• Title/Summary/Keyword: duration reduction

Search Result 709, Processing Time 0.029 seconds

The Comparison of Long-term Effect of Botox® injection on Lower Face Contouring after Single injection and Long-term Repeated injections by Standardized Photograph Analysis (Botox®를 이용한 하안면윤곽술에서 단일시술과 장기간 반복시술의 효과 지속 기간의 비교: 표준화된 사진 계측을 이용한 분석)

  • Park, Mee Young;Ahn, Ki Young
    • Archives of Plastic Surgery
    • /
    • v.36 no.5
    • /
    • pp.654-659
    • /
    • 2009
  • Purpose: A botulinum toxin type A (BoNT - A) injection has been used as a noninvasive management for lower face contouring since 2000. The aim of this study was to compare reduction rate of lower face width for a longtime according to repeated Botox$^{(R)}$ injections on masseter muscles for lower face contouring procedure. Methods: Forty - five patients were analyzed for single session of Botox$^{(R)}$ injection and 13 patients were evaluated for repeated Botox$^{(R)}$ injections for over two years. Single injection group was tracked regular intervals at 1, 3, 6, 10, 12 months after injection, and repeated injection group was measured at every injection time. Twenty - five to thirty units of Botox$^{(R)}$ was injected into each masseteric muscle at five to six points at the prominent portions of the mandibular angle. Standardized frontal view of digital photographs were analyzed by Adobe Photoshop$^{(R)}$ (version CS3) to measure an reduction rate of lower face width. Results: Reduction rate was 3.7%, 6.9%, 6.2%, 4%, 4% at 1, 3, 6, 10, 12 months post injection each other in single injection group. However, more than 8% reduction rate was found in repeated injection group persistently for more than two years. Conclusion: This study shows that effective duration of Botox$^{(R)}$ injection for lower face contouring is expected to continue over one year clinically. Moreover, repeated injections maintained lower reduction rate consistently for a long time. Therefore, repeated injections on masseter muscles at regular intervals are most effective procedure for lower face contouring.

Removal of Pesticide Residues in Field-sprayed Leafy Vegetables by Different Washing Method (엽채류에 엽면 살포된 농약의 세척 방법에 따른 제거)

  • Kwon, Hyeyoung;Kim, Taek-Kyum;Hong, Su-Myeong;Kim, Chan-Sub;Baeck, Minkyeong;Kim, Doo-Ho;Son, Kyung-Ae
    • The Korean Journal of Pesticide Science
    • /
    • v.17 no.4
    • /
    • pp.237-243
    • /
    • 2013
  • Pesticides were sprayed on perilla leaf and leafy lettuce in a greenhouse and the reduction rate of pesticide residues on each vegetable by washing were tested. The reduction rate of pesticide residues by washing for 30 sec~3 min on perilla leaf were 3~63% in tap water, 2~58% in salt water, 6~74% in green tea water, and 8~86% in detergent solution. The detergent solution only showed significant difference in reduction rates compared to the tab water washing. Considering reduction effects of the washing duration, it was showed that the reduction rates were a pattern of inclining as the duration of washing process increased, but there was no significant difference in the reduction rates except the reduction rates between washing in the detergent solution for 1 min and 3 min. Comparing washing in flowing tab water and in stagnant tab water with leafy lettuce, the reduction rate by one time washing were 8~68% in flowing tab water and 7~64% in stagnant tab water. The water and the time used in this experiment were 17.5 L, 2.9 min with flowing tab water and 4 L, 1 min with stagnant tab water. The reduction rate by 3 times washing in stagnant tab water were 16.5~76.6%, and the water and the time used were 12 L, 3 min. Therefore, when the water and the time used to wash vegetables were considered, washing two or three times in stagnant tab water could be more effective than washing one time in flowing tab water.

Downscaling of Sunshine Duration for a Complex Terrain Based on the Shaded Relief Image and the Sky Condition (하늘상태와 음영기복도에 근거한 복잡지형의 일조시간 분포 상세화)

  • Kim, Seung-Ho;Yun, Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.18 no.4
    • /
    • pp.233-241
    • /
    • 2016
  • Experiments were carried out to quantify the topographic effects on attenuation of sunshine in complex terrain and the results are expected to help convert the coarse resolution sunshine duration information provided by the Korea Meteorological Administration (KMA) into a detailed map reflecting the terrain characteristics of mountainous watershed. Hourly shaded relief images for one year, each pixel consisting of 0 to 255 brightness value, were constructed by applying techniques of shadow modeling and skyline analysis to the 3m resolution digital elevation model for an experimental watershed on the southern slope of Mt. Jiri in Korea. By using a bimetal sunshine recorder, sunshine duration was measured at three points with different terrain conditions in the watershed from May 15, 2015 to May 14, 2016. The brightness values of the 3 corresponding pixel points on the shaded relief map were extracted and regressed to the measured sunshine duration, resulting in a brightness-sunshine duration response curve for a clear day. We devised a method to calibrate this curve equation according to sky condition categorized by cloud amount and used it to derive an empirical model for estimating sunshine duration over a complex terrain. When the performance of this model was compared with a conventional scheme for estimating sunshine duration over a horizontal plane, the estimation bias was improved remarkably and the root mean square error for daily sunshine hour was 1.7hr, which is a reduction by 37% from the conventional method. In order to apply this model to a given area, the clear-sky sunshine duration of each pixel should be produced on hourly intervals first, by driving the curve equation with the hourly shaded relief image of the area. Next, the cloud effect is corrected by 3-hourly 'sky condition' of the KMA digital forecast products. Finally, daily sunshine hour can be obtained by accumulating the hourly sunshine duration. A detailed sunshine duration distribution of 3m horizontal resolution was obtained by applying this procedure to the experimental watershed.

The Transient Response Characteristics of Compliant Coating to Pressure Fluctuations

  • Lee In-Won;Chun Ho-Hwan;Kim Jin
    • Journal of Mechanical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.533-544
    • /
    • 2006
  • The amplitude and phase lag of surface deformation were determined for a compliant coating under the action of turbulent pressure fluctuations. For this purpose, pressure fluctuations were measured experimentally. The amplitude and duration of coherent wave train of pressure fluctuations were investigated using digital filtration. The transient response was calculated for stabilization of forced oscillations of the coating in approximation of local deformation. The response of coating was analyzed with considerations of its inertial properties and limited duration of coherent harmonics action of pressure fluctuations. It is shown that a compliant coating interacts not with the whole spectrum of pressure fluctuations, but only with a frequency range near the first resonance. According to the analysis, with increasing elasticity modulus of the coating material E, deformation amplitude decreases as 1/E, and dimensionless velocity of the coating surface decreases as $1/\sqrt{E}$. For sufficiently hard coatings, deformation amplitude becomes smaller than the thickness of viscous sublayer, while surface velocity remains comparable to vertical velocity fluctuations of the flow.

Effect of Ultrasound on the Properties of Biodegradable Polymer Blends of Poly(lactic acid) with Poly(butylene adipate-co-terephthalate)

  • Lee, Sang-Mook;Lee, Young-Joo;Lee, Jae-Wook
    • Macromolecular Research
    • /
    • v.15 no.1
    • /
    • pp.44-50
    • /
    • 2007
  • This study investigated the effect of ultrasound irradiation on the blend of poly(lactic acid) (PLA) and poly(butylene adipate-co-terephthalate) (PBAT). The blends of PLA/PBAT(50/50) (PBAT50) were prepared in a melt mixer with an ultrasonic device attached. Thermal, rheological, and mechanical properties, morphology, and biodegradability of the sonicated blends were analysed. The viscosity of the sonicated blends was increased by the ultrasound irradiation owing to the strong interaction. The morphology of the sonicated blends was significantly dependent on the duration o the ultrasound irradiation. For PBAT50, the phase size reduction was maximized when the blends were ultrasonically irradiated for 30 sec. At longer duration of ultrasound irradiation, the PBAT phase underwent flocculation. Measurement of the tensile properties showed an increased breakage tensile stress and an enhanced Young's modulus when the blends were properly irradiated. This improvement was ascribed to better adhesion between the PLA matrix and the PBAT domain and to better dispersion of the PBAT phase. However, the tensile properties were maximized after excessive energy irradiation, which was ascribed to an emulsifying effect leading to coalescence of the PBAT phase. Impact strength was increased to reach a peak with the ultrasound irradiation, and was higher than the untreated sample for all sonicated samples due to the difference of failure mechanism between the tensile test and the impact test.

A Study on the Functional Electrical Stimulation (기능적 전기 자극에 대한 고찰)

  • Lim, Jong-Soo;Kim, Soon-Hee;Song, Young-Wha
    • Journal of Korean Physical Therapy Science
    • /
    • v.6 no.4
    • /
    • pp.187-199
    • /
    • 1999
  • Functional Electrical Stimulation (FES) is used for muscle reeducation, reduction of spasticity, delay of atrophy, and muscle strengthening. FES stronger stimulation than other forms of electrical stimulation. The efficacy of FES in improving function has been substantiated in the literature. Treatment programs employing FES - activation of muscular tissue through the intact peripheral nervous system - can be broken into five major categories, according to the goal of treatment. These broad areas would include the use of FES to: (1) a direct excitation onto the alpha motoneuron, through peripheral stimulation of the Ia myotatic sensory system and ascending afferent information, which will be integrated at conscious and subconscious level of the CNS. (2) The quality of a stimulated muscle contraction is determined by combination of many parameters, including stimulus amplitude, pulse duration, stimulus frequency, and duty cycle. (3) A unit that has a pulse duration between 200 and $400{\mu}sec$ will be more than adequate for FES applications. (4) The neuromuscular plasticity is critically important to return of function using muscle re-education and facilitation applications. (5) Prior to using FES as an electrical orthosis, the patient should build up endurance in the muscles to be stimu1ated during the gait cycle.

  • PDF

Experience of Surgical Treatment through Ambulatory Care Unit (일 병원에서 통원병실을 이용한 수술적 치료의 경험)

  • Sohn, Jong-Min;Ha, Nan-Kyung
    • Quality Improvement in Health Care
    • /
    • v.8 no.1
    • /
    • pp.84-94
    • /
    • 2001
  • Background : in order to adapt to changes of the medical environm interests that is drawn in ambulatory surgery are increased as a method of approaching a patients' satisfaction and cost-effective management. The purpose of this study is to a assess the operation which is able to perform through ambulatory care unit, to identify the problem in ambulatory surgery, and to increased the opportunity of ambulatory surgery with safety. Methods : Between May 13th, 1998 and June 30th, 2000, we performed surgical treatment through ambulatory care unit, and evaluate the results of them. The sorts of operation, duration of stay in the hospital, total cost of treatment, satisfaction of patients and safety if anesthesia were assessed. Results : We performed ambulatory surgery without serve complications and the patients were satisfied with surgical treatment through ambulatory care unit. In comparison of ambulatory and admission surgery, there was a reduction of cost to 16.7~25.3% in ambulatory surgery. Also, the duration of admission was 2 days shorter than admission surgery. Conclusions : According to our results, the surgical treatment through ambulatory care unit is safe and useful method that increase the quality of medical service, satisfaction of patients and reduce the cost of treatments.

  • PDF

Dimming Level Control Technique for Lighting / Communication Functions in Visible Light Communication Systems (가시광통신 시스템에서 조명/통신 기능을 위한 효과적인 Dimming level control 기법)

  • Lee, Kyu-Jin
    • Journal of Convergence for Information Technology
    • /
    • v.8 no.5
    • /
    • pp.153-158
    • /
    • 2018
  • In this paper, we have studied a dimming level control method to satisfy both lighting and communication performance in visible light communication system. In the case of the most commonly used OOK and RZ-OOK modulation schemes, continuous Burst Zero Duration will seriously degrade the lighting function. This causes not only the illumination but also the performance of the entire system to deteriorate. Through this study, we analyzed the dimming level characteristics of the existing system and proposed the Illegal Pulse Insertion (IPI) algorithm as a technique to increase the dimming level. Through this, it is possible to effectively control the dimming level and improve the QoS of both lighting and communication by resolving the flicker phenomenon and dimming level reduction in the existing modulation and demodulation system.

Effects of Local Anesthetic Cream on Pain Relief in Newborns During Venipuncture (신생아의 정맥천자시 통증 완화를 위한 국소마취 크림 적용 효과)

  • Kim, Hae-Won;Ahn, Hye-Young
    • Child Health Nursing Research
    • /
    • v.17 no.4
    • /
    • pp.215-221
    • /
    • 2011
  • Purpose: Newborns routinely experience pain associated with invasive procedures such as blood sampling, venipuncture, heelstick, or venous cannulation. This study was done to provide data for a nursing intervention to alleviate newborn pain clinically by investigating the effect of local anesthetic cream during venipuncture. Methods: Participants were 70 newborns hospitalized in the nursery. Informed Consent was obtained from parents of the newborns. Venipuncture for regular blood sampling was carried out for a test on 2 groups; the experimental, placebo group. The neonatal infant pain scale (NIPS), and duration of crying were measured to assess pain reaction. All neonatal behaviors were recorded on videotape. Results: There were significant differences in pain behavior during venipuncture (t=-4.752, p<.001), immediately after sampling (t=-5.591, p<.001), 3 minutes after puncture (t=-2.469, p=.017), and in duration of crying (t=-3.005, p=.004). Conclusion: Results show that local administration of EMLA cream before venipuncture causes a reduction in neonatal pain response, indicating that the EMLA cream has the effect of pain relief.

Evaluation of the Quality of Canned Seafood with Added Spice-oil Extract

  • Yoon, Ho Dong;Shulgin, Yu.P.;Lazhentseva, L. Yu;Shulgina, L.V.;Xie, Chengliang;Mok, Jong Soo;Kim, Jeong Gyun
    • Fisheries and Aquatic Sciences
    • /
    • v.18 no.1
    • /
    • pp.7-11
    • /
    • 2015
  • The influence of spice (cinnamon, allspice, black pepper)-oil extract on canned seafood quality was studied. During the processing of canned seafood, the substitution of spice-oil extract for vegetable oil (refined sunflower, corn, soybean and olive oil) resulted in a decrease in the heat resistance of spore microorganisms, making it possible to reduce the duration of sterilization for canned food to 5-10 min at $115^{\circ}C$. This reduction in the sterilization duration of canned seafood with spice-oil extract inhibited residual microflora in the product, thus reducing the deleterious effect of heating on the main food compounds while preserving protein digestibility.