• Title/Summary/Keyword: dry eye

Search Result 188, Processing Time 0.031 seconds

Morphological Development of Larvae and Juveniles of the Marbled sole, Limanda yokohamae (문치가자미 (Limanda yokohamae) 자치어(仔稚魚)의 형태발달)

  • Han, Kyeong-Ho;Park, Joon-Taek;Jin, Dong-Soo;Jang, Sun-Ik;Joung, Hyun-Ho;Cho, Jae-Kwon
    • Korean Journal of Ichthyology
    • /
    • v.13 no.3
    • /
    • pp.161-165
    • /
    • 2001
  • Artificial fertilization (dry method) of mature right-eye flounder, Limanda yokohamae (female : 25.1~30.4 cm in total length (TL), male : 24.5~28.5 cm in TL), obtained from the fish market in Dolsan-do, Yosu was performed in the Fisheries Exhibition. Hatched larvae and juveniles were reared to describe their morphological development. Newly hached larvae attained 3.13~3.42 mm in TL. Their eyes were yellowish brown and their mouth and anus were not yet opened. Three to six days after hatching the larvae attained 3.35~4.61 mm in TL. Their mouth and anus were open and the yolk sac was almost absorbed. Feeding activity increased as the mouth became larger. At 25 days, the larvae attained 5.47~5.91 mm in TL. The caudal notocord was flexed $45^{\circ}$ upward. At 35 days, the larvae attained 6.83~7.60 mm in TL. Rays of the dorsal and anal fins were formed, and the left eye was moved slightly to the right side of the head. At 55 days, the juveniles attained 9.38~11.73 mm in TL. The left eye was moved completely onto the right side. All of the fins had complete set of the fin rays, and the juveniles spent most of the time on the bottom resting on their blind side (D. 68~70 : A. 50~52 : P. 11: V. 6 : C. 18~19).

  • PDF

Effects of feeding system on growth performance, plasma biochemical components and hormones, and carcass characteristics in Hanwoo steers

  • Chung, Chan Sung;Cho, Woong Ki;Jang, In Seok;Lee, Sung Sill;Moon, Yea Hwang
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.30 no.8
    • /
    • pp.1117-1123
    • /
    • 2017
  • Objective: This study was conducted to compare growth performance, blood components and carcass traits by two feeding systems (concentrate with roughage separately [CON] vs total mixed ration [TMR]) in Hanwoo steers, and to learn the relationship between blood components during fattening or finishing phases and carcass traits in Hanwoo steers. Methods: Sixty steers aged 8 months were allotted to two feeding systems and fed similar amounts of average dry matter and total digestible nutrient throughout whole experimental period according to each feeding program. Steers were weighed monthly, taken blood at the end of growing, fattening and finishing periods, and slaughtered at 30 month of age. Results: Growing performance was higher (p<0.05) in the CON group compared to the TMR group during fattening and finishing periods. The CON group was lower (p<0.05) in blood aspartic acid transaminase, blood urea nitrogen and retinol levels during growing period, but higher in triglyceride and cholesterol levels during fattening and finishing periods compared to the TMR group. The CON group was greater (p<0.05) in rib-eye area, and lighter (p<0.05) red in meat color compared to the TMR group. In the correlation coefficients between blood components of steers and carcass traits, retinol had a negative (p<0.05) correlation with marbling score and rib-eye area. Leptin had a positive (p<0.05) correlation with back fat thickness. Blood cholesterol and triglyceride were positively (p<0.05) correlated with carcass weight and rib-eye area. Conclusion: Growth performance, carcass ribeye area and meat color showed a more desirable result in the CON compared to the TMR in Hanwoo steers. Assessing the accumulated data of carcass traits with blood components including hormones-particularly retinol, cholesterol, triglyceride, and leptin-during the fattening or finishing phases, it may be possible to find a biomarker for determining beef quality in living animals.

Changes in Subjective Discomfort, Blinking Rate, Lens Centration and the Light Transmittance of Lens Induced by Exceeding Use of Daily Disposable Circle Contact Lenses in Dry Eyes (일회용 써클소프트렌즈의 일일 초과착용 시 유발되는 건성안의 자각적 불편감, 순목횟수, 중심안정 및 렌즈 광투과율의 변화)

  • Park, Mijung;Kang, Shin Young;Chang, Jung Iee;Han, Arum;Kim, So Ra
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.2
    • /
    • pp.153-162
    • /
    • 2014
  • Purpose: This study was assessed to investigate the change of subjective and/or objective symptoms and the light transmittance of lens caused by the use longer than recommended wearing time of daily disposable circle contact lenses (circle lens) in dry eyes. Methods: Three daily disposable circle lenses made of etafilcon A, hilafilcon B, and nelfilcon A were applied on 30 dry eyes with smaller tear volume than normal eyes in their twenties free from any eye diseases by when subjects complained any kind of discomfort. On the first and the last days of lens wearing, subjective discomfort, blinking rate, lens centration on corneal surface and visible light transmittance of lens were recorded at every case and compared. Results: The circle lens wearers complained subjective discomfort and quit the lens wearing when they wore the circle lens longer than 10 hours even though there were some difference according to the lens materials of daily disposable circle lens. However, around 20% of dry eyes could wear the circle lens made of non-ionic materials longer than 40 hours. Dry eyes showed most sensitive feeling of subjective discomfort against the circle lens made of etafilcon A among three different lens materials. On the last day of lens wearing, the representative subjective discomforts were irritation, stiffness, dryness and tiredness. When the subjects wore circle lens more than the recommended time, blinking rate was significantly increased about 20~30% regardless of lens materials when it compared with the values right after lens wearing. On the last day of lens wearing, the vertical direction of lens centration was shifted to pupil center however, its distribution in horizontal direction was wide compared with the distribution right after lens wearing. Especially, the centration of etafilcon A lens was unstable. Furthermore, the visible light transmittance of 3 different circle lenses in dry eyes has significantly been reduced around 15% averaged. Conclusions: From these results, it was known that the increase of dryness and stiffness caused by overusage of daily disposable circle lens induced excess irritation and decreased visible light transmittance and caused significant more blinking, which provoked lens decentration. It was also revealed that dry eyes showed sensitive reaction subjectively and objectively against the overusage of circle lens made of high water content/ionic lens material even there were some difference of the degree depending on the individual and the lens material. Thus, this research can be suggested as the basic reference for the education about some unexpected problems and the side effect caused by the wearing of circle lens in dry eyes.

The Study on the Development of Diagnosis Algorithm of Taeeumin Symptomology (태음인(太陰人) 병증(病證) 진단 알고리즘 개발 연구)

  • Shin, Seung-Won;Lee, Eui-Ju;Koh, Byung-Hee;Lee, Jun-Hee
    • Journal of Sasang Constitutional Medicine
    • /
    • v.24 no.4
    • /
    • pp.28-39
    • /
    • 2012
  • Objectives : This study is aimed to develop the algorithm to diagnose Taeeumin's symptomology, by the method of literature research on Sasang Constitutional Medicine. Methods : Applying the sequential differentiations of Taeeumin's symptomology, or exterior-interior disease differentiation, favorable-unfavorable pattern differentiation, and mild-severe-dangerous-urgent pattern differentiation, "Donguisusebowon" and related literatures have been reviewed. Results and Conclusions : 1) 1st step: Taeeumin's exterior pattern and interior pattern are differentiated by the indexes of whole-body cold or heat pattern, sweating, and facial complexion. 2) 2nd step: The favorable pattern of the Taeeumin's exterior disease can be detected by indexes of the existence of fever, generalized pain while the unfavorable one by indexes of the abnormal condition of digestion and feces, and fearful throbbing. The favorable pattern of the Taeeumin's interior disease can be diagnosed based on indexes of eye pain, dry nose, dry throat, and heat symptoms that occur in various parts of the body, while the unfavorable one by indexes of thirsty, urination, feces and specific symptoms which can be induced by dryness. And in the both unfavorable patterns the dark complexion on the faces is revealed. 3) 3rd step: The mild-severe patterns of the favorably exterior disease are differentiated in terms of the condition of fever, while the mild-severe patterns of the favorably interior disease are in differentiated based on whether abnormal symptoms are revealed in the gastrointestinal tract. Both of the unfavorably dangerous-urgent patterns in exterior and interior diseases are differentiated by the symptoms such as tinnitus, dim vision, weakness of legs and back pain, and lack of strength in legs and thighs.

Tracking Performance Test of Polymer Insulator with Salt Solution which is added Surface Active Agent (계면활성제가 첨가된 염수용액에 따른 폴리머 애자의 트래킹 성능 평가)

  • Cho, Han-Goo;Lee, Un-Yong;Han, Dong-Hee;Kang, Sung-Hwa;Choi, In-Hyuk;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.1
    • /
    • pp.62-67
    • /
    • 2005
  • Recently, polymer insulators that are used for high voltage applications have some advantages such as light weight, small size, vandalism resistance, hydrophobicity and easy making process. During outdoor service of polymer insulators, the surface of the insulating material is frequently subjected to moisture and contamination that lead to dry band arcing. Their tracking resistance, erosion resistance, end sealing and shed design are very important because dry band arcing causes degradation of polymer surface. Aging test to estimate life property of polymer insulator is executed through several international standard such as IEC 61109 and CEA tracking wheel test, but is not getting clear conclusion yet. There are two methods in the diagnosis method of polymer insulator such as off-line and on-line. The diagnosis methods in off-line are external condition analysis by the eye, contaminant analysis on surface, surface analysis, pollution withstand voltage test, power frequency flashover voltage test, lightning impulse flashover test, tensile fracture load test and flexural load test. Polymer material is also investigated it's tracking resistance by adding surface active agent in IEC 587. In this paper, the tracking performance of polymer insulator with salt solution which is added surface active agent. The diagnosis of insulator sample has been analyzed by leakage current and visual examination, STRI guide and thermal image camera.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극 (1.0mm 및 1.6mm)차이에 따른 동작출력 파형변화에 관한 특성연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04c
    • /
    • pp.156-158
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is avaliable to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is avaliable Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Growth Promoters and Their Effects on Beef Production - Review -

  • Song, M.K.;Choi, S.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.1
    • /
    • pp.123-135
    • /
    • 2001
  • Application of growth promoters by means of implantation or supplementation to the diets has been routine in the beef cattle industry of many countries for the better performance in growth and improvement of feed efficiency. Anabolic implants (zeranol, trenbolone acetate, and estradiol with testosterone or progesterone) have generated various positive effects. Zeranol implantation, in general, improved average daily gain (ADG), feed conversion (FC), dressing percentage (DP) and yield grade (YG) of cattle, and increased dry matter intake (DMI). Trenbolone acetate with or without estradiol also increased mean values of ADG and loin eye area (LEA) but reduced DMI and improved FC of cattle. Estradiol with testosterone or progesterone increased ADG and DMI. Anabolic implants, however, had minimal or negative effects on marbling or quality grade. The magnitude of the response to these anabolic implants in performance of beef cattle has varied depending on the type of implants, amount and duration of exposure, age of animals and combination of implants. Administration of bovine somatotropin improved ADG and FC, and decreased fat deposition. Ionophores improved FC in cattle from reduced DMI without great response to ADG. Supplementation of monensin and lasalocid reduced molar proportion of propionate. Monensin and lysocellin increased apparent absorption and retention of some minerals in cattle. Despite the improved cattle performance in growth and FC, results in beef quality from the application of the growth promoters appeared to vary or in conflict under a variety of environmental conditions.

A subjective symptom on indoor air quality in dental hygienist (치과위생사의 실내공기질에 의한 자각증상 특성)

  • Choi, Mi-Suk;Son, Bu-Soon
    • Journal of environmental and Sanitary engineering
    • /
    • v.21 no.4 s.62
    • /
    • pp.1-10
    • /
    • 2006
  • This research is based on self-filling survey which 220 dental hygienists who work in seoul participated on July 2006 through August 2006. This survey was analyzed the experience item and occurred time of the symptoms and the time of acute and vanish of the symptoms that dental office's working environment effects on physical subjective symptom. We suggest a plan to minimizing physical subjective symptom for health manage of dental hygienist. We found out the fact that dental hygienists were unsatisfied with hospital air condition and this polluted air condition cause them physical subjective symptom in work place. As follows analyzed results ventilation time is below the 3-times a day, this may be have some trouble in indoor air quality. The experience the symptoms level is higher then non-experience level in "Fatigue and sleepiness", "Dorsalgia, omarthralgia, cervicodynia", "Hypersensitivity", "Dry eye, itch, smarting", "Headaches" and a subjective symptom is occurred at after 11:00(am) more then 60%, 50% of the dental hygienist. This experience the symptom' pain is vanished after the work and reduced when go out the office and building, respectively. The ratio of the experience the symptoms and starting time the symptoms is anywhere from 12 noon to 4 pm (73.2%) in a day. The time of acute pain the symptoms is anywhere from 12 noon to 4 pm (78.7%) refer to the individual characteristics and work environment.

Special quality research about action output waveform change by gap (1.0mm and 1.6mm) difference of $CO_2$ laser for skin disease (피부질환을 위한 $CO_2$ 레이저의 공극차이에 따른 동작출력 변화에 관한 연구)

  • Kim, Whi-Young
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.52-54
    • /
    • 2007
  • Laser wave length can have evaporation effect by absorption because outer skin or tissue of focus is consisted of water almost though absorption of water occurs more than 90% almost in formation thickness of very thin floor. Can operate outer skin, steam by floor and correct incision of formation is available. Suture surgical operation is available to vein or lymph system and surgical operation region can dry and see as eye and radish bleeding surgical operation is available. Specially, stability of tube both end output about pulse by weight very, this research can cause various curative effect because can reduce bulk and control easily current wave style of medical laser using electric power conversion device of high frequency way. If introduce ZVS (Zero Voltage Switching) or ZVZCS (Zero Voltage and Zero Current Switching), is more profitable because can reduce switching damage. Because electric power department of proposed medical laser can do stable soft-switching in wide subordinate extent introducing ZVZCS technique by the first help and control department composes microcontroller, output current waveform user have free form make. Result that experiment because design and manufacture, brought result that improve of 20% than existing equipment, and will be bought to get into superior result if supplement as systematic late.

  • PDF

Strategies of upper blepharoplasty in aging patients with involutional ptosis

  • Lee, Tae-Yul;Shin, Yong Ho;Lee, Jin Gyu
    • Archives of Plastic Surgery
    • /
    • v.47 no.4
    • /
    • pp.290-296
    • /
    • 2020
  • In many aging individuals, dermatochalasis and involutional ptosis appear together. Therefore, for functional and aesthetic purposes, ptosis correction and upper blepharoplasty are performed together. The aim of this article is to investigate factors that should be considered in order to achieve good results when simultaneously performing involutional ptosis correction and upper blepharoplasty in aging patients. Involutional ptosis is usually corrected through aponeurosis advancement in mild cases. In moderate or severe ptosis, the Muller muscle and aponeurosis are used together to correct ptosis. Using the two muscles together has the advantages of reducing lagophthalmos and increasing the predictability of outcomes after surgery. Broadly speaking, the surgical method used for involutional ptosis varies depending on the specific case, but unlike congenital ptosis, it is often not necessary to perform overcorrection. In particular, if there are problems such as severe dry-eye symptoms or risk of lagophthalmos, undercorrection should be considered. When performing ptosis correction, the surgeon should be careful not to overdo skin excision; instead, limited excision should be performed. After ptosis surgery, the brow may descend and the double fold may look too small. However, in order to make the double eyelids look larger, the surgeon should consider making the double eyelid design high rather than excising an excessive amount of skin. In some cases, to obtain more natural double eyelids and favorable results, it may be necessary to perform a sub-brow lift or forehead lift before or after involutional ptosis surgery.