• 제목/요약/키워드: dual-threshold

검색결과 94건 처리시간 0.021초

잡음 환경에서의 전송율 감소를 위한 G.723.1 VAD 성능개선에 관한 연구 (The Research of Reducing the Fixed Codebook Search Time of G.723.1 MP-MLQ)

  • 김정진;박영호;배명진
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(4)
    • /
    • pp.98-101
    • /
    • 2000
  • On CELP type Vocoders G.723.1 6.3kbps/5.3kbps Dual Rate Speech Codec, which is developed for Internet Phone and videoconferencing, uses VAD(Voice Activity Detection)/CNG (Comfort Noise Generator) in order to reduce the bit rate in a silence period. In order to reduce the bit rate effectively in this paper, we first set the boundary condition of the energy threshold to prevent the consumption of unnecessary processing time, and use three decision rules to detect an active frame by energy, pitch gain and LSP distance. To evaluate the performance of the proposed algorithm we use silence-inserted speech data with 0, 5, 10, 20dB of SNR. As a result when SNR is over 5dB, the bit rate is reduced up to about 40% without speech degradation and the processing time is additionally decreased.

  • PDF

Single Fiber Composite(SFC) 시험법과 Acoustic Emission(AE)를 이용한 고분자 복합재료 계면전단강도 및 미세파손기구의 해석

  • 이준현;박종만;윤동진
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.656-659
    • /
    • 1993
  • The failure phenomenon of Dual Basalt Fibers Reinforced Epoxy Composites(DFC) under tensile load was studied using acoustic emission(AE) technique. AE amplitude and AE energy were mainly associated with the internal microscopic failure mechanism of DFC specimen, such as fiber fracture, matrix cracking, and fiber/matrix debonding. Fiber failures in the DFC specimens were distinguishable by showing the highest AE energy amplitude. They were dependant on the fiber diameters. Matrix cracking was determined from the relatively lower AE amplitude and AE energy, whereas fiber/matrix debonding could not be successfully isolated. AE method, however, can be applicable to the fragmentation method for interfacial strength(IFSS) in DFC specimens with adjusting the threshold to isolate fiber breaks from matrix crack and debonding.

  • PDF

P-I 곡선을 이용한 충격압력하중을 받는 철근 콘크리트 보의 손상해석 (Damage Analysis of RC Beams Subjected to Blast Load Using P-I Diagram)

  • 조정희;남진원;김호진;최형진;송하원;변근주
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계학술발표회 논문집(I)
    • /
    • pp.438-441
    • /
    • 2006
  • Since the behavior of structural members subjected to blast load shows different responses, the effect of impulse as well as peak load should be considered in the damage analysis. The threshold on P-I diagram that causes specific damage level divides the diagram into the failure zone and the non-failure zones. In this study, numerical analysis is performed based on single-degree-of-freedom (SDOF) techniques to generate rational P-I diagram considering material non-linearity and dual failure modes (flexure and direct shear) of RC beams. From the comparison with existing test results it is concluded that proposed numerical method is good to derive failure mode of RC beam under blast load.

  • PDF

강유전박막의 피로현상을 고려한 MFSFET 소자의 특성 (Device Characteristics of MFSFET with the Fatigue of the Ferroelectric Thin Film)

  • 이국표;강성준;윤영섭
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.191-194
    • /
    • 1999
  • Switching behaviour of the ferroelectric thin film and device characteristics of the MFSFET (Metal-Ferroelectric-Semiconductor FET) are simulated with taking into account the accumulation of oxygen vacancies near interface between the ferroelectric thin film and the bottom electrode caused by the progress of fatigue. We show net switching current decreases due fatigue in the switching model. It indicates that oxygen vacancy strongly suppresses polarization reversal. The difference of saturation drain current of the device before fatigue is shown by the dual threshold voltages in I$_{D}$-V$_{D}$ curve as 6㎃/$\textrm{cm}^2$ and decreases as much as 50% after fatigue. Our simulation model is expected to play an important role in estimation of the behavior of MFSFET device with various ferroelectric thin films.lms.

  • PDF

Hybrid Fault Detection and Isolation Techniques for Aircraft Inertial Measurement Sensors

  • Kim, Seung-Keun;Jung, In-Sung;Kim, You-Dan
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제7권1호
    • /
    • pp.73-83
    • /
    • 2006
  • In this paper, a redundancy management system for aircraft is studied, and fault detection and isolation algorithms of inertial sensor system are proposed. Contrary to the conventional aircraft systems, UAV system cannot allow triple or quadruple hardware redundancy due to the limitations on space and weight. In the UAV system with dual sensors, it is very difficult to identify the faulty sensor. Also, conventional fault detection and isolation (FDI) method cannot isolate multiple faults in a triple redundancy system. In this paper, two FDI techniques are proposed. First, hardware based FDI technique is proposed, which combines a parity equation approach with a wavelet based technique. Second, analytic FDI technique based on the Kalman filter is proposed, which is a model-based FDI method utilizing the threshold value and the confirmation time. To provide the reference value for detecting the fault, residuals are calculated using the extended Kalman filter. To verify the effectiveness of the proposed FDI methods, numerical simulations are performed.

Pilot observations of VLBI fringe survey at 43 GHz using VERA

  • 오정환;이상성;;;;손봉원
    • 천문학회보
    • /
    • 제36권2호
    • /
    • pp.60.1-60.1
    • /
    • 2011
  • We present the preliminary results of the pilot observations for the fringe survey at 43 GHz with the VLBI Exploration of Radio Astrometry (VERA). The main goals of the fringe survey are to establish a full list of phase calibrators for the VERA dual-beam astrometric observations, and for the KVN multi-frequency phase referencing observations. We performed two 24 hours experiments as a pilot observation to test the feasibility of the fringe survey. Each source from a list of 220 sources has been observed in one scan for 2 minutes. 67 sources were detected with the SNR threshold of 3.5. The correlated flux densities of the detected sources are presented in four ranges of projected baseline lengths.

  • PDF

複合組織鋼의 疲勞균열진전거동과 균열닫힘조건에 미치는 應力比 및 微視組織크기의 영향 (Influence of stress ratio and microstructural size on fatigue crack growth and crack closure in near-threshold)

  • 김정규;황돈영
    • 대한기계학회논문집
    • /
    • 제12권6호
    • /
    • pp.1343-1349
    • /
    • 1988
  • In this study, it is investigated for the effects of stress ratio and grain size on fatigue crack growth behavior and crack closure, in ferrite-martensite dual phase steels. The results obtained are as follows ; .DELTA. $K_{th}$ is independent of the ferrite grain size, but decreases with increasing stress ratio. The relation between .DELTA. $K_{th}$ and stress ratio R is as follows : .DELTA. $K_{th}$ =15.1(1-0.95R). But (.DELTA. $K_{eff}$)$_{th}$ in terms of crack closure is approximately 2.5 MPa.root.m. Also, variation of the degree of crack deflection to crack tip opening displacement at the minimum load is considered as a parameter of crack closure.e.e.

다중 거리 센서를 사용한 강의용 광역 마이크 시스템 (Wide-range Lecturing Microphone System using Multiple Range Sensor)

  • Oh, Woojin
    • 한국정보통신학회논문지
    • /
    • 제26권5호
    • /
    • pp.808-811
    • /
    • 2022
  • In this paper, a wide-range microphone system for lectures using dual 3D sensors is proposed. A previous work using a single sensor had lowering the detecting threshold to support wide-area. However it was found that an error occurred when lecturer wears clothes with low reflectivity or has small body size. When multiple sensors are used to expand the coverage it could be cause various problems. Each sensor could show different distance to the same target. We derive the rotation angle and and compensate for lecturing microphone system using sensors on the line. The proposed method shows a little improvement in performance by about 1dB compared to the previous works but the performance is uniform in all areas regardless of reflectivity.

Dwell Time Optimization of Alert-Confirm Detection for Active Phased Array Radars

  • Kim, Eun Hee;Park, JoonYong
    • Journal of electromagnetic engineering and science
    • /
    • 제19권2호
    • /
    • pp.107-114
    • /
    • 2019
  • Alert-confirm detection is a highly efficient method to improve phased array radar search performance. It comprises sequential detection in two steps: alert detection, in which a target is detected at a low detection threshold, and confirm detection, which is triggered by alert detection with a longer dwell time to minimize false alarms. This paper provides a design method for applying the alert-confirm detection to multifunctional radars. We find optimum dwell times and false alarm probabilities for each alert detection and confirm detection under the dual constraints of total false alarm probability and maximum allowable dwell time per position. These optimum values are expressed as a function of the mean new target appearance rate. The proposed alert-confirm detection increases the maximum detection range even with a shorter frame time than that of uniform scanning.

흰쥐의 adjuvant-induced knee arthritis에 대한 신음허 약침의 치료효과 (Anti-arthritic Properties of ShinEumHur-Herbal Acupuncture Assessed by Knee Circumference, Squeak Threshold and Weight Distribution Ratio in Rats)

  • 김건호;함대현;이한창;염미정;한동오;조미애;심인섭;김장현;이혜정
    • 동의생리병리학회지
    • /
    • 제18권4호
    • /
    • pp.1001-1006
    • /
    • 2004
  • In order to examine the anti-arthritic properties of ShinEumHur(SEH)-herbal acupuncture, an adjuvant-induced arthritic rat was generated by the intra-articular injection of dried cells of Mycobacterium tuberculosis emulsified in squalene into the right knee joint. Fifty microliter of SEH extract was injected into Zusanli(ST36) acupoint on the ipsilateral hind paw every other day for 2 weeks. The body weight, knee circumference, squeak threshold, and weight distribution ratio were analyzed as the assessment methods addressing arthritic symptoms such as arthritic pain, edema, and tenderness. The weight distribution ratio was measured by a digital-type analgesia instrument using the dual channel scale that separately measures the weight the arthritic rat distributes to each hind paw, and thus quantifies both of swelling and pain severities at once. The therapeutic effects of SEH-herbal acupuncture, assessed by squeaking threshold and weight distribution ratio, were observed on 8th day after the arthritis induction as compared to saline group and control group. On 10th day, SEH-herbal acupuncture therapy significantly started to alleviate the growing pattern of knee circumference of an arthritic rat in the range of 0.2㎝. However, the loss of body weight was not significantly recovered. Taken together, the SEH-herbal acupuncture exhibited the significant therapeutic efficiency to treat adjuvant-induced monoarthritis in rat.