• Title/Summary/Keyword: ductility factors

Search Result 179, Processing Time 0.025 seconds

Seismic Fragility of Bridges in terms of Seismic Performance of RC Piers (철근콘크리트 교각의 내진성능에 따른 교량의 지진취약도)

  • Lee, Dae-Hyoung;Park, Chang-Kyu;Kim, Hyun-Jun;Chung, Young-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.93-96
    • /
    • 2006
  • This study represents results of performance-based fragility analysis of reinforced concrete (RC) bridge. Monte carlo simulation is performed to study nonlinear dynamic responses of RC bridge. Two-parameter log-normal distribution function is used to represent the fragility curves. These two-parameters, referred to as fragility parameters, are estimated by the traditional maximum likelihood procedure, which. is treated each event of RC bridge pier damage as a realization of Bernoulli experiment. In order to formulate the fragility curves, five different damage states are described by two practical factors: the displacement and curvature ductility, which are mostly influencing on the seismic behavior of RC bridge piers. Five damage states are quantitatively assessed in terms of these seismic ductilities on the basis of numerous experimental results of RC bridge piers. Thereby, the performance-based fragility curves of RC bridge pier are provided in this paper.

  • PDF

Factors Affecting Longitudinal Tensile Strength of SiC/Ti-Al-V Composites Manufactured by Plasma Spraying

  • Baik, Kyeong-Ho
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.514-515
    • /
    • 2006
  • In this study, multi-ply SiC fiber reinforced Ti-6Al-4V composites have been manufactured by plasma spraying and subsequent vacuum hot pressing. Two different sizes of Ti-6Al-4V feedstock powders were used for plasma spraying to form matrix. A considerable amount of oxygen was incorporated into as-sprayed Ti matrix during plasma spraying, and consequently caused matrix embrittlement. The use of coarse-sized feedstock powder reduced oxygen contamination, but tended to increase fiber spacing irregularity and fiber strength degradation. Longitudinal tensile strength and ductility of the composites were mainly affected by the matrix oxygen content.

  • PDF

Evaluation of performance and seismic parameters of eccentrically braced frames equipped with dual vertical links

  • Mohsenian, Vahid;Nikkhoo, Ali
    • Structural Engineering and Mechanics
    • /
    • v.69 no.6
    • /
    • pp.591-605
    • /
    • 2019
  • Investigations on seismic performance of eccentrically braced frames equipped with dual vertical links have received little attention. Therefore, the main goal of this paper is to describe design steps for such frames and evaluate nonlinear performance of this system according to the reliability analysis. In this study, four and eight story frame structures are analyzed and the response modification factors for different intensity and damage levels are derived in a matrix form based on a new approach. According to the obtained results, the system has high ductility and acceptable seismic performance. Moreover, it is concluded that using response modification factor equal to 8 in the design of system provides desirable seismic reliability under the design and maximum probable hazard levels. Due to desirable performance and significant advantages of the dual vertical links, this system can be used as a main lateral load bearing system, in addition to its application for rehabilitation of damaged structures.

Response modification factors of concrete bridges with different bearing conditions

  • Zahrai, Seyed Mehdi;Khorraminejad, Amir;Sedaghati, Parshan
    • Earthquakes and Structures
    • /
    • v.16 no.2
    • /
    • pp.185-196
    • /
    • 2019
  • One of the shortcomings of seismic bridge design codes is the lack of clarity in defining the role of different seismic isolation systems with linear or nonlinear behavior in terms of R-factor. For example, based on AASHTO guide specifications for seismic isolation design, R-factor for all substructure elements of isolated bridges should be half of those expressed in the AASHTO standard specifications for highway bridges (i.e., R=3 for single columns and R=5 for multiple column bent) but not less than 1.50. However, no distinction is made between two commonly used types of seismic isolation devices, i.e., elastomeric rubber bearing (ERB) with linear behavior, and lead rubber bearing (LRB) with nonlinear behavior. In this paper, five existing bridges located in Iran with two types of deck-pier connection including ERB and LRB isolators, and two bridge models with monolithic deck-pier connection are developed and their R-factor values are assessed based on the Uang's method. The average R-factors for the bridges with ERB isolators are calculated as 3.89 and 4.91 in the longitudinal and transverse directions, respectively, which are not in consonance with the AASHTO guide specifications for seismic isolation design (i.e., R=3/2=1.5 for the longitudinal direction and R=5/2=2.5 for the transverse direction). This is a clear indicator that the code-prescribed R-factors are conservative for typical bridges with ERB isolators. Also for the bridges with LRB isolators, the average computed R-factors equal 1.652 and 2.232 in the longitudinal and transverse directions, respectively, which are in a good agreement with the code-specified R-factor values. Moreover, in the bridges with monolithic deck-pier connection, the average R-factor in the longitudinal direction is obtained as 2.92 which is close to the specified R-factor in the bridge design codes (i.e., 3), and in the transverse direction is obtained as 2.41 which is about half of the corresponding R-factor value in the specifications (i.e., 5).

Response transformation factors and hysteretic energy distribution of reinforced concrete braced frames

  • Herian A. Leyva;Eden Bojorquez;Juan Bojorquez;Alfredo Reyes;Fabrizio Mollaioli;Omar Payan;Leonardo Palemon;Manual A. Barraza
    • Structural Engineering and Mechanics
    • /
    • v.90 no.3
    • /
    • pp.313-323
    • /
    • 2024
  • Most of existing buildings in Mexico City are made of reinforced concrete (RC), however, it has been shown that they are very susceptible to narrow-band long duration ground motions. In recent years, the use of dual systems composed by Buckling Restrained Braces (BRB) has increased due to its high energy dissipation capacity under reversible cyclical loads. Therefore, in this work the behavior of RC buildings with BRB is studied in order to know their performance, specifically, the energy distribution through height and response transformation factors between the RC and simplified systems are estimated. For this propose, seven RC buildings with different heights were designed according to the Mexico City Seismic Design Provisions (MCSDP), in addition, equivalent single degree of freedom (SDOF) systems were obtained. Incremental dynamic analyses on the buildings under 30 narrow-band ground motions in order to compute the relationship between normalized hysteretic energy, maximum inter-story drift and roof displacement demands were performed. The results shown that the entire structural frames participate in energy dissipation and their distribution is independent of the global ductility. The results let propose energy distribution equations through height. Finally, response transformation factors between the SDOF and multi degree of freedom (MDOF) systems were developed aimed to propose a new energy-based approach of BRB reinforced concrete buildings.

Seismic response of nonstructural components considering the near-fault pulse-like ground motions

  • Zhai, Chang-Hai;Zheng, Zhi;Li, Shuang;Pan, Xiaolan;Xie, Li-Li
    • Earthquakes and Structures
    • /
    • v.10 no.5
    • /
    • pp.1213-1232
    • /
    • 2016
  • This paper investigates the response of nonstructural components in the presence of nonlinear behavior of the primary structure considering the near-fault pulse-like ground motions. A database of 81 near-fault pulse-like ground motions is used to examine the effect of these ground motions on the response of nonstructural components. For comparison, a database of 573 non-pulse-like ground motions selected from the PEER database is also employed. The effects of peak ground velocity (PGV), maximum incremental velocity (MIV), primary structural degrading behavior and damping of nonstructural components are evaluated and discussed statistically. Results are presented in terms of amplification factor which quantifies the effect of inelastic deformations of the primary structure on subsystem responses. The results indicate that the near-fault pulse-like ground motions can significantly increase the amplification factors of nonstructural components with primary structural period and the magnitude of increase can reach 17%. The effect of PGV and MIV on amplification factors tends to increase with the increase of primary structural ductility. The near-fault pulse-like ground motions are more dangerous to components supported by structures with strength and stiffness degrading behavior than ordinary ground motions. A new simplified formulation is proposed for the application of amplification factors for design of nonstructural components for near-fault pulse-like ground motions.

Response scaling factors for nonlinear response analysis of MDOF system (다층건물의 비선형 반응해석을 위한 반응수정계수)

  • 한상환;이리형
    • Computational Structural Engineering
    • /
    • v.8 no.3
    • /
    • pp.103-111
    • /
    • 1995
  • Evaluating nonlinear response of a MDOF system under dynamic stochastic loads such as seismic excitation usually requires excessive computational efforts. To alleviate this computational difficulty, an approximation is developed in which the MDOF inelastic system is replaced by a simple nonlinear equivalent system(ENS).Me ENS retains the most important properties of the original system such as dynamic characteristics of the first two modes and the global yielding behavior of the MDOF system. The system response is described by the maximum global(building) and local(interstory) drifts. The equivalency is achieved by two response scaling factors, a global response scaling factor R/sub G/, and a local response scaling factor R/sub L/, applied to the responses of the ENS to match those of the original MDOF system. These response scaling factors are obtained as functions of ductility and mass participation factors of the first two modes of structures by extensive regression analyses based on results of responses of the MDOF system and the ENS to actual ground accelerations recorded in past earthquakes. To develop the ENS with two response scaling factors, Special Moment Resisting Steel Frames are considered. Then, these response scaling factors are applied to the response of ENS to obtain the nonlinear response of MDOF system.

  • PDF

Bond Strength of Super-CFRP Rod in Concrete

  • Seo, Sung-Tag
    • International Journal of Concrete Structures and Materials
    • /
    • v.18 no.1E
    • /
    • pp.29-34
    • /
    • 2006
  • Elastic modulus, tensile and bond capacities are important factors for developing an effective reinforcing action of a flexural member as a reinforcing material for concrete structures. Reinforcement must have enough bond capacity to prevent the relative slip between concrete and reinforcement. This paper presents an experimental study to clarify the bond capacity of prestressed carbon fiber reinforced polymer(CFRP) rod manufactured by an automatic assembly robot. The bond characteristics of CFRP rods with different pitch of helical wrapping were analyzed experimentally. As the result, all types of CFRP rods show a high initial stiffness and good ductility. The mechanical properties of helical wrapping of the CFRP rods have an important effect on the bond of these rods to concrete after the bond stress reached the yield point. The stress-slip relationship analyzed from the pull-out test of embedded cables within concrete was linear up to maximum bond capacity. The deformation within the range of maximum force seems very low and was reached after approximately 1 mm. The average bond capacity of CF20, CF30 and CF40 was about 12.06 MPa, 12.68 MPa and 12.30 MPa, respectively. It was found that helical wrapping was sufficient to yield bond strengths comparable to that of steel bars.

Optimal Manufacturing Conditions of Glass Fiber Reinforced PET Matrix Composites by Rapid Press Consolidation Technique (고속압밀법에 의해 제작된 유리섬유강화 PET 기지 복합재료의 최적제작조건)

  • Lee, Dong-Ju;Sin, Ik-Jae;Kim, Hong-Geon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.26 no.5
    • /
    • pp.813-821
    • /
    • 2002
  • Glass fiber reinforced PET matrix composite was manufactured by rapid press consolidation technique as functions of temperature, pressure and time in pre-heating, consolidation and solidification stages. The optimal manufacturing conditions for this composite were discussed based on the void content, tensile, interlaminar shear and impact properties. In addition, the levels of crystallinity with various manufacturing conditions were measured using differential scanning calorimetry to investigate the mechanical properties of this composite material as a function of crystallinity. Among many processing parameters, the mold temperature and the cooling rate after forming were found to be the most critical factors in determining the level of crystallinity and mechanical properties. The level of crystallinity affects the tensile properties to some degree. However, impact properties are affected much more. It also affects the degree of ductility, which determines the impact energy of this material.

Mechanical Behavior of Slender Concrete-Filled Fiber Reinforced Polymer Columns

  • Choi Sokhwan;Lee Myung;Lee Sung-Woo
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.4 s.82
    • /
    • pp.565-572
    • /
    • 2004
  • The mechanical behavior of concrete-filled glass fiber reinforced polymer columns is affected by various factors including concrete strength, stiffness of tube, end confinement effect, and slenderness ratio of members. In this research the behavior of slender columns was examined both experimentally and analytically. Experimental works include 1) compression test with 30cm long glass fiber composite columns under different end confinement conditions, 2) uni-axial compression test for 7 slender columns, which have various slenderness ratios. Short-length stocky columns gave high strength and ductility revealing high confinement action of FRP tubes. The strength increment and strain change were examined under different end confinement conditions. With slender columns, failure strengths, confinement effects, and stress-strains relations were examined. Through analytical work, effective length was computed and it was compared with the amount of reduction in column strength, which is required to predict design strength with slender specimens. This study shows the feasibility of slender concrete-filled glass fiber reinforced polymer composite columns.