• Title/Summary/Keyword: dual microscope

Search Result 35, Processing Time 0.025 seconds

Characterization Method for Testing Circuit Patterns on MCM/PCB Modules with Electron Beams of a Scanning Electron Microscope (MCM/PCB 회로패턴 검사에서 SEM의 전자빔을 이용한 측정방법)

  • Kim, Joon-Il;Shin, Joon-Kyun;Jee, Yong
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.9
    • /
    • pp.26-34
    • /
    • 1998
  • This paper presents a characterization method for faults of circuit patterns on MCM(Multichip Module) or PCB(Printed Circuit Board) substrates with electron beams of a SEM(Scanning Electron Microscope) by inducing voltage contrast on the signal line. The experimentation employes dual potential electron beams for the fault characterization of circuit patterns with a commercial SEM without modifying its structure. The testing procedure utilizes only one electron gun for the generation of dual potential electron beams by two different accelerating voltages, one for charging electron beam which introduces the yield of secondary electron $\delta$ < 1 and the other for reading beam which introduces $\delta$ > 1. Reading beam can read open's/short's of a specific net among many test nets, simultaneously discharging during the reading process for the next step, by removing its voltage contrast. The experimental results of testing the copper signal lines on glass-epoxy substrates showed that the state of open's/short's had generated the brightness contrast due to the voltage contrast on the surface of copper conductor line, when the net had charged with charging electron beams of 7KV accelerating voltages and then read with scanning reading electron beams of 2KV accelerating voltages in 10 seconds. The experimental results with Au pads of a IC die and Au plated Cu pads of BGA substrates provided the simple test method of circuit lines with 7KV charging electron beam and 2KV reading beam. Thus the characterization method showed that we can test open and short circuits of the net nondestructively by using dual potential electron beams with one SEM gun.

  • PDF

Dispersibility, Electrical Property of Nano-Composite by Solution Mixing Method (용액혼합법에 따른 나노복합재료 분산성 및 전기적 특성)

  • Yang, Hoon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.73-74
    • /
    • 2008
  • In this paper, we have investigated dispersibility, volume resistivity of nano-composite by solution mixing method. Dispersibility measured by FE-SEM(Field Emission Scanning Electron Microscope. And volume resistivity measured by ASTM D991. To expect interaction used dual filler system. But, dual filler system had influence on polymer complex. So, polymer chain mobility doesn't resist.

  • PDF

Effect of surface treatment and luting agent type on shear bond strength of titanium to ceramic materials

  • Karaokutan, Isil;Ozel, Gulsum Sayin
    • The Journal of Advanced Prosthodontics
    • /
    • v.14 no.2
    • /
    • pp.78-87
    • /
    • 2022
  • PURPOSE. This study aimed to compare the effect of different surface treatments and luting agent types on the shear bond strength of two ceramics to commercially pure titanium (Cp Ti). MATERIALS AND METHODS. A total of 160 Cp Ti specimens were divided into 4 subgroups (n = 40) according to surface treatments received (control, 50 ㎛ airborne-particle abrasion, 110 ㎛ airborne-particle abrasion, and tribochemical coating). The cementation surfaces of titanium and all-ceramic specimens were treated with a universal primer. Two cubic all-ceramic discs (lithium disilicate ceramic (LDC) and zirconia-reinforced lithium silicate ceramic (ZLC)) were cemented to titanium using two types of resin-based luting agents: self-cure and dual-cure (n = 10). After cementation, all specimens were subjected to 5000 cycles of thermal aging. A shear bond strength (SBS) test was conducted, and the failure mode was determined using a scanning electron microscope. Data were analyzed using three-way ANOVA, and the Tukey-HSD test was used for post hoc comparisons (P < .05). RESULTS. Significant differences were found among the groups based on surface treatment, resin-based luting agent, and ceramic type (P < .05). Among the surface treatments, 50 ㎛ air-abrasion showed the highest SBS, while the control group showed the lowest. SBS was higher for dual-cure resin-based luting agent than self-cure luting agent. ZLC showed better SBS values than LDC. CONCLUSION. The cementation of ZLC with dual-cure resin-based luting agent showed better bonding effectiveness to commercially pure titanium treated with 50 ㎛ airborne-particle abrasion.

A Parallel Mode Confocal System using a Micro-Lens and Pinhole Array in a Dual Microscope Configuration (이중 현미경 구조를 이용한 마이크로 렌즈 및 핀홀 어레이 기반 병렬 공초점 시스템)

  • Bae, Sang Woo;Kim, Min Young;Ko, Kuk Won;Koh, Kyung Chul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.19 no.11
    • /
    • pp.979-983
    • /
    • 2013
  • The three-dimensional measurement method of confocal systems is a spot scanning method which has a high resolution and good illumination efficiency. However, conventional confocal systems had a weak point in that it has to perform XY axis scanning to achieve FOV (Field of View) vision through spot scanning. There are some methods to improve this problem involving the use of a galvano mirror [1], pin-hole array, etc. Therefore, in this paper we propose a method to improve a parallel mode confocal system using a micro-lens and pin-hole array in a dual microscope configuration. We made an area scan possible by using a combination MLA (Micro Lens Array) and pin-hole array, and used an objective lens to improve the light transmittance and signal-to-noise ratio. Additionally, we made it possible to change the objective lens so that it is possible to select a lens considering the reflection characteristic of the measuring object and proper magnification. We did an experiment using 5X, 2.3X objective lens, and did a calibration of height using a VLSI calibration target.

Growth Mechanism and Crystal Ordering of Spherulitic Patterns in a Belousov-Zhabotinsky Type Reaction System

  • Yadav, Narendra;Majhi, S.S.;Srivastava, P.K.
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.10
    • /
    • pp.3397-3406
    • /
    • 2012
  • Three types of spherulitic morphologies have been investigated in dual substrate mode of Belousov-Zhabotinsky (BZ) type reaction system. Prior to growth of spherulites, three distinct patterning behaviors have been observed sequentially during the reaction process. Initial and the early-phase of reaction showed the emergence of concentric ring-like wave patterns. A colloidal-state of reaction consists of numerous fine solid particles, which forms primarily some nucleation centers of dendritic characters. The nucleation centers were found to grow in sizes and shapes with the progress of reaction. It leads to growth of dendritic-like spherulitic crystal patterns. The resultant spherulites showed transitions in their morphologies, including sea-weeds and rhythmic spherulitic crystal patterns, by the effects substituted organic substrate and in the higher concentration of bromate-initiator respectively. The branching mechanism and crystal ordering of spherulitic textures were studied with help of optical microscope (OPM) and scanning electron microscope (SEM). Characteristics of crystal phases were also evaluated using X-ray diffraction (XRD) and differential thermal analysis (DTA). Results indicated that the compositions of reactants and crystal orderings were interrelated with morphological transitions of spherulites as illustrated and described.

Dual effect of Low- frequency Electromagnetic Field on Muscle Histopathology of Caspian Sea Cyprinus carpio

  • Samiee, Farzaneh;Samiee, Keivandokht
    • Journal of fish pathology
    • /
    • v.30 no.1
    • /
    • pp.51-61
    • /
    • 2017
  • The effect of electromagnetic field on aquatic organisms has received little attention. In the current study, the effect of 50Hz electromagnetic field on muscle histopathology of Caspian Sea Cyprinus carpio, a species of economic importance, was investigated. A total of 120 healthy fish were used in this study. They were classified randomly in one of two groups as follows: Control or unexposed EMF group and experimental group with 5 different magnetic field intensities (0.1, 1, 3, 5 and 7mT) at 2 different exposure times including 30 and 60 minutes. Fish in the experimental group were exposed only once. Two weeks after exposure, dorsal muscles sectioned transversely, stained and were examined using a light microscope. Histopathologic assessments showed significant difference between control and EMF exposed groups at both 30 min. (p<0.01) and 60 min. (p<0.001) exposure times. We report for the first time that electromagnetic field in interaction with muscular tissue of Cyprinus carpio exhibits a dual effect which depends on the field intensity, and exposure time. At short exposure time (30 min.), EMF stimulates muscle growth process. At longer exposure time (60 min.), EMF can damage muscle tissue and result in muscle necrosis. More research is required to elucidate precise mechanisms involved in muscle hypertrophy and pathologic changes.

Co-existence of Lipoma and Myxopapillary Ependymoma in a Filum Terminale Tumor

  • Choi, Seung-Hyon;Kim, Sang-Jin;Park, Sang-Hoon;Cho, Yong-Jae
    • Journal of Korean Neurosurgical Society
    • /
    • v.39 no.5
    • /
    • pp.378-381
    • /
    • 2006
  • A 65-year-old woman presented with a history of severe lower back pain on forward-flexion for 2 months duration. Magnetic resonance Imaging revealed a high signal mass with a tail on T1-weighted images at the L3 level. A total surgical resection was performed via a posterior approach with the aid of a microscope. Histopathological examination of the tumor revealed two pathological components : lipoma and myxopapillary ependymoma. The presence of dual histological components in one spinal cord tumor is rare. There are no prior reports of both types of cells [adipose and ependymal] grown simultaneously in a single tumor of the filum terminale in the medical literature. We report a unique case of the co-existence of lipoma and myxopapillary ependymoma within the same tumor located at the filum terminale and review related literature.

Improvement of Adhesion Strength of DLC Films on Nitrided Layer Prepared by Linear Ion Source

  • Shin, Chang-Seouk;Kim, Wang-Ryeol;Park, Min-Seok;Jung, Uoo-Chang;Chung, Won-Sub
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.08a
    • /
    • pp.177-179
    • /
    • 2011
  • The purpose of this study is to enhance an adhesion between substrate and Diamond-like Carbon (DLC) film. DLC has many outstanding properties such as low friction, high wear resistance and corrosion resistance. However, it is difficult to achieve enough adhesion because of weak bonding between DLC film and the substrate. For improvement adhesion, a layer between DLC film and the substrate was prepared by dual post plasma. DLC film was deposited on nitrided layer by linear ion source. The composed compound layer between substrate and DLC film was investigated by Glow Discharge Spectrometer (GDS) and Scanning Electron Microscope (SEM). The synthesized bonding structure of DLC film was analyzed using a micro raman spectrometer. Mechanical properties were measured by nano-indentation. In order to clarify the mechanism for improvement in adhesive strength, it was observed by scratch test.

  • PDF

Improved Adhesion of DLC Films by using a Nitriding Layer on AISI H13 Substrate

  • Park, Min-Seok;Kim, Dae-Young;Shin, Chang-Seouk;Kim, Wang Ryeol
    • Journal of the Korean institute of surface engineering
    • /
    • v.54 no.6
    • /
    • pp.307-314
    • /
    • 2021
  • Diamond-like carbon (DLC) is difficult to achieve sufficient adhesion because of weak bonding between DLC film and the substrate. The purpose of this study is to improve the adhesion between substrate and DLC film. DLC film was deposited on AISI H13 using linear ion source. To improve adhesion, the substrate was treated by dual post plasma nitriding. In order to define the mechanism of the improvement in adhesive strength, the gradient layer between substrate and DLC film was analyzed by Glow Discharge Spectrometer (GDS) and Scanning Electron Microscope (SEM). The microstructure of the DLC film was analyzed using a micro Raman spectrometer. Mechanical properties were measured by nano-indentation, micro vickers hardness tester and tribology tester. The characteristic of adhesion was observed by scratch test. The adhesion of the DLC film was enhanced by active screen plasma nitriding layer.

Focused Electrospray Deposition for Matrix-assisted Laser Desorption/Ionization Mass Spectrometry

  • Jeong, Kyung-Hwan;Seo, Jong-Cheol;Yoon, Hye-Joo;Shin, Seung-Koo
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.8
    • /
    • pp.2293-2298
    • /
    • 2010
  • Focused electrospray (FES) deposition method is presented for matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. FES ion optics consists of two cylindrical focusing electrodes capped with a truncated conical electrode through which an electrospray emitter passes along the cylindrical axis. A spray of charged droplets is focused onto a sample well on a MALDI target plate under atmospheric pressure. The shape and size distributions of matrix crystals are visualized by scanning electron microscope and the mass spectra are obtained by time-of-flight mass spectrometry. Angiotensin II, bradykinin, and substance P are used as test samples, while $\alpha$-cyano-4-hydroxycinnamic acid and dihydroxybenzoic acid are employed as matrices. FES of a sample/matrix mixture produces fine crystal grains on a 1-3 mm spot and reproducibly yields the mass spectra with little shot-to-shot and spot-to-spot variations. Although FES greatly stabilizes the signals, the space charge due to matrix ions limits the detection sensitivity of peptides. To avoid the space charge problem, we adopted a dual FES/FES mode, which separately deposits matrix and sample by FES in sequence. The dual FES/FES mode reaches the detection sensitivity of 0.88 amol, enabling ultrasensitive of peptides by homogeneously depositing matrix and sample under atmospheric pressure.