• Title/Summary/Keyword: drop values

Search Result 388, Processing Time 0.026 seconds

Heat Transfer Characteristics of Inclined Helical Coil Type Heat Exchanger (경사진 헬리컬 코일 열교환기의 열전달 특성에 관한 연구)

  • Son, Chang-Hyo;Jeon, Min-Ju;Jang, Seong-Il;Oh, Hoo-Kyu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.31 no.6
    • /
    • pp.707-714
    • /
    • 2007
  • The heat transfer coefficient and Pressure drop during gas cooling process of $CO_2$ (R-744) in inclined helical coil copper tubes were investigated experimentally. The main components of the refrigerant loop are a receiver. a variable-speed pump. a mass flow meter, a pre-heater and a inclined helical coil type gas cooler (test section). The test section consists of a smooth copper tube of 2.45mm inner diameter. The refrigerant mass fluxes were varied from 200 to $600[kg/m^2s]$ and the inlet Pressures of gas cooler were 7.5 to 10.0 [MPa]. The heat transfer coefficients of $CO_2$ in the inclined helical coil tubes increases with the increase of mass flux and gas cooling pressure of $CO_2$. The pressure drop of $CO_2$ in the gas cooler shows a relatively good agreement with those Predicted by Ito's correlation developed for single-phase in a helical coil tube. The local heat transfer coefficient of $CO_2$ agrees well with the correlation by Pitla et al. However, at the region near pseudo-critical temperature. the experiments indicate higher values than the Pitla et al. correlation. Therefore. various experiments in the inclined helical coil tubes have to be conducted and it is necessary to develop the reliable and accurate prediction determining the heat transfer and pressure drop of $CO_2$ in the inclined helical coil tubes.

The Pressure Drop and Heat Transfer Characteristics of a Direct Contact 4-Stage Fluidized Bed Heat Exchanger (직접 접촉식 4단 유동층 열교환기의 압력손실 및 열전달 특성)

  • 임동렬;박상일;전광민
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.16 no.2
    • /
    • pp.325-335
    • /
    • 1992
  • In this work, direct contact 4-stage fluidized bed heat exchanger is experimentally studied to develop a new type of heat exchanger which recovers the energy contained in the high temperature waste gas exhausted from the industrial furnaces. A sand is used as a heat transfer medium in this experiment. To determine the optimum operating condition, 11 different perforated plates which have a different free area ratio with different hole diameter are used in the experiment. From the room temperature experiment, the pressure drop which is caused by fluidized bed formation is observed. The high temperature experiment is carried out to seek the optimum operating condition of high heat efficiency at low heat exchanger operation cost. The results of experiment are as following. The pressure drop in the high temperature condition can be predicted from the results of the room temperature experiment. And Nusselt number becomes smaller due to the increased interference between sand particles as Reynolds number increases when the dilute phase fluidized beds are formed in nigh temperature condition. But heat transfer amount through the total sand surface area become larger due to the large resident amount of sand. Considering the heat transfer amount and the heat exchanger operation cost, perforated plates which have either a 30% or 35% of free area ratio with 15mm of hole diameter are best fitted for our goal of this work. The values of .phi. which is a dimensionless number representing the absorption heat amount per unit sand rate are in the range from 0.4 to 0.5, when Reynolds number of waste gas ranges from 25-30 with these perforated plates.

The Effect Analysis of Postural Stability on the Inter-Segmental Spine Motion according to Types of Trunk Models in Drop Landing (드롭착지 동작 시 체간모델에 따른 척추분절운동이 자세안정성 해석에 미치는 영향)

  • Yoo, Kyoung-Seok
    • Korean Journal of Applied Biomechanics
    • /
    • v.24 no.4
    • /
    • pp.375-383
    • /
    • 2014
  • The purpose of this study was to assess the inter-segmental trunk motion during which multi-segmental movements of the spinal column was designed to interpret the effect of segmentation on the total measured spine motion. Also it analyzed the relative motion at three types of the spine models in drop landing. A secondary goal was to determine the intrinsic algorithmic errors of spine motion and the usefulness of such an approach as a tool to assess spinal motions. College students in the soccer team were selected the ten males with no history of spine symptoms or injuries. Each subject was given a fifteen minute adaptation period of drop landing on the 30cm height box. Inter-segmental spine motion were collected Vicon Motion Capture System (250 Hz) and synchronized with GRF data (1000 Hz). The result shows that Model III has a more increased range of motion (ROM) than Model I and Model II. And the Lagrange energy has significant difference of at E3 and E4 (p<.05). This study can be concluded that there are differences in the three models of algorithm during the phase of load absorption. Especially, Model III shows proper spine motion for the inter-segmental joint motion with the interaction effects using the seven segments. Model III shows more proper observed values about dynamic equilibrium than Model I & Model II. The findings have shown that the dynamic stability strategy of Model III toward multi-directional spinal motion supports for better function of the inter-segmental motor-control than the Model I and Model II.

Validity and Reliability of New Digital Navicular Drop Test Equipment in Young People

  • Park, Jin-Seong;Park, Du-Jin
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.279-285
    • /
    • 2021
  • Purpose: This study aimed to develop new digital navicular drop test (ND-NDT) equipment and to determine its validity and reliability. Methods: A total of 24 healthy male and female adults, who fully understood the purpose of the study and gave consent to participate in the study, were selected as participants. The NDT and ND-NDT were conducted in the dominant foot of the participants in a random order. For the NDT, the position of the navicular bone was marked with a pen first; then, the height of the navicular bone from the ground was measured in both sitting and standing positions. For the ND-NDT, after the sticker-type reflection markers were attached to the position of the navicular bone, the height of the navicular bone from the ground was measured in both sitting and standing positions. To assess the validity of the diagnostic tests, the same examiner measured the height of the medial longitudinal arch (MLA) three times in both the sitting and standing positions. To assess the inter-rater reliability of the ND-NDT, three examiners, in a random order, attached the sticker-type reflection markers to the position of the navicular bone and then measured the height of the MLA in both positions. Results: In the sitting position, the Pearson correlation coefficient (r) between the two diagnostic tests was very high (r = 0.97) and statistically significant. In the standing position, the Pearson correlation coefficient (r) between the two tests was 0.95, which was also statistically significant. The ICC2,1 values in the sitting and standing positions were 0.93 and 0.95, respectively, indicating significantly high inter-rater reliability. Conclusion: The ND-NDT equipment showed very high diagnostic validity, as well as excellent inter-rater reliability, indicating the clinical usefulness of the equipment as a diagnostic system for confirming pes planus.

A Korean-American Comparative Study of 3D Scanned Female Anthropometric Data

  • Yi, Kyonghwa;Cynthia, L. Istook
    • Journal of Fashion Business
    • /
    • v.17 no.3
    • /
    • pp.74-84
    • /
    • 2013
  • The purpose of this research is to provide useable data for application in American and Korean apparel company. This data was developed by analyzing information of Korean and American body sizes obtained from "Size USA Project" and "Size Korea Project". The Subjects were 6,306 American females and 1,988 Korean females over 18 years old. 30 measurements and 14 computed values were chosen that were considered critical in making garments. And descriptive analysis, percentile analysis and t-test were used as statistical methods for analyzing measurements and computed value between the two countries. The results were as follows. It was determined that American women were larger and bigger than Korean women in all measurements and computed values, except for Shoulder Slope. Based on BMI values, we determined that American women had a distinct tendency towards being overweight. Through the comparison of drop values (i.e. the difference between Hip and Bust Girths or Hip and Waist Girths), ratio values (i.e. waist height divided by height) and Body Mass Index (BMI) between the two countries, we determined that American women's figures were shapelier than Korean women's. American women had higher hip heights and longer leg lengths for their height compared to Korean woman. Furthermore, the back shapes of Korean women were flatter than American women and BMI values indicated American women were relatively more overweight than Korean women.

A Study of Rewetting Temperature in Cooling of Hot Surfaces (高溫表面의 冷却時 再水着 溫度 에 관한 硏究)

  • 정문기;이영환;박종석
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.9 no.4
    • /
    • pp.463-470
    • /
    • 1985
  • In this study a parametric analysis for the rewetting temperature was made with 572 data obtained from the single tube experiment. The rewetting temperature was also evaluated by measuring the vaporization time of a liquid drop on a hot surface at the elevated pressures. The results showed that the rewetting temperature increased with flooding rate, inlet subcooling pressure and initial wall temperature, and decreased with increasing axial elevation. Based on the results obtained, the rewetting temperature correlation was suggested. From the comparison of correlated rewetting temperatures with measured values, it showed that the correlated values fell within .+-.5% error from the measured values.

Wetting Behavior of Low Temperature Molten Frits on Various Ceramic Substrates (세라믹 기판에 대한 저온 용융프릿트의 침윤 거동)

  • 노태준;오근호;이종근;김대웅
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.3
    • /
    • pp.199-204
    • /
    • 1983
  • An attempt was made to study wetting behavior of various low temperature molten frist on ceramic substrates including high alumina silicon carbide and porous fired clay plates by Sessile-drop method. The cosine values of contact angles between substrates and molten frist were linear as a function of temperature unless chemical reactions between substrate and molten frit occured. Addition of BaO to frit composition indicated that cosine of values of contact angles were gradually increased with increasing temperature but in the frist contained $Li_2O$ consine values were abruptly increased with increasing temperature after reached a certain temperature. The contact angle increased with increasing roughness of the substrate surface in case of alumina substrate plate.

  • PDF

Investigation of Minimum Number of Drop Levels and Test Points for FWD Network-Level Testing Protocol in Iowa Department of Transportation (아이오와 주 교통국의 FWD 네트워크 레벨 조사 프로토콜을 위한 최소 하중 재하 수와 조사지점 수의 결정)

  • Kim, Yong-Joo;Lee, Ho-Sin(David);Omundson, Jason S.
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.39-46
    • /
    • 2010
  • In 2007, Iowa department of transportation (DOT) initiated to run the falling weight deflectometer (FWD) network-level testing along Iowa highway and road systems and to build a comprehensive database of deflection data and subsequent structural analysis, which are used for detecting pavement structure failure, estimating expected life, and calculating overlay requirements over a desired design life. Iowa's current FWD networklevel testing protocol requires that pavements are tested at three-drop level with 8-deflection basin collected at each drop level. The test point is determined by the length of the tested pavement section. However, the current FWD network-level program could cover about 20% of Iowa's highway and road systems annually. Therefore, the current FWD network-level test protocol should be simplified to test more than 20% of Iowa's highway and road systems for the network-level test annually. The main objective of this research is to investigate if the minimum number of drop levels and test points could be reduced to increase the testing production rate and reduce the cost of testing and traffic control without sacrificing the quality of the FWD data. Based upon the limited FWD network-level test data of eighty-three composite pavement sections, there was no significant difference between the mean values of three different response parameters when the number of drop levels and test points were reduced from the current FWD network-level testing protocol. As a result, the production rate of FWD tests would increase and the cost of testing and traffic control would be decreased without sacrificing the quality of the FWD data.

Prediction and Experiment of Pressure Drop of R22 and R134a on Design Conditions of Condenser (응축기의 설계조건에서 R22와 R134a의 압력강하 예측 및 실험)

  • Kang, Shin-Hyung;Byun, Ju-Suk;Kim, Chang-Duk
    • Journal of Energy Engineering
    • /
    • v.15 no.4 s.48
    • /
    • pp.243-249
    • /
    • 2006
  • An experimental study on the refrigerant-side pressure drop of slit fin an tube heat exchanger has been carried out. A comparison was made between the predictions of previously proposed empirical correlations and experimental data for the pressure drop on design conditions of condenser in micro-fin tube for R22 and Rl34a. Experiments were carried out under the conditions of inlet refrigerant temperature of $60^{\circ}C$ and mass fluxes varying from $150\;to\;250\;kg/m^{2}s$ for R22 and Rl34a. The inlet air conditions are dry bulb temperature of $35^{\circ}C$, relative humidity of 40% and air velocity varying from 0.68 to 1.43 m/s. Experiments show that pressure drop for R134a was $22{\sim}22.6%$ higher than R22 for the degree of subcooling $5^{\circ}C$ For the mass fluxes of $200{\sim}250\;kg/m^{2}s$, the deviation between the experimental and predicted values for the pressure drop was less than ${\pm}20%$ for R22 and Rl34a.

Experimental Study for Prediction of Ground Vibration Responses by the Low-vibration Pile Driving Methods (저진동 파일시공법에 따른 지반진동 응답 예측을 위한 실험적 연구)

  • Kang, Sung-Hoo;Jeoung, Sug-Kyu;Park, Sun-Joon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.4
    • /
    • pp.299-306
    • /
    • 2011
  • This study investigated the SIP-method as a low-vibration, low-noise engineering method. The ground vibrations caused by the SIP-method were measured and analyzed in each step. From the analysis results, quantitative ground vibration values and reliable vibration estimation equations were proposed. Furthermore, the ground vibrations caused by the SIP-method were compared with the ground vibrations caused by other methods presented by existing studies. Based on the vibration estimation equation with 50 % reliability, the ground vibration values by the SIP-method at the distance of 10~150 m corresponded to 17~57 % of the ground vibration values by the equation proposed by Attewell & Famer, and 14~96 % of the ground vibration values by the equation proposed by Prof. Park in his study using a diesel drop hammer. These results showed that the ground vibration reduction effect of the SIP-method was higher those of other general engineering methods. Finally, the permissible scope of work using the SIP-method which meets the domestic vibration standards was presented.