• Title/Summary/Keyword: drop-out

Search Result 1,049, Processing Time 0.045 seconds

Sensor Node Circuit with Solar Energy Harvesting (빛 에너지 수확을 이용한 센서 노드 회로)

  • Seo, Dong-hyeon;Jo, Yong-min;Woo, Dae-keon;Yoon, Eun-jung;Yu, Chong-gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.10a
    • /
    • pp.371-374
    • /
    • 2013
  • In this paper, a sensor node circuit using solar energy harvesting is proposed. PMU(Power Management Unit) manages the energy converted from a solar cell. In order to supply a constant voltage to the sensor node, an LDO (Low Drop Out Regulator) is used. The LDO drives a temperature sensor and a SAR ADC(Successive Approximate Register Analog-to-Digital Converter). The circuit has been designed in 0.35um CMOS process.

  • PDF

Compatibility Test of the Capsule with Cone Shape Bottom Guide Structures to the HANARO Reactor (원추형 하단부 구조를 갖는 캡슐의 하나로와의 양립성시험)

  • Choi, M.H.;Cho, M.S.;Choo, K.N.;Park, S.J.;Kim, B.G.;Kang, Y.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.444-449
    • /
    • 2004
  • The design modification of bottom guide structures of the instrumented capsule, which is used for the irradiation test in the HANARO reactor, was required because of the trouble of the bottom guide arm's pin during irradiation. The previous structure with 3-pin arms was changed into the cone shape of one body. The specimens of the bottom end cap ring with three different sizes (${\Phi}68/70/72mm$) were designed and manufactured. The out-pile tests for the capsule with previous and new three bottom guide structures were performed in the one-channel flow test facilities. In order to evaluate the compatibility with HANARO and the structural integrity of the capsule, a loading/unloading, a pressure drop, a thermal performance, a vibration, and an endurance test were conducted. From out-pile test results, the capsule with the cone shape bottom guide structures was found to be more stable than the previous structure and the optimized size of the bottom guide structure selected was 70mm in diameter. It is expected that the new bottom guide structures will be applicable to all material and special capsules which will be designed and manufactured for the irradiation tests in the future.

  • PDF

A Study on the Design of ESD Protection Circuit for Prevention of Destruction and Efficiency of LDO Regulator (LDO 레귤레이터의 파괴방지 및 효율성을 위한 ESD 보호회로 설계에 대한 연구)

  • Jeong-Min Lee;Sang-Wook Kwon;Seung-Hwan Baek;Yong-Seo Koo
    • Journal of IKEEE
    • /
    • v.27 no.3
    • /
    • pp.258-264
    • /
    • 2023
  • This paper proposes an LDO regulator with a built-in ESD (Electro Static Discharge) protection circuit to effectively operate and prevent destruction of the LDO (Low Drop Out) regulator according to the load current. The proposed LDO regulator can more effectively adjust the gate node voltage of the pass transistor according to the output voltage of the LDO regulator by using an additional feedback current circuit structure. In addition, it is expected to have high reliability for the ESD situation by embedding a new structure that increases the holding voltage by about 2V by reducing the current gain on the SCR loop by adding a P+ bridge to the existing ESD protection device.

A Study on the Optimization of Fuel Metering for the Lean Combustion System in a Gasoline Engine (I) (가솔린 자동차의 희박연소시스템 적용을 위한 연료공급 최적화에 관한 연구 (I) - 가솔린 인젝터의 연료분열특성에 관한 연구 -)

  • Yoon, S.J.;Cho, D.J.;Pang, D.Y.
    • Journal of ILASS-Korea
    • /
    • v.3 no.3
    • /
    • pp.33-41
    • /
    • 1998
  • In recently, a study on the lean combustion is investigated intensively, because it is expected that this method may decrease the harmful exhaust gas and improve fuel economy in gasoline engine. The problems of lean combustion system in gasoline engine are ignition difficulty, misfire and instability of combustion. The investigation on the optimization of fuel metering and the control of mixing gas flow may be critical to improve the performance of lean combustion. In the fuel injection gasoline engine, the formation of mixture influences strongly on the engine performance such that the importance of fuel metering system becomes apparent. First of all, a study on the fuel breakup characteristics of gasoline fuel injector was carried out in this paper. Fuel injectors are pintle and 4hole-2spray type. The purpose of this study is to clarify the atomization mechanism of spray injected into atomosphere field through electronic controlled-fuel injectors, and to analyze spray characteristics such as drop size distribution and mean drop diameter produced at fuel injector. In this paper, the spray development is observed by taking photograps using 80mm still-camera system, and drop sizes are measured by PMAS. From these experiment, spray pattern injected from gasoline fuel injectors was investigated clearly. Also, it was found that SMD and drop size distribution of injected fuel spray from gasoline fuel injectors.

  • PDF

Development of a new thermal inkjet head with the virtual valve fabricated by MEMS technology (멤스기술을 이용한 가상밸브가 있는 새로운 잉크젯 헤드 개발)

  • Bae, Ki-Deok;Baek, Seog-Soon;Shin, Jong-Woo;Lim, Hyung-Taek;Shin, SuHo;Oh, Yong-Soo
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1892-1897
    • /
    • 2003
  • A new thermal inkjet printer head on SOI wafer with virtual valve was proposed. It was composed of two rectangular heaters with same size. So we could call it T-jet(Twin jet). T-jet has a lot of merits. It has the advantage of being fabricated with one wafer and is easy to change the size of chamber, nozzle, restrictor and so on. However, above all, It is the best point that T-jet has a virtual valve. And it was manufactured on SOI wafer. The chamber was formed in its upper silicon whose thickness was 40um. The chamber's bottom layer was silicon dioxide of SOI wafer and two heaters were located underneath the chamber's ceiling. And the restirctor was made beside the chamber. Nozzle was molded by process of Ni plating. Ni was 30um thick. Nozzle ejection test was performed by printer head having 56 nozzles in 2 columns with 600NPI(nozzle per inch) and black ink. It measured a drop velocity of 12m/s, a drop volume of 30pl, and a maximum firing frequency of 12KHz for single nozzle ejection. Throwing out the ink drop in whole nozzles at the same time, it was observed that the uniformity of the drop velocity and volume was less than 4%.

  • PDF

Lower Body Type of Women in their Thirties after Childbirth (출산에 따른 30대 여성의 하반신 형태 연구)

  • Lee, Jeong-Ran;Hong, Eun-Suk;Paek, Kyung-Ja
    • Fashion & Textile Research Journal
    • /
    • v.10 no.6
    • /
    • pp.979-988
    • /
    • 2008
  • The purpose of this study is to analyze the lower body size and forms of married women in their thirties who have experienced pregnancy and parturition. Their measurements derived from the direct anthropometry and indirect photographic measures were compared to those of 20's. Improving consumer satisfaction for missy brand, especially in fitness of skirt and pants, some lower body classification were presented. The results were as follows : 1. The characteristics of lower body showed many differences by individuals especially in depth, girth, length and angle measures rather than height and breadth measures. Many items including index, calculations and angles revealed significant differences compared to those of 20's. Several breadth items, crotch length had distinct increase than those of women in twenties. Flattened buttocks side silhouette from waist to hip, buttocks drooping and decrease of inclination implied the influence of pregnancy, parturition and aging. 2. We hardly find out sizing system differences between missy brand and miss brand. Based on waist and hip girth measurements of subjects, sizing system of missy apparel wasn't suitable for their body size. Excessive drop(hip girth-waist girth) of missy brands, 25~30 cm, was almost the same to the drop of miss brands. 3. To improve the size satisfaction of missy women, we classified the lower body into 5 types according to drop, buttocks angle and hip length. Type 1 was small waist with large buttocks projection, and hip length was close to an average. Type 2 was small waist with medium buttocks projection, and the hip length was close to an average. Type 3 was medium waist, with average projection of the buttocks and hip length. Type 4 was large waist, projection of the buttocks and the hip length were close to an average. Type 5 was large waist, projection of the buttocks was small and the hip length was close to an average.

Pressure Drop and Vibration Characteristics of the Capsule with the Modification of Bottom Structures (캡슐 하단부 구조변경에 따른 압력강하 및 진동특성)

  • Choi, M.H.;Choo, K.N.;Cho, M.S.;Kim, B.G.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.12 s.105
    • /
    • pp.1370-1377
    • /
    • 2005
  • The bottom structure of an instrumented capsule is a part which is joined at the receptacle of the flow tube in the reactor in-core. A geometrical change of the bottom structure has an effect on the pressure drop and the vibration of the capsule. The out-pile test to evaluate the structural integrity of the material capsule called 04M-17U was performed by using a single channel and a half core test loop. From the pressure drop test, the optimized diameter of the cone shape's bottom structure which satisfies HANARO's flow requirement (19.6 kg/s) is 71 mm. The maximum displacement of the capsule measured at the half core test loop is lower than 1.0 mm. From the analysis results, it is found that the test hole will not be interfered with near the flow tubes because its displacement due to the cooling water is very small at 0.072 mm. The fundamental frequency of the capsule under water is 9.64 Hz. It is expected that the resonance between the capsule and the fluid flow due to the cooling water in HANARO's in-core will not occur. Also, the new bottom structure of a solid cone shape with 71 mm in diameter will be applicable to the material and special capsules in the future.

Study on $CO_2$ Evaporation Heat Transfer and Pressure Drop in a Horizontal Smooth Tube (수평 평활관내 $CO_2$ 증발열전달 및 압력강하에 관한 연구)

  • Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.9
    • /
    • pp.615-621
    • /
    • 2007
  • Experimental study on the heat transfer characteristics of $CO_2$ in a horizontal smooth tube was carried out to investigate the heat transfer coefficient and pressure drop during evaporation of $CO_2$. The experiment apparatus consisted of a test section, a DC power supply, a heater, a chiller, a mass flow meter, a pump and a measurement system. Experiment was conducted for various mass fluxes ($200{\sim}1200kg/m^2s$), heat flukes ($10{\sim}100kW/m^2$) and saturation temperatures (-5, 0, $5^{\circ}C$). With increasing the heat flux, the evaporation heat transfer coefficient increased. But the variation of the heat transfer coefficient on the increase of the mass flux was not large. And the significantly drops of the heat transfer coefficient was observed at any heat flux and mass flux because of the change of the flow pattern in the tube. With increasing the saturation temperature, the heat transfer coefficient increased due to the promotion of a nucleate boiling. The measured pressure drop during evaporation increased with increasing the mass flux and decreasing the saturation temperature.

Comparison of Underwater Drop Characteristics for Hazard Apparatuses on Subsea Cable Using Fluid-Structure Interaction Analysis (유체-구조 연성해석 기반 해저케이블 위해인자의 수중낙하 특성 비교)

  • Jang, Gyung-Ho;Kim, Jeong-Hun;Song, Chang Yong
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.324-332
    • /
    • 2018
  • It is known that damages to the subsea cables used for electric power transmission between islands and countries, including renewable energy from offshore wind power, current, tides, etc., cost much to restore, which causes social and economic losses. Various types of fishing rigs and anchors have been reported to be the greatest hazards to subsea cables. It is possible to design and construct a suitable protection facility for a subsea cable by precisely estimating the underwater behavior of such hazardous apparatuses. In this study, numerical simulations of the underwater behaviors of various hazardous apparatuses were carried out using fluid-structure interaction (FSI) analysis as a basic study to simulate the actual behavior phenomena of hazardous apparatuses in relation to a subsea cable. In addition, the underwater drop characteristics according to the types of hazardous apparatuses were compared. In order to verify the accuracy of the FSI analysis method used in this study, we compared the test results for underwater drops of a steel ball bearing. Stock anchors, stockless anchors, and rocket piles, which were actually reported to be the cases of damage to subsea cables along the southwest coast of Korea, were considered as the hazardous apparatuses for the numerical simulations. Each hazardous apparatus was generated by a Lagrangian model and coupled with the fluid domain idealized by the Eulerian equation to construct the three-dimensional FSI analysis model. The accuracy of the numerical simulation results was verified by comparing them with the analytical solutions, and the underwater drop characteristics according to the types of hazard apparatuses were compared.

The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger (직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성)

  • 임동렬;박상일;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.