• 제목/요약/키워드: dust collection efficiency

검색결과 109건 처리시간 0.024초

자동차 브레이크 미세먼지 포집을 위한 미니 사이클론의 난류모델에 따른 포집효율 변화 (Variation of Collection Efficiency with Turbulence Model in a Mini Cyclone for Collecting Automobile Brake Fine Dust)

  • 한동연;이영림
    • 한국기계가공학회지
    • /
    • 제20권3호
    • /
    • pp.47-52
    • /
    • 2021
  • Fine dust generated from vehicle brakes accounts for a significant amount of fine dust from non-exhaust system. Since such brake fine dust contains a large number of heavy metal components that are fatal to the human body, a device capable of collecting them needs to be developed. A mini cyclone, one of the devices that can effectively collect fine dust, has the advantage of relatively simple shape and high collection efficiency. Therefore, in this study, the collection efficiency of the mini-cyclone was numerically analyzed using CFD in order to find out whether such a mini-cyclone is suitable for collecting brake fine dust. As a result, the cut-off diameter was predicted to be about 1.5㎛, which means that the particle trapping load of the filter can be drastically reduced. Therefore, there is a possibility that the mini-cyclone can be used to collect fine dust from disc brakes.

루버 집진기의 성능특성 (Performance Characteristics of Louver Dust Collectors)

  • 우상희;김종범;박통일;육세진;권순박;배귀남
    • 한국입자에어로졸학회지
    • /
    • 제12권1호
    • /
    • pp.11-20
    • /
    • 2016
  • A large amount of wear dust generated during train operation is a major dust source in urban railway tunnels. To check possibility of a louver dust collector for the removal of dust in the railway tunnel, five louver dust collector models were designed and their performance was tested in a wind tunnel. JIS Z 8901 Class 8 dust was used as a test dust. Pressure drop and particle collection efficiency were evaluated with the face velocity ranging from 1 m/s to 4 m/s. At this low velocity range, particle collection efficiency of the louver dust collector was found to be insensitive to air velocity and design parameters. Pressure drop was under 40 Pa, and $PM_{10}$ and $PM_{2.5}$ collection efficiencies were approximately 50% and 30%, respectively.

이동 전극형 전기집진기의 집진특성에 관한 연구 - II. 펄스 하전 파형 및 분진농도의 영향 - (A Study on the Collection Characteristics of a Moving Electrode Electrostatic Precipitator - II. Effect of Wave Form of Pulse Energization and Dust Concentration -)

  • 김용진;하병길;정상현;홍원석;유주식
    • 설비공학논문집
    • /
    • 제16권10호
    • /
    • pp.908-913
    • /
    • 2004
  • This study investigates the effect of the wave form of pulse energization and dust concentration on the collection characteristics of a moving electrode electrostatic precipitator (MEEP). Under the same specific corona power, the collection efficiency of the MEEP for the lower dust concentration ($2g/m^3$) becomes higher than that for the higher concentration ($10g/m^3$). Both the collection efficiency and specific corona power increase with increasing pulse period for the same value of applied voltage. The collection efficiency of MEEP is higher than that of the conventional fixed plate electrode electrostatic precipitator.

보건용 마스크의 분진포집효율, 흡기저항 및 CO2 농도 (Dust Collection Efficiency, Inhalation Pressure, and CO2 Concentration in Health Masks)

  • 한돈희;김일순
    • 한국환경보건학회지
    • /
    • 제46권1호
    • /
    • pp.78-87
    • /
    • 2020
  • Objectives: To identify the degree of physical burden, a determination was undertaken of dust collection efficiency, inhalation pressure, and CO2 concentration related to health masks certified by the Ministry of Food and Drug Safety (MFDS). Methods: Twenty health masks were purchased on the market. Dust collection efficiency and inhalation pressure were determined in the same manner as in MFDS certification testing, respectively using TSI Model 8130 (TSI, U.S.) and ART Plus (Korea). CO2 concentrations for 20 subjects using a CO2 analyzer (G100, G150, Geotechnical Instrument Ltd., UK) were measured with a similar method as a total inward leakage test. In addition to CO2 levels, dead space volumes in the masks was determined for predicting concentrations of CO2 in inhalation air. Results: Most of the dust collection efficiencies found for the 20 masks were far higher than the standard. Four KF94s met KF99 and four KF80s even met KF94. Most inhalation pressures were also much lower than the standard, with many almost one-half of the standard. The mean and standard deviation of CO2 concentration in the mask were 2.9±0.44%. Considering dead volume, the prediction for CO2 concentration in the inhalation air was 4,395±1,266 ppm. Conclusions: For healthy men and women, the dust collection efficiency and inhalation pressure of health masks were not at a level that would affect their health. Although CO2 levels in the inhalation air were predicted not to affect health, research on the physiological effects of health masks on Koreans is needed for more precise research.

석회석 슬러리 입자 제거를 위한 전기집진기 포집효율 평가 (Evaluation of Collection Efficiency of Electrostatic Precipitator for Removing Limestone Slurry Particles)

  • 이기혁;김문원;류태우;육세진
    • 한국입자에어로졸학회지
    • /
    • 제15권2호
    • /
    • pp.57-65
    • /
    • 2019
  • Recently, there has been much research on the effect of fine dust on human body with increasing interest in the fine dust. Thermal power plant, which is considered as one of the main sources of fine dust, is reported to be responsible for 14% of the total amount of domestic fine dust in the Republic of Korea. Therefore, dust collecting devices in the thermal power plant need to be improved. In this study, the electrostatic precipitator (ESP) was considered to substitute for a mist eliminator used in flue gas desulfurization facility. By considering real situation in the flue gas desulfurization facility, the collection efficiency of the ESP was evaluated by using the sprayed limestone slurry particles. The collection efficiency of the ESP was higher than that of the mist eliminator, showing the possibility of replacing the mist eliminator with the ESP in flue gas desulfurization facility.

미분탄 연소 보일러용 전기집진기의 방전특성 및 집진특성에 관한 연구 (A Study on the Discharge Characteristics and the Collection Efficiency of the Electrostatic Precipitator for Pulverized Coal Boiler)

  • 이태식;손진운;남창우;이규철
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제49권10호
    • /
    • pp.570-576
    • /
    • 2000
  • The discharge and the collection efficiency characteristics of an electrostatic precipitator have been studied under various operating conditions. The specific resistivity of pulverized coal dust was about 1013∼1014[${\Omega}{\cdot}cm$] and reached the maximum value of 6${\times}$1013[${\Omega}{\cdot}cm$] at 150[$^{\circ}C$]. Back corona has been occurred as dust contents and gas temperature increase. In the case of back corona occurrence, collection effciency decreased rapidly. This problem has been solved by increasing moisture contents. Experimental results showed that collection efficiency of the full wave voltage was higher than that of the pulse wave voltage. The modification parameter k of the collection efficiency equation was about 0.42.

  • PDF

선체 표면 공사시 발생하는 분진 수거 장치 개발에 관한 연구 (A Study on the Development of Dust Collection System for Hull Repair)

  • 여석준
    • 동력기계공학회지
    • /
    • 제8권2호
    • /
    • pp.31-38
    • /
    • 2004
  • The main purpose of this study is to investigate the characteristics of hybrid collection system combined with centrifugal force of cyclone and filtration of bag filter in one unit system. The experiment and numerical simulation are executed for the analysis of collection efficiency and pressure drop characteristics of hybrid system in comparison with those of a general fabric bag filter with the various experimental parameters such as inlet velocity(filtration velocity), dust concentration and dust type, etc.. In present system, dust particles tangentially coming into the system body are controlled by the centrifugal force effect, and the next collection is made out by the filtration mechanism in the fabric filter media. Therefore, the effective first collection causes the decrease of dust loading on the fabric filter, and it presents quite a lower pressure drop of fabric filter than that of a general fabric filter. At the inlet velocity, $21{\sim}27m/sec$ and inlet concentration(fly ash) $300mg/m^3$, pressure drops through the filter media of hybrid system are shown lower as $10{\sim}22mmH_2O$ comparing to those($17{\sim}33mmH_2O$) of a general fabric bag filter.

  • PDF

환기장치와 필터를 활용한 미세먼지 제거특성 조사 (Characterization of Fine Dust Collection Using a Filter Ventilation)

  • 전태영;김재용
    • 공업화학
    • /
    • 제26권2호
    • /
    • pp.229-233
    • /
    • 2015
  • 본 연구에서는 폐암을 유발하는 발암물질이며 다양한 문제의 원인이 되고 있는 유해물질인 미세먼지 제거특성을 조사하였다. 변수로는 습도, 초기미세먼지 주입량, 유속을 고려하였다. 실험결과 습도가 높은 경우 제거에 소요되는 시간동안 평균 농도는 낮아지지만, 최종농도에는 큰 차이가 없었다. 세 가지 초기미세먼지주입량의 변화는 모두 비슷한 제거경향을 나타내었다. 또한 유속이 0.6 m/s에서 0.3 m/s로 변할 경우 제거소요시간이 약 1.4배 증가하는 결과가 관찰되었다. 본 연구에서는 습도, 미세먼지 주입량, 유속 중 미세먼지 제거에 가장 큰 변화를 보이는 것은 유속으로 관찰되었다.

습식 배연탈황설비용 습분제거기 포집효율 평가 (Collection Efficiency of a Mist Eliminator for Wet Flue Gas Desulfurization)

  • 김문원;육세진;류태우
    • 한국입자에어로졸학회지
    • /
    • 제14권3호
    • /
    • pp.73-80
    • /
    • 2018
  • Recently, there has been much research on the effect of ultrafine dust on human body with increasing interest in the ultrafine dust. In the Republic of Korea, there are many old thermal power plants, and the amount of ultrafine dust emitted from the thermal power plants is reported to be about 14% of the total amount of domestic fine dust. Therefore, the amount of fine dust from the flue gas desulfurization facility in the thermal power plant needs be reduced. In this study, we made an experimental setup to simulate a flue gas desulfurization facility and analyzed the physical characteristics of the particles passing through a mist eliminator. Experiments were carried out to investigate the collection efficiency of the mist eliminator by using the Arizona Test Dust in a dry environment, and then spraying limestone slurry into the flue gas desulfurization system equipped with the mist eliminator to examine the size and morphology of limestone particles upstream and downstream of the mist eliminator. Cut-off size of the mist eliminator was formed at about $6{\mu}m$. The result of this study is expected to be helpful for designing an electrostatic precipitator for removing particles passing through the mist eliminator.

전기 집진기의 집진 효율 향상에 관한 연구 (The Improvement of Collection Efficiency of Electrostatic Precipitator)

  • 안국찬;김봉환;이광석
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.25-30
    • /
    • 2002
  • This paper demonstrates the effects of dust electrical resistivity on electrostatic precipitability. The effects of gas temperature, velocity and humidity on the collection efficency were considered by used of coal fly ashes from fluidized bed combustion boiler. The experiments for collection efficiency were carried out in the pilot plant. The ashes which have non-spherical geometry and high electrical resistivity were used. Electrical resistivity is an important property for the collection efficiency in the electrostatic precipitators. Fly ash resistivity as a function of temperature up $350{\circ}C$ and water concentration(up to 15%) has been experimentally investigated using the resistivity test equipment consisted of the movable electrode, dust cup, and furnace. As the resistivity of fly ash in the operating temperature($150{\circ}C$) of an electrostatic precipitator was measured higher than $1010{\Omega}{\cdot}$cm, flue gas conditioning in the electrostatic precipitator to reduce the resistivity of fly ash is required.