• 제목/요약/키워드: dust flow behavior

검색결과 9건 처리시간 0.019초

난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구 (A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room)

  • 김연희
    • 건설안전기술
    • /
    • 통권41호
    • /
    • pp.80-87
    • /
    • 2007
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 centerline type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type,22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3\mum$, $1\mum$and $3\mum$dust except for $5\mum$showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

  • PDF

난류형 클린룸내의 Layout 변화에 따른 분진제거 특성에 관한 연구 (A Study on the Phenomena of Dust Removal by the Layout Changes in the Turbulent Type Clean Room)

  • 김연희;김홍
    • 한국안전학회지
    • /
    • 제21권5호
    • /
    • pp.46-52
    • /
    • 2006
  • The purpose of this paper is to investigate the removal efficiency of fine dusts as the configuration condition of machinery and equipments in Clean Room and to analyze the flowing behaviors of fine dusts as the layout of Clean Room. The layout of the Clean Room was classified into side layout type, 2 center line type and center concentration type layout, and the flow rates used in this research were 0.22m/s, 0.44m/s and 0.80m/s. Dust removal efficiency as layout change was decreased 37% for side layout type, 31% for 2 center line type and 20% for center concentration type layout at the flow rate of 0.22m/s, compared with the state without machinery and equipments in Clean Room. The efficiency was decreased 42% for side layout type, 22% for 2 center line type and 8% for center concentration type layout at the flow rate of 0.44m/s, and decreased 20% for side layout type, 18% for 2 center line type and 10% for center concentration type layout at the flow rate of 0.80m/s. According to the result of dust removal behavior, $0.3{\mu}m,\;1{\mu}m\;and\;3{\mu}m$ dust except for $5{\mu}m$ showed the higher change of the behavior in side layout type than in center concentration type layout due to the change of air flow. It was confirmed that removal behavior depends on the layout of machinery and equipments as the dust size decreases.

PoC 부착 싸이클론의 미세분진 유출 제어에 관한 연구 (Emission Control of Fine Dust from Gas-Solid Cyclone)

  • 조영민
    • 한국대기환경학회지
    • /
    • 제15권2호
    • /
    • pp.201-210
    • /
    • 1999
  • Cyclones have been extensively used in the industry for removing fine particles from the gaseous streams, based on simplicity in design and construction in association with low cost and flexibility to operate in extreme and harsh environments. However, industrial cyclones are typically not very efficient for particles smaller than 10μm. In this work, in order to improve the separation efficiency of reverse flow cyclones, a simple device named Post Cyclone(Poc) in installed on the top of an existing cyclone. Thereby the residual swirl present at the outlet (vortex finder) of a conventional cyclone has been used to capture the escaped dust from the cyclone in the PoC. The performance of PoC was closely evaluated by changing configuration of the PoC and operation condition. In addition, the dust behaviour in th PoC was investigated based on the hypothesis of residual vortex.

  • PDF

회전톱 재단기의 미세먼지 집진효율 향상을 위한 형상 설계 개선 (Shape Design Improvement of the Rotary Cutting Machine to Improve the Dust Capturing Efficiency using CFD)

  • 김기희;이희남;전완호
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2011년 춘계학술대회논문집
    • /
    • pp.508-511
    • /
    • 2011
  • Dust released from the rotating timber cutting process causes various kinds of diseases as well as safety issues. Although there were lots of efforts to reduce the amount of dust by installing large-sized dust collectors or by using expensive high-quality cutters, they proved to be not so effective. In this study we want to modify and improve the design of the rotary cutter system to prevent dust from being released to the environment as possible by using computational fluid dynamics (CFD) analysis. We have developed CFD models of the conventional cutter and several design modifications. Through the CFD analysis the characteristics of the air flow was predicted, and then the behavior of dust produced during the cutting process was analyzed for different designs. The most efficient design feature to capture dust inside the cutter as much as possible was chosen based on the CFD analysis results. Finally the prototype of the ratary saw machine was constructed and tested to check the dust capturing efficiency, which result is reasonably consistent with the predicted performance through the CFD analysis.

  • PDF

가연성 분진운의 층류화염 전파에 있어서 2차화염의 거동 (2nd Flame Phenomena in Laminar Flame Propagation of Dust-Air Mixtures)

  • 한우섭;정국삼
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.119-125
    • /
    • 1998
  • In long vertical duct, the aspect of second flame in laminar flame propagating through lycopodium-air mixtures and the behavior of dust particles in neighborhood in front of flame have been examined experimentally. In order to trace the development of second flame to its origin, the velocity and vorticity distribution of dust particles in front of flame were measured by using with the real-time PIV system. The velocity of particles was approximately zero at the central part of flame front and the ahead of the flame leading edge, but maximum near the duct wall. The flame velocity of second flame and the movement of leading flame edge depend mainly on behavior of dust particles by the flow distribution of temperature and pressure.

  • PDF

Modeling reaction injection molding process of phenol-formaldehyde resin filled with wood dust

  • Lee, Jae-Wook;Kwon, Young-Don;Leonov, A.I.
    • Korea-Australia Rheology Journal
    • /
    • 제20권2호
    • /
    • pp.59-63
    • /
    • 2008
  • A theoretical model was developed to describe the flow behavior of a filled polymer in the packing stage of reaction injection molding and predict the residual stress distribution of thin injection-molded parts. The model predictions were compared with experiments performed for phenol-formaldehyde resin filled with wood dust and cured by urotropine. The packing stage of reaction injection molding process presents a typical example of complex non-isothermal flow combined with chemical reaction. It is shown that the time evolution of pressure distribution along the mold cavity that determines the residual stress in the final product can be described by a single 1D partial differential equation (PDE) if the rheological behavior of reacting liquid is simplistically described by the power-law approach with some approximations made for describing cure reaction and non-isothermality. In the formulation, the dimensionless time variable is defined in such a way that it includes all necessary information on the cure reaction history. Employing the routine separation of variables made possible to obtain the analytical solution for the nonlinear PDE under specific initial condition. It is shown that direct numerical solution of the PDE exactly coincides with the analytical solution. With the use of the power-law approximation that describes highly shear thinning behavior, the theoretical calculations significantly deviate from the experimental data. Bearing in mind that in the packing stage the flow is extremely slow, we employed in our theory the Newtonian law for flow of reacting liquid and described well enough the experimental data on evolution of pressure.

밀폐된 컨베이어 벨트 내부의 분진 제거를 위한 환기 시스템의 수치해석적 분석 (Numerical Analysis of Ventilation System for Dust Removal Inside the Enclosed Conveyor Belt)

  • 이예승;정기진;김종민;노정훈
    • 한국입자에어로졸학회지
    • /
    • 제19권2호
    • /
    • pp.43-53
    • /
    • 2023
  • In this study, the ventilation system of the enclosed conveyor belt for coal transportation was evaluated, and the particle removal efficiency according to the ventilation conditions was identified using computational fluid dynamics and particle behavior analysis. The most effective way to remove dust generated inside the closed conveyor belt is to adjust the position of the exhaust port of the duct so that the air is exhausted around the rear of the conveyor belt. And this method seems to work for another narrow and long spaces where air enters in one direction. In addition, when the air flow rate of the each duct was less than 300 CMM, it was efficient to increase the flow rate of the duct located at the rear of the conveyor belt, and when the flow rate of the each duct was higher than 300 CMM, it was efficient to increase the flow rate of the duct located at the front of the conveyor belt.

물 난류에서의 암모니아 흡수 거동 해석 (Interpretation of Ammonia Absorption Behavior in Water Turbulent Flow)

  • 이상룡;박진원
    • 유기물자원화
    • /
    • 제27권3호
    • /
    • pp.75-80
    • /
    • 2019
  • 본 연구는 난류로 흐르는 물에서 미세먼지 전구체 중 하나인 암모니아가 흡수되는 거동을 해석하였다. 물의 흐름이 층류보다 난류인 조건에서 암모니아의 침투 깊이가 더 깊으므로 레이놀즈 수가 $10^4$보다 큰 난류 조건이 고려된다. 거동 해석을 위하여, 무차원 물질전달 지배방정식과 상온 기준의 일정한 물성치들이 사용되었다. 물에서의 암모니아 확산계수와 물의 동점도계수는 각각 $2.45{\times}10^{-9}m^2/s$$1{\times}10^{-6}m^2/s$이었다. 물에서의 암모니아 농도 분포는 암모니아에 노출되기 시작하는 지점으로부터의 위치에 대하여 산출되었다. 혼합 깊이에 따른 정량적인 분포 또한 도출되었다. 이와 같은 정량적인 해석은 난류로 흐르는 물이 층류로 흐르는 것과 비교하여 얼마나 더욱 효율적으로 암모니아를 제거할 수 있는지에 대한 통찰력을 제시할 수 있다.

대기입자의 원소성분 배출특성연구를 위한 반-연속식 입자채취시스템 적용 (Application of Semi-continuous Ambient Aerosol Collection System for Elemental Analysis)

  • 박승식;고재민;이동수
    • 한국대기환경학회지
    • /
    • 제28권1호
    • /
    • pp.39-51
    • /
    • 2012
  • Aerosol slurry samples were collected in 60-min interval using Korean Semi-continuous Elements in Aerosol Sampler (KSEAS) between May 19 and June 6, 2010 at an urban site of Gwangju. The $PM_{2.5}$ samples were collected with a flow rate of 16.7 L/min and particles are grown by condensation of water vapor in a condenser maintained at ${\sim}5^{\circ}C$ after saturation by direct injection of steam. The resulting droplets are collected in a liquid slurry with a airdroplet separator. Concentrations of 16 elements (Al, Fe, Mn, Ca, K, Cu, Zn, Pb, Cd, Cr, Ti, V, Ni, Co, As, Se) in the collected slurry samples were determined off-line by ICP-MS. KSEAS sample analysis encompassed the sampling periods for which 24-hr average elemental species concentrations were calculated for comparison with those derived from 24-hr integrated filter samples. Relationship between elemental species measured by two methods indicated high correlation coefficients (r), mostly greater than r of 0.80. However, we note that concentrations of Al, K, Ca, Mn, and Fe, which are often associated with crustal elemental particles, in the KSEAS samples, were substantially lower (1.4~11 times) than those found in the typical filter-based samples. This discrepancy is probably due to difficulties in transferring insoluble dust particles to the collection vials in the KSEAS. Temporal profiles of elemental concentrations indicate that some transient events in their concentrations are observed over the sampling periods. For the elemental species studied, atmospheric concentrations during the transient events increased by factors of 4 in Mn~80 in Zn, compared to their background levels. Principle component analyses were applied to the hourly KSEAS data sets to identify sources affecting the concentrations of the metal constituents observed. In this study, we conclude that hourly measurements for particle-bound elemental constituents were extremely useful for revealing the short-term variability in their concentrations and developing insights into their sources.