• Title/Summary/Keyword: dust collector

Search Result 100, Processing Time 0.035 seconds

An Operation Methed for Longitudinal Flow Ventilation System in a Road Tunnel (도로터널에서 종류식 환기 시설의 운전 방안)

  • Kim, T.H.;Hwang, I.J.;Hong, D.H.;Chung, J.S.;Chung, J.K.
    • Proceedings of the KSME Conference
    • /
    • 2001.06b
    • /
    • pp.87-92
    • /
    • 2001
  • In automobile highway tunnels, in order to maintain a suitable environment for drivers and traffic, visibility in the tunnel must be maintained, and the concentrations of poisonous substances including carbon monoxide must be kept at or below allowable levels. For this reason, in long tunnels and tunnels with heavy traffic, ventilation facilities are installed. When the ventilation facilities are run at full capacity, the environment in the tunnel is obviously adequately maintained, but this consumes a great deal of electric power. Consequently, a central problem in highway tunnel ventilation control systems is to keep the pollution concentration at or below the allowable level, and thus provide a safe environment for traffic, while consuming as little electricity as possible. This paper introduces an operation method of longitudinal flow ventilation systems with jet-fan, dust collector and vertical ducts.

  • PDF

A Comparative Analysis of Dust Particles Collected by Cleaning Equipments in Subway Tunnel (도시철도 터널 내 청소장치별 집진먼지 비교 분석)

  • Lee, Young-Kwon;Kim, Il-Hong;Jo, Byung-Ki;Kim, Man-Hwa;Park, Jong-Heon
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.1388-1398
    • /
    • 2011
  • Air pollution in subway tunnel is primarily caused from the wear of metallic materials. As undesirable substance, PM(Particulate Matter) can especially harm the health of passengers and workers as well as clog the main parts of rolling stock such as inverters. To improve the air quality in subway tunnel, SMRT(Seoul Metropolitan Rapid Transit Corporation) has developed anti-pollution devices such as Magnetic Dust Collector, Vacuum Cleaner For Rail Road and Particulate Removing Sprinkler Vehicle. Introducing these mechanical devices, this paper is mainly devoted to explaining the characteristics of collected dust according to the result of particle-size analysis and componential analysis.

  • PDF

Development of An Operation Monitoring System for Intelligent Dust Collector By Using Multivariate Gaussian Function (Multivariate Gaussian Function을 이용한 지능형 집진기 운전상황 모니터링 시스템 개발)

  • Han, Yun-Jong;Kim, Sung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.470-472
    • /
    • 2006
  • Sensor networks are the results of convergence of very important technologies such as wireless communication and micro electromechanical systems. In recent years, sensor networks found a wide applicability in various fields such as environment and health, industry scene system monitoring, etc. A very important step for these many applications is pattern classification and recognition of data collected by sensors installed or deployed in different ways. But, pattern classification and recognition are sometimes difficult to perform. Systematic approach to pattern classification based on modem learning techniques like Multivariate Gaussian mixture models, can greatly simplify the process of developing and implementing real-time classification models. This paper proposes a new recognition system which is hierarchically composed of many sensor nodes having the capability of simple processing and wireless communication. The proposed system is able to perform context classification of sensed data using the Multivariate Gaussian function. In order to verify the usefulness of the proposed system, it was applied to intelligent dust collecting system.

  • PDF

Development of Intelligent IoT Exhaustion System for Bag Filter Collector (백필터 집진기의 지능형 IoT 탈진 시스템 개발)

  • Jang, Sung-Cheol;Lee, Jung-Won
    • Journal of Internet of Things and Convergence
    • /
    • v.5 no.1
    • /
    • pp.29-34
    • /
    • 2019
  • A bag filter collector is a kind of air purifier that organizes several or dozens of filters to purify fine dust and release clean air into the atmosphere. If the bag filter length is less than 5m, the dust and fume attached to the bag filter could be effectively removed by passing the compressed air generated by the diaphragm valve through the venturi. Injectors that are more efficient and economical are urgently needed to achieve satisfactory results for long-bag exhaustion of more than 7 meters. In the case of existing domestic and foreign injectors, a number of blow tubes were dismantled during maintenance, and the injector and blow tube were combined to pose a number of problems, including inconvenience of work due to weight increase. In this study, injector flow for the development of the best use of interpretation of the coanda effect and the fourth round of industrial technology Intelligent automation of exhaustion, have been engineered energy than standard equipment. lowering costs and filter life to radically improve the commercial studies.

Numerical Study on the Internal Flow in the Cyclone Vacuum Cleaner (사이클론 청소기 내부 유동에 관한 수치해석적 연구)

  • Lee, Chanhyun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.283-289
    • /
    • 2014
  • General household vacuum cleaners consist of dust collector, pre filter, motor and exhaust filter, and the filtered clean air is discharged to the atmosphere. By using the CFD methods, we estimated the internal flow in two types of commercial cyclone vacuum cleaners to evaluate the dust collection performance. From the analysis, it was known that the number of revolution had higher values in cyclone cone region. CFD analysis in a specific showed non-uniform velocity distribution at outlet, which results in the deterioration of particle collection performance. In order to improve flow condition, the installation of baffle was proposed and the values of velocity RMS were estimated.

Theoretical and Computation Analysis on the Pressure Drop in the Cyclone Dust Collector (사이클론 집진장치 내부의 압력강하에 대한 전산해석과 이론식의 결과 비교)

  • Hyun, Daegeun;Chang, Hyuksang
    • Clean Technology
    • /
    • v.20 no.3
    • /
    • pp.263-268
    • /
    • 2014
  • Using the CFD method, the pressure drop in 6 cyclone dust collectors of different shape were calculated. And the results were compared with results of the conventional theories. Equations of Shepherd and Lapple (1939, 1940), First (1950), Alexander (1949), Stairmand (1949), Barth (1956) were used in the theoretical calculation. In CFD calculations, we used standard k-epsilon model for analysis of turbulent flow, fluid is $25^{\circ}C$ air, the velocity at inlet is 10 m/s and the temperature is $25^{\circ}C$. In CFD analysis results, the pressure distributions along the flow showed similar patterns in different cyclone shapes. But the pressure drop distributions estimated on the conventional theories had big difference in different cyclone shapes. Only First's theory and CFD analysis showed similar results.

An Air Cleaning Efficiencies of Wet Air Cleaner in the Windowless Swine Fattening Stall in Summer (무창 비육돈사에서 습식공기정화기의 여름철 공기정화효율 분석)

  • Oh, I.H.;Lee, J.H.;Lee, K.H.;Lee, J.H.;Lee, D.S.;Eo, S.M.;Lee, M.L.
    • Journal of Animal Environmental Science
    • /
    • v.12 no.3
    • /
    • pp.133-140
    • /
    • 2006
  • The climate of stall significantly influences on animal production ability. High concentration of ammonia gas, $CO_2$ and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and farmer health, and production ability. Therefore, it is necessary to keep clean the inside air of stall to increase the productivity. An air cleaner of wet type, consisting of a fan, a motor, rotating discs, a dust collector, a water bowl, an ozone generator etc, has been developed to clean the stall air. The work principle is that the inside air is sucked through the fan, and the rotating discs make water into fineness spray and blow into the stall. The rest water flows down to the dust collector. In the present study, we measured the dust, ammonia gas, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with On-mode and Off-mode of wet air cleaners. The dust measure was divided into 3 categories, TSP, $PM_{10}$, and $PM_{2.5}$. In summer, the TSP in on-mode were maximum $0.259mg/m^3$ and minimum $0.128mg/m^3$, and the average was $0.195mg/m^3$. These are comparable to the data from Off-mode stall that maximum $0.308mg/m^3$, minimum $0.139mg/m^3$, and average $0.277mg/m^3$. However, $PM_{10}$ and $PM_{2.5}$ showed any significant differences between the tests. The concentrations of ammonia gas in Off-mode stall were maximum 13.8 ppm and minimum 5.9 ppm, and the average was 8.47 ppm. However in On-mode stall the ammonia gas concentrations were maximum 10.5 ppm and minimum 5.5 ppm, and the average was 7.63 ppm. The concentration of ammonia gas in On-mode was 10% in average lower than off-mode stall. Odor was measured by olfactometer. In the Off-mode stall, the odor unit were maximum 420 $Ou/m^3$ and minimum $300\;OU/m^3$, and the average was $367\;OU/m^3$, but in the On-mode stall the odor unit were maximum $330\;OU/m^3$ and minimum $210\;OU/m^3$, and the average was $253\;OU/m^3$. Odor removal efficiency was about 31% in On-mode stall.

  • PDF

Simultaneous Removal Characteristics of Particulate and Elemental Mercury in Convergence Particulate Collector (융합형여과집진장치에서의 먼지입자와 원소수은의 제거 성능 특성)

  • Park, Young Ok;Jeong, Ju Yeong
    • Particle and aerosol research
    • /
    • v.6 no.4
    • /
    • pp.173-183
    • /
    • 2010
  • The high temperature pleated filter bags which were used during this study were made of pleated nonwoven fabric of heat and acid resistant polysulfonate fibers which can withstand the heat up to $300^{\circ}C$ and have a filtration area which is 3 to 5 times larger than the conventional round filter bags. Cartridge module packed with 3 kind of the sulfur impregnated activated-carbon based sorbents were inserted in the inner of the pleated filter bag. This type of pleated filter bag was designed to remove not only the particulate matter but also the gaseous elemental mercury. The electrostatic precipitator part can enhance the particulate removal efficiency and reduce the pressure drop of the pleated filter bag by agglomerated particles to form a more porous dust layer on the surface of the pleated bag which is increased the filter bag cleaning efficiency. In addition, the most of particles are separated from the flue gas stream through the cyclone and the electrostatic precipitator part which were installed at the lower part and main body part of the convergence particulate collector, respectively. Thus reduce particulate loading of the high temperature pleated filter bags were applied in this study to analyze the removal characteristics of particulate matter and gaseous elemental mercury.

An experimental study on the bypass-type DPF using pneumatic cylinder systems (공압 시스템을 이용한 바이패스형 매연여과장치의 실험적 연구)

  • KIM, Sang-Am
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.54 no.1
    • /
    • pp.73-80
    • /
    • 2018
  • Intermittent duty of emergency generator has problems emitting large quantities of PM and NOx in exhaust gas. The aim of this study is to propose DPF system which can be applied to medium-large emergency generators. The system is composed of soot dust collector, silencer and filter trap, which is designed to reduce PM emissions at the emergency generator start-up. The pneumatic system controls a flow direction of exhaust gas to pass through the soot collector and filter trap until the engine reaches complete combustion condition. An experiment is performed to measure PM content and concentration to analyze the performance and characteristics of the proposed system.