• Title/Summary/Keyword: dust pollution

Search Result 511, Processing Time 0.031 seconds

An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel (도로터널에서 종류식 환기 시설의 운전 방안)

  • Kim, T.H.;Hwang, I.J.;Hong, D.H.;Chung, J.S.;Chung, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

A Study on Response Characteristics of Photoelectric Type Smoke Detector Chamber Due to Dust and Wind Velocity (분진 및 풍속에 따른 광전식연기감지기 챔버의 응답특성에 관한 연구)

  • Lee, Chun-Ha;Lee, Ho-Sung;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.50-57
    • /
    • 2017
  • The present article discusses the response characteristics of smoke detector chamber due to dust and wind velocity. Although situations have improved in terms of early sensing of fires as the smoke detectors are applied indoors, studies tend to place insufficient focus on the side effects and malfunction that can be caused by diversified life dust produced indoors and environmental requirements, etc. Therefore, in the present study, 4 types of photoelectric smoke detectors with different forms and structures of smoke chamber were selected as the experimental objects, and dust test was conducted with fly ash, talcum powder and fiber dust as experiment samples to study indoor applicability of the smoke detectors in terms of their response to diversified dust and wind velocity. Also, to observe response characteristics due to pollution level inside the smoke chamber, wind velocity for dust test were set additionally at 0.25 m/s, 0.5 m/s, and 1.0 m/s. Based to the experimental results, fly ash, talcum powder, and fiber dust (black hair powder) were found to be suitable at the dust test reference wind velocity conditions of 0.25 m/s for both operation test and non-operation test after dust application. On the other hand, under the harsh wind velocity conditions of 0.5 m/s and 1.0 m/s, malfunction of unwanted alarm was observed in non-operation tests in the case of fly ash and talcum powder, and non-operation was confirmed to occur in the case of fiber dust as the alarm failed to operate normally in operation tests.

Comparison of Chemical Compositions of Size-segregated Atmospheric Aerosols between Asian Dust and Non-Asian Dust Periods at Background Area of Korea

  • Kim, Won-Hyung;Song, Jung-Min;Ko, Hee-Jung;Kim, Jin Seog;Lee, Joung Hae;Kang, Chang-Hee
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.11
    • /
    • pp.3651-3656
    • /
    • 2012
  • The size-segregated atmospheric aerosols have been collected at 1100 m site of Mt. Halla in Jeju, a background area in Korea, using 8-stage cascade impact air sampler during Asian dust and non-Asian dust storm periods. Their ionic and elemental species were analyzed, in order to examine the pollution characteristics and composition change between Asian dust and non-Asian dust periods. The major ionic species such as nss-$SO_4{^{2-}}$, $NH_4{^+}$, and $K^+$ were predominantly distributed in the fine particles (below $2.1{\mu}m$ diameter), and besides the $NO_3{^-}$ was distributed more in coarse particle fraction than fine particle. On the other hand, the typical soil and marine species i.e., nss-$Ca^{2+}$, $Na^+$, $Cl^-$, and $Mg^{2+}$, were mostly existed in the coarse particles (over $2.1{\mu}m$ diameter). As well in the elemental analysis of aerosols, the major soil-originated Al, Fe, Ca, and others showed prominently high concentrations in the coarse particle fraction, whereas the anthropogenic S and Pb were relatively high in the fine particle fraction. From the comparison of aerosol compositions between Asian dust and non-Asian dust periods, the concentrations of the soil-originated species such as nss-$Ca^{2+}$, Al, Ca, Fe, Ti, Mn, Ba, Sr have increased as 2.7-4.2 times during the Asian dust periods. Meanwhile the concentrations of nss-$SO_4{^{2-}}$ and $NO_3{^-}$ have increased as 1.4 and 2.0 times, and on the contrary $NH_4{^+}$ concentrations have a little bit decreased during the Asian dust periods. Especially the concentrations of both soil-originated ionic and elemental species increased noticeably in the coarse particle mode during the dust storm periods.

Assessment of the Nitrate Radical Chemistry and Chemical Composition on Jeju Island during the Asian Pollution Period in the Spring of 2001

  • Shon, Zang-Ho;Kim, Ki-Hyun;Keith N. Bower;Lee, Gangwoong;Kim, Jiyoung
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.E3
    • /
    • pp.137-148
    • /
    • 2003
  • In this study, we examined the influence of long-range transport of dust particles and air pollutants on the photochemistry of NO$_3$on Jeju Island, Korea (33.17 N, 126.10$^{\circ}$E) during the Asian Dust-Storm (ADS) period of April 2001. Three ADS events were observed during the periods of 10∼12, 13∼14, and 25∼26 April. Average concentration level of nighttime NO$_3$on Jeju Island during the ADS period was estimated to be about 2 x 10$^{8}$ molecules cm$^{-3}$ ( - 9 pptv). Decreases in NO$_3$levels during the ADS period was likely to be determined mainly by the enhancement of the $N_2$O$_{5}$ heterogeneous reaction on dust aerosol surfaces. The reaction of N20s on aerosol surfaces was a more important sink for nighttime N03 during the ADS due to the significant loading of dust particles. The reaction of $N_2$O$_{5}$ with NMHCs and the gas-phase reaction of N20s with water vapor were both significant loss mechanisms during the study period, especially during the NADS. However, dry deposition of these oxidized nitrogen species and a heterogeneous reaction of NO$_3$were of no importance. Short-term observations of $O_3$, NO$_2$, DMS, and SO$_2$in the MBL indicated that concentrations of most of these chemical species were different between the ADS and non - Asian - Dust-Storm (NADS) periods, implying that their levels were affected sensitively by the differences in air mass trajectories.

Assessment of Photochemistry of OH and NO$_3$ at Jeju Island During Asian Dust-Storm Period of the Spring 2001

  • Shon, Zang-Ho;Keith N. Bower;Kim, Ki-Hyun;Lee, Gangwoong;Kim, Jiyoung
    • Proceedings of the Korea Air Pollution Research Association Conference
    • /
    • 2002.11a
    • /
    • pp.429-429
    • /
    • 2002
  • This study examines the influence of long-range transport of dust particles and air pollutants on photochemistry of OH and NO$_3$ at Jeju Island (33.17$^{\circ}$ N, 126.10$^{\circ}$ E) during the Asian dust-storm (ADS) period in April 2001. The atmospheric concentrations of criteria pollutants (O$_3$, NO$_2$, CO) and sulfur species were measured at a ground station on Jeju Island, Korea as part of the ACE-Asia intensive operation. Three ADS events were observed during the periods of 10-12, 13-14, and 25-26 April, respectively. The concentrations of the criteria pollutants (i.e., $O_3$, NO$_2$, and SO$_2$) were not significantly different from those during the non-Asian-dust-storm (NADS) period. Average OH and NO$_3$ levels at Jeju Island during the study period (ADS and NADS) were estimated to be 4-10 $\times$ 10$^{5}$ moleculescm$^{-3}$ and 2-4 pptv, respectively. Two main sources of OH radical were the primary production from the reaction of water vapor ($H_2O$) and O(1D) radicals and the reaction of HO$_2$ with NO. CO was a dominant sink of OH during the ADS period: whereas NO$_2$ was the most important during the NADS period. for NO$_3$ radical, a reaction of NO$_2$ with $O_3$ was the most important atmospheric source; while $N_2$O$_{5}$ uptake on dust particles was the most dominant sink during the ADS period.

  • PDF

A Study on How to Improve the Accuracy of Automatic Micro Dust Measurement Equipment (미세먼지 자동측정장비의 정확도 향상 방안 연구)

  • Cho, Min-cheol;Kim, Seung-Ho;Na, Hye-Yun;Kim, Nan-Hee;Cho, Gwang-un;Bae, Seok-Jin;Lee, Se-Haeng
    • Journal of Environmental Science International
    • /
    • v.31 no.5
    • /
    • pp.447-456
    • /
    • 2022
  • This study was conducted to propose a way to increase the accuracy and precision of 𝛽-ray measurement equipment. Statistical processing results of equivalent evaluation data from 2016 to 2021 confirmed that the concentration of micro dust measured by 𝛽-ray measurement equipment was higher than that of micro dust sampler. According to quarterly data, it was confirmed that the data from the third quarter (July to September) showed a different trend from other periods, which is assumed to be due to weather conditions. This study indicates that automatic micro-dust measurement equipment evaluation at air pollution measuring stations during the third quarter should be excluded. The evaluation cycle should be changed from once every two years to quarterly. In addition, when the criterion for determining equivalence evaluation falls within the range of the slope and intercept values of the existing trend line, it is necessary to evaluate the R2 value together and reduce the slope from 0.9-1.1 to 0.9-1.0.

Retrieval of Depolarization ratio using Sunphotometer data and Comparison with LIDAR Depolarization ratio (선포토미터 데이터를 이용한 편광소멸도 산출과 라이다 편광소멸도와의 비교)

  • Kim, Kwanchul;Choi, Sungchul;Noh, Youngmin
    • Korean Journal of Remote Sensing
    • /
    • v.32 no.2
    • /
    • pp.97-104
    • /
    • 2016
  • We present linear particle depolarization ratio at 440, 675, 870, and 1020 nm retrieved from measurements with an AERONET sun/sky radiometer at Osaka, Japan. The retrieved data were compared with lidar derived linear particle depolarization ratio at 532 nm at the same site. We find good agreement between linear particle depolarization ratios derived with Sun photometer and measured by lidar except for those at 440 nm. The coefficients of determination between lidar derived data and sun/sky radiometer derived data were 0.28, 0.81, 0.88, and 0.89 at 440, 675, 870, and 1020 nm, respectively. We find that the linear particle depolarization ratio derived with sun/sky radiometer varies by the mixing between Asian dust and pollution particles. As the mixing ratio of Asian dust and pollution particles is increased, the linear particle depolarization ratio values are lower than the values of pure Asian dust. It was confirmed by the value of single-scattering albedo and particle size distribution.

A Study of Critical Items and Related Standards on Designing for Passive Apartments (패시브 공동주택 계획을 위한 설계 중점항목 및 관련 기준 연구)

  • Lee, Myoung-Ju
    • Journal of the Architectural Institute of Korea Planning & Design
    • /
    • v.34 no.7
    • /
    • pp.21-29
    • /
    • 2018
  • This study aimed to find and suggest the purpose of future plans, critical items on designing and Related standards to amend construction standards for domestic energy saving and environmentally friendly housings. It would also activate and increase the supplies of passive house minimizing the problems on current apartment housings in winter and reducing heating energy which brings fine dust pollution. After defining the standard model of Korean apartment housings(reference model), this study calculated the amount of heating energy demand per unit area annually as applying the yearly changed standards from 2008 to 2017 to existing standard model. It turned out that applying 2017 construction standards of energy saving and eco-friendly housings to reference model has saved up to 75% of heating energy demand comparing to the one applied 2008's. However, it still could not solve the fundamental problems such as winter fungus, condensation, freezing, freeze and burst, and insulation weakness space, and could not be free from fine dust particles. To solve them, this study suggested improved standards adding critical items on design related to outside insulation, cut off the heat-bridge, enforce air-tightness and heat change efficiency on heat recovery ventilator. As a result, it has reduced more than 10% of heat demand from 2017. It would be more than 90% of savings from 2008 if we make the amount of heat loss be zero on heat bridge on designing stage in the future.

Characteristics of Cyclone and Electric Dust Collection Oil Filters for Selective Removal of Fiber Tenter Air Pollutants (섬유 텐터 대기오염물질의 선택적 제거를 위한 싸이클론 및 전기 집진 오일필터의 특성)

  • Jin Ho Jung;Seung Hwan Ryu;Soon Duk Kwon;Yoon Hyun Cho
    • Textile Coloration and Finishing
    • /
    • v.35 no.4
    • /
    • pp.256-273
    • /
    • 2023
  • Among the dyeing industries, the tenter process is a process that improves the quality of fibers by drying and ironing (heat treatment) dyed fabrics, and drugs such as water repellents, antistatic agents, and fiber softeners are mainly used in these tenter processes. These drugs are vaporized in the process of treatment by high temperatures (180 ~ 230℃), and are observed in a complex form such as white smoke, oil mist, and fine dust, causing odor. To treat the complex exhaust gas at the rear end of the tenter facility, most companies operate by installing a wet scrubber and an adsorption tower alone or in parallel, but there are many problems. In particular, the insoluble oil mist at the rear end of the tenter has significantly low processing efficiency in the cleaning dust collection facility, and there is a problem in the facility by adsorption due to the occlusion phenomenon caused by the oil mist. In addition, the odor gas at the rear end of the tenter contains a lot of aldehydes, and in order to improve these various problems, a complex exhaust purification device using cyclone and electric support collector was developed. This study examined the applicability of economical and efficient technology by removing complex air pollution at the rear end of the tenter and applying improved technology than the existing technology.

Development of diesel particulate filter for diesel locomotives (디젤기관차용 입자상물질 배출 저감필터 연구)

  • Cho, Young-Min;Kwon, Soon-Bark;Park, Duck-Shin;Jung, Woo-Sung;Lim, In-Gwon;Park, Eun-Young;Kim, Se-Young
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.994-999
    • /
    • 2007
  • The particulate matters emitted by diesel locomotives cause serious air pollution in stations and railroad. There have been various attempt to reduce the air pollution from diesel bus or trucks. However, the air pollution from the diesel locomotives has been out of control because there has not any adaptable technology. In this study, a diesel particulate filter was developed and applied to the diesel locomotives. A 3,000 horsepower large-scale locomotive and a 1,500 horsepower middle-scale locomotive were used for the test of the filter. The particulate matter emissions before and after the treatment was monitored by a scanning mobility particle sizer and a dust monitor. As a result, it was observed that the particulate matters could be successfully removed from the emission gases by using the filter.

  • PDF