• Title/Summary/Keyword: drying shrinkage cracks

Search Result 79, Processing Time 0.611 seconds

Crack Characteristics of Soil Concrete Using Volcaniclastic and the Crack Repair Method (화산쇄설물을 사용한 소일콘크리트의 균열특성과 보수방법에 관한 연구)

  • Hong, Chong-Hyun
    • Journal of Environmental Science International
    • /
    • v.19 no.6
    • /
    • pp.737-746
    • /
    • 2010
  • Restraint to drying shrinkage is the most common cause of concrete cracking. In many applications, drying shrinkage cracks are inevitable. In this paper, the surface cracks of soil concrete caused by drying shrinkage were considered to become an one of concrete textures. So, laboratory shrinkage tests were conducted and the results were applied to the field applications. The study results were summarized as follows; First, the use of vinyl sheets and concrete polymers helped to control the concrete cracking. Second, crack propagation usually started at the interfaces of soil concrete slabs and the cracks grew to the inner slabs. Third, surface cracks of soil concrete slabs could be an one of good concrete textures

An Experimental Study on the Shrinkage Properties of Ultra-Low Shrinkage Concrete (초 저수축 콘크리트의 수축특성에 관한 실험적 연구)

  • Seo, Tae-Seok;Kim, Kang-Min;Lee, Hyun-Seunh
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.148-149
    • /
    • 2021
  • In Japan, ultra-low shrinkage concrete has been developed and commercialized to control drying shrinkage cracks to the limit. However, in the case of South Korea, the study on this technology has not yet been conducted in earnest. Therefore, the study was conducted for the development of ultra-low shrinkage concrete to control the drying shrinkage crack of concrete to the limit, and in this study, after determining the mixture of ultra-low shrinkage concrete, a wall type mock-up specimen was produced to observe the shrinkage behavior of ultra-low shrinkage concrete.

  • PDF

A Parametric Study on the Reason and Control of Crack during the Construction of Pier in Urban Transit (도시철도 교각의 시공중 균열발생 원인과 제어방안을 위한 매개변수 연구)

  • Park, Seong-Kyu
    • Journal of the Korean Society for Railway
    • /
    • v.14 no.6
    • /
    • pp.555-561
    • /
    • 2011
  • This paper is designed to propose methods to both analyze and control the reasons for cracks appearing during the construction of piers. For this aim, a numerical analysis was performed to identify the properties of crack which resulted from heat of hydration and differential drying shrinkage with the key influence factors considered. The results show that the thermal cracks occurred within a few days, and the drying shrinkage cracks within a few weeks. Meanwhile, settlement shrinkage cracks occurred within a few hours. Discussing the control methods based on the time of the cracks appearing, quality control, reduction of the unit quantity of cement, and the preservation of moisture on the surface are proposed as the realistic and effective methods for preventing settlement cracks, thermal cracks, and drying shrinkage cracks respectively.

Study on Prediction of Drying Shrinkage of Concrete using Shrinkage Reducing Agent (수축저감제를 사용한 콘크리트의 건조수축 예측에 관한 연구)

  • Seo, Tae-Seok;Choi, Hoon-Jae
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.4
    • /
    • pp.297-303
    • /
    • 2016
  • Shrinkage Reducing Agent(SRA) was developed in order to control drying shrinkage cracks in concrete, and the use of SRA is increasing since it can control drying shrinkage cracks and improve the quality of concrete structures. Although there are many types of prediction equations of drying shrinkage strain, there is no prediction method which can consider the effect of SRA up to the present. Therefore, it is impossible to predict the tensile stress generated by drying shrinkage of SRA concrete, and to investigate the quantitative serviceability limit state of SRA concrete. In this study, the drying shrinkage of SRA concrete was investigated by experiment and analysis in order to suggest the predictability of drying shrinkage of SRA concrete. As a result, AIJ model, ACI model, GL2000 model showed there was a correlation between the predicted values and the experimental values within the error range of ${\pm}10%$. However, CEB-FIP model and B3 model underestimated the experimental values.

An Experimental Study on the Reduction of Drying and Autogenous Shrinkage of High Performance Concrete Using CSA Expansive Additives and Inorganic Admixtures (CSA계 팽창재 및 무기질 환화재를 이용한 고성능 콘크리트의 건조수축 및 자기수축 저감에 관한 실험 연구)

  • 홍상희;전병채;송명신;한천구;반호용
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1998.10a
    • /
    • pp.386-391
    • /
    • 1998
  • Recently, high performance concrete developed has a good quality at fresh and hardened state, but high binder contents results in spending much money on manufacturing and many cracks by drying and autogenous shrinkage. Therefore, in this paper, not only prevention of cracks caused by drying and autogenous shrinkage, but improvement of quality and accmplishment of economy by applying F.A(fly ash), S.F(silica fume) and CSA(calcium sulfa aluminate) expansive additives as an inorganic admixtures in W/B 35% are discussed. According to the experimental results, when 5% of CSA Expansive additives and 15:5 (F.A:S.F)are replaced at unit cement content, high performance concrete with both good compensation of drying and autogenous shrinkage at hardened state is accomplished.

  • PDF

Reduction of Drying Shrinkage Cracking of Box Culvert for Power Transmission with Shrinkage Reducing Agent (수축저감제 혼입에 따른 전력구 박스구조물의 건조수축균열 저감)

  • Woo, Sang-Kyun;Kim, Ki-Jung;Lee, Yun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.20 no.5
    • /
    • pp.102-108
    • /
    • 2016
  • The purpose of this study is to examine the reduction effect of shrinkage reducing agent for drying shrinkage induced cracking and suggest the method of controlling the cracking in concrete box culvert for power transmission. Based on drying shrinkage cracking mechanism, it is necessary to perform the numerical analysis, which involves shrinkage reducing effect of shrinkage reducing agent. From the numerical results, it is found that cracking behavior for longitudinal direction and transverse direction due to differential drying shrinkage of box culvert can occur and the experimental observation of concrete cracks support the numerical predictions. The shrinkage reducing agent reduced the concrete cracking by 40~50%, which shows the methodology of controlling of drying shrinkage cracks in box culverts in real construction site.

Prediction of Drying Shrinkage Behavior of Half PC Slab (Half PC slab의 건조수축 거동 예측)

  • Seo, Tae-Seok;Choi, Hoon-Jae
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2016.10a
    • /
    • pp.7-8
    • /
    • 2016
  • The use of half PC slab is increasing to shorten construction period. Because the drying shrinkage of topping concrete is restrained by PC slab, the tensile stress is generated at the topping concrete and the cracks can be occurred at the topping concrete due to drying shrinkage. Therefore, it is important to predict the tensile strain of half PC slab due to drying shrinkage to improve the quality of half PC slab. However, there is no studies on prediction of shrinkage behavior of half PC slab yet. Therefore, in this study, half PC slab was made, and the predictability of tensile strain generated at half PC slab due to drying shrinkage was investigated. The step by step method considering creep was used to estimate the tensile strain of half PC slab. In result, good agreement was obtained between the analytical and experimental values.

  • PDF

A Study on the Effect of the Shrinkage Strip on Shrinkage and Thermal Change of Concrete (건조수축 및 온도영향에 대한 건조수축대의 효과 연구)

  • 김록배;김욱종;이도범;이운세
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.251-256
    • /
    • 2001
  • Shrinkage during the curing and drying of concrete is unavoidable and results in many cracks. Shrinkage strips reduce effectively shrinkage stresses and minimize shrinkage cracks by being left open for a certain time during construction allow a significant part of the shrinkage to occur without inducing stresses. This study verifies the effectiveness of shrinkage strips and provides the guide for construction of such strips.

  • PDF

A Study on the Effect of the Shrinkage Strip on Shrinkage and Thermal Change of Concrete in the Underground Parking Structure (공동주택 지하주차장의 건조수축 및 온도영향에 대한 수축대의 효과 연구)

  • 김록배;김욱종;이도범;이운세
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.827-832
    • /
    • 2001
  • Shrinkage during the curing and drying of concrete is unavoidable and results in many cracks. Shrinkage strips reduce effectively shrinkage stresses and minimize shrinkage cracks by being left open for a certain time during construction to allow a significant part of the shrinkage to occur without inducing stresses. This study verifies the effectiveness of shrinkage strips and provides the guide for construction of such strips.

  • PDF

Calculation of Crack Width of the Top Flange of PSC Box Girder Bridge Considering Restraint Drying Shrinkage (구속 건조수축을 고려한 PSC BOX 거더교 상부플랜지 균열폭 산정)

  • Young-Ho Ku;Sang-Mook Han
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.27 no.3
    • /
    • pp.30-37
    • /
    • 2023
  • The PSCB girder bridge is a closed cross-section in which the top and bottom flanges and the web are integrated, and the structural characteristics are generally different from the bridges in which the girder and the floor plate are separated, so a maintenance plan that reflects the characteristics of the PSCB girder bridge is required. As a result of analyzing damage types by collecting detailed safety diagnosis reports of highway PSCB girder bridges, most of the deterioration and damage occurring during use is concentrated on the top flange. In particular, cracks in the bridge direction on the underside of the top flange occurred in about 70 % of the PSCB girder bridges to be analyzed, and these cracks were judged to be caused by indirect loads such as heat of hydration and drying shrinkage rather than structural cracks caused by external loads. In order to improve durability and reduce maintenance costs of PSCB girder bridges in use, it is necessary to control restraint drying shrinkage cracks from the design stage. Therefore, in this paper, the cracks caused by drying shrinkage under restraint, which is the main cause of cracks under the flanges of the top part of the PSCB girder bridge, were directly calculated using the Gilbert Model, and the influencing factors such as the amount of reinforcing bars, diameter and spacing of reinforcing bars were analyzed. As a result of the analysis, it was found that the crack width caused by restraint drying shrinkage exceeded the allowable crack width of 0.2 mm for reinforcing bars with a reinforcing bar ratio of 0.01 or less based on the H16 reinforcing bar and a reinforcing bar with a diameter greater than H19 based on the reinforcing bar ratio of 0.01. Finally, based on the results of the crack width review, a method for controlling the crack width of the top flange of the PSCB girder bridge was proposed.