• Title/Summary/Keyword: durability of concrete

Search Result 2,148, Processing Time 0.028 seconds

Regression analysis of the correlation between ultrasonic pulse velocity and strength to examine the demoulding time of non-sintered hwangto concrete (비소성 황토 콘크리트의 거푸집 탈형 시점 검토를 위한 초음파속도와 강도의 상관관계 회귀 분석)

  • Nam, Young-Jin;Kim, Won-Chang;Ryu, Jung-Lim;Choi, Hee-Yong;Choi, Hyeong-Gil;Lee, Tae-Gyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.159-160
    • /
    • 2023
  • Recently, interest in reducing cement has been growing. Hwangto, an eco-friendly material, has advantages such as air purification effect and humidity control, but when used, accidents such as form collapse may occur due to low strength and reduced durability. In order to quantitatively evaluate the timing of mold demolding, we would like to evaluate the timing of mold demolding through correlation with compressive strength using ultrasonic pulse velocity. As a result, the time at which 5 MPa is developed is after 20 hours for the test specimen of W/B 41 , in the case of W/B 33, NC33 and HTC33-15 were equally expressed at 12 hours, and HTC33-30 was expressed at 16 hours.

  • PDF

A Experiment Study for the Standard Performance and Test of Surface Finishing Material for Parking Slab (주차장 바닥용 표면 마감재의 안전성 평가 및 성능기준에 관한 연구)

  • Kim Gue-Tae;Kwon Shi-Won;Kwak Kyu-Sung;Oh Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2005.05a
    • /
    • pp.125-131
    • /
    • 2005
  • Recently, to improve condition car park, using surface finishing material for variety color and property epoxy resin, urethane, cement mixed resin mortar or polymeric resin, and so on. However, it is frequent noise and wear out of tier and waterproofing materials, when the car slip or stop in car park, To minimize these cases, It is necessary that reduction of repair cost through performance long term durability of surface finishing material, improvement inside condition such as reduce dirty and car accident and ensurance the expected life of concrete slab in car park. Especially, we have not any tech for quality control, construction tech, production technology for car park surface materials, that's why park slab is not safety and suffer a loss. For this problems, this paper is to test surface finishing materials and as that result, suggest quality standard in the car park.

  • PDF

Extraction of a crack opening from a continuous approach using regularized damage models

  • Dufour, Frederic;Pijaudier-Cabot, Gilles;Choinska, Marta;Huerta, Antonio
    • Computers and Concrete
    • /
    • v.5 no.4
    • /
    • pp.375-388
    • /
    • 2008
  • Crack opening governs many transfer properties that play a pivotal role in durability analyses. Instead of trying to combine continuum and discrete models in computational analyses, it would be attractive to derive from the continuum approach an estimate of crack opening, without considering the explicit description of a discontinuous displacement field in the computational model. This is the prime objective of this contribution. The derivation is based on the comparison between two continuous variables: the distribution if the effective non local strain that controls damage and an analytical distribution of the effective non local variable that derives from a strong discontinuity analysis. Close to complete failure, these distributions should be very close to each other. Their comparison provides two quantities: the displacement jump across the crack [U] and the distance between the two profiles. This distance is an error indicator defining how close the damage distribution is from that corresponding to a crack surrounded by a fracture process zone. It may subsequently serve in continuous/discrete models in order to define the threshold below which the continuum approach is close enough to the discrete one in order to switch descriptions. The estimation of the crack opening is illustrated on a one-dimensional example and the error between the profiles issued from discontinuous and FE analyses is found to be of a few percents close to complete failure.

Temporary Arch Bridges Assembled by Snap-fit GFRP Decks and Bolts (첨단복합소재 데크를 볼트결합한 조립식 아치가교의 거동분석)

  • Hong, Kee-Jeung;Lee, Sung-Woo;Choi, Sung-Ho;Khum, Moon-Seoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.23 no.3
    • /
    • pp.247-254
    • /
    • 2010
  • Due to lightweight and high durability of glass-fiber reinforced polyester (GFRP) materials, they are promising alternatives to conventional construction materials such as steel, concrete and wood. As good application examples of GFRP materials, several types of temporary arch bridges were suggested and verified by finite element analyses in our previous study where snap-fit GFRP decks were applied. In this paper, we conduct a structural performance test to verify safety and serviceability of the temporary arch bridge, where snap-fit GFRP decks are assembled by bolts. The structural problems occurred in this test are also discussed and improvement of temporary arch bridges is suggested to resolve the occurred structural problems.

A Study on Transferred Load Reduction effect of Low Elastic Pad through Dynamic Response Analysis (동적응답해석을 통한 저탄성패드의 전달하중 저감효과 연구)

  • Kim, Hyun-Ju;Lee, Il-Wha;Cho, Guk-Hwan
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2464-2472
    • /
    • 2011
  • Train runs on high speed and the concrete track is constructed. Rail fastening device needs to reduce elasticity, transferred load, noise, and vibration etc. Consequently, low elastic pad has a great impact of the durability and stability of the track. In this study, discussed in previous studies, static numerical analysis and real scale repeated loading test, followed by dynamic response analysis were implemented. The most distinctive characteristics of the model proposed is to simulate the real wheel behavior on rail. And the main analysis object is to evaluate and compare the deformation characteristics of the transition track while load reduction effect of transfer on roadbed assessed by various low elastic pad.

  • PDF

Development of a Convergence Monitoring Method for Cylindrical Structures by Optical Fiber Bragg Grating Sensor (광섬유 FBG센서를 이용한 원주형 구조물의 2차원 상대변위 모니터링기법 개발)

  • Lho, Byeong-Cheol;Kim , Jong-Woo;Kang , Suck-Hwa
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.10 no.4
    • /
    • pp.160-166
    • /
    • 2006
  • Optical Fiber Bragg Grating sensor has a good performance to measure microscopic displacement which can measure strain of lining concrete and cylindrical structure like high intensity containment building and it can present many advantages like a corrosion resistance from the durability point of view. Then it can measure plane geometrical displacement of cylindrical structures with two-way displacement FBG sensor module. According to the test result, measurement of FBG sensor is better performance than other electric sensor system and 2D-level measurement. As a test result, Resolution of the two-way displacement sensor module with FBG sensors are more 10 times than other LVDT or 2D surveying.

Evaluation of Static Spring Constant and Accelerated Life Prediction for Compression Set of Polyurethane Resilient Pad in Rail Fastening System

  • Lee, Seung-Won;Park, Jun-Young;Park, Eun-Young;Ryu, Sung-Hwan;Bae, Seok-Hu;Kim, Nam-Il;Yun, Ju-Ho;Yoon, Jeong-Hwan
    • Elastomers and Composites
    • /
    • v.53 no.4
    • /
    • pp.220-225
    • /
    • 2018
  • Resilient pads play a major role in reducing the impact of loads on a rail in a rail-fastening system, which is essentially used for a concrete track. Although a compression set test is commonly used to measure the durability of a resilient pad, the static spring constant is often observed to be different from the fatigue test. In this study, a modified compression set test method was proposed to monitor the variations in the compression set and static spring constant of a resilient pad with respect to temperature and time. In addition, the life of the resilient pad was predicted by performing an acceleration test based on the Arrhenius equation.

Impact effect analysis for hangers of half-through arch bridge by vehicle-bridge coupling

  • Shao, Yuan;Sun, Zong-Guang;Chen, Yi-Fei;Li, Huan-Lan
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.1
    • /
    • pp.65-75
    • /
    • 2015
  • Among the destruction instances of half-through arch bridges, the shorter hangers are more likely to be ruined. For a thorough investigation of the hanger system durability, we have studied vehicle impact effect on hangers with vehicle-bridge coupling method for a half-through concrete-filled-steel-tube arch bridge. A numerical method has been applied to simulate the variation of dynamic internal force (stress) in hangers under different vehicle speeds and road surface roughness. The characteristics and differences in impact effect among hangers with different length (position) are compared. The impact effect is further analyzed comprehensively based on the vehicle speed distribution model. Our results show that the dynamic internal force induced by moving vehicles inside the shorter hangers is significantly greater than that inside the longer ones. The largest difference of dynamic internal force among the hangers could be as high as 28%. Our results well explained a common phenomenon in several hanger damage accidents occurred in China. This work forms a basis for hanger system's fatigue analysis and service life evaluation. It also provides a reference to the design, management, maintenance, monitoring, and evaluation for this kind of bridge.

Durability of High Strength Concrete according to the amount of Admixture (혼화재의 사용량에 따른 고강도 콘크리트 내구성)

  • Kim, Dong-Baek;Lee, In-Duk;Lee, Jae-Won;Kim, Jong-Hoon
    • Proceedings of the Korean Society of Disaster Information Conference
    • /
    • 2022.10a
    • /
    • pp.301-302
    • /
    • 2022
  • 최근 들어 염해, 콘크리트의 탄산화, 동결융해 등의 열화요인 의하여 발생할 수 있는 콘크리트의 내구성에 대한 다양한 연구가 진행되고 있는데, 이러한 열화요인은 독립적이 아닌 복합열화의 형태로 작용하게 되는데, 열화현상을 저감하는 한 방편으로 플라이애쉬와 같은 혼화재를 사용하디도 한다. 플라이애쉬는 유동성 증진을 통한 내구성의 향상과, 수화열 저감을 통한 균열감소 및 장기강도 증진 등의 효과가 있으며, 시멘트를 대체함으로써 경제적인 효과를 유발하는 장점도 가지고 있다. 그러나 플라이애쉬는 품질편차가 크고, 경우에 따라서 미연탄소분에 의한 AE제 흡착 등으로 인한 콘크리트의 내구성 및 강도를 저하시킬 수 있는 요소를 내포하고 있으므로 사용 시 주의가 필요하다. 본 연구에서는 열화를 저감하고, 내구성을 갖는 고강도 콘크리트를 제조하기 위하여 다양한 배합비의 플라이애쉬 혼입 콘크리트를 실험한 후 그 결과를 분석·고찰함으로써 내구성 콘크리트의 제작 시 혼화재로서의 적용성 및 타당성을 검증하고자 하며, 플라이애쉬를 내구성 재료로 그 활용을 극대화하고, 다양한 플라이애쉬의 사용량과 물/결합재비(W/B)에 대하여 내구성이 높은 고강도 콘크리트 제조방법을 범용화하며, 그 품질을 평가하는 것을 목적으로 한다.

  • PDF

Properties of Hot Weather Nuclear Power Plant Concrete with Water Cooling Method and Retarding used (배합수 냉각방법 및 지연제 사용에 따른 서중 원전콘크리트의 특성)

  • Lee, Seung-Han;Jung, Yong-Wook;Jang, Seok-Soo;Yeo, In-Dong;Choi, Jong-Oh
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4602-4609
    • /
    • 2013
  • In summer and winter, the difference between the temperature during the day and that during the night is high, which leads to various problems during concrete placement, such as cracks and defects in the concrete as well as low durability and strength. Although nuclear power plant concrete is widely used for placement in all seasons, particular attention must be paid to its quality during the summer. Therefore, we evaluated the effects of a cooling method for mixing water, which is a commonly used hot weather precooling method, and the use of a retarder, on the characteristics of Nuclear Power Plant concrete. In the cooling method for mixing water, cold water at 5 was used, with 50% of the water content consisting of ice flakes. The effects of using a retarder were evaluated by reviewing the characteristics of the cement at the unset stage and after hardening. To evaluate the characteristics of the unset cement, we measured the slump, air volumes, setting times, and pressure strengths after hardening. Furthermore, we measured the heat of hydration at different temperatures; the loss of heat was minimized using insulation. Both the slump time and the complete ageing time of the air volume were found to be 120 min at $20^{\circ}C$ and 40 min at $40^{\circ}C$. In the case when the cooling method for mixing water was used and in the case when a retarder was used, the initial and final sets by penetration resistance were delayed, and the delay decreased with increasing air temperature. For the heat of hydration, the cooling method for mixing water not only lowered the maximum temperature but also delayed its attainment. However, the use of a retarder had no effect on the maximum temperature. Moreover, in the early ages (e.g., 3 and 7 days), the pressure strength of the concrete was lower than that of plain cement. However, the strength of 28-day concrete met the standard construction specifications.