• 제목/요약/키워드: dual system

Search Result 2,715, Processing Time 0.031 seconds

A Preliminary Study of Korean Dual-Frequency SBAS

  • Yun, Ho;Han, Deokhwa;Kee, Changdon
    • Journal of Positioning, Navigation, and Timing
    • /
    • v.3 no.1
    • /
    • pp.11-16
    • /
    • 2014
  • A Satellite Based Augmentation System (SBAS) is a representative differential GNSS system, which is used for the navigation performance improvement of Global Navigation Satellite System (GNSS) users. SBAS has been developed focusing on the securement of user integrity so that it can be used for the navigation in aviation fields. Accordingly, the development of SBAS has been completed, and it has been actively used in the United States, Europe, and Japan. As the new satellite of Global Positioning System (GPS) recently started to broadcast new civil signals (L5 frequency), the methods for improving user navigation performance in SBAS using this signal have also been studied. In Korea, to keep pace with these circumstances, full-scale SBAS development is expected to start in 2014, and studies on dual-frequency SBAS using L1/L5 frequencies will also be performed. In this study, before the full-scale development of dual-frequency SBAS in Korea, a simulation was performed to predict the performance and analyze the expected effects.

A Study on the Implementation of WiBro/HSDPA Dual mode Access Point System (WiBro/HSDPA Dual mode AP 시스템 구현에 관한 연구)

  • Ha, Kwang-Jun;Kim, Sung-Ill;Oh, Young-Chul;Lee, Sang-Hong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2007.08a
    • /
    • pp.64-68
    • /
    • 2007
  • Commercial WiBro and 3G HSDPA services are launched last year in order to provide high speed wireless Internet access and multimedia service. Currently mobile communication service providers concentrate on the deployment of indoor mobile network since indoor traffic is remarkably increased. For fine indoor wireless communication, an installation of access point system via Public IP network which is called Femtocell is required. The development of indoor Femtocell system must be considered in the viewpoint of low hardware complexity, cost reduction, interlocking with WiBro/HSDPA network without change of network component and easy element management. In this paper, we review the implementation issue and technology of dual mode AP which provides WiBro and HSDPA signal to the user simultaneously. Especially, we describe on the HSDPA Femtocell standardization status and possible 3 types of HSDPA communication module development design. Furthermore we analyze the merits and demerits of each HSDPA Femtocell design type and propose a system which enables handover between indoor HSDPA Femtocell and outdoor commercial HSDPA mobile network.

  • PDF

Development of Low-Vibration Controller for Ultra-Precision Dual Stage (초정밀 듀얼 스테이지를 위한 고댐핑 저진동 제어기 개발)

  • Kang, Seok Il;Kim, Jung-Han
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.25 no.1
    • /
    • pp.75-82
    • /
    • 2016
  • In this study, a cross-damped low vibration controller was developed to reduce vibration in ultra-precision dual stage driven by master/slave principle. In master-slave structure, the master stage leads the driving motion and the slave stage follows it so as to maintain a constant gap between two stages. In this structure, a small perturbation of master stage makes big oscillations in slave servoing stage, so a low damped master stage composed of voice coil motor makes a long vibration in settling area after driving motion profile. In this research, an effective feedback damping algorithm for increase the damping characteristics of the dual stage was developed. The designed velocity damping algorithm improves the system stability and reduces the settling time of the whole system. Simulation and experimental results show that the developed algorithm reduces settling time and improves the regulating performance.

Dual-rotor Wind Turbine Generator System Modeling and Simulation (이중 로터 풍력발전 시스템 모델링 및 시뮬레이션에 관한 연구)

  • Cho, Yun-Mo;No, Tae-Soo;Min, Byoung-Mun;Lee, Hyun-Hwa
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.32 no.6
    • /
    • pp.87-95
    • /
    • 2004
  • In this paper, an efficient method for modeling a dual-rotor type wind turbine generator system and simulation results are presented. The wind turbine is treated as a collection of several rigid bodies, each of which represents, respectively, main and auxiliary rotor blades, high/low speed shafts, generator, and gear system. Simulation software WINSIM is developed to implement the proposed modeling method and is used to investigate the transient and steady-state performance of the wind turbine system.

Effectiveness of One- and Dual-Stage Recycled-Water Systems in Slurry Bioreactor Treatment for Coal Tar-Contaminated Soil (콜타르 오염토양의 슬러리상 생물반응기 처리를 위한 일단 및 이단 재순환식 공정의 효율성)

  • NamKoong, Wan;Park, Jin-Hong;Lee, Noh-Sup;Kim, Joung-Dae;Park, Joon-Seok
    • Journal of Environmental Health Sciences
    • /
    • v.31 no.5 s.86
    • /
    • pp.423-430
    • /
    • 2005
  • This research was performed to evaluate the effectiveness of one- and dual-stage recycled-water systems in slurry bioreactor treatment for coal tar-contaminated soil. Silty loam soil was used for this research. Coal tar and 14 target PAHs (Polycyclic Aromatic Hydrocarbons) concentration in the soil were determined with gas chromatography. There was no significant difference between removal efficiencies of one- and dual-stage recycled water systems in case of about 4,000 mg coar tar/kg. However, the dual-stage system increased significantly the removal efficiency in case of about 20,000 mg coar tar/kg and the first-order kinetic constant of the system was over 1.5 times higher than that of one-stage recycled water system. 3-Ring compounds in PAHs was removed completely within 30 days of operation. Coar tar was removed in over 96% through biodegradation and removed in about 4% by evaporation. High correlation coefficient($r^2=0.91$) was found between water solubility and removal efficiency of the cyclic compounds.

A Study on the Design of Cross-Polarization Interference Canceler for Digital Radio Relay System with Co-Channel Dual Polarization (동일 채널 이중편파를 적용하는 디지털 무선 중계장치의 직교편파간섭제거기 설계에 관한 연구)

  • 서경환
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.3
    • /
    • pp.225-236
    • /
    • 2002
  • In this paper, to counteract a cross-polarization interference caused by co-channel dual polarization technique of digital radio relay system(DRRS), we analyze the theoretical model and digital design of cross-polarization interference canceller(XPIC). In addition a complex adaptive time domain equalizer(ATDE) is designed using a finite impulse response filter, and the structure of XPIC and its control method are also illustrated including ATDE. Our computer simulation shows that about 25 dB signature and more than 23 dB XPIC improvement factor can be obtained with XPIC and ATDE. In order to verify the operation of designed XPIC, we review the simulated results in view of tap number, algorithm convergence, system signature, and XPlC improvement factor in connection with 64-QAM DRRS with co-channel dual polarization.

Numerical verification of a dual system's seismic response

  • Phocas, Marios C.;Sophocleous, Tonia
    • Earthquakes and Structures
    • /
    • v.3 no.5
    • /
    • pp.749-766
    • /
    • 2012
  • Structural control through integration of passive damping devices within the building structure has been increasingly implemented internationally in the last years and has proven to be a most promising strategy for earthquake safety. In the present paper an alternative configuration of an innovative energy dissipation mechanism that consists of slender tension only bracing members with closed loop and a hysteretic damper is investigated in its dynamic behavior. The implementation of the adaptable dual control system, ADCS, in frame structures enables a dual function of the component members, leading to two practically uncoupled systems, i.e., the primary frame, responsible for the normal vertical and horizontal forces and the closed bracing-damper mechanism, for the earthquake forces and the necessary energy dissipation. Three representative international earthquake motions of differing frequency contents, duration and peak ground acceleration have been considered for the numerical verification of the effectiveness and properties of the SDOF systems with the proposed ADCS-configuration. The control mechanism may result in significant energy dissipation, when the geometrical and mechanical properties, i.e., stiffness and yield force of the integrated damper, are predefined. An optimum damper ratio, DR, defined as the ratio of the stiffness to the yield force of the hysteretic damper, is proposed to be used along with the stiffness factor of the damper's- to the primary frame's stiffness, in order for the control mechanism to achieve high energy dissipation and at the same time to prevent any increase of the system's maximum base shear and relative displacements. The results are summarized in a preliminary design methodology for ADCS.

Flux Weakening Control for Surface Mounted Permanent Magnet Synchronous Machine Driven by Dual Inverter (이중 인버터를 이용한 표면 부착형 영구자석 동기전동기의 약자속 제어)

  • Kim, Youngnam;Lee, Yongjae;Ha, Jung-Ik
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.5
    • /
    • pp.437-442
    • /
    • 2013
  • For open-end permanent magnet synchronous machine(PMSM) with dual inverter system, where one inverter is connected to the source and the other is flying, the dc link voltage of the flying inverter can be boosted through the machine. For this reason, when compared with single inverter drive system, higher voltage can be applied to PMSM, and higher torque can be generated in the flux weakening region. In this case, however, active and reactive powers are separately supplied by each inverter to maintain the dc link voltage of flying inverter. Therefore, the required flux weakening control is different from the conventional method for a single inverter drive system. This paper proposes the novel flux weakening control method which maximizes the active voltage component in a dual inverter PMSM drive system. The proposed method was demonstrated and verified through experimental results.

Direct Seek Control for Swing-arm Type Dual Stage Actuators in Blu-Ray Disc Drive Systems

  • Ryu, Shi-Yang;Jung, Soo-Yul;Yoon, Hyeong-Deok;Park, In-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.735-739
    • /
    • 2003
  • This paper presents a direct seek control algorithm for swing-arm type dual stage servo system that consists of a coarse actuator and a fine actuator. The proposed scheme is to design a control system that attenuates the effect of dynamic coupling between the two actuators so that the seek operation can be performed in a single-shot with stability. In an optical drive system with dual stage servo mechanism, the effect of dynamic coupling between the two actuators needs to be handled during the coarse seek operation due to its inherent structure. In an extreme case, the two actuators can collide each other, which leads to critical degradation of the seek performance. To handle this problem, our proposed control scheme is to generate the drive signals such that the two actuators behave as if they are a single fixed body. To this end, a feedforward controller and two feedback controllers are designed that enable the current drive system perform wide range of track seek. Simulation results are provided to show the validity and feasibility of our proposed algorithm.

  • PDF

Preparation and Evaluation of Self-cleaning Fabrics using Photocatalyst and Superhydrophobic Finishing (광촉매와 초발수 처리를 이용한 셀프클리닝 섬유의 제조 및 평가)

  • Jeong, Euigyung;Woo, Heejoo;Cho, Seungbin;Bae, Jin-Seok
    • Textile Coloration and Finishing
    • /
    • v.30 no.4
    • /
    • pp.288-293
    • /
    • 2018
  • This study reported the dual functional self-cleaning PET fabrics prepared from $TiO_2$ and hexadecyltrimethoxysilane treatment, which have photodegradation and superhydrophobicity on the fabric surface. Phodegradation and superhydrophobicity of the resulting fabric were compared with $TiO_2$ or silane treated fabrics. The dual functional self-cleaning PET fabric showed less photodegradation than the $TiO_2$ treated fabric. However, the dual functional self-cleaning fabrics showed superior superhydrophobicity to silane treated fabric with increased water contact angle and significantly decreased roll-off angle. This suggested that the dual functional PET fabric has a great potential to be the commercialized self-cleaning fabric because it is repellent to soil or dust and even if soil or dust is adsorbed on the fabric surface, it can be removed by water rolling off on the surface or photodegradation by the photocatalyst.