Browse > Article
http://dx.doi.org/10.14346/JKOSOS.2012.27.5.095

An Experimental Study on Penetration Resistance of Styrofoams Mounted on Falling Prevention Net for Re-bar  

Son, Ki-Sang (Department of Safety Engineering, Seoul National University of Science and Technology)
Jeon, Soo-Nam (Department of Safety Engineering, Seoul National University of Science and Technology)
Publication Information
Journal of the Korean Society of Safety / v.27, no.5, 2012 , pp. 95-98 More about this Journal
Abstract
There are many high-rise apartment building construction in Korea. There was an accident to pass through worker head by rebar dropped from height place. Therefore, low cost-high effectiveness method to prevent this type of accident should be revised and applied into the construction site. This study is to find out which method could be effectively applied to a site with low cost. Practical field test at 4th floor, 10th floor of apartment building site using re-bar diameter D10, D13, D16, D19, D22 with a length of 1 m, 1.5 m, 2 m, 2.5 m, 3 m which are common by used in a site. The test has also been done with a cover of styrofoam thickness 4.5 cm and thickness 9cm on field drop preventing net. One sheet of styrofoam thickness 45 mm has approximately two times stronger than only prevention net, It is found. Also, Two sheets have approximately two times stronger than one sheet of it.
Keywords
low cost-high effectiveness; height place; rebar length and diameter; dropping-preventive net; styrofoam;
Citations & Related Records
연도 인용수 순위
  • Reference
1 손기상 외 2명, "건설안전공학", 기문당, pp. 185, 2012.
2 KOSHA CODE, "낙하물방지망 설치에 관한 기술지침",한국산업안전보건공단, pp. 3, 2007.