• 제목/요약/키워드: droplet charging

검색결과 14건 처리시간 0.023초

전극표면에서 액적의 충전현상과 이를 이용한 액적의 이동 방법에 관한 연구 (Research on the Electrical Charging of a Water Droplet on the Electrode and Droplet Actuation Method using Electrical Charge)

  • 정용미;오현창;강인석
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.666-669
    • /
    • 2008
  • Droplet in miniaturized microfluidic systems have received much focused attention recently. In this work, electrical charging phenomenon of a conducting water droplet on the electrode under the dc electric field is studied and using this phenomenon droplet actuation method for microreactor applications is experimentally demonstrated. To find effects of key factors, the effects of electric field, medium viscosity, and droplet size are investigated. A scaling law of charging for the conducting droplet is derived from the experimental results. Unlike the case of a perfect conductor, the estimated amount of electrical charge ($Q_{est}$) of a water droplet is proportional to the 1.59 power of the droplet radius (R) and the 1.33 power of the electric field strength (E). (For a spherical perfect conductor, Q is proportional to R2 and E.) It is thought that the differences are mainly due to incomplete charging of a water droplet resulted from the combined effect of electrochemical reaction at electrode and the relatively low conductivity of water. Using this phenomenon, we demonstrate the transport of the charged droplet and fusion of two oppositely-charged droplets. When electric field is subjected sequentially on the electrode, the charged droplet is transported on the electrode. For the visualization of fusion of charged droplets, the precipitation reaction is used. When subjected to a DC voltage, two droplets charged are moving and merging toward each other due to the Coulombic force and chemical reaction is simultaneously occurred by coalescence of droplets. It may be due to the interchange effect of charge. It is shown that the droplet can be used for microreactor where transporting, merging etc. of reagents constitute unit operation.

  • PDF

고전압 분사시스템의 액적 하전 특성연구 (A Study on Droplet Charging of an High Voltage Spraying System)

  • 손승우;유경훈;김윤신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.893-898
    • /
    • 2003
  • An experiment was conducted to characterize water droplet charging performance of an electrostatic spraying nozzle for an electrostatic wet scrubber. Charge-to-mass ratios, the nozzle currents divided by the mass flow rate of water were obtained with respect to the applied voltage to the ring-electrode for 2 different flow conditions. It was shown that the charge-to-mass ratio increased in proportion to the applied voltage and tended to saturate at a certain higher voltage.

  • PDF

비전도성 매질 내 이온성 액체 액적의 충전 현상 (Charging of an Ionic Liquid Droplet in a Dielectric Medium)

  • 임도진
    • 청정기술
    • /
    • 제20권4호
    • /
    • pp.354-358
    • /
    • 2014
  • 이온성 액체는 상온에서 액체로 존재하는 이온성염으로 최근 청정 공정에 사용될 수 있는 용매, 전해질, 촉매로써 주목받고있다. 본 연구에서는 비전도성 매질 내 액적의 접촉 충전 현상을 이용하여 여섯 가지 서로 다른 이온성 액체에 대한 충전 거동을 고찰하였다. 이온성 액체 액적의 충전 현상은 이전 수용 액적의 충전 현상과 유사한 특징을 나타내었으며 기본적으로 완전 도체 이론으로 설명이 가능하였다. 하지만 이온 종류에 따른 상세 거동은 다소의 변화가 관찰되었다. 본 연구의 결과는 청정 용매 및 촉매로 각광 받고 있는 이온성 액체의 전기화학적 특성을 이해하고 분석하는데 유용하게 활용될 수 있을 것으로 기대된다.

펄스 코로나 농약산포장치의 분무대전 특성 (Pulsed Corona Charging Characteristics of Aqueous Pesticide Spray)

  • 문재덕;이운태;배창환;권남열
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권9호
    • /
    • pp.388-394
    • /
    • 2003
  • Many toxic pesticides as aqueous-base sprays are dispensed for protection of food crops from pests into farm fields. When dispensed with conventional nozzles, a large portion of the spray is often lost by airborne drifts of droplets away and lack of deposition onto the plants due to rapid gravitational settling of droplets to the soil beneath. And target deposition efficiencies poorer than 20% are often encountered in agricultural pesticides. An electrostatic spraying technology offers a very favorable means to increasing pesticides droplets deposition onto biological surfaces of living crops. In this paper a corona type spray nozzle, utilizing a set of corona charging devices and a pulsed droplet-charging voltage applied, has been proposed and tested its potential experimentally. As a result, it exhibits a large current deposition of aqueous pesticide sprays on the sensing target, which, however, promise to be as one of the effective electrostatic spraying nozzle.

2유체 정전분무의 액체 미립화 및 분무 특성 (Liquid Atomization and Spray Characteristics in Electrostatic Spray of Twin Fluids)

  • 김정헌;배충식
    • 대한기계학회논문집B
    • /
    • 제25권11호
    • /
    • pp.1552-1560
    • /
    • 2001
  • This paper presents the experimental results of a study undertaken to develop an electrostatic spray system for a combustion application. The characteristics of the liquid atomization and the droplet dispersion in the electrostatic spray of twin fluids were investigated by the optical measurement techniques. The processes associated with the break-up of charged jets were also observed using the laser sheet visualization. The diameter and velocity of droplets were simultaneously measured using the phase Doppler measurement technique. The electrostatic atomization of the liquid fuel depended primarily on the charging voltage and the flow rate, but the dispersion of droplets depended significantly on the aerodynamic flow. Aerodynamic influences on the liquid atomization decreased with an increase of the charging voltage. Consequently, the liquid atomization and the droplet dispersion could be independently controlled using the electrostatic and aerodynamic mechanisms.

응축 증발법을 통한 서브마이크론 입자의 단극하전 특성 (Characteristics of Unipolar Charging of the Submicron Particles by the Condensation-Evaporation Method)

  • 최영주;김상수
    • 대한기계학회논문집B
    • /
    • 제30권2호
    • /
    • pp.186-192
    • /
    • 2006
  • We applied a new charging system using the condensation and evaporation method to charge the submicron particles with a uniform charging performance. The monodispersed NaCl submicron particles were condensed by n-butanol vapor and grew up to micron droplets with a same size, regardless of their initial size. Those condensed droplets were charged in an indirect corona charger. The indirect corona charger consisted of the ion generation zone and the particle charging zone. In the ion generation zone, Ions were generated by corona discharge and some of them moved into the particle charging zone by a carrier gas and mixed with the condensed droplet. And finally, the charged and condensed droplets dried through an evaporator to shrink to their original size. The average charge and penetration rate of the particles before and after evaporation were measured by CPC and aerosol electrometer and compared with those of a conventional corona charger. The results showed that the average charge was $5\~7$ charges and the penetration rate was over $90\%$, regardless of the initial particle size.

전기수력학적 미립화에서 교류 주파수가 액적 분열에 미치는 영향 (Influence of AC Frequency on the Liquid Breakup in Electrohydrodynamic Atomization)

  • 성기안;이창식
    • 한국분무공학회지
    • /
    • 제9권2호
    • /
    • pp.41-49
    • /
    • 2004
  • Liquid breakup under the variation of AC frequency has been studied experimentally in the electrohydrodynamic atomization. The effect of parameters such as charging voltage, flow rate, nozzle tip inner diameter and power frequency have been considered. This work was performed to investigate the experimental analysis for the effect of AC frequency on breakup process, the mapping of occurrence of disintegration region, and the relationship between the applied power and the droplet radius. The experimental results show that the increase of applied voltage in a certain frequency band leads to a reduction in the droplet size within the limits from 50Hz to 400Hz. The transition phenomena from dripping mode to spindle mode were observed under the band of sudden fall of droplet radius changing ratio, and the synchronous region were produced within the range of applied voltage from 5kV to 6kV.

  • PDF

Shadowgraph 가시화 기법을 활용한 정전분무액적의 크기 측정 (Size measurement of electrosprayed droplets using shadowgraph visualization method)

  • 오민정;김성현;이명화
    • 한국입자에어로졸학회지
    • /
    • 제13권4호
    • /
    • pp.151-158
    • /
    • 2017
  • 실내 환경 및 산업체 배기가스중의 미세먼지를 제거하는 방법으로서 압력손실이 낮으면서도 집진효율이 높은 전기집진기가 널리 사용되어지고 있다. 그러나 전기집진기는 서브마이크로미터 크기의 먼지에 대한 제거효율이 낮기 때문에, 정전분무법으로 하전액적을 공급하여 먼지와의 충돌을 촉진시켜 하전효율을 높이는 방법이 대안으로 떠오르고 있다. 그러나 먼지의 하전효율은 정전분무된 액적의 크기 및 개수와 밀접한 관계가 있으나, 액적의 크기를 효과적으로 측정하는 방법이 확립되어 있지 않은 것이 현실이다. 본 연구에서는 손쉽게 이용할 수 있는 수돗물로 정전분무를 한 후, 분무된 액적을 다양한 방법으로 가시화하여 고속카메라로 촬영하였다. 그리고 Image J 프로그램으로 액적의 크기분포를 측정하여 가시화방법에 따른 액적의 크기를 상호 비교하였다. 결과적으로, 레이저로 가시화하여 고속카메라로 촬영하면 미세액적의 이미지화가 가능하기 때문에, 그 액적의 크기는 Xenon광으로 가시화하여 측정한 것보다 약 50 % 작음을 알 수 있었다. 또한 레이저로 가시화하여 측정한 액적의 크기가 $Fern{\acute{a}}ndez$ de la Mora and Loscertales (1994)의 예측치와 비교적 잘 일치함을 알 수 있었다.

정전 분무 간접 하전 방식에서 미세액적 최적 발생 조건에 관한 연구 (A Study on the Optimal Generation Conditions of Micro-Droplet in Electrostatic Spray Indirect Charging Method)

  • 이지희;김성환;정해영
    • 한국전기전자재료학회논문지
    • /
    • 제37권1호
    • /
    • pp.79-87
    • /
    • 2024
  • This paper is a study on the optimal microdroplet generation conditions in indirect charging electrostatic spraying. Unlike the direct charging method, which applies power to the nozzle, the indirect charging method applies power to the discharge electrode between the nozzle and the collection electrode. Therefore, an electrically simplified system can be obtained by minimizing the insulation part a stable spray pattern can be obtained with a wide spray angle, and a stable spray pattern can be obtained with a wide spray angle. To conduct the study, an indirect charging type electrostatic spray visualization system was constructed and the static characteristics of the microdroplets were analyzed through image processing of the spray shape of the microdroplets. The total number of microdroplets and the number of microdroplets per power consumption are confirmed according to the changes in the distance between the discharge electrode and the collection electrode, the flow rate, and the applied voltage, which affect the generation of microdroplets, and using this, the optimal generation conditions are derived and the corresponding microdroplet size distribution was analyzed. As a result of the experiment, it was confirmed that the optimal generation condition was at a flow rate of 15 to 20 mL/min and a voltage of -22.5 to -25 kV in terms of the number of microdroplets, and at a flow rate of 15 to 20 mL/min and a voltage of -20 kV in terms of energy consumption efficiency.

전기적으로 대전된 액적의 스프레드-스플래시 영역 간 천이조건에 대한 연구 (Investigation of Spread-Splash Transition Criterion of an Electrically Charged Droplet)

  • 류성욱;이상용
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2995-3000
    • /
    • 2008
  • Understanding of the impinging behavior of an electrically charged spray is essential in determining appropriate operating conditions for electro-spraying of paints, surface coating materials and insecticides. In the present work, the wall impact behavior of an electrically charged drop has been investigated and compared with that of a neutral drop experimentally. The critical Sommerfeld number representing the spread-splash boundary for the charged drop impacting on the dielectric substrate turned out to be larger compared to that for the neutral drop with the same surface condition. The change of the transition boundary is due to the increase in the surface wettability of the drop on the substrate. However, with the electrically conducting substrates, the charging effect on the transition boundary appeared negligible. This is because the electric discharging time is much shorter than the time required for the flattened drop to reach its maximum extent.

  • PDF