• 제목/요약/키워드: dual CT

검색결과 144건 처리시간 0.03초

Photon-Counting Detector CT: Key Points Radiologists Should Know

  • Andrea Esquivel;Andrea Ferrero;Achille Mileto;Francis Baffour;Kelly Horst;Prabhakar Shantha Rajiah;Akitoshi Inoue;Shuai Leng;Cynthia McCollough;Joel G. Fletcher
    • Korean Journal of Radiology
    • /
    • 제23권9호
    • /
    • pp.854-865
    • /
    • 2022
  • Photon-counting detector (PCD) CT is a new CT technology utilizing a direct conversion X-ray detector, where incident X-ray photon energies are directly recorded as electronical signals. The design of the photon-counting detector itself facilitates improvements in spatial resolution (via smaller detector pixel design) and iodine signal (via count weighting) while still permitting multi-energy imaging. PCD-CT can eliminate electronic noise and reduce artifacts due to the use of energy thresholds. Improved dose efficiency is important for low dose CT and pediatric imaging. The ultra-high spatial resolution of PCD-CT design permits lower dose scanning for all body regions and is particularly helpful in identifying important imaging findings in thoracic and musculoskeletal CT. Improved iodine signal may be helpful for low contrast tasks in abdominal imaging. Virtual monoenergetic images and material classification will assist with numerous diagnostic tasks in abdominal, musculoskeletal, and cardiovascular imaging. Dual-source PCD-CT permits multi-energy CT images of the heart and coronary arteries at high temporal resolution. In this special review article, we review the clinical benefits of this technology across a wide variety of radiological subspecialties.

Duplicated Vertebral Artery : Literature Review and Clinical Significance

  • Kim, Myoung Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제61권1호
    • /
    • pp.28-34
    • /
    • 2018
  • Objective : Duplication of the vertebral artery (VA) is a rare vascular variant. This paper describes the anatomy and embryological development of duplicated VAs and reviews the clinical significance. Methods : Computed tomography (CT) angiography was performed in 3386 patients (1880 females, 1506 males) between March 2014 and November 2015. We defined duplication of the VA as a condition in which the VA has two origins that fused at different levels of the neck. Results : Ten of the 3386 patients (0.295%) who received CT angiography had a dual origin of the VA; three on the left side, and seven on the right side. In all seven with right dual origin of the VA, both limbs of the VA origin originated from the right subclavian artery. In all three patients with left dual origin of the VA, both limbs of the VA originated from the left subclavian artery and aortic arch. In all 10 patients, the medial limb of the duplicated VA was located posteriorly and medially to the common carotid artery (CCA) and anteriorly and laterally to the vertebral transverse foramen. In two patients, the medial limb of the duplicated VA was located in close proximity to the CCA. In another two patients, the medial limb of the duplicated VA was located in close proximity to the CCA, carotid bifurcation, and proximal internal carotid artery. Conclusion : Although duplication of the VA is asymptomatic in most patients, clinicians should consider this anomaly during diagnosis and treatment.

위암환자의 술 전 병기 결정에서 PET-CT의 유용성 (Effectiveness of Positron Emission Tomography in the Pre-operative Staging of Gastric Cancer)

  • 박신영;배정민;김세원;김상운;송선교
    • Journal of Gastric Cancer
    • /
    • 제9권3호
    • /
    • pp.110-116
    • /
    • 2009
  • 목적: 위암환자의 수술 전 병기 결정에 있어서 PET의 유용성을 알아보기 위해 본 연구를 시행하였다. 대상 및 방법: 2006년 2월부터 2008년 8월까지 본원에서 위암으로 진단받고 수술 전 병기 결정을 위해 복부 컴퓨터 단층촬영(CT) 및 PET-CT를 모두 시험한 환자 70명을 대상으로 복부 CT 및 PET-CT 영상 자료에 의한 림프절 전이 판정과 수술 후 병리 조직검사에 의한 림프절 전이판정으로 민감도, 특이도, 양성예측도, 음성예측도 및 정확도를 조사하였고 위암의 형태, 조직학적 분류, 크기 등과 FDG섭취 정도와의 차이 등을 알아보았다. 결과: 조기 위암 23예의 경우 복부 CT에서 병변이 진단된 경우는 4명(17.4%), PET-CT에서는 12명(52.1%)이었으며, 진행 위암 47예의 경우 CT에서 26명(56.5%), PET-CT에서 45명(95.7%)으로 PET-CT에서 진단율이 높게 나타났다. 병변의 크기에 따른 분류에서도 복부 CT보다 PET-CT에서 진단율이 높은 것으로 나타났으며, 조기 위암의 경우 진행 위암에 비해 FDG 섭취 정도가 낮았지만 3 cm 이상의 조기 위암의 경우 3 cm 미만의 조기 위암에 비해 FDG가 섭취되는 경우가 더 많았다. CT에서 림프절 병기 결정의 민감도는 40.0%, 특이도는 85.7%, 양성예측도는 85.7%, 그리고 음성예측도는 40.0%였으며, PET-CT에서는 각각 55.6%, 81.0%, 86.2%, 45.9%였다. PET-CT를 통해서만 발견된 전이 병소는 1예(간전이)였으며, 중복암은 직장암 1예와 췌장암 1예가 있었다. 또한 세포조직형에 따른 분류에서도 분화영, 미분화형 모두 PET-CT에서 진단율이 높은 것으로 나타났다. 결론: CT에 비해 PET-CT에서 원발 병소의 진단, 림프절 전이 모두 진단율이 높은 것으로 나타났으며 PET-CT는 전이 병소와 중복암의 발견 등 다른 영상 진단법에 비하여 유리한 점이 있다.

  • PDF

CT의 MAR알고리즘 적용 시 의료용 금속 물질별 인공물 감소율 분석 (Analysis of the artifact reduction rate for the types of medical metals in CT with MAR algorithm)

  • 김현주;윤준
    • 한국산학기술학회논문지
    • /
    • 제17권9호
    • /
    • pp.655-662
    • /
    • 2016
  • 의료용 CT영상에서 영상의 화질 저하의 원인으로 인공물을 유발의 원인인 다양한 금속성분의 의료용 재료를 이용하여, 듀얼에너지 CT의 MAR 알고리즘적용 전, 후 영상의 CT value값을 비교 측정하고, 정량적 분석을 통해 MAR Algorithm 적용의 유용성을 알아보았다. 그 결과 MAR 알고리즘 적용 시 대부분의 의료용 금속 물질에서 인공물 감소효과가 있었다(P<0.05). 특히, 의료용 금속물질 중 Stainless합금(78.1% 감소)과 백금소재인 GDC coil(76.1% 감소)처럼 상대적으로 밀도가 높은 의료용 금속물질에서 인공물 감소효과가 높았다(P<0.05). 또한, 인공물 형태에 따른 인공물 감소정도를 정량적 분석을 통해 알아보았다. 그 결과는 MAR 알고리즘 적용 시 Stainless합금과 Titanium합금의 경우 Black hole artifact형태에서 인공물 감소효과가 매우 우수하였고(P<0.05), 백금소재인 GDC coil의 경우는 White streak artifact형태에서 인공물 감소효과가 매우 우수하였다(P<0.05). 향후 의료용 금속 물질 삽입 수술 환자의 경우 듀얼 에너지 CT장비의 MAR알고리즘을 적용하여 CT검사를 시행한다면 금속물질에 기인한 인공물 유발을 감소시켜 보다 뛰어난 화질의 영상정보를 제공할 수 있을 것으로 사료된다.

대장암의 간 전이 진단: 이중시기 CT, Mn-DPDP 조영증강 MRI, 그리고 CT-MRI 종합 판독의 비교 (Preoperative Detection of Hepatic Metastases from the colorectal Cancers: Comparison of Dual-phase CT scan, Mn-DPDP enhanced MRI, and combination of CT and MRI)

  • 신경민;김종열;최규석;김혜정;이종민;장용민;김용선;강덕식;염헌규
    • Investigative Magnetic Resonance Imaging
    • /
    • 제9권2호
    • /
    • pp.109-116
    • /
    • 2005
  • 목적 : 대장암의 간 전이 진단에서 CT와 MRI 단독 판독과 CT-MRI 종합 판독의 성적을 비교하여 부가적인 Mn-DPDP 조영증강 MRI의 유용성에 대해 알아보고자 하였다. 대상 및 방법 : 53명의 대장암 환자를 대상으로 하였으며 이들은 수술전 이중시기 CT에서 전이성 병소가 의심되거나 혈청 CEA(carcinoembryonic antigen) 수치가 10 ng/mL 로 증가하여 부가적인 Mn-DPDP 조영증강 MRI를 시행하였다. 두 명의 방사선과 의사가 독립적으로 15 일 간격을 두고 CT 단독 판독, MRI 단독 판독, CT와 MRI를 종합하여 판독하였다. 각 병변의 크기, 위치, 악성 유무를 평가하였으며 크기에 따라 1 cm 미만(A 그룹), 1 cm 에서 2 cm 미만(B 그룹), 2 cm 이상(C 그룹)의 세 그룹으로 분류하였다. ROC 곡선을 이용하여 진단적 정확도를 비교하였으며 발견율과 위양성율을 구하여 통계적 유의성을 검증하였다. 결과 : A 그룹에서 CT와 MRI를 종합하여 판독한 경우는 CT, MRI를 단독으로 판독한 경우와 비교하여 병변의 발견율이 유의하게 높았다 (82%, p=0.036). B그룹에서는 CT와 MRI를 종합하여 판독한 경우 CT를 단독으로 판독한 경우와 비교하여 Az 값이 유의하게 낮았으며(<1 cm, p=0.034; 1-2 cm, p=0.045) MRI 단독 판독과 비교하여서는 유의한 차이를 보이지 않았다. 위양성율에 있어서는 CT 단독 판독의 경우, CT와 MRI의 종합 판독과 비교하여 A그룹에서 유의하게 높은 결과를 보였다 (28 %, p=0.023). 결론 : 대장암 환자에서 병기결정에 있어서 일반적으로 행해지는 나선형 CT 외에 부가적 Mn-DPDP 조영증강 MRI는 2 cm 미만의 간 병변의 감별에 있어 유용하며, 특히 1cm 미만의 작은 간 전이 발견에 있어서는 CT 또는 MRI 단독 판독의 경우보다 발견율을 높일 수 있어서 유용할 것으로 생각된다.

  • PDF

Dual-phase-lag model on microstretch thermoelastic medium with diffusion under the influence of gravity and laser pulse

  • Othman, Mohamed I.A.;Abd-Elaziz, Elsayed M.;Mohamed, Ibrahim E.A.
    • Structural Engineering and Mechanics
    • /
    • 제75권2호
    • /
    • pp.133-144
    • /
    • 2020
  • This investigation is to study the effect of gravitational field and diffusion on a microstretch thermoelastic medium heating by a non-Gaussian laser beam. The problem was studied in the context of the dual-phase-lag model. The normal mode analysis is used to solve the problem to obtain the exact expressions for the non-dimensional displacement components, the micro-rotation, the stresses, and the temperature distribution. The effect of time parameter, heat flux parameter and gravity response of three theories of thermoelasticity i.e. dual-phase-lag model (DPL), Lord and Shulman theory (L-S) and coupled theory (CT) on these quantities have been depicted graphically for a particular model.

SPECT/CT 영상에서 에너지창 기반 산란보정과 CT 기반 산란보정 방법의 정량적 정확성 비교 (The Comparison of Quantitative Accuracy between Energy Window-Based and CT-Based Scatter Correction Method in SPECT/CT Images)

  • 김지현;이주영
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제45권2호
    • /
    • pp.135-143
    • /
    • 2022
  • In SPECT image, scatter count is the cause of quantitative count error and image quality degradation. This study is to evaluate the accuracy of CT based SC(CTSC) and energy window based SC(EWSC) as the comparison with existing Non SC. SPECT/CT images were obtained after filling air in order to acquire a reference image without the influence of scatter count inside the Triple line insert phantom setting hot rod(99mTc 74.0 MBq) in the middle and each SPECT/CT image was obtained each separately after filling water instead of air in order to derive the influence of scatter count under the same conditions. For EWSC, 9 sub-energy windows were set additionally in addition to main energy window(140 keV, 20%) and then, images were acquired at the same time and five types of EWSC including DPW(dual photo-peak window)10%, DEW(dual energy window)20%, TEW(triple energy window)10%, TEW5.0%, TEW2.5% were used. Under the condition without fluctuations in primary count, total count was measured by drawing volume of interest (VOI) in the images of the two conditions and then, the ratio of scatter count of total counts was calculated as percent scatter fraction(%SF) and the count error with image filled with water was evaluated with percent normalized mean-square error(%NMSE) based on the image filled with air. Based on the image filled with air, %SF of images filled with water to which each SC method was applied is non scatter correction(NSC) 37.44, DPW 27.41, DEW 21.84, TEW10% 19.60, TEW5% 17.02, TEW2.5% 14.68, CTSC 5.57 and the scatter counts were removed the most in CTSC and %NMSE is NSC 35.80, DPW 14.28, DEW 7.81, TEW10% 5.94, TEW5% 4.21, TEW2.5% 2.96, CTSC 0.35 and the error in CTSC was found to be the lowest. In SPECT/CT images, the application of each scatter correction method used in the experiment could improve the quantitative count error caused by the influence of scatter count. In particular, CTSC showed the lowest %NMSE(=0.35) compared to existing EWSC methods, enabling relatively accurate scatter correction.

CT 영상의 화질개선을 위한 이중트리복합웨이블릿의 적용 (Application of Dual Tree Complex Wavelet for Performance Improvement of CT Images)

  • 최석윤
    • 한국방사선학회논문지
    • /
    • 제13권7호
    • /
    • pp.941-946
    • /
    • 2019
  • 환자의 진단 및 치료를 결정할 때 전산화단층촬영 (computed tomography; CT)은 우수한 해부학 정보를 제공하기 때문에 진단에 큰 도움이 되어 있다. 그에 따른 사용빈도가 증가하고 있으며, 활용 및 응용범위도 확대되어가는 추세이다. 저관전압을 사용해서 CT 검사를 하면 노이즈가 증가한다. 기존의 여러 연구에서는 영상재구성법에 대한 노출조건을 조절하는 방법 등을 시도해서 최적의 화질을 찾는 방법을 찾고 있으나 근본적 문제해결은 되지 못한다. 입력 영상의 신호를 유지하고 노이즈만을 최대한 제거하기 위해서 이중 트리웨이블릿 알고리즘을 적용하였다. 실험결과 100kVp, 회전시간 0.5sec의 영상에서 complex oriented 2d 방을 사용 할 경우 노이즈는 8.53에서 4.51로 줄어들었다. 본 연구를 통해서 저관전압 두부 CT에서 발생하는 높은 수준의 노이즈를 최적의 노이즈제거 알고리즘으로 노이즈를 제거하고 환자선 량을 낮출 수 있었다. 본 연구결과를 임상에서 사용 시 저선량의 CT 사용이 가능하고 환자 피폭을 줄일 것으로 판단한다.

두부 CT검사에서의 노이즈 및 화질분석 (Noise and Image Quality Analysis of Brain CT Examination)

  • 최석윤;임인철
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권4호
    • /
    • pp.279-284
    • /
    • 2019
  • The purpose of this study was to find the best protocol for balance of image quality and dose in brain CT scan. Images were acquired using dual-source CT and AAPM water phantom, noise and dose were measured, and effective dose was calculated using computer simulation program ALARA(S/W). In order to determine the ratio of image quality and dose by each protocol, FOM (figure of merits) equation with normalized DLP was presented and the result was calculated. judged that the ratio of image quality and dose was excellent when the FOM maximized. Experimental results showed that protocol No. 21(120 kVp, 10 mm, 1.5 pitch) was the best, the organ with the highest effective dose was the brain(33.61 mGy). Among organs with high radiosensitivity, the thyroid gland was 0.78 mGy and breast 0.05 mGy. In conclusion, the optimal parameters and the organ dose in the protocol were also presented from the experiment, It may be helpful to clinicians who want to know the protocol about the optimum state of image quality and dose.

이중 에너지 조사 방식의 장비별 골밀도 측정의 정량적 비교 분석: CT vs DEXA 비교 (Quantitative Analysis of Bone Mineral Measurements in Different Types of Dual-energy Absorptiometry Systems: Comparison of CT vs DEXA)

  • 김명성
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제40권2호
    • /
    • pp.311-316
    • /
    • 2017
  • 골다공증 검사의 표준검사법은 이중 에너지 X선 흡수율(DEXA) 차이를 이용한 방식이고, 임상에서는 유사한 방식의 이중 에너지 X선 전산화단층영상장치(DECT)가 사용되고 있다. 본 논문의 목적은 기존 방식의 DEXA와 DECT 장비를 활용하였을 때 골밀도 차이를 확인하고 DECT 활용의 유용성을 알아보고자 한다. 기존 방식의 DEXA (QDR 4500W, Hologic)와 DECT (750 HD, GE Healthcare system) 장비를 이용하여 동일한 부위의 허리척추 팬텀 대상으로 검사 시행과 측정을 하였고, 1개월 내 기존 DEXA와 DECT 검사를 동일하게 허리 척추 검사를 시행한 환자 50명을 대상으로 골밀도를 측정 분석하였다. 허리척추 팬텀 대상 골밀도 측정 결과 두 영상장비 간에 통계적으로 높은 상관성(r=0.93, p<0.05)을 나타냈고, 사람을 대상으로 하였을 때도 비교적 높은 상관성(r=0.635, p<0.05; ${\tau}=0.46$, p<0.05)을 나타냈다. DECT를 이용한 골다공증 검사는 일반적으로 시행한 CT 영상 정보를 추가로 분석하여 골밀도 값을 얻는 것으로 추가적인 방사선 노출 없이 유용한 골밀도 정보를 제공해줄 수 있다는 유용성이 있다.