• 제목/요약/키워드: duct design

검색결과 350건 처리시간 0.031초

기존 사무소건축의 IB화를 위한 리모델링 작업범위 (The Work Scope of Remodelling for the Intelligent Office Building)

  • 박근준;구수영
    • 한국건축시공학회지
    • /
    • 제4권1호
    • /
    • pp.75-83
    • /
    • 2004
  • The IB is normally defined in terms of BA, OA, security system, information processing and telecommunications services However, the buildings being already in existence are deficient in two areas. One of these areas is building envelope and plan. The other area is mechanical, electrical and structural systems which do not provide the environmental quality required by IB. Existing technology and design knowledge are available to address these deficiencies. Especially, the office buildings being already in existence must meet IB requirement in order to achieve desirable office environment. They are a building envelope, moisture control, properly-located windows, shafts for duct, telephone and electric closets and acoustical environments. In this paper, a new approach to construct the work scope of remodelling the office building being already existence is described by contrasting the building performance criteria of IB. It concludes by speculating on the consequences of extrapolating the results of study to remodelling the office building being already existence.

퍼지 LMS 알고리즘을 이용한 덕트의 능동소음제어 (Active noise control using fuzzy LMS algorithm in ducts)

  • 안동준;김균태;남현도
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 추계학술대회 논문집 학회본부
    • /
    • pp.373-375
    • /
    • 1994
  • In this paper, the fuzzy LMS algorithm where the convergence coefficient is computed by a fuzzy logic controller was proposed. The proposed fuzzy LMS algorithm showed better convergence property and stability than conventional LMS algorithms. The estimation error and misadaptation degree were used for Input of the fuzzy logic controller. In a airconditioning duct case, various conditions were investigated to design active noise controllers. A case with acoustic feedback, the proposed algorithm showed good performances through computer simulations.

  • PDF

한국형 고속전철 공조시스템 소음에 관한 연구 (Noise Characteristics of the HVAC System of Korea High Speed Train)

  • 하인수;박철희;이우식;한기흥
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 1998년도 추계학술대회 논문집
    • /
    • pp.379-387
    • /
    • 1998
  • HVAC systems are used to maintain comfort conditions in occupied spaces. Like rolling noise and aerodynamic noise, noise from the HVAC system of train increases interior noise level. For an appropriate interior noise level, it is necessary not to find noise sources and their propagation paths. Noise emission from the sources and propagation through the propagation paths should be regulated in order to reduce their effect to the interior noise level. In general, the main noise source in the HVAC system is blower which operates at high static pressure. This noise propagates through ducts which are directly connected to the residential area. Since the blower noise can be reduced only to some degree, it is necessary for the propagation paths to have enough noise attenuation. Acoustic properties of ducts are usually found by experimental methods but it is rather difficult and expensive to set up such test equipments. In this thesis, the design and the noise characteristics of TGV-K HVAC system are studied. Finite element method in accordance with experimental method is used to study the acoustic properties of TGV-K duct system.

  • PDF

전기집진기 내부의 유동 균일성 향상을 위한 가이드 배인의 최적설계 (Design of a Guide Vane for Improving Inside Flow Uniformity of Electrostatic Precipitator)

  • 노경욱;배성준;박숙희;강선균;이장명
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.523-528
    • /
    • 2013
  • In recent years, many efforts are increasingly being made to conserve the natural environment with enhanced emission standards and air quality standards. Also there are various methods necessary to be researched to minimize the emission of air pollutants. In particular, boilers of industrial facilities are major portions of the air pollution. The front duct which needs to be designed to reduce the gases to the electrostatic precipitator requires a bent tube, a reduction/extend tube and an auxiliary equipment, that is, a guide vane. This paper proposes an optimum design of the guide vane by a case study for electrostatic precipitator's flow uniformity. The operating conditions of this study are as follows: BMCR (Boiler Maximum Continuous Rate) and MGR (Maximum Guaranteed Rate) are 75%, 50%, and 30%; turbulent fluid dynamics model is based upon K-${\varepsilon}$ formulation. Presentation of the computed motion of particles is found to be quite useful to predict the precipitator performance by use CFD (Computational Fluid Dynamics).

On the development of the Anuloid, a disk-shaped VTOL aircraft for urban areas

  • Petrolo, Marco;Carrera, Erasmo;D'Ottavio, Michele;de Visser, Coen;Patek, Zdenek;Janda, Zdenek
    • Advances in aircraft and spacecraft science
    • /
    • 제1권3호
    • /
    • pp.353-378
    • /
    • 2014
  • This paper deals with the early development of the Anuloid, an innovative disk-shaped VTOL aircraft. The Anuloid concept is based on the following three main features: the use of a ducted fan powered by a turboshaft for the lift production to take-off and fly; the Coanda effect that is developed through the circular internal duct and the bottom portion of the aircraft to provide further lift and control capabilities; the adoption of a system of ducted fixed and swiveling radial and circumferential vanes for the anti-torque mechanism and the flight control. The early studies have been focused on the CFD analysis of the Coanda effect and of the control vanes; the flyability analysis of the aircraft in terms of static performances and static and dynamic stability; the preliminary structural design of the aircraft. The results show that the Coanda effect is stable in most of the flight phases, vertical flight has satisfactory flyability qualities, whereas horizontal flight shows dynamic instability, requiring the development of an automatic control system.

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 2004년도 추계학술발표회 발표논문집
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

도심지 대심도 복층터널의 내부구조물 계획 (A Design Focuses on the Internal Structure of Double-level Tunnel)

  • 박신영;정재호;조남각;신일재;심동현
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.1314-1321
    • /
    • 2010
  • The west express way which links south west area of the central city of Seoul has been notorious for extremely heavy traffics since its first opening in 1991(i.e. the average vehicle speed is less than 25km/h, a daily traffic is 112,000 and among them, more than 94% of the vehicles are the light vehicles). The city government recently initiated a new BTO(Build-Transfer-Operate) project as an alternative in releasing heavy traffic and a high construction cost. The proposed underground express road is the first double-level tunnel (i.e. a total length of road is 10,91km and the tunnel is 9.308km long) ever built in South Korea, while such tunnel system is not new worldwide as such A86 East tunnel in France, SMART tunnel in Malaysia, and Fuxing tunnel in China. This paper discusses major design issues regarding the internal structures such as deck slab, and secondary liner.

  • PDF

전산유체역학을 이용한 디젤엔진 부하시험장의 환기 개선에 관한 연구 (A Study on the Ventilation Improvement of Diesel Locomotive Engine Load Test Building using Computational Fluid Dynamics)

  • 박덕신;정병철;조영민;박병현
    • 한국대기환경학회지
    • /
    • 제21권2호
    • /
    • pp.227-242
    • /
    • 2005
  • The aim of this study is to relieve the poor ventilation problem of the diesel locomotive engine load test building, located in an urban area. This paper evaluates the ventilation performances of the studied load test building based on the temperature measurement experiment and the computational fluid dynamics (CFD) during the engine load test. The temperature rise caused by the radiator blower of the building was turned out to be the main cause of disturbing the thermal conditions of the building. The indoor temperature distributions simulated by Fluent were validated with the temperature measurement results obtained from the studied building. The simulation results indicated that the comfort condition of this building was poor We suggested several remedial changes in the duct structure of this building for the improvement of the comfort conditions. In addition, a prototype drawing combining several improved design options was proposed. and then the simulation of the temperature distribution in the proposed prototype was performed. The result indicated that the indoor thermal condition of this proposed building was improved when compared with that of the current building.

배연탈질 SCR 반응기내 유동균일 화를 위한 축소모형실험 및 전산해석 (Reduced Scale Model Experiments and Numerical Simulation for Flow Uniformity in de-NOx SCR Reactor)

  • 이인영;김동화;이정빈;류경옥
    • 한국대기환경학회지
    • /
    • 제17권4호
    • /
    • pp.347-354
    • /
    • 2001
  • SCR (Selective Catalytic Reduction) process is presently considered as one of the most effective techniques for removing nitric oxides from exhaust gases. In this study, based on the conceptually designed SCR reactor of 500 MW coal fired power plant. a reduced scale (1/20) SCR reactor model was made to analyze the flow pattern in front of catalyst layer according to the guide vane's design factors such as the number, interval, and angle of vanes. The results of the test were compared to those numerical simulation in order to assure the reliability of two methods. On the basis of our study. the critical Reynolds number (2.0$\times$ 10$^{5}$ ) was proposed for ensuring the similarity between the reduced scale model and the prototype of SCR reactor. Optimum design parameters of guide vanes were determined as follows, 4 vanes, the first vane angle of 93$^{\circ}$, and the vane intervals of 0.85 S/n, 1.05 S/n, 1.1 S/n, 1.0S/n, 1.0S/n (S: the distance of duct, n: the number of guide vanes). The excellent agreement between the results of the numerical simulation and the reduced scale model provides the validation of two methods for prediction of flow through SCR reactor.

  • PDF

막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구 (Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition)

  • 서진식;손정락;김재환;김동섭;노승탁
    • 한국유체기계학회 논문집
    • /
    • 제6권3호
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.