.76 person(2.76 persons included patient). The economic status was somewhat high compared to other families with chronic patients. 4) The mean score of family intensity was 41.2(item mean=3.4). With the result, it is recommended to develop a program to improve the quality of family life. For example, there will be social support program for pneumoconiosis patients family sponsored by Social Insurance for Occupational Diseases.

  • PDF

AN ANALYSIS OF INFRARED IMAGES OF JUPITER IMPACTED BY P/SHOEMAKER-LEVY 9

  • KIM YONG HA;SUNG KIYUN;KIM SANG JOON;COCHRAN W. D.;LESTER D. F.;TRAFTON L.;CLARK B. E.
    • Journal of The Korean Astronomical Society
    • /
    • v.29 no.2
    • /
    • pp.245-253
    • /
    • 1996
  • We have analyzed infrared (IR) images of Jupiter which was observed at the McDonald Observatory, Texas, U.S.A., during the P/SHoemaker-LEvy 9 (SL9) impact period and about one week after the last impact. The IR images were obtained on the 2.7m telescope using a NICMOS array with filters to isolate the $1.5{\mu}m\;NH_3\; band,\;the\;2.3{\mu}m\;CH_4\;band,\;the\;2.12{\mu}m\;H_2\;S(0)$ pressure-induced absorption, and the continua at $1.58{\mu}m\;and\;2.0{\mu}m$ (short K-band). All images except those with the $1.58{\mu}m$ continuum filter show bright impact sites against the relatively dark Jovian disk near the impact latitude of about $45^{\circ}$ S. This implies that dusts originated from the impacts reflect the solar radiation at high altitudes before absorbed by stratospheric $CH_4,\;NH_3 \;or\;H_2$. The impact sites observed with the $2.3{\mu}m$ filter are conspicuously bright against a very dark background. The morphology of impact sites, G, L, and H at 2.3 and $2.12{\mu}m$ filters shows clearly an asymmetric structure toward the incident direction of the comet fragments, in agreement with the studies of visible impact images obtained with the Hubble Space Telescope. Comparisons of reflectances of G, L, and H sites with simple radiative transfer models suggest that optically thick dust layers were formed at high altitudes at which methane absorption attenuates incoming sunlight only by about $1\%$. The dust layers in these sites seem to form at about the same altitude regardless of the magnitude of the impacts, but they appear to descend gradually after the impacts. The dust layers have optical depths of 2-5, according to the models.

  • PDF

RETRIEVAL OF LOCAL INTERPLANETARY DUST EMISSIVITY BY ASTRO-F

  • HONG S. S.;KWON S. M.;PYO J.;UENO M.;ISHIGURO M.;USUI F.;WEINBERG J. L.
    • Journal of The Korean Astronomical Society
    • /
    • v.37 no.4
    • /
    • pp.159-169
    • /
    • 2004
  • This is a proposal to probe local part of the interplanetary dust (IPD) cloud complex and retrieve mean volume emissivity of the local IPDs at mid-infrared wavelengths. This will be done by monitoring, with Infrared Camera (IRC) aboard the ASTRO-F, the annual modulation of the zodiacal emission. In pointing mode of the ASTRO-F mission the spacecraft can make attitude maneuvering over approximately ${\pm}1^{\circ}$ range centered at solar elongation $90^{\circ}$ in the ecliptic plane. The attitude maneuvering combined with high sensitivity of the IRC will provide us with a unique opportunity observationally to take derivatives of the zodiacal emission brightness with respect to the solar elongation. From the resulting differential of the brightness over the ${\pm}1^{\circ}$ range, one can directly determine the mean volume emissivity of the local IPDs with a sufficient accuracy to de-modulate the annual emissivity variations due to the Earth's elliptical motion and the dis-alignment of the maximum IPD density plane with respect to the ecliptic. The non-zero eccentricity ($e_{\oplus}$= 0.0167) of the Earth's orbit combined with the sensitive temperature dependence of the Planck function would bring modulations of amplitude at least $3.34\%$ to the zodiacal emission brightness at mid-infrared wavelengths, with which one may determine the IPD temperature T(r) and mean number density n(r) as functions of heliocentric distance r. This will in turn fix the power-law exponent $\delta$ in the relation $T(r) = T_o(r/r_o)^{-\delta}$ for the dust temperature and v in $n(r) = n_o(r/r_o)^-v$ for the density. We discuss how one may de-couple the notorious degeneracy of cross-section, density, reference temperature $T_o$ and exponent $\delta$.

A Case of Intrapulmonary Lymph Nodes Presenting Multiple Nodules (다발성 폐결절로 나타난 폐내림프절 1예)

  • Lee, Sook-Young;Jo, Keon-Hyon;Kim, Kan-Hyoung;Moon, Hwa-Sik;Song, Jeong-Sup;Park, Sung-Hak
    • Tuberculosis and Respiratory Diseases
    • /
    • v.46 no.6
    • /
    • pp.879-883
    • /
    • 1999
  • The lymphoid system of the lung represents a complex network of lymphoid tissue and lymphatic vessels. Lymph nodes are normally located in the hila, adjacent to the lobar bronchi and within the lung to the level of the fourth-order bronchi. Clinically apparent intrapulmonary lymph nodes are rare. Although of intrapulmonary lymph node histogenesis is uncertain, They are probably hyperplastic lymphoid nodules related to inhalation of irritant dusts and attendant distortion of local lymphatic vessels. Intrapulmonary lymph nodes are detected as solitary or multiple pulmonary nodules. These nodules are difficult to differentiate from intrapulmonary metastasis by radiologic finding. We experienced a case of intrapulmonary lymph nodes presenting multiple nodules in a 46 years old man, which was confirmed by thoracoscopic biopsy.

  • PDF

Monitoring of the Fugitive and Suspended Dust Dispersion at the Reclaimed Land and Neighboring Farms: Monitoring in Gim-je (간척지 인근 농경지에서의 비산 및 부유먼지 확산 모니터링(II): 김제 모니터링)

  • Hwang, Hyun-Seob;Lee, In-Bok;Shin, Myeong-Ho;Hong, Se-Woon;Seo, Il-Hwan;Yoo, Jae-In;Bitog, Jessie.P.;Kwon, Kyeong-Seok;Kim, Yong-Hee
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.51 no.2
    • /
    • pp.59-67
    • /
    • 2009
  • A study on fugitive dusts was conducted at Saemangeum reclaimed land located in Gim-je area. The monitoring result on the fugitive and suspended dust was significantly affected by the farming activities (harvesting and land cultivation) and vehicles passing nearby the measuring points. The concentration of the fugitive dust generated from the reclaimed land was reduced remarkably by the effect of halophyte present on the ground and the tide embankment. Comparing the data collected in 2006 and 2007, the concentrations of TSP and PM10 decreased by 47.4% and 29.5%, respectively. After harvesting operations at paddy field, TSP increased by 22% while PM10 increased by 54%. The concentration of a Cl- which is a representative ion of sea-salt decreased to about 35% in 2007 compared with 2006. This represents that the inside area change and plant covering rate affected on the decrease of fugitive dust. The correlation analysis for the compounds of topsoil at each measuring point shows that near the coastline is more comparable. The canopy of halophyte in the source area also increased which reduced the fugitive dust remarkably. The dust distribution measured by dust spectrometer at the same point shows that most particles are $0.5{\mu}m$ to 2um size but not greater than $5{\mu}m$.

The Study on the Effect of Passenger Coach temperature When Aircurtains Installed At Electrical Rolling Stock At Entrance Door (전동차 출입문에 에어커튼 설치시 객실 온도 변화 연구)

  • Ahn Jong-Kon;Kim Chul-Ho;Park Duk-Sin
    • Proceedings of the KSR Conference
    • /
    • 2004.10a
    • /
    • pp.489-496
    • /
    • 2004
  • The effect of airconditioning and heating system when aircurtains installed in subway electrical rolling stock at entrance door. It blocks cold/hot air of outside. It is good for health with its blocking effect against dusts exhaust fumes, odor bugs and smoke from outside. It always maintains clean and pleasant atmosphere inside. It helps you to have health with its ever-equal temperature distribution at inside. It saves lots of maintenance cost for heating/cooling (about 86$\%$) since it cuts the loss of hot air under heating as well as of cold air under air-conditionin. Customers can feel pleasant go in and out (better than before) with the door. It is an indispensable product for the employers to cut the cost. It makes customers feel pleasant near doors, since it isnt influenced by temperature difference of cold/hot air when the door opens/closes. In electrical rolling stock passenger temperature is a lot different from that the door opens/closes. One of the main aims is to create an acceptable thermal environment without draught problem. Temperature, gradients when aircurtains installed in subway electrical rolling stock at entrance door have been studied. And the temperature measured at 0.1, 0.5, 1.3, 1.7m above the floor. It has been found that temperature, with large fluctuations caused more draught influence.

  • PDF

Explosion Hazards of Aluminum Powders with the Variation of Mean Diameter (알루미늄 분진의 평균입경 변화에 따른 폭발위험성)

  • Han, Ou-Sup;Han, In-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.18 no.4
    • /
    • pp.21-26
    • /
    • 2014
  • In this study, the explosion characteristic of aluminium powders have been investigated as a function of particle size using by a 20 L dust explosion apparatus (K$\ddot{u}$hner). The tested aluminium particle sizes were the volume mean diameter of 16, 33 and $88{\mu}m$. The lower explosion limit increases gradually with the increasing of dust particle diameter, respectively 40, 60, $125g/m^3$ in mean diameter of 16, 33 and $88{\mu}m$. Also the increase in particle size for each aluminum dusts was found to cause an decrease in explosion pressure and Kst of dust explosion index, and a increase in the lower explosion concentration. Research results may have important implications for aluminum powders utilization and safety operation.