• Title/Summary/Keyword: dual value structure

Search Result 52, Processing Time 0.028 seconds

Seismic response of dual structures comprised by Buckling-Restrained Braces (BRB) and RC walls

  • Beiraghi, Hamid
    • Structural Engineering and Mechanics
    • /
    • v.72 no.4
    • /
    • pp.443-454
    • /
    • 2019
  • In order to reduce the residual drift of a structure in structural engineering field, a combined structural system (dual) consisting of steel buckling-restrained braced frame (BRBF) along with shear wall is proposed. In this paper, BRBFs are used with special reinforced concrete shear walls as combined systems. Some prototype models of the proposed combined systems as well as steel BRBF-only systems (without walls) are designed according to the code recommendations. Then, the nonlinear model of the systems is prepared using fiber elements for the reinforced concrete wall and appropriate elements for the BRBs. Seismic responses of the combined systems subjected to ground motions at maximum considered earthquake level are investigated and compared to those obtained from BRBFs. Results showed that the maximum residual inter-story drift from the combined systems is, on average, less than half of the corresponding value of the BRBFs. In this research, mean of absolute values of the maximum inter-story drift ratio demand obtained from combined systems is less than the 3% limitation, while this criterion has not been fulfilled by BRBF systems.

A Sub-Wavelength Focusing Lens Composed of a Dual-Plate Metamaterial Providing a Negative Refractive Index

  • Kim, Dong-Ho
    • Journal of electromagnetic engineering and science
    • /
    • v.12 no.1
    • /
    • pp.26-31
    • /
    • 2012
  • We have proposed a metamaterial lens that enables sub-wavelength focusing, which is shorter than an operating wavelength. Our lens is a two dimensional array of a unit cell consisting of a metallic dual-plate printed on a dielectric substrate. The unique dual-plate structure provides negativeness both in permittivity and permeability, with no help from conventional additional structures, which are normally printed on the opposite of metallic patterns. Therefore, we can focus a source (or an image) in a tiny distance shorter than the free space wavelength (${\lambda}$) at the frequencies of interest. Furthermore, since the proposed geometry does not need separate supplementary structures to acquire negative permittivity or permeability, our lens is much simpler than conventional metamaterial lenses, which is a strong point in practical applications. We have validated sub-wavelength focusing ability in a 6 GHz frequency band through an experiment of near field scanning, which provided the width of about 0.19 ${\lambda}$ at a half maximum of a peak value of an measured image. The width of the focused image through the lens is more than 4 times shorter than that without the lens, which confirms the validity of our design approach.

Design of a High Performance Two-Step SOVA Decoder (고성능 Two-Step SOVA 복호기 설계)

  • 전덕수
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.7 no.3
    • /
    • pp.384-389
    • /
    • 2003
  • A new two-step soft-output Viterbi algorithm (SOVA) decoder architecture is presented. A significant reduction in the decoding latency can be achieved through the use of the dual-port RAM in the survivor memory structure of the trace-back unit. The system complexity can be lowered due to the determination of the absolute value of the path metric differences inside the add-compare-select (ACS) unit. The proposed SOVA architecture was verified successfully by the functional simulation of Verilog HDL modeling and the FPGA prototyping. The SOVA decoder achieves a data rate very close to that of the conventional Viterbi Algorithm (VA) decoder and the resource consumption of the realized SOVA decoder is only one and a half times larger than that of the conventional VA decoder.

Design of a Dual-Band Loop-Type Ground Antenna Using Lumped-Elements (집중 소자를 사용한 이중 대역 루프형 그라운드 안테나 설계)

  • Lee, Hyung-Jin;Liu, Yang;Lee, Jae-Seok;Kim, Hyung-Hoon;Kim, Hyeong-Dong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.5
    • /
    • pp.551-558
    • /
    • 2012
  • This paper presents a dual band loop-type ground antenna using lumped-elements that control the impedance bandwidth and resonant frequency. The dual-band operation of the proposed antenna is realized by inserting an additional resonated loop feed structure into the reference ground antenna. As the proper value of the capacitor and the inductor are chosen, the impedance bandwidth of our antenna with voltage standing wave ratio(VSWR) equal to 3 is 85 MHz and 725 MHz at the 2.45 and 5.5 GHz frequency band, respectively. Its validity is demonstrated via both the computed and measured results. Good antenna patterns and efficiencies are achieved at the dual frequency bands, as well as the physically small antenna element size($10{\times}5mm^2$).

A Study on the Fatigue-Fractured Surface of Normalized SS41 Steel and M.E.F. Dual Phase Steel by an X-ray Diffraction Technique (X-선 회절에 의한 SS41 불림재와 M.E.F. 복합 조직강의 피로 파단면 해석에 관한 연구)

  • Oh, Sae-Wook;Park, Young-Chul;Park, Soo-Young;Kim, Deug-Jin;Hue, Sun-Chul
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.10-18
    • /
    • 1996
  • This study verified the relationship between fracture mechanics parameters and X-ray parameters for normalized SS41 steel with homogeneous crystal structure and M.E.F. dual phase steel(martensite encapsulated islands of ferrite). The fatigue crack propagation test were carried out and X-ray diffraction technique was applied to fatigue fractured surface. The change in X-ray parameters(residual stress, half-value breadth) according to the depth of fatigue fractured surface were investigated. The depth of maximum plastic zone, $w_y$, were determined on the basis of the distribution of the half-value breadth for normalized SS41 steel and that of the residual stress for M.E.F. dual phase steel. $K_{max}$ could be estimated by the measurement of $w_y$.

  • PDF

Study on the Response Modification Factor for a Lightweight Steel Panel-Modular Structure Designed as a Dual Frame System (이중골조시스템으로 설계된 복강판-모듈러 구조물의 반응수정계수에 관한 연구)

  • Lee, Eo-Jin;Hong, Sung-Gul
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.1
    • /
    • pp.39-48
    • /
    • 2011
  • In this present study, a response modification factor for a lightweight steel panel-modular system which is not clarified in a current building code was proposed. As a component of the response modification factor, an over-strength factor and a ductility factor were drawn from the nonlinear static analysis curves of the systems modeled on the basis of the performance tests. The final response modification factor was then computed by modifying the previous response modification factor with a MDOF (Multi-Degree-Of-Freedom) base shear modification factor considering the MDOF dynamic behaviors. As a result of computation for the structures designed as a dual frame system, ranging from 2-story to 5-story, the value of 4 was estimated as a final response modification factor for a seismic design, considering the value of 5 as an upper limit of the number of stories.

Preparation of highly hydrophobic PVDF hollow fiber composite membrane with lotus leaf-like surface and its desalination properties

  • Li, Hongbin;Zi, Xingchen;Shi, Wenying;Qin, Longwei;Zhang, Haixia;Qin, Xiaohong
    • Membrane and Water Treatment
    • /
    • v.10 no.4
    • /
    • pp.287-298
    • /
    • 2019
  • Lotus leaf has a special dual micro and nano surface structure which gives its highly hydrophobic surface characteristics and so-called self cleaning effect. In order to endow PVDF hollow fiber membrane with this special structure and improve the hydrophobicity of membrane surface, PVDF hollow fiber composite membranes was obtained through the immersion coating of poly(vinylidene fluoride-co-hexafluoropropylene) (PVDF-HFP) dilute solution on the outside surface of PVDF support membrane. The prepared PVDF composite membranes were used in the vacuum membrane distillation (VMD) for the desalination. The effects of PVDF-HFP dilute solution concentration in the dope solution and coating time on VMD separation performance was studied. Membranes were characterized by SEM, WCA measurement, porosity, and liquid entry pressure of water. VMD test was carried out using $35g{\cdot}L^{-1}$ NaCl aqueous solution as the feed solution at feed temperature of $30^{\circ}C$ and the permeate pressure of 31.3 kPa. The vapour flux reached a maximum when PVDF-HFP concentration in the dilute solution was 5 wt% and the coating time was kept in the range of 10-60 s. This was attributed to the well configuration of micro-nano rods which was similar with the dual micro-nano structure on the lotus leaf. Compared with the original PVDF membrane, the salt rejection can be well maintained which was greater than 99.99 % meanwhile permeation water conductivity was kept at a low value of $7-9{\mu}S{\cdot}cm^{-1}$ during the continuous testing for 360 h.

Dual Band Optical Window (DBW) for Use on an EO/IR Airborne Camera

  • Park, Kwang-Woo;Park, Sang-Yeong;Kim, Young-Soo;Kim, Ki-Ho;Choi, Young-Soo
    • Journal of the Optical Society of Korea
    • /
    • v.16 no.1
    • /
    • pp.63-69
    • /
    • 2012
  • This paper presents a method to derive the theoretical requirements for the development of a 400 mm optical window that transmits dual-band wavelengths and had a stable structure. We also present design and fabrication results. Among the required specifications, the surface figure error was defined by the transmitted wavefront deformation (TWD), ${\lambda}$/15 rms at 632.8 nm. This value was derived by estimating the predicted performances with respect to five independent items that could cause system performance degradation and then calculating the required wavefront error (WFE) to satisfy the performance goals. We measured the image resolution at each performance level to trace and verify the requirements. The article also describes a design optimization process that could minimize the weight and volume of the optical window attached to the payload securing the FOV of the camera. In addition, we accurately measured the deformation that occurred in the series of fabrication steps including processing, coating, assembly, bonding and bolting, and investigated the effects by comparing them to the results of a simulation performed in advance to derive the predicted performance.

A Study on Estimation of Labor Value of Female Fishermen (여성어업인의 노동가치 추정에 관한 연구)

  • Jong-Cheon, Kim;Chang-Soo Lee
    • The Journal of Fisheries Business Administration
    • /
    • v.54 no.2
    • /
    • pp.1-14
    • /
    • 2023
  • The sustainability of fishing villages is threatened by manpower shortages due to population aging and poor settlement conditions. In the reality of poor fishing villages, the importance of women's labor is more emphasized than that of the past because female workers are key workers in fishing labor, processing and sales of marine products. However, policy support for female fishermen is not sufficient. The reason for this is that policy makers did not properly recognize the labor value of female fishermen. In fact, fishing villages have emphasized the importance of female workforce as a slogan, but there has been no attempt to estimate the labor value. There was not even a review of the methodology for estimating the value of labor that was attempted in similar fields. As a result, the policy importance of female fishermen was underestimated for there was no attempt to evaluate their value even though women had been continuously participating in the fishery from the past. Female fishermen's labor is under the dual labor structure of housework and fishing labor. Therefore, in this study, housework and fishing labor were estimated separately and the total labor value was calculated. The basic data necessary for estimating the labor value of female fishermen were obtained through a survey. The method of estimating the labor value of female fishermen was used in combination with the present income method and the total replacement cost method. As a result of the study, the total labor value of female fishermen was about 4.4 trillion won, which is about half of the total fishery production of 9 trillion won in Korea.

Low Phase Noise VCO with X -Band Using Metamaterial Structure of Dual Square Loop (메타구조의 이중 사각 루프를 이용한 X-Band 전압 제어 발진기 구현에 관한 연구)

  • Shin, Doo-Soub;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.12
    • /
    • pp.84-89
    • /
    • 2010
  • In this paper, a novel voltage-controlled oscillator (VCO) using the microstrip square open loop dual split ring resonator is presented for reducing the phase noise. The square-shaped dual split ring resonator having the form of the microstrip square open loop is investigated to reduce the phase noise. Compared with the microstrip square open loop resonator and the microstrip square open loop split ring resonator as well as the conventional microstrip line resonator, the microstrip square dual split ring resonator has the larger coupling coefficient value, which makes a higher Q value, and has reduced the phase noise of VCO. The VCO with 1.7V power supply has the phase noise of -123.2~-122.0 dBc/Hz @ 100 kHz in the tuning range, 11.74~11.75 GHz. The figure of merit (FOM) of this VCO is-214.8~-221.7 dBc/Hz dBc/Hz @ 100 kHz in the same tuning range. Compared with VCO using the conventional microstrip line resonator, VCO using microstrip square open loop resonator, the phase noise of VCO using the proposed resonator has been improved in 26 dB, 10 dB, respectively.