• Title/Summary/Keyword: dropping-preventive net

Search Result 1, Processing Time 0.015 seconds

An Experimental Study on Penetration Resistance of Styrofoams Mounted on Falling Prevention Net for Re-bar (스티로폼이 거치된 낙하물방지망의 철근 낙하에 대한 관통 저항성 실험)

  • Son, Ki-Sang;Jeon, Soo-Nam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.5
    • /
    • pp.95-98
    • /
    • 2012
  • There are many high-rise apartment building construction in Korea. There was an accident to pass through worker head by rebar dropped from height place. Therefore, low cost-high effectiveness method to prevent this type of accident should be revised and applied into the construction site. This study is to find out which method could be effectively applied to a site with low cost. Practical field test at 4th floor, 10th floor of apartment building site using re-bar diameter D10, D13, D16, D19, D22 with a length of 1 m, 1.5 m, 2 m, 2.5 m, 3 m which are common by used in a site. The test has also been done with a cover of styrofoam thickness 4.5 cm and thickness 9cm on field drop preventing net. One sheet of styrofoam thickness 45 mm has approximately two times stronger than only prevention net, It is found. Also, Two sheets have approximately two times stronger than one sheet of it.