• Title/Summary/Keyword: dual beam

Search Result 280, Processing Time 0.024 seconds

DEVELOPMENT OF 230 GHZ RADIO RECEIVER SYSTEM FOR SRAO

  • Lee, Jung-Won;Kim, Chang-Hee;Kang, Hyunwoo;Lee, Bangwon;Han, Junghwan;Lee, Seok-Ho;Jeong, Il-Gyo;Koo, Bon-Chul;Park, Yong-Sun
    • Journal of The Korean Astronomical Society
    • /
    • v.46 no.6
    • /
    • pp.225-234
    • /
    • 2013
  • We develop a radio receiver system operating at ${\lambda}{\sim}1.3$ mm for the 6 m telescope of Seoul Radio Astronomy Observatory. It consists of a dual polarization receiver, a couple of IF processing units, two FFT spectrometers, and associated software. By adopting sideband-separating superconductor mixers with image band terminated to waveguide load at 4.2 K, we achieve $T_{RX}{\leq}100$ K and $T_{sys}$ less than 150 K at best weather condition over 210-250 GHz frequency range. The intermediate frequency signal of 3.5-4.5 GHz is down converted to 0-1 GHz and fed into the FFT spectrometers. The spectrometer covers 1 GHz bandwidth with a spectral resolution of 61 KHz. Test observations are conducted toward several radio sources to evaluate the performance of the system. Aperture and beam efficiencies measured by observing planets are found to be typically 44 ~ 59% and 47 ~ 61%, respectively over the RF band, which are consistent with those measured at 3 mm band previously.

A Pilot Study on Hip Bone Mineral Densities Estimation from Forearm CBCT images

  • Ko, Hoon;Lee, Chang-Hoon;Jeong, Kwanmoon;Lee, Myeung Su;Nam, Yunyoung;Yoon, Kwon-Ha;Lee, Jinseok
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.6054-6068
    • /
    • 2017
  • In this paper, we defined the relative cross-sectional area of forearm cortical bone and investigated its correlation with hip bone mineral density values of total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle, respectively. Based on the correlations, we established a linear transformation between the relative cross-sectional area of forearm cortical bone and each hip bone BMD. We obtained forearm images using CBCT and hip bone BMDs using dual-energy X-ray absorptiometry (DXA) for 28 subjects. We also investigated the optimal forearm region to provide the strongest correlation coefficient. We used the optimized forearm region to establish each linear transformation to estimate BMD values for total femur, femoral neck, femoral trochanter, femoral inter-trochanter and femoral ward's triangle from the relative cross-sectional area of forearm cortical bone, respectively. We observed the strong correlations with total femur (r=0.889), femoral neck (r=0.924), femoral trochanter (r=0.821), femoral inter-trochanter (r=0.867) and femoral ward's triangle (r=0.895), respectively. The strongest correlation was observed in the forearm mid-shaft regions. Our results suggest that the hip bone BMD values can be simply estimated from forearm CBCT images in a convenient sitting position without X-ray exposure on a hip including genital organs, and may be useful for screening osteoporosis.

Researches on Microstrip Reflectarray Antennas (마이크로스트립 리플렉트어레이 안테나에 관한 연구)

  • Yoon, Young Joong
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.11
    • /
    • pp.937-950
    • /
    • 2015
  • Microstrip reflectarray is an antenna which controls its radiation pattern with a number of reflective elements. Conventionally, the reflectarray has been researched to replace curved reflector antennas. In this paper, design theories of reflectarray is briefly introduced, and research trends of high gain and broadband reflectarrays are reviewed. To improve the gain of the reflectarrays, it is required that the reflection phase errors on the reflectarray surface be minimized. For this purpose, sufficiently wide reflection phase range and low phase sensitivity should be realized with the designed element. For bandwidth improvement, the reflection phase of the element should be linear with the frequency variation. In this paper, various researches to improve the reflection phase characteristics of the element for high gain and broadband reflectarrays, such as multi-layer and single-layer multi-resonant structures, are reviewed. Also, dual-reflectarray configuration for compact antenna design is reviewed. Finally, various applications of reflectarrays such as contoured beam, near-field focusing, and RCS reduction are reviewed.

Acoustic Estimates of Anchovy Biomass along the Tongyoung- Namhae Coast (음향을 이용한 통영 남해 연안 멸치 자원량 추정)

  • Kim, Joo-Il;Yang, Won-Seok;Oh, Taeg-Yun;Seo, Young-Il;Kim, Sung-Tae;Hwang, Doo-Jin;Kim, Eun-Ho;Jeong, Sun-Beom
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.1
    • /
    • pp.61-67
    • /
    • 2008
  • Acoustic technology is commonly used to estimate the biomass and distribution of fisheries resources in coastal areas and the open ocean. Acoustic surveys were conducted on 24-26 May and 20-21 June, 2005, and 15-18 June and 27-30 July, 2006, near the Tongyoung, Geojae, and Namhae anchovy fishing grounds using a dual beam echo sounder. Information was obtained on the distributions of adult and juvenile anchovy (depth and position). We calculated and compared anchovy biomass using simple summation. In this study, all backscatter was attributed to anchovy. We assumed that the average target strength of anchovy was -70 dB and the average body weight was 3 g in May and June 2005, and that the target strength of anchovy was -65 dB and the average body weight was 5 g for pelagic individuals in July 2006. The anchovy biomass in May 2005 was estimated to be 0.147 million tons using the traditional method, while using the summation method, the estimated anchovy biomass was 0.062 million tons in June 2005, 0.21 million tons in June 2006, and in 0.43 million tons in July 2006.

Cost Effective Silica-Based 100 G DP-QPSK Coherent Receiver

  • Lee, Seo-Young;Han, Young-Tak;Kim, Jong-Hoi;Joung, Hyun-Do;Choe, Joong-Seon;Youn, Chun-Ju;Ko, Young-Ho;Kwon, Yong-Hwan
    • ETRI Journal
    • /
    • v.38 no.5
    • /
    • pp.981-987
    • /
    • 2016
  • We present a cost-effective dual polarization quadrature phase-shift coherent receiver module using a silica planar lightwave circuit (PLC) hybrid assembly. Two polarization beam splitters and two $90^{\circ}$ optical hybrids are monolithically integrated in one silica PLC chip with an index contrast of $2%-{\Delta}$. Two four-channel spot-size converter integrated waveguide-photodetector (PD) arrays are bonded on PD carriers for transverse-electric/transverse-magnetic polarization, and butt-coupled to a polished facet of the PLC using a simple chip-to-chip bonding method. Instead of a ceramic sub-mount, a low-cost printed circuit board is applied in the module. A stepped CuW block is used to dissipate the heat generated from trans-impedance amplifiers and to vertically align RF transmission lines. The fabricated coherent receiver shows a 3-dB bandwidth of 26 GHz and a common mode rejection ratio of 16 dB at 22 GHz for a local oscillator optical input. A bit error rate of $8.3{\times}10^{-11}$ is achieved at a 112-Gbps back-to-back transmission with off-line digital signal processing.

A study on the examples and changes of wooden member terms in Yeonggeon-euigwe (영건의궤(營建儀軌)에 실린 목부재용어(木部材用語)의 용례(用例)와 변천(變遷)에 관(關)한 연구(硏究))

  • Kim, Jae-Ung;Lee, Bong-Soo
    • Journal of architectural history
    • /
    • v.17 no.5
    • /
    • pp.71-94
    • /
    • 2008
  • This study examines the examples and changes of wooden member terms in Yeonggeon-euigwe(營建儀軌) in the era of Joseon Dynasty. As a result of examining examples, about 240 wood member terms were found on the basis of phonetic value and examples different from today's term use were also confirmed. Wood member terms were derived in variety and synonym and different style, that is, coexistence or transition of several notations as the term indicating the same member was found. Derivation of detail terms has the characteristic increasing on the basis of morpheme and formation of different notation followed Chinese notation or was caused by complex coinage features like a coined word of Korea by the meaning of a word and borrowed character notation borrowing sound and it is also related to the specificity of that time which had dual language system. The typical examples without different style for long were pillar, rafter, door and window. Examples with active generation and selection of different styles included beam, capital and bracket-system terms. Different styles were caused by the combination of several notations including borrowed character in the process of Chinese character notation borrowing sound, Korean unique character emphasizing and limiting combination of 木 (wood) with side of character and Chinese. Period showing remarkable change of example notation was the compilation of ${\ll}$the Hwa-Sung-Sung-Euk-Eui-Gue${\gg}$ 華城城役儀軌. ${\ll}$the Hwa-Sung-Sung-Euk-Eui-Gue${\gg}$ is the representative type uigwe made by printed type not by handicraft. Printing by type accompanies unification of the shape of a character necessarily and it was considered that it resulted in the unification of character of different style, the number of strokes and minute difference of strokes, and it was interpreted that common use of intentional notation with the unification of the shape of a character was achieved.

  • PDF

Design and Fabrication of Dual Band Antenna using Skeleton Slot Radiator (Skeleton Slot 구조를 이용한 이중 대역 안테나의 설계 및 제작)

  • 김운필;이범선
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2002
  • In this paper we design and fabricate the Skeleton slot antenna which operates dually in GSM 900 and 1800 bands. Its simulation results are also compared with the measured ones. The original Skeleton slot antennas had the problems of unsatisfactory VSWR characteristics and considerably changing horizontal radiation patterns at high frequencies, but the proposed design improves these problems using multi-path feeding network and folding structure. The size of the radiator is 154 $\times$ 106(mm), and its height is 33(mm), and the reflector of 190$\times$190(mm) is used. The material of the radiator and reflector is 1mm-thick aluminum. Using NTC process reduces the mass production cost significantly. The measured return losses are 13.7 % at 900 MHz band and 16.4 % at 1800 MHz band, respectively. The horizontal radiation beam width is stable within $\pm$ 1$^{\circ}$ at both frequency bands.

Experiment of proof-of-principle on prompt gamma-positron emission tomography (PG-PET) system for in-vivo dose distribution verification in proton therapy

  • Bo-Wi Cheon ;Hyun Cheol Lee;Sei Hwan You;Hee Seo ;Chul Hee Min ;Hyun Joon Choi
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2018-2025
    • /
    • 2023
  • In our previous study, we proposed an integrated PG-PET-based imaging method to increase the prediction accuracy for patient dose distributions. The purpose of the present study is to experimentally validate the feasibility of the PG-PET system. Based on the detector geometry optimized in the previous study, we constructed a dual-head PG-PET system consisting of a 16 × 16 GAGG scintillator and KETEK SiPM arrays, BaSO4 reflectors, and an 8 × 8 parallel-hole tungsten collimator. The performance of this system as equipped with a proof of principle, we measured the PG and positron emission (PE) distributions from a 3 × 6 × 10 cm3 PMMA phantom for a 45 MeV proton beam. The measured depth was about 17 mm and the expected depth was 16 mm in the computation simulation under the same conditions as the measurements. In the comparison result, we can find a 1 mm difference between computation simulation and measurement. In this study, our results show the feasibility of the PG-PET system for in-vivo range verification. However, further study should be followed with the consideration of the typical measurement conditions in the clinic application.

Dynamic Analysis of Tie-rod-fastened Rotor Considering Elastoplastic Deformation (탄소성 변형을 고려한 타이로드 고정 회전체의 동역학 해석)

  • Dongchan Seo;Kyung-Heui Kim;Dohoon Lee;Bora Lee;Junho Suh
    • Tribology and Lubricants
    • /
    • v.40 no.1
    • /
    • pp.8-16
    • /
    • 2024
  • This study conducts numerical modeling and eigen-analysis of a rod-fastened rotor, which is mainly used in aircraft gas turbine engines in which multiple disks are in contact through curvic coupling. Nayak's theory is adopted to calculate surface parameters measured from the tooth profile of the curvic coupling gear. Surface parameters are important design parameters for predicting the stiffness between contact surfaces. Based on the calculated surface parameters, elastoplastic contact analysis is performed according to the interference between two surfaces based on the Greenwood-Williamson model. The equivalent bending stiffness is predicted based on the shape and elastoplastic contact stiffness of the curvic coupling. An equation of motion of the rod-fastened rotor, including the bending stiffness of the curvic coupling, is developed. Methods for applying the bending stiffness of a curvic coupling to the equation of motion and for modeling the equation of motion of a rotor that includes both inner and outer rotors are introduced. Rotordynamic analysis is performed through one-dimensional finite element analysis, and each element is modeled based on Timoshenko beam theory. Changes in bending stiffness and the resultant critical speed change in accordance with the rod fastening force are predicted, and the corresponding mode shapes are analyzed.

The Evaluation of Reconstructed Images in 3D OSEM According to Iteration and Subset Number (3D OSEM 재구성 법에서 반복연산(Iteration) 횟수와 부분집합(Subset) 개수 변경에 따른 영상의 질 평가)

  • Kim, Dong-Seok;Kim, Seong-Hwan;Shim, Dong-Oh;Yoo, Hee-Jae
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.15 no.1
    • /
    • pp.17-24
    • /
    • 2011
  • Purpose: Presently in the nuclear medicine field, the high-speed image reconstruction algorithm like the OSEM algorithm is widely used as the alternative of the filtered back projection method due to the rapid development and application of the digital computer. There is no to relate and if it applies the optimal parameter be clearly determined. In this research, the quality change of the Jaszczak phantom experiment and brain SPECT patient data according to the iteration times and subset number change try to be been put through and analyzed in 3D OSEM reconstruction method of applying 3D beam modeling. Materials and Methods: Patient data from August, 2010 studied and analyzed against 5 patients implementing the brain SPECT until september, 2010 in the nuclear medicine department of ASAN medical center. The phantom image used the mixed Jaszczak phantom equally and obtained the water and 99mTc (500 MBq) in the dual head gamma camera Symbia T2 of Siemens. When reconstructing each image altogether with patient data and phantom data, we changed iteration number as 1, 4, 8, 12, 24 and 30 times and subset number as 2, 4, 8, 16 and 32 times. We reconstructed in reconstructed each image, the variation coefficient for guessing about noise of images and image contrast, FWHM were produced and compared. Results: In patients and phantom experiment data, a contrast and spatial resolution of an image showed the tendency to increase linearly altogether according to the increment of the iteration times and subset number but the variation coefficient did not show the tendency to be improved according to the increase of two parameters. In the comparison according to the scan time, the image contrast and FWHM showed altogether the result of being linearly improved according to the iteration times and subset number increase in projection per 10, 20 and 30 second image but the variation coefficient did not show the tendency to be improved. Conclusion: The linear relationship of the image contrast improved in 3D OSEM reconstruction method image of applying 3D beam modeling through this experiment like the existing 1D and 2D OSEM reconfiguration method according to the iteration times and subset number increase could be confirmed. However, this is simple phantom experiment and the result of obtaining by the some patients limited range and the various variables can be existed. So for generalizing this based on this results of this experiment, there is the excessiveness and the evaluation about 3D OSEM reconfiguration method should be additionally made through experiments after this.

  • PDF